| 1 | Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with GI hexagonal adopters/Nuts on the both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge. |
| 2 | Supply and installing of the electric water storage heater of ABS body type of 15 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with GI hexagonal adopters/Nuts on the both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge . |
| 3 | Material and labour in repair for sub main wiring with two run of single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 20mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface complete all as specified and as directed. |
| 4 | M & L for GI tubing (ISI Marked) for medium grade 15mm bore fixed on floor/wall complete including all the necessary fittings to hold the pipe along the wall like hook, bolts etc. incl drilling/cutting hole of suitable size on wall for passing through the GI tubing and making good the disturbed surfaces of wall complete all as specified and directed. |
| 5 | S&F stop valve/ angle valve (ISI marked),15mm dia, cast copper alloy, chromium plated fancy type screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. |
| 6 | S&F bib taps, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. |
| 7 | Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 50 Sqmm 3.5 core, complete all as specified and directed. |
| 8 | Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 Sqmm 4 core, complete all as specified and directed. |
| 9 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc. including getting out in any type of soil complete all as specified and directed. |
| 10 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 11 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. |
| 12 | M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009).Note :Sand shall be fined sand as specified and punned thickness shall be measured and paid. |
| 13 | Supply and laying sub class \"B\" bricks of old size (230x115x75 mm) or of size locally available ,laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for Earthing complete with galvanized cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level usinggalvanized iron strip 25x4mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSRcomplete all as specified and directed by Engineer-in-charge incl testing on completion. |
| 15 | Supply & installation of Galvanized steel high mast lighting system of 20 meter heightin two/three section, 3 mm section thickness, top dia not less than150 mm, bottom dianot less than 360 mm, with 2/3 wire rope system and its accessories. System is suitable for loading 08 nos 250 WattLED Flood lightslantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of not less than 6 mm dia 97/19 guage and double drum winch and motorwith luminaire mounting arm, pully assembly, aviation obstruction light as per desigh , lightning arrester spike including RCC foundation as per height and suitable for 47 m/sec wind speed as per IS: 875 part-III, with head frame, winch mounting bracket, luminaries carriage suitable to install 8 nos Flood light luminaries in symmetrical arrangement (150/360) of raising lowering system complete double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial Wiring material from JB to individual luminaire & MCB in base compartment included and complete all as directed by the Engr-in-Charge. Note: This rate including all connected accessories and Excavation & PCC work for foundation of pole and all nuts bolts and washers of foundationis alsoincluded in the quoted rates. |
| 16 | Supply, installation, testing and commissioning of LT Panel/Bus baroutdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, made out 3.15 mm thick CRCA sheet with angle iron frame of size 65 x 65 x 5 mm cubical type and frame height not less than 45 cm from ground level, complete with 4 Nos Aluminium bus bar 200 Amp, MCCB 4 Pole , 100 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) & MCCB 4 Pole , 63 Amp, 415 V, 16 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (outgoing) &RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copperconductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated paintinginner & outer side, including making all suitable necessary electrical connection completeall as directed by the Engineer -in - Charge. Note : (i) The panel shall be as per CPRI certificate.(ii) The rates deemed to be inclusive necessary PCC for grouting of panels and all around 45 cm of radius of tha panel. |
| 17 | Supply and fixing LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and suitable for mounting on high mast poles andcomplete all as directed by the Engr-in-Charge. |
| 18 | Supply and fixing of DBOXx MCB protected socket with sheet steel enclosure single pole 25 Amp with 3 Pin plug top for AC/Geyser connection from socket point to stablizer complete all as specified and as directed. |
| 19 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |