| 1 | Schedule \"A\" Part-I (Repair and maint of Gang Operated Device) |
| 2 | Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball, nuts, washer etc. as required |
| 3 | Repair/ maint of existing Gang operated device including insulator male female , operator rod , back clamp replacement of wornout UNSV spares and installation, commencing as per directed by Engineer-in-charge |
| 4 | Supplying and fixing straight through cable jointing kit with heat shrinkable kit with ferrules for 3½ X 95 sq. mm 1.1 KV grade cable |
| 5 | Schedule \"A\" Part-II (Repair of power house control panel) |
| 6 | Supplying, fabrication, testing and commisioning of feeder pillar of cubical outdoor type type with rain ravelling type of size 750mm x 600mm x 250 mm construction, floor mounted type fabricated out of 2mm thick CRCA shee, compartmentalised with hinged lockable doors, dust and venium proof, powder coated of approved shade i/c electrical accessories, alluminium lugs with lead complete for drop down cable and angle channel stand in cement concrete foundation, inter connection, having metal enclosure including fixing clamp, 63 amp DP MCB |
| 7 | Supplying and fixing of 200 amps. TPN, rising mains in metal enclosure with aluminium busbar including fixing clamp |
| 8 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 36 KA, FPMCCB |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415, 10 Ka, C curve, miniaturecircuit breaker for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required.Single pole and neutral |
| 10 | Supplying and fixing cable End Box (Loose wire Box suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and comissioning etc as required.For 10 way, double door SPN MCBDB |
| 11 | Supplying and wiring of 6.0 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 12 | Schedule \"A\" Part-III (Repair maint UG cable) |
| 13 | Supplying and fixing LT overhead lines on 9 meter steel tubular poles with XLPE insulated AB cable 95 sqmm 3.5 core |
| 14 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres |
| 15 | Supplying and fixing straight through cable jointing kit with heat shrinkable kit with ferrules for 3½ X 95 sq. mm 1.1 KV grade cable |
| 16 | Supplying, fixing and commencing of Aluminium lugs for 70 sqmm and 95 sq. mm |
| 17 | Schedule \"A\" Part-IV (Transformer Safety enclosure and earthing) |
| 18 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m all kind of soil. |
| 19 | Providing and laying in position specified grade, excluding the cost of centering shuttering, finishing and reinforcement - All work upto plinth level: 1:3:6 ( 1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes |
| 21 | Supplying and fixing of galvanised steel barbed wire of 9.8 kg/100metre. |