| 1 | Cleaning and clearing of blockage from any type of WCs (Indian/European), trap & Cl pipe line upto 1st manhole manually by rodding, pumping etc (including taking off manhole covers and re-fixing the same after cleaning) of any description, underground and at any depth by removing any type of blockage including de-silting and de-chocking (Sludge/sludge water shall be disposed off at authorized dumping site declared by local administration outside MD land complete all as specified and as diretted by the Engineer-in-charge. |
| 2 | Excavation in any type of soil (hard/dense or mud) for getting out puncturing or existing damaged/broken or otherwise nonfunctional salt glazed stone ware pipeupto 150 mm dia bore (length of pipe 60 cm) , and supply and fixing salt glazed stone ware pipe of dia upto 150 mm bore , ISI Marked including PCC 1:3:6, type C-2 in bed and haunching as required,jointing with existing line, returning, filling in and well ramming the soil and removal of surplus soil to a distance n.exc 50 mtrs and deposited where directed , complete all as specified and directed. |
| 3 | All as per serial item No 2 herein before but for 200mmbore of pipe, complete all as specified and directed |
| 4 | All as per serial item No 2 herein before but for 300mmbore of pipe, complete all as specified and directed |
| 5 | Plain cement mortar 1:3:6 (type C-1 using 20mm graded stone aggregate), 50mm thick as in Plinth protection/hardstanding , finishing cement concrete even and smooth without using extra cement,all as specified. |
| 6 | Plain cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in copings, surface channel and the like complete all as specified and directed. |
| 7 | Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. |
| 8 | All as per srl item No 7 here in before but depth exc 1.50 m but n exc 3.0 m , complete all as specified and directed. |
| 9 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 10 | Removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 11 | Demolition and breaking up drain pipes of any type and description internal dia of pipe 150mm, set in cement mortar, PCC packing in bed and haunching etc complete,all as specified and directed. Note:Excavation and earth work shall be measured and paid separately. |
| 12 | All as per serial item No 11 here-in-before but internal dia of pipe 200mm, complete all as specified and directed. |
| 13 | All as per serial item No 11 here-in-before but internal dia of pipe 300mm, complete all as specified and directed. |
| 14 | Plain cement concrete type D-2, 1:4:8 using 40mm graded crushed stone aggregate as in bed to drain pipes including packing in bed and haunching cradle of 150mm bore pipe after the pipes are laid and tested , complete all as specified and directed. |
| 15 | All as per serial item No 14 herein before but for 200mm bore pipe, complete all as specified and directed. |
| 16 | All as per serial item No 14 herein before but for 200mm bore pipe, complete all as specified and directed. |
| 17 | Salt-glazed stoneware drain pipes, 150 mm bore, laid in trench and jointed as specified,complete with collars,complete all as specified and directed. |
| 18 | All as per serial item No 17 here-in-before but internal dia of pipe 200mm, complete all as specified and directed. |
| 19 | Reinforced concrete pipes, 150 mm boreclass NP2, laid in trench and jointed completewith collars , jointed with cement mortarinculding fitting of same grade complete all as specified and directed. |
| 20 | All as per serial item No 19 here-in-before but internal dia of pipe 200mm, complete all as specified and directed. |
| 21 | All as per serial item No 19 here-in-before but internal dia of pipe 300mm , complete all as specified and directed. |
| 22 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required,for internal dia of pipe 150mm all as specified and directed. |
| 23 | All as per serial item No. 22 herein before but internal dia of pipe 200mm complete all as specified and directed. |
| 24 | 100mm bore cast iron soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors, fixed as in repair complete all as specified and directed. (Excavation and earth work shall be measured and paid for separately) |
| 25 | All as per serial item No 24 herein before but 75mm bore of pipes complete all as specified and directed. |
| 26 | 100mm bore cast iron soil waste and vent pipes in any length with or without ears with cement joints fixed to walls, fixed as in repair complete all as specified and directed. (Excavation and earth work shall be measured and paid for separately) |
| 27 | All as per serial item No 26 herein before but 75mm bore of pipescomplete all as specified and directed. |
| 28 | CI inspection lid of size 75mm dia for soil and waste pipe including nuts, bolts etc, fixed as in repair complete all as specified and directed. |
| 29 | CI 75mm bore branch pieces equal or unequal or inverted (spigot socketed type or with parallel branches fitted with oval acccess door), fixed as in repair complete all as specified & directed. |
| 30 | All as per item No. 29 herein before but for 100mm bore pipe complete all as specified and directed. |
| 31 | Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), suitable for 75 mm bore spun pipes, fixed as in repair ISI marked, complete all as specified. |
| 32 | All as per serial item No 31 herein before but 100mm bore of pipes complete all as specified and directed. |
| 33 | Stack clamps for 75mm bore pipe, made out of 30mm x 5mm size, flat ironround stays, including screws/ Nails and securing ends of stays to wall or roof, fixed as in repair complete all as specified and directed. |
| 34 | All as per serial item No 33 herein before but 100mm bore of pipes complete all as specified and directed. |
| 35 | Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed |
| 36 | Brick work, with sub class\"B\" brickstraight or curved on plan exc 6m means radius, built in cement mortor (1: 4) as in manholes, septic tanks, soakage well etc , complete all as specified and as directed . |
| 37 | All as per serial item No. 36 herein before but except bricks, complete all as specified and directed. |
| 38 | Rendering15mm thick on brick masonary in cement mortar (1:4), finishing surfaces even and smooth without using extra cement,complete all as specified and as directed. |
| 39 | Rendering15mm thick on brick masonary in cement mortar (1:4), finishing surfaces even and smooth without using extra cement,including taking down cement plaster complete all as specified and as directed. |
| 40 | Precast factory made RCC manhole covers of size 450 mm x 450 mm x 75mm, as in cover slab of gully trap includingMS ring, MS frame, set in position in cement mortar 1: 4 fixed as in repair complete all as specified. |
| 41 | Factory made RCC M-35 pre cast man hole covers(Medium duty), of size 600mm x 600mm x 75mm with plain faces, includingMS ring, MS frame, set in position in cement mortar 1:4, fixed as in repair complete all as specified. |
| 42 | All as per serial itemNo 41 hereinbefore but size 750mm x 750mm x 75mm thick complete all as specified and directed. |
| 43 | All as per serial itemNo 41 hereinbefore but size 600mm x 900mm x 100mm thick, complete all as specified and directed. |
| 44 | All as per serial itemNo 41 hereinbefore but size 600mm x 1200mm x 100mm thick, complete all as specified and directed. |
| 45 | All as per serial itemNo 41 hereinbefore but size 600mm x 1500mm x 100mm thick, complete all as specified and directed. |
| 46 | PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors, fixed as in repairs, complete all as specified and directed. |
| 47 | All as per serial item No 46 herein before but 110mm bore of pipe, complete all as specified and directed. |
| 48 | PVC (SWR)pipe, 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,fixed in repairs, complete all as specified and directed. |
| 49 | All as per serial item No 48 herein before but 110mm bore of pipe, complete all as specified and directed. |
| 50 | PVC (SWR) bend any radius for 75mm bore pipe, fixed as in repairs, complete all as specified and directed. |
| 51 | All as per serial item No 50 herein before but 110mm bore of pipe, complete all as specified and directed. |
| 52 | PVC (SWR) floor trap 75mm bore, plain with grating incl jointing with solvent cement, fixed as in repairs, complete all as specified and directed. |
| 53 | PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed as in repair complet all as specified and dircted. |
| 54 | Demolition of cement concrete (reinforced) of any description andin any position complete all as specified and directed. |
| 55 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 56 | Removing /cleaning away all grass vegetation,saplings,hrubs, undergrowth and trees not exceeding 30cms girth, applying two coat antivegitation chemical, making good with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate and removing rubbish upto a distance not exc. 50m, complete all as specified and directed. |
| 57 | 75mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floors & pavings etc, finished even and smooth complete all as specified and directed. |
| 58 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 59 | Concrete interlocking paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, and laid over and including 25mm thick sand cushioning,including dismantling of old paver block complete all as specified and directed |
| 60 | Factory made machine pressed chequered cement concrete tiles 250mm x 250mm x 20-25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over & including 20mm thick screed bed in cement mortar 1:6, including dismantling of old tile complete all as specified and directed. |
| 61 | Clearing and desilting of manholes of size n.exc 1.20m x 1.20m and depth n.exc 1.5m and removing the sludge to a distance exc 250m and n.exc 500m and depostied where directed in and including borrow pits and covering the borrow pits with 10 cms thick layer of soil,including pumping out liquid and liquid sludge if required , complete all as specified and directed. |
| 62 | Clearing and desilting of manholes of size n.exc 1.20m x 1.20m and depth exc 1.5m but n. exc 3 m and removing the sludge to a distance exc 250m and n.exc 500m and depostied where directed in and including borrow pits and covering the borrow pits with 10 cms thick layer of soil including pumping out liquid and liquid sludge with pumping machince,complete all as specified and directed. |
| 63 | Clearing and desilting of manholes of size n.exc 1.20m x 1.20m and depth exc 3.0m but n. exc 4.50 m and removing the sludge to a distance exc 250m and n.exc 500m and depostied where directed in and including borrow pits and covering the borrow pits with 10 cms thick layer of soil including pumping out liquid and liquid sludge with pumping machince,complete all as specified and directed. |
| 64 | Cleaning and clearing of underground sewage line upto 300 mm bore pipe of any description, underground at any depth , (including manholes by taking off manhole covers and re-fixing the same after cleaning)removing any type of blockage including de-silting and de-chocking with combined high pressure water jetting cum suction (vaccum) `type machine mounted on LCV/HCV and having facilities of high pressure shape nozzle pipe and flushing after cleaning of manholes, all as directed by Engineer-in-Charge.Note:sludge/sludge water shall be disposed off at authorized dumping site declared by local administration, duly covered in a hygienic manner while transporting outside MOD land. |
| 65 | Clearing and desilting of septic tank upto 50 users,depth exc 1.5m but n.exc 3.00m with combined high pressure water jetting cum suction (vaccum) type machine mounted on LCV/HCV and having facilities of high pressure shape nozzle pipe and flushing after cleaningof sludge/sludge water shall be disposed off at authorized dumping site declared by local administration duly covered in a hygienic manner while transporting outside MOD land)complete all as specified and directed.NOTE for serial item No 61 to 65 :- (i) Net contents of sludge shall be measured at the time of removal and paid(ii) The rate inclusive of dewatering as required and nothing extera shall be paid extra on this acccount. |