| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for taking out/laying pipes in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling, including spreading levelling watering and well ramming in layers not exceeding 25cm thick in solf/loose soil after pipes are laid and tested complete all as specified and directed. |
| 3 | Removing of excavated material not exc 50 mtr distance and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Supply only high density synthetic float ball of size 6\" (150 mm)with double hook for suction sweeper complete all as specified and directed. |
| 5 | Supply only flexible hose piperibbed type high density of 40 mm size complete all as specified and directed. |
| 6 | S&F nylon brushwith superior quality of any size made out of water resistant wooden block with thickly insert nylon strings for using sweeping complete all as specified and directed. |
| 7 | S&F nylon rope 12 mm for the suction sweeper complete all as specified and directed. |
| 8 | S&Faluminimum alloy telescopic rod , top dia 30mm and bottom dia 28 mm with detachable superior quality brush ISI markedof size 6 mtr expanded upto 12 Mtr for brushing the entire area of swimming pool complete all as specified and directed. |
| 9 | Supply only poly aluminimumcloride (PAC) COAGULANT CONTAINING APPROX 29% Al2O3 with bacity of approx 64% packed complete all as specified and directed.Note: For Sl item 9 to 13, 15 and 18 labour cost for mixing shall be included in quoted rate by the contractor. |
| 10 | Supply only Sodium Hypo Cloridehaving chlorine content (10-11%) in manufacturer standard packing complete all as specified and directed.Make:- Jalaqua/Declibac/Hi-bird |
| 11 | Supply only Copper Sulphate complete all as specified and directed. |
| 12 | Supply only Soda Ash complete all as specified and directed. |
| 13 | Supply only Chemi coat, Algae-cide liquid for swimming pool complete all as specified and directed.Make:- Jalaqua/Declibac/Hi-bird |
| 14 | Supply and fixing in replacement High pressure guage circular dial up to 5 Kg/Sq.cm confirming to IS complete all as specified and directed. |
| 15 | Supply only Ortho- Toliding solution for testing of disolved chlorine in water complete all as specified and directed. |
| 16 | Supply and fixing in replacement superior quality detachable type telescopic brush suitable for telescopic rod of 30mm dia (bottom 28mm dia) complete all as specified and directed. |
| 17 | Supply and fixing in replacement leaf net for removing floating particles from both swimming pool surface every day in the morning and evening time complete all as specified and directed. |
| 18 | Supply onlychlorine testing kit comprising of samples of chlorine contents in seald tube from 0.1 to 2.0 PPM and othotodoline solution, testing tube complete all as specified and directed. |
| 19 | Supply & Pouring Calcium based high strength granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution, free of foriegn matter, the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. |
| 20 | M&L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 200 Amps 4 pole 35/36 ka, One Nos 100 Amps 4 pole 25 ka, One Nos 63 Amps 25 ka as outgoing, 4 DOL Starter for operating 5 HP monoblock Pump,Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC workas required at site complete all as required at site or directed. |
| 21 | S&F of high rate pressure sand filters bobbin wound fibre glass reinforced laminated filter of 1200 mm with UV resistant surface finish, reliable to operate under prolong sunlight for years, designed for easy inspection of quartz filter media with a six position, 50 mm multiport valve and ABS lateral with quartz filter media complete with all required materials incl dismantling of old, all materials as required at site, fixing arrangements and testing on completion complete all as specified and directed. Make:- Poolbudy/Aquaviz/Hi-bird |
| 22 | M&L in replacement of swimming pool pump having input 2.18 KW rated voltage 380-400V frequency 50 Hz min Head 8.5 mtr and discharge 30.4 m3/h complete all as specified &directed. Make:- Crompton/KSB/Varuna/Kirloskar |
| 23 | Supply & fixing in replacement sluice valves 150 mm dia class PN-1.6 , IS-14846with flanged ends, stainless steel spindle and iron wheel includingnut boltsand rubber packing complete all as specified and directed. |
| 24 | S&F in replacement of 150 mm bore non return valve both end flanged suitable for cast iron pipe including all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 25 | Disconnecting, dismaantling and taking down CI/GI/DI/Cemented pipe line of size 100mm bore,including all fittings with spigot and socket/ flanged end or any type, lead joint including removing from site complete all as specified and directed. |
| 26 | M&L in replacement of ductile iron pies 100mm bore incl rubber gasket joints and other relative accessories, class K-7 in any length laid in trenches complete all as specified and directed. |
| 27 | All as per item No 26 above but of size 150 mm complete all as specified and directed. |
| 28 | M&L for Cast iron/ductile iron special fittings for spigot and socketed pipes such as bends (any type, radius and angle) socket tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch,Y junction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore pipes complete all as specified and directed. |
| 29 | M&L providing PVC flat copper conductor cable 6 Sqmm 3 core multi stranded connected with suitable for pumpsand required copper thimbles and nut bolts to panels including taking out the existing unserviceable cable complete all as specified and directed. |
| 30 | S&F of swimming pool splash pump with 3 HP motor built in strainer asynchronous, two poles class insulation 130 IP x 5 water proof standard overload protector built in thermal protection, heavy duty with ultra performance to both high and medium head installations, non corrosive materials using NSK bearing, external heat sink to ensure maximum cooling capability, specially made union to incorporate both metric & imperial measurement standard complete all as specified and directed. Make:- Crompton/KSB/Varuna/Kirloskar |
| 31 | S&F in replacement of Motor 230 volt, 50 Hz, voltage input 230 volt single phase 50 Hz, current consumption 0.4 Ampr power 120 watt, speed 4 pole induction non synchronous 920 RPM Approx under lead motor shaft dia 15mm X Length 50 mm motor is flange mounted 4 no of 7 mm dia hole at PCD 150 mm incl all fixing arrangement complete all as specified and directed.Make:- Declibac/Jalaqua/Aquafit |
| 32 | S&F in replacement of shaft complete with impeller made out of MOC poly propelene rigid dia 32 mm X Length 500 mm impeller type two bladed pitched blade turbine numbar of impeller- I incl all fixing arrangements complete all as specified and directed. |
| 33 | S&F in replacement of Dosing tank only capacity 100 Ltrs MOC PE FRP Ltd contaning port hole for pouring chlorination chemical and water them necessary provision for mounting of moteo at proper angel provision for mounting dosing pump on lid level gauge complete all as specified and directed. |
| 34 | S&F in replacement of Rotor assembly with bearing brackets & tolerance ring complete all as specified and directed. |
| 35 | S&F in replacement of Single head feet rate control with shaft complete all as specified and directed. |
| 36 | S&F in replacement of Pump head ( ferrules 1/4\"\" & duchbill included) complete all as specified and directed. |
| 37 | S&F in replacement of Pump tube complete all as specified and directed. |
| 38 | S&F in replacement of Injection check valve complete all as specified and directed. |
| 39 | S&F in replacement of Weighted suction line strainer 3/8\"\" complete all as specified and directed. |
| 40 | S&F in replacement of 3/8\"\" white suction/discharge tubing complete all as specified and directed. |
| 41 | S&F in replacement of Check valve duckbill only (PK-5) complete all as specified and directed. |
| 42 | S&F in replacement of Gear motor complete 230 volt 50 Hz complete all as specified and directed. |
| 43 | S&F in replacement of Coil 250 volt 50 Hz complete all as specified and directed. |
| 44 | S&F in replacement of Roller Assembly complete all as specified and directed. |
| 45 | S&F in replacement of dosing pump ( Model No 96 NGQ 51) high pressure single head geared motor adustable dosing having output upto 40 US GPD and pressure upto 7 kg/cm2 with connecing accessories complete all as specified and directed. |
| 46 | Supply & Laying, jointing and leakage testing GI tubing medium grade 15mm bore with all fittings such as bend, tee, elbow, union, reducer etc, laid in trencheS&Floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and directed. Make: Tata/Jindal/Prakash Surya as approved by GE(I).Notes :(i) The laying and jointing of pipes are required to be carried out in short/ long streches catering to specific requirements of a purticular quarter or a group of blocks.(ii) Excavation & earth work shall be measured & paid seperately. |
| 47 | All as per item No 46 above but of size 20mm complete all as specified and directed. |
| 48 | All as per item No 46 above but of size 25mm complete all as specified and directed. |
| 49 | All as per item No 46 above but of size 40mm complete all as specified and directed. |
| 50 | All as per item No 46 above but of size 50mm complete all as specified and directed. |
| 51 | S&FEmergency LED Batten gets automatically switched on during a power cut and runs effectively upto 4 hours having rated wattage 20 Watt Lumen (AC)2000 Lumen (DC) 500 PF> .9 Colour temperature 6500 K CRI>80 protection class IP 20 Complete all as specified & directed. |
| 52 | S&F in replacement flood light 150 watt with pressure die cast IP66 housing, secondary lens with 120 lm/W efficacy and superior asthetics suitable for various applications complete all as specified and directed. |
| 53 | M&L for construction of valve pit chamber in replacement950 x 950 x 950 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick,PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces including dismantling and removal of old unserviceble valve pit remains complete all as specified and directed. |
| 54 | M&L for structure work fabricated from structural , steel section including nut,bolts,washers including cutting/ weldingin any position, any shape and drilling hole for bolts in any size and shape as per site requirement or directed and inclusive of one primer coat of red oxideand one finish coat of synthetic enamel black paint complete all as specified and directed. |
| 55 | M&L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron framefixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 KA, four Nos 100 Amps 4 pole 25 KA, two Nos 63 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as specified and directed. |
| 56 | M&L for Earthing complete with GIplate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. |
| 57 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed. |
| 58 | M&L for point wiring for one light point/fan/ exhaust point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLSH with proper colour coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green colour) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed. |
| 59 | All as per item No 58 above but for one 3 pin 15 Amps socket outlet independentwith 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed. |
| 60 | All as per item No 58 above but for one socket outlet 5 amps on independent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed. |
| 61 | All as per item No 58 above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed. |
| 62 | M&L in replacement forsubmain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. |
| 63 | M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed. |
| 64 | S&F switch modular type one way 1 module 16 amps 230 Volts complete all as specified and directed. |
| 65 | M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts complete all as specified and directed. |
| 66 | M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed. |
| 67 | M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed. |
| 68 | S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed. |
| 69 | S&F of LED Aluminiumbatten luminaire surface mounted 4 feet system wattage of 20/22 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained.CRI>80, Power Factor>.95 ,THD<20% ,Surge protection 3 KV in CM, IP-20n Protected , meets LED IS Specifications , Class-1 , short circuit and over circuit protection voltage range-150 to 270 AC,system efficiency at luminaire level > 100lumen/watt and ibncluding connecting up with pvc sheathed 1.5 sq mm 3 core copper conductor flexible wire from ceiling rose to fitting fix complete all as specified and directed. Note:- All the above mentioned specifications will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures. |
| 70 | S&F LED in repair wall security light 20/25 W pressure die cast aluminium IP-66 road way luminaries with high power LED as light source having efficacy 120 lm/W complete all as specified and directed. |
| 71 | S&F distribution board iron clad, double door with IP-43 1K-09 protection suitablefor MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, complete with one MCCB 4 pole 415 Volts 125Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed. |
| 72 | Supply and fix sheet metal enclosure MCB distribution board,8way double door with IP-43 protection with 200 Amp rated bus bar complete all as specified & directed. |
| 73 | S&F amp rating 240 V, 10 KA \"C\" curve miniature circuit breaker (MCB)of SP 5 to 32 Amps and Current carrying capacity in the MCB DB with connection testing and commissioning complete all as specified and directed. |
| 74 | All as per item No 73 above but SPN 40 to 63 Amp complete all as specified and directed. |
| 75 | Dismantling & taking down old exhaust fan & deposit in MES Store yard &Supply and fixing of Exhaust Fan AC single phase 230/240 volts of size 450 mm sweep with louver shutter complete including providing/cutting the round hole of required size in wall, grouting of nuts, bolts,fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduitfrom celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etccomplete all as specified and directed. |