| 1 | Supply, Laying, jointing & testingin trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 4 core with all fixing & connecting accessories including taking down old unserviceable cable/service wire. |
| 2 | All as per Item No 1 here-in-before but 06 sqmm 4 core. |
| 3 | All as per Item No 1 here-in-before but16 sqmm 2 core |
| 4 | All as per Item No 1 here-in-before but16 sqmm 4 core |
| 5 | All as per Item No 1 here-in-before but25 sqmm 4 core |
| 6 | All as per Item No 1 here-in-before but35 sqmm 3.5 core |
| 7 | All as per Item No 1 here-in-before but 50 sqmm 3.5 core |
| 8 | Taking down old unserviceable flood light and supply and fixRGBW Flood lights 100W LED outdoor Flood Light Water proof - IP66 LEDlights with 120° wide beam light, focus light forEM installation fixed on poles and buildings, Short circuit & surge protection complete including ON/OFF switch (min 15 Amps) withPVC enclosure andfixing arrengement of flood light with suitable size of fastner/ clamp on wall / poles complete all as specified and directed by engineer in charge. Cat No HLFLD-99-100-4CDL-25D Make Halonix or equivalent in Philips / Bajaj / Crompton/ Havells. |
| 9 | Dismantling / removing ofold unserviceable MS/GI pipes any length and supplyand errect pole 4 mtr long,double armedPole tube made out MS pipe,base & embellishment casted, with PU coating of approved colour suitable for pendant light upto 60 W as per direction.The pole shall be mounted on RCC pedestalas per design and drawing prepared by the manufacturer all as specified and as directed by Engineer-in-Charge with following specifications:- (a) Top dia 76 mm(b) Casted dia 114 mm(c) Cement concrete 1:2:4 type B1 for foundations up of size 2\"x2\"x2\"PCC from ground level with proper fixing arrangments such as nut/bolts/washers over PCC work all as specified and directed.(d) The Rates for 2.5 Sq mm 3 core copper wire for light connction are included in quoted rates and quantity as per site requirement. Make-Halonix Cat No. HLOP-95-4M-114/76-ACB Make Halonix or same design in Philips / Bajaj / Crompton/ Havells. |
| 10 | Taking down old unserviceable streetlightsupply and fixing of energy efficient 60 W LED IP65 pendant mounting street light aluminium die cast with clear acrylic front cover suitable for high efficient assymetric secondary lens LM80 certified for higher power 240 V, lumen 100 lm/W and driver efficiency 85% with all accessories internally prewired and including connecting up with twin core copper conductor cable complete all as specified and directed.Make- HALONIX Cat No. HLOSL-04-60-WWL-01or same design in Philips / Bajaj / Crompton/ Havells. |
| 11 | Dismantling / removing ofold unserviceable bolard light any length and supplyand errect contemporary UFO shape designbollardlightwith minimum upward light componenetin die-cast aluminium bottom housing with decorative clear acrylic 10 watt and IP65 protection including necessary fixing arrangement like PCC foundation work and electric connection for all light as per site requirement complete all as specified and as directed by Engineer-in-Charge. Make Havells UFOBLS10W LED830PSYMTOPC and Surya Flash LED / Wipro LB12-131-XXX-65-08 Note :- The Rates for 2.5 Sq mm 3 core copper wire for light connction are included in quoted rates and quantity as per site requirement. |
| 12 | Taking down old unserviceable light fittings and supply and fix decorative Stellar LED post top lantern offering combination of sturdy design execllent illumination and aesthetics, IP 66 protection and IK 10 rating ensures it stands tall amid varied environmental conditionsincludingelectrical connection complte all as directed make Havells cat NoNEBULAPT40WLED857PSYMTOPC/ Wipro LP05-501-xxx-57-G2 or equivalents make or same design in Philips / Bajaj / Crompton/Surya. |
| 13 | Supply and fix in replacement junction box of size200 mmx 150mmx 100 mm mada out of FRP with double stud hinged door locking includingelectric connection for three phase incomming cable 3 phase out going cable and single phase connection for street light fitting incl controlled MCB SP-10 Amps -01 Nos with dinrail for mounting of MCB including suitable connector for looping duly sealed with rubber plugs.enclosed in thermo plastic inclosed shock proof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified.Make-of MakeFinole/Hensel/Sintex |
| 14 | Taking out old bracket from existing poles of 4/4.5 mtr height and supply and fix single arm MS with hot dip galvanised bracket duly pu coated in approved design, shape and length to compliment existing MS poles of 4 mtr with all necessary fixing arrangements duly PU coated of approved shade, all as specified and as directed by the Engineer-in-charge. The bracket shall be suitable for outer dia of existing pole. ( Havells Cat No Orbit Plus S Round arm pole or same type in all respect in/ Philips / Surya / Bajaj |
| 15 | Supply and fixing in replacementLED street light fitting 120 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete all as specified and directed |
| 16 | Supply and fix in replacement GI pipe bracket made out of medium grade 40 mm bore GI tubing duly bend to the required shape length of the bracket shall be not less than 1.5 m including MS flat iron clamps, nuts, boilts and washers for fixing of bracket on pole complete all as specified and directed. |
| 17 | Taking down old unserviceable light fittings and supply & fixing of energy efficient 45 W LED IP65 pendant mounting street light aluminium die cast with clear acrylic front cover suitable for high efficient assymetric secondary lens LM80 certified for higher power 240 V, lumen 100 lm/W and driver efficiency 85% with all accessories internally prewired and including connecting up with twin core copper conductor cable complete all as specified and directed.Make- HALONIX Cat No. HLOSL-04-45-WWL-01or same design in Philips / Bajaj / Crompton/ Havells. |
| 18 | Taking out old wall mounted bulkhed/surface fittings and supply & fix wall mounted LED light fittings triangular 10 watt capacity, 3000Kfor up and down light complete with all fixing arrangementsIP 65 all as directed by Engineer -in- Charge (Make - WIPRO Cat No LW23T-101-X-30-UDX or same in all respect in Philips/Bajaj/Crompton/Surya) |
| 19 | Taking down from poles light fittings of any type and supply and fix circular LED post top made up of Pressure die cast aluminium body and opal PC cover. IP 66 and IK07 45 watt, 3000K complete with necessary fixing arrangements(Make- Havells Cat No RINKPT45WLED757PSYMTOPC or same type in all respect in Philips/Bajaj/Crompton/Surya) |
| 20 | M&L forPVCinsulated unsheathed three core flame retardant cable (FR) of working voltage 1100 volts gradewith stranded copper conductorincluding 25 mm diaPVC rigid non- metallic conduit if required drawing through pipe or inserting through holes of poles from PVCjunction box to fitting including taking down / dismantling oldwiring including and old conduit complete all as specified and as directed. NOTE :(i) PVC three core cableand one run of PVC rigid non metallic conduit ( if rquired) shall be measured as one length). |
| 21 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable or for pole etc complete all as specified and as directed. |
| 22 | Excavation in trenches in Hard / Dense soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable or for pole etc complete all as specified and as directed. |
| 23 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed. |
| 24 | Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed. |
| 25 | Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed. |
| 26 | Supply and lay unreinforced Precast cement concerete cable cover for protection of under ground cable in trenches class LV type I of size 250mmX150mmX40 mm complete all as specified and directed |
| 27 | M&L for cutting of Hardstanding/ road by mannual method upto 200mm deep for inserting GI pipefor cable protection complete including ready mix concreate and making good distrubed surfaceall as specified and as directed. |
| 28 | Boring of hole horizontaly 80 mm dia for under road/hard standing area / foot path for laying/crossing of cables including making good road/hard standing area/foot path and road shoulder etc all as specified and as directed. |
| 29 | Supply & Laying GI pipe light grade 80mm bore for cable protection with all fittings for passing the under ground HT cable under road crossing along poles walls and floors including taking down old pipecomplete all as specified and as directed. |
| 30 | Supply & Laying GI pipe light grade 50mm bore for cable protection with all fittings for passing the under ground HT cable under road crossing along poles walls and floors including taking down old pipe complete all as specified and as directed. |
| 31 | Supply, install, test and commissioning of free standing floor mounted, dust and vermin proof automatic timer switch box panel board, outdoor type, fabricated with 2.0 mm thick SS 316 Sheet mirror finished internally and externally. Panel shall be front openable with double stud hinged door & locking arrangement and provided with suitable size of TPN bus bars of high conductivity copper alloy and shall be provided with colour coded heat shrinkable sleeves. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:(a) ML-4 Contactor, TP, 70 Amps, 415 Volts, 50 HZ - 01 Nos(b)Digital timer switch 20 Amps capacity - 01 Nos (c) MCCB, TP, 63 Amps, 415 Volts, 50 Hz, 10 KA Breaking capacity - 01 Nos [Incoming] (d) MCB, SP, 32 Amps, 240 Volts, 50Hz, 10 KA - 6 Nos |
| 32 | M&L for Conductive Concrete Earth Grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less than< 5 Ω. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under:-(i) Earth Electrodes: Metal conductor - Copper bonded MS rod dia 17.2 mm(+/-.5mm),Length 2.25 meter with conductive concrete including provision of bore85mm to 100 mm dia,3meter Length of earth electrode. (ii) All earth electrodes(min two nos) should be installed to achieved the desired result .(iii)Interconnected Strip: All the multiple Earth Electrodes will be horizontally interconnected with metal conductor - Copper strip flat size : 25mm x 3 mm &conductive concrete embedding size : 60 mm².(iv) Test Link : Test links - Copper strip flat size : 40 mm x 6 mm x 200 mm shall be provided,at any one of the multiple Earth Electrodes of the grid for connection between earth grid pit and application.(v) PitCover : RCC pit cover & frame shall be provided at all Earth Electrode (with test links). Note :- (a) Bidder shall produce certificate for resistivity of conductive concrete.(b) Fault Current Testedat 35 KA Peak With 17.2mm copper bonded rod .(c ) On completion of work Engineer in charge will check the earth resistance in presence of user, Contractor will re-do the earth if earth resistance value is more than 5 Ohm if value not found as per contractthe necessary action to be taken by the contactor for achieving the desire result. The contactor will maintain value upto min 5 year(d) All connecting strips would be of copper of size 20x3 mm and cost of the same is included in the rate quoted, upto test point.(e) Test certificate of earthing material for ROHS compliance, Resistivity value and fault current test for electrode from certified NABL laboratory shall be submitted. (f) Contractor will annually check the resistance value of earth grids after completion of work (g)The vendor to provide CPRI test report for current greater than 20 KA with peak at 38 KA, The report shall not be more then 5 year old from the date of tender. (h) The product should be ROHS compliance. l)The earthing to be carried out by OEM only.The MOU in thisrespect to be submitted by contractor while quoting the contract. |
| 33 | Provn of Chain Link Fencing with excn in post holes (or similar holes) each n.exc. 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil and making surface good in soft / loose soil.Cement concrete in foundations, filling and mass concrete in type C-2 1:3:6 (40mm graded aggregate). Rolled Mild Steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 290 Gde E-165. MS screw bolts ( machine made) with hexagonal or square head at one end screwed the other end or screwed both ends.Each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n.exc. 10 cm.50x50mm mesh size for covered theE/M installation/substation of 24 m length and 2.1m high with 4mm GI wire incl 04 Nos of 10mm dia tie round bars, securing with 12mm dia 100mm long botls @ 04 Nos at each post alongwitg 50x6mm FI with 5 Nos of 65x65x6mm angle iron post embedded in PCC 1:3:6 of foundation size of1.2x0.50x0.60mand provision ofFramed work as in doors or Gates of Angle or other section with gusset plates, Rails, braces etc complete including drilling for fixing of steel sheeting or other covering also fastening and fixing complete of Grade Fe 410-O MS steel gate of size 2.0 x 2.0m, bottom portion covered with 1.60mm thick MS bleck sheet and painting work for fancing and gate with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge. |
| 34 | Taking out old unserviceable gate lights and supply & fix LED post top suspended lantern made up of spun aluminium canopy with die-cast aluminium spigot. Fitted with glare free optically designed prismatic diffuser and high efficiency LEDs of 30 watt, 3000-4500k complete with fixing arrangements on existing gate pillars all as specified and as directed by Engineer-in-Charge. (make- Surya Cat No SLEPT30W-VEGA or same type in Philips/Bajaj/crompton/Havells) |
| 35 | Taking out old unserviceable change over switch and Supply and fix Automatic Change over switch / Automatic transfer switch in sheet steel enclosure duly powder coated of Capacaity 200 Amps, 4 pole with complete protection, controller andhaving provision of manual operation also suitable for 415 volt , 50 Haz AC supply. The ATS shall be fixed on wall on a angle iron frame made out of angle iron 50x50x6 mm angle and cable end boxes on top and bottom (the height of cable end boxes shall be minimum 450 mm) all as specified and as directed by Engineer-in-Charge |
| 36 | Taking out old unserviceable MCCB and supply and fix MCCB TP, 415 Volt, 400 amps rup capacity 36 KA (Ics=100%Icu) including all necessary fixing arrangements such as nut bolts washers, links etc |
| 37 | Taking out old unserviceable MCCB and supply and fix MCCB TP, 415 Volt, 630 amps rup capacity 50 KA (Ics=100%Icu) including all necessary fixing arrangements such as nut bolts washers, links etc |
| 38 | Taking out old cross arms/support from poles and M&L for cross arams, bracing supports clamps and back plates fabricated from structural steel section including nut bolt washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and as directed by Engineer-in-Charge. |