| 1 | Supplying & drawing following sizesof FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required 3 x 1.5 sqmm |
| 2 | Earthing with GI earth pipe 4.5 metre long ,40 mm dia including accessories,and providingmassonary encloser with cover plate having locking arrangement and watering pipe etc. with charcoal /cock and salt as required. |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sqmm |
| 5 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm |
| 6 | Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required. |
| 7 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting outthe excavated soil and disposal of excavated soil as directed within a lead of 50 metres |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | S/L of following size DWCHDPEPipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,partII complete with fittingand cutting ,jointing etc .direct in ground (75 cm below ground level )including excavationand refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 11 | Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. l/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and l/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor 4 nos. & shorting links on DIN channel l/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB \"C\" Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS code etc as required. |
| 12 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm (W) and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia-960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia1400 mm (approx) -6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m to 5 mtr pole. |
| 13 | Fabrication, supplying and fixingclass B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required. |
| 14 | Supply of XLPE insulated, PVC sheathed Al. Conductorarmoured cable 1.1 KV grade confirmingto IS-7098 of following Size (a) 2 X 6 Sqmm. |
| 15 | Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required |
| 16 | LED Streetlight fixture, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&CommissioningofStreetlightLED fixture, powdercoated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage:140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP 66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMI EMCasper CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K /4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) 45 Watt |