| 1 | Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with GI hexagonal adopters/Nuts on the both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge . |
| 2 | Material and labour in repair for sub main wiring with two run of single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 20mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface complete all as specified and as directed. |
| 3 | M&L for GI tubing (ISI Marked) for medium grade 15mm bore fixed on floor/wall complete including all the necessary fittings to hold the pipe along the wall like hook, bolts etc. incl drilling/cutting hole of suitable size on wall for passing through the GI tubing and making good the disturbed surfaces of wall complete all as specified and directed. |
| 4 | S&F stop valve/ angle valve (ISI marked),15mm dia, cast copper alloy, chromium plated fancy type screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. |
| 5 | Supply, installation and testing all weather (hot & cold) split AC units indoor and outdoor of 2 Ton Capacity 3 star rating with EER not less than 3.2 complete with cordless remote control unit, inbuilt anti microbial air filtration for better indoor air quality including copper piping of suitable size with insulation, PVC drain pipe, mounting plate for indoor unit and brackets of powder coated GI steel for outdoor units and mounting with suitable size of anchor bolts and nuts incl making hole of suitable size on wall for passing wire and copper pipes complete all as specified and directed. |
| 6 | Supply and fixing single phase voltage stabilizer of capacity 5KVA for automatic operation, copper wounded air cooled indoor type & designed for input variation between 170V to 270 V with output voltage stabilized at 230 with accuracy ±5% including 3 core flexible wire of suitable size drawn through and incl concealed PVC conduit medium grade from stabilizer to power point and making good the disturbed surface complete all as specified and directed. Note: Cutting chasing the wall for concealing conduit and making good the disturbed surface deemed to be included in the quoted rates. |
| 7 | Material and labour for Point wiring any length from distribution board to AC socket with FRLS PVC insulated unsheathed multi stranded copper conductor cable of size 4.0 sqmm including 4.0 Sqmm FRLS PVC insulated unsheathed copper conductor as earth wire drawn through and including concealed PVC conduit (ISI Marked) medium grade of size not less than 20 mm outer dia and 1.5 mm thick including all fittings viz tees, bends, junctions boxfor one AC point including cutting chases in wall for concealing of conduit andmaking good to disturbed surface of wall with cement mortar and finishes to match with existing specification(conduitshall be fixed on surface of ceiling/wall with necessary saddles where concealing of conduit is not feasible) complete all as specified. |
| 8 | Supply and Fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 32Amps with breaking cap 10kA complete all as specified and directed. |
| 9 | M&L for cutting including screwing existing steel tubing for alternation or addition incl Tee/Nipple upto 25-32mm dia pipe complete all as specified and directed. |
| 10 | Supply, fixing, stringing and drawing submain wiring with 2 run of single core, 6 sqmm PVC insulated and unsheathed, multi strandedcopper conductor cable FRLS usingcolour code forphase red and neutral black with and including6 sqmmPVC insulated and unsheathed FRLS conductor multi stranded cable in green colour connected to common earth point and connected to earth dolly drawn through PVC rigid conduit 25 mm bore, heavy grade (ISI marked) with and including all accessories, fixed to concealed in walls/floor/ roof, etc complete all as specified and directed.Notes: (i) 2 run of 6 sqmm cable, one run of 6 sqmm earth cable and one run of PVC conduit shall be measured as 1Rm(ii) Separate conduit shall be used for each submain wiring circuit irrespective of numbers of wire |
| 11 | Supply and fixing MCCB 4 Pole, 415 V with fixed thermal and fixed magnetic release, 100Amps with breaking capacity 25 kA using suitable size Al thimbles complete all as specified and directed. |
| 12 | Supply and fixing GI tubing 40mm bore light grade ISI marked with requisite fittings laid in trenches or crossing roads/ paths/ culverts/ along poles walls complete all as specified and directed. |
| 13 | Supply and laying cable XLPE insulated armoured heavy duty electric cable with extruded insulation aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 Core laid under ground, fixed along wall through GI pipe under floor/road, complete all as specified and directed. |
| 14 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc. including getting out in any type of soil complete all as specified and directed. |
| 15 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 16 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. |
| 17 | M&L for sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. |
| 18 | Supply and laying sub class \"B\" bricks of old size (230x115x75 mm) or of size locally available ,laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 19 | Material and labour for cutting the PCC floor/road/wall not less than 15cm in depth and 15 cm in width for inserting Gi pipe upto 40mm dia for cable protection and making good the disturbed wall surface and matching with the existing surface specifications complete all as specified and directed. (Note: PCC work for road/floor repair to be measured and paid separately). |
| 20 | M & L for cement concrete type C-1, 1:3:6 using 20mm graded crushed stone aggregate for road/floor repair and leveling with existing surface of road/floor complete all as specified and directed. |
| 21 | M&L for earthing complete with G .l earth plate electrode 60 cm x 60 cm x 6 mm thick burieddirectlyinground (earth pit notless than 2.25 m deep below GL) with top edge of the plate not less than 1.5 mbelow the normal groundlevel connectedgalvanized earth lead wire 4.0 mm bymeans ofbolts, nuts, check nuts and washers of galvanizedironorsteelincluding necessary excavation& earth work in any type of soil, removing surplus soil to a distance not exc 50 M,including PCC chamber in PCC (1 : 2 : 4), type B1, using (20 mm graded stone aggregate), mild steel frame madeout of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl coverwith handle , watering arrangement with funnel internally secured with wire mesh with 20 mm dia lightgrade GI pipe for watering, 15 mm dia mediumgrade,Gl pipe for earth wire protection with and including alternate layer of charcoal dust and common salt. complete all as shown in electrical plate No 3connectedto DBs all as specified and indicatedincluding testingon completion. |
| 22 | S&F distribution iron board clad vertical DB double door 4 way with IP-43 protection and mechanical strength as IK-09, 250 A insulated copper bus bar for each phase, 2 Nos shrouded Neutral bar, 02 Nos earth bar and cable ties for cable management and polyuthrene gasket suitable for MCCB as incomer and SP/TP MCB\"s as outgoing including fixed flush in wall inlcuding cutting chases on wall and making good the disturbed surface complete all as specified and directed. (Note :- MCBs and MCCB will be measured paid separately) |
| 23 | S&F of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 24 | S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 25 | S&F ceiling rose surface bakelite 65 x 50 mm two to three terminals along with back plates complete all as specified and as directed. |
| 26 | Material and labour for point wiring for one ceiling/exhaust fan point controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and includingrigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and includingpressed steel sunken boxes , readily availableconcealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc. including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface all as specified and as directed. |
| 27 | S&FSwitch piano flush type single pole, one way 5 Amp, 240 Volts complete all as specified and directed. |
| 28 | M & L for cutting hole in brick/stone masonary wall and provision of PCC 1:3:6 for making proper suitable size of hole to matching with size of exhaust fan for proper ventilation including MS bolts 04 Nos forfixing exhaust fanall as specifiedd and directed.Note : (i) Rates are deems to be included to making the cutting hole smoothly and colour wash as per existing colour.(ii) Rates are deems to be including charges of hiring T & P, i.e. ladder square foldingand insurance of labour deployed, being holes are made to be at multistorey bldgs of different height . |