| 1 | Supplying, erection,testing and commissioning of HOT Dip galvanized octagonal steel pole of8 mtr height and made out of 3 mm thick sheet PCD 270 mmhaving bottom 130 mm A/F & top 70 mm A/Fwith built in connector control box of length 500 mm at 1000 mm height from base plate, M.S base plate of size 270 mm x 270mm x 20 mm thick, single overhang bracket made of 1500 mm madeout 48 mm dia pipe ,Class\"B\" Thickness 400 mm long top galvanized tube of suitable dia to fittings, complete with 250 mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook just below the strip provided & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box.(a). 6 mm thick phenolic laminated sheet/ bakelite sheet inside the window mounted on the existing mounting strips inside the flush door. (b).Supply & fixing 40 amp terminal block suitable for 16 sq. mm conductor- 4 nos. & shorting links-5 nos. on DIN Channel i/c pdg and fixing DIN channel of suitable length- 2 nos. on existing laminated sheet (c)terminal suitable for 6 SWG G.I Wire/1.5 sq. mm wire(d) 6 Amp,SP MCB,10 KA, ‘C’ Series – 1 nos. including mounting on din channel, earth stud 2 nos. welded at suitable height i/c washers & nuts etc. (e).Suitable arrangement for saddling of incoming / outgoing cables i/c lugs/thimbles etc as required. |
| 2 | Providing and laying in position, M25 reinforced cement concrete foundation of size 500mm long x 500mm wide and 1400 mm deep i/c excavation of earth, refilling, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1500 mm long (approx.)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2000 mm long (approx.)-8 Nos. (With approx. 150 mm spacing) i/c centering& shuttering as required, positioning of foundation bolts 4 nos. M-24x750mm long foundation bolt of L Type (100 mm bend & 750 mm straight), 150 mm top threaded portion of bolt shall be galvanized and rest portion shall be coated with Red oxide to avoid corrosion & G.I nuts (EN 8-grade) with 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 270 mm x 270 mm x 4 mm thick shall be supplied manufactured from the original pole manufacturing company only for casting of foundations and providing 63 mm (OD) 2 Nos. DWC pipe 1 mtr long approx. each for cable entry and exit etc complete as required. |
| 3 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 <120 lm/Watt) Supplying, installation, Testing &Commissioningof Street light LED fixture powder coated pressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)a) 72 Watt |
| 4 | Supplying, installation, testing & commissioning of floor mounted free standing type L.T. cubical main feeder pillar (outdoor type) with 200 Amps4 strips Al. bas bars, cable alleys , IP:54 rating dust and varmin proofduly compartmentalizedsuitable to accommodate the incoming and outgoing switch gears, made out of 2mm thick MS CRCA sheeti/c providing 40 mm x 40 mm x 5 mm thick MS angle iron frame work all around for mounting 4 nos. x 750 mm long 40 mm x 40 mm x 5 mm thick angle iron legssuitably grouting inCC foundation of 1:2:4 ( 1 Cement : 2 Coarse sand: 4 graded stone aggregate20 mm nominal size with 750 mm deep ( 450 mmin ground and 300 mm above ground level and foundation size exceeding 150 mm on all sides of feeder pillar baseand connections, inter connectionswith suitablerating copper wires/strips, thimbles/lugs, earthing the body, painting etc complete with followingswitchgears and accessories as requireda) 100 A,30KA,FPMCCB- 1 No (in comer) & 63 amp , 30KA ,FPMCCB - 2 No (out comer)b) Compartment having space for DISCOM energy meter with 6mm thick Bakelite sheet for mounting energy meter.c) Volt meter (0-500V) 96 Sq.mm with selector switch – 1 Setd) Amp-meter (0-100A) 96Sq.mm with selector switch & 100/5 Amp ratio CT\"s – 1 Sete) Indication Lamp (RYB) with control MCB fitting- 1 set.f) 20/32 amp DP MCB,’C’ Series 10 KA, (out going circuit)- 9 Nos.g) 6 amp SP MCB – 1 No.h) Power contactor, 3 pole, 110 Amp. -1 No. i) Astronomical Timer switch – 1 No.j) Auto/Manual toggle switch – 1 No.k) 200 amp, 4 strip aluminium busbar – 1 Setl) Danger Notice plate – 1 No.m) 6 Pin 15 A Switch / Socket outlet - 1 Set. n) Lighting inside the feeder pillar. Note: Foundation shall be made as per site requirement for which nothing extra shall be paid. |
| 5 | Supplying, and Installation, testing and commissioning ofFloor mounted feeder pillar double door cubicalpanel board of size 1000mm x 900mm x 300mm deep with general arrangemnent made out of 2 mm thick CRCA MS sheet having hinged gasketed cover and screw type knob with double locking arrangment and rain protection cover mounted on MS angle iron base frame made out of 35mm x 35mm 5mm angle iron with 1 mtr. long legs grouted with 1:3:6 foundation and should be 0.6 mtr. above ground level as per drawing approved by Enginer-in-charge. Legs should be covered with brick wall, connection, inter-connection with suitable size PVC insulated copper conductor wire using thimbles wherever required, painting after applying a coat of primer numbering i/c supplying and fixing of following accessories etc. as reqd.(a) 63 Amps. 36KA, 4 pole MCCB----- 1 No.(b) 6/32 Amps. SP MCB (‘C’-Series)----- 6 Nos.(c) Timer switch suitable for 240 voltsAC Supply for daily operation. ----- 1 No.(d) 40 Amps. 240/415 volt 3 polepower contactor.----- 1 No.(e) 4 way neutral link/connector--- 2Nos.(f) volt meter with selector switch(0-500V) ---- 1No.(g)indicating Lamp Set------ 1Set.(h) Al. Bus Bar100 amp. 4 strip, suitable size----- 1 Set(i)20 Amp. SP industrial socket -- 1 No.(j)Danger notice plate----- 1 No. |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (3 x 1.5 sq. mm) |
| 7 | Supplying of following size of XLPE insulatedaluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd.a) 2C x 16 sq.mm |
| 8 | b) 3.5C x 35 sq.mm |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm |
| 10 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 90 mm dia (OD- 90mm & ID-76 mm nominal) |
| 11 | Earthing with G.I earth pipe 4.5 mtr. Long,40 mm dia i/c accessories and providing masonry enclosure with cover plate, having locking arrangement and watering pipe etc. with charcoal or coke & Salt as reqd. |
| 12 | Providing & Fixing25 mm X 5 mm G.I Strip on surface or in recess for connection etc. as reqd. |
| 13 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 14 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |