| Sl. No. | Item Description |
| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres leadOf area 3 sq. metres and below |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres leadOf area beyond 3 sq. metres |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 7 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50metres lead. |
| 8 | Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead :Thickness up to 40 mm |
| 9 | Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead :Thickness above 40 mm up to 75 mm |
| 10 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :75 to 80 mm dia pipe |
| 11 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe |
| 12 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore |
| 13 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :Above 40 mm nominal bore |
| 14 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:Up to 150 mm diameter |
| 15 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 16 | Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. |
| 17 | Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead :120 x 120 cm (outside to outside) |
| 18 | Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead :210 x 120 cm (outside to outside) |
| 19 | Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead :320 x 120 cm (outside to outside) |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 21 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 22 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 23 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for :Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 27 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars atevery third course of half brick masonry. |
| 28 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) |
| 30 | 20 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 31 | 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) |
| 32 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 33 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 34 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 35 | Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge. Wooven PVC cloth |
| 36 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 37 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 38 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 1200 mm |
| 39 | Glazed vitrified floor tiles polished finish of sizeSize of Tile 600 x 1200 mm |
| 40 | Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 1200 mm |
| 41 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 42 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. |
| 44 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 45 | Providing & Fixing Herring Boon of ENGINEERED WOODEN FLOORING Panel 540x90mmTotal thickness 15 mm , 99 kg Toplayer PEFC controlled sources EN 13489 ± 3 mm Core board PEFC controlled sources Spruce Backing layer PEFC controlled sources Wood Veneer 2 mm Tongue and groove Length Uniclic Width Uniclic Multifit Domestic use Conditions in each pack 33 years Uniclic - Multifit connection Lifetime Commercial On request \"Wood for Life\" Edge Protect + Provides a warranty on build-up of residue dirt along the edges due to maintenance over the years 5 years \"Wood for Life\" Surface & Edge Protect + (lacquered products only) Provides a warranty on pollution of surface structure and a warranty on build-up residue dirt along the edges due to maintenance over the years 10 years Surface layer Wood species Oak Origin Europe Finishing UV cured Oiled finish 2 layers UV cured Lacquer Anti-scratch top coat 5 - 7 layers Natural variance Due to nature, visual surface can deviate from samples Surface treatments cf catalogue/website Nature Marquant Vibrant General aspect of installed EN 13489 Lipping - difference in height (mm) ≤ 0,20 difference in width (mm) ≤ 0,20 cupping lengthwise % ≤ 0,1 cupping in width % ≤ 0,2 Dimensional stability ISO 24339 Cupping short side max % ≤ 0,30 Changes 30 - 85 % RH Cupping short side min % ≥ - 0,20 Open joints short side (mm) ≤ 0,20 Open joints long side (mm) ≤ 0,30 Underfloor heating Suitable of special installation instructions or its equivalent. ( Basic rate of Engineered wooden floor panel is Rs. 650 per sqft) |
| 46 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 47 | Providing and fixing Access raised floor FS 1000Hpanel and alsopoint load of 450 kg and UDL of 1670kg sq-m2 panels manufactured from steel with lightweight cementitious core in the size 600 X 600 X 35mmThe top panel shall be finished with high abrasion, anti-static High Pressure Laminate1.2mmwith PVCbeading on all sides to provide protection of edges. The bottom of the panel shall be embossed in hemispherical shape to give strength and flexural rigidity. The entire panel shall be finished with electro deposition of cathodic epoxy paint on the exposed surface for lifetime protection and shall be Zinc Whisker free. All specifications must be printed on the panel side to ensure zero ambiguity.Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. Pedestal base to be permanently secured to portions on sub-floors, pedestal assembly shall provide easy adjustment of leveling and accurately aligned panel to ensure lateral resistance. It shall be designed to avoid any rattle or squeaks. It consists of 100x100x2mm thick galvanized base plate die pressed orbitally riveted to 24mmOD x1.2mm thick G.I./epoxy coated pipe to engage, the pedestal head assembly consisting of 75mmx75mmx3.5mm embossed ribbed head with four holes with steel pin for panel location for fasting and locating of tiles , mechanically locked to corresponding threaded stud 16mm dia OD and which is designed to engage the pedestal base assembly, the assembly shall provide a range of a height adjustment up to 50mm with the help of two check nuts . Pedestal shall be permanently fixed to sub floor by application of pvc gity with screw to achieve a Finished Floor Height 150mm to 1200mm FFHStringers system is all steel constructiongalvanized rectangular snap lock channel 570x20x30x0.80mm thick having notches for snap locking stringers topedestals pre-punched counter sunk holes are provided at both ends for securing the stringers on to the pedestal head ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electricalconduits and wiringetc.400 mm Finished Floor Height (FFH). |
| 48 | Providingandlayingof2 mm thickANTISTATIC/ESD Flooring with calendered laminated solid, unbreakable and flexible PVC flooring of a high wear resistance and resilience, with no asbestos contain. Flooring should have high vinyl content to have increased resistance to abrasion, scratching, soiling and scuffing as per Techinical specifications.(The product should conforms to BS: 2050-1978 & IS-3462-1986 with surface Electrical Resistance- Antistatic Flooring: 5x 10^4 to 5x10^8 Ohms and Conductive flooring range upto 5x10^4 Ohms.) |
| 49 | Providing & Fixing 100mm thick stud partition which includes double layer of tapered edge 12.5mm thick Fireline (conforming to IS 2095 Part 1:2011, Certified board) of size 1219x2438mm is screw fixed to C-stud. 48x0.5mm C-stud {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610mm c/c in 50x0.5mm. {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} floor and ceiling channel. Floor & Ceiling channel is anchored to the floor & True ceiling using Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti anchor fasteners at 600mm c/c in centerline. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. 12.5mm thick Fireline strip of 50 mm width is placed between ceiling channel and RCC ceiling slab to improve fire performance of the system. A noggin channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of the two boards. First layer of boards to be screw fixed with drywall screws of 25mm at minimum spacing of 600mm at centre and 600mm at periphery. Second layer to be screw fixed drywall screws of 35mm at minimum spacing of 300mm at centre and 300mm at periphery. 25mm glasswool slab of density 20kg/m³ shall be placed in metal framework. Glasswool holding clip should be used to hold Glasswool slab in its position. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Joint Paper tape or fiber tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant. (Note: Areas for artwork, LED TV mounting, display shelves, Storage to have ply backing of required thickness to maintain same face and shall not measured separately)Note: All the ply used to be fire resistant ply. All the wooden members being used in the partition to have fire retardant paint. Areas for artwork, LED mounting, display shelves, lacquered glass, laminate / veneer, acoustic panels etc to have ply backing of required thickness to maintain same face and shall not measured separately. |
| 50 | Single Glaze Glass Partition for 13.52mm laminated Toughened Glass.Supply & Installation of approved make Aluminum profile with profiles size 105mm x 25mm in Natural anodized / black finish. The glass to be fixed with suitable gasket for insertionof 13.52mm thick laminated toughened glass (6mm+PVB+ 6mm).Partition glass joineries consists of two-way Polycarbonate I-profiles, 90 Degree Polycarbonate L-Junction and Polycarbonate T-Junctionprofiles. Polycarbonate profile joineries to be fixed with double sided adhesive tape & profiles to be inserted in the joint instead of sealing itwith sealants. Polycarbonate profiles to be used to give continuity glass effect. Hardware for fixing profiles to be used as per manufacturer standard. |
| 51 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including powder coating required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | Providing and fixing HDHMR (High Density High Moisture Resistant) board of 850kg/m3 density, tested for gross heat of combustion in accordance with ISO 1716, termite and borer proof, manufactured by an ISO 9001 (QMS), ISO 14001 (EMS), and ISO 45001 (OHSMS) certified company, complete in all respects as per manufacturer’s specification and to the satisfaction of the Engineer-in-Charge.HDHMR Board18mm Thk. (Base rate of board is Rs.148 per sqft) |
| 54 | Providing&FixingFrostedTranslucent,castPVC, self-adhesivevinyl,specialCRYSTAL-effectfilmto reproduce Sand-blasting effect on glass with customiseddesigns,thicknessof2mil(0.05mm) without adhesive & 3mil (0.8)with adhesive having minimum tensile strength of 3.5 pound/inch at 73 F(0.6kg/cmat23C).Adhesionafter24hrsof installationshouldbe4pounds/inch(0.7kg/cm) onAcrylic,GlassPolycarbonate:MCSwarranty of 3yrs (if exposed to direct sunlight) to 15yrs (indoors)mustbeendorsedby3MIndiaLimited ArchitecturalMarketDepartment.Contractors payment wouldn\"t be released until & unless he/she produces orginal warranty certificate from the manufacturer. ( Base rate of film is Rs.240 per sqft) |
| 55 | Providing and Installing WPC FLEXIBLE fluted panel for curvilinear areas of thickness from 6mm to 12mm as per approved design over and above existing finished base. as per site requirement with all accessories,corners and fitting complete in all respect as per the direction of engineer in charge. ( Basic Rate of wpc fluted panel is Rs. 295 per sqft ) |
| 56 | Lacquered Glass Panelling : Providing and fixing6mm thick lacquered glass (matte lacquered glass, some in satin finish, mettalic, textured , printed lacquered glass in the basement , if required)panelinghaving 12mm thick ply / mdf backing over existing surface as per detail drawing. The glass edges to machine polished & fixed with natural silicon sealant of Dow Corning or approved in joints complete as per design and drawing. ( Base rate of lacquered is Rs.850 per sqft). |
| 57 | Providing and fixing minimum 2.0 mm thick heavy-duty decorative laminated sheet lining over existing base as per approved design and pattern, conforming to IS 2046, with synchronised texture (syncro lam), manufactured using FSC-certified kraft paper and UV Grade 7 paper, having density not less than 1.37 g/cm³, of approved shade, including the cost of approved quality adhesive and matching edge band to be supplied and fixed by the manufacturer, tested for gross heat of combustion in accordance with ISO 1716, with the manufacturer certified under ISO 9001 (QMS), ISO 14001 (EMS), ISO 45001 (OHSMS), and FSC certification, complete in all respects as per manufacturer’s specification and direction of Engineer-in-Charge.( Base rate heavy-duty decorative laminate sheet is Rs. 300 per sqft). |
| 58 | Providing and fixing machine cut, mirror/ eggshell polished , Marble stonework for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. |
| 59 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby redArea of slab upto 0.50 sqm |
| 60 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 61 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 62 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete. |
| 63 | Providing and fixing of Wallpapers adhesivesComposition : water-based ink printed vinyl coating, cotton backing. Weight : ± 350 gr/m², ± 15 oz/yd¹. Width : ± 130 cm, ± 51 inches.Flame Retardancycertifications : EN 13501, B s1 d0 / ASTM E84, A / NFPA 286. Sound absorption certifications : ISO 354, alphaw 0.10. Vinyl + Certified.( Basic rate of wallpaper is Rs.200 per sqft ) |
| 64 | Providing and fixing fabric-faced acoustic cladding system to wall/column/partition surfaces, consisting of stretched fabric finish over an acoustic infill mounted on a rigid framework, as per drawings and manufacturer’s specifications.Framework: 48 mm GI C-Studs (0.55 mm thick, flanges 34 mm & 36 mm) fixed at spacing not exceeding 600 mm c/c, with 50 mm floor and ceiling channels (0.55 mm thick, flanges 32 mm each), and 99 mm fixing channel (0.9 mm thick with two flanges of 9.5 mm each) at horizontal joints. Framework securely anchored to wall/column/partition/floor/ceiling using galvanized screws and plugs.Base Layer: 12 mm thick BWR grade plywood fixed on outer face of framework to receive acoustic infill.Acoustic Infill: 25–50 mm thick resin-bonded glass wool / mineral wool / PET wool (density 48–64 kg/m³), NRC ≥ 0.80, fitted tightly within framework cavities.Fabric Finish: Approved make, colour, shade and texture of acoustic stretch fabric (fire-retardant, fade-resistant, acoustically transparent), stretched taut over proprietary track system or adhesive fixing method, ensuring wrinkle-free surface and neat alignment at edges and corners.Joints & Detailing: All fabric edges tucked into track channels or neatly overlapped, with provision for cut-outs for electrical/network points, switches, light fixtures, skirting, and other services as shown in drawings.The work shall be executed complete in all respects including all materials, labour, adhesives, screws, framework, fabric, infill, polishing/finishing, scaffolding, and surface protection till handover, as per approved samples and instructions of Architect/Engineer-in-charge.Performance Requirement: NRC ≥ 0.80 (lab test certificate to be submitted). |
| 65 | Providing and Fixing of GRC Jali (Glass Fibre Reinforced Jali) 50 mm thick of required size, pattern, design, and colour with 50% area covered to be fixed on/between RCC / Block work Column or structural steel work with Dry Fixing method. Fixing of(Glass Fibre Reinforced Jali) GRC Jali to be fixed on/between RCC / Block work Column or structural steel work with Dry Fixing method withappropriate steel frame work , usingfasteners, and necessary hardware etc in Building Facade. The jali shall be securely fixed with stainless steel bolts and anchor fastners(304 grade) of required size at specified locations. The fixing shall be done by the specialized approved agency as directed by Engineer-in-Charge. |
| 66 | Providing and applying of min. two or more coats of ISO 9001:2015 and Z.E.D certified,premium, high-performance nitrocellulose-based + tiny metallic flakes (reflective particles) Evg. Duco coating system of approved make with wet film thickness (WFT) of 20 microns per coat and coverage 11.15 m²/liter/coat. It should be engineered for an exceptionally smooth, mirror-like finish with high scratch, chemical, and stain resistancesuperior chemical resistance, extreme durability, industrial-grade performance, UV resistance, anti-yellowing durability, self-Leveling FlowCoat, should dry in min. 45 minutes after application, min. 1500 SCR and industrial-grade protection, making it ideal forwood and metal. The paint should have min. 7 years of warranty and Hydro-Repel Technology in it for it to long last on surface. The base should be prepared by filling the gaps and cracks by filler putty followed by applying a clear sp. nitrocellulose-based primer to fill the holes then followed by 2-3 coats of evg. duco enamel as per the manufacturer or OEM guidlines. The paint hsould have a min. of 7-years performance warranty on color retention, gloss stability, and film integrity. All components must be from the same manufacturer to ensure the quality of the material. An authorization letter from the OEM must be submitted before execution or as per the direction of the Engineer-in-Charge. |
| 67 | Providing and fixing single extruded PVC louvers of approved colour for ceilings, interior wall panelling, etc. The louver base and PVC film shall be 100% manufactured in India. The wall thickness of the louver should be minimum 2 mm while the base wall thickness should be minimum 3 mm. The composition shall include virgin polymer, calcium carbonate, natural fibres (such as wood powder, rice husk, or wheat husk), and non-toxic additives. Having Class A category resistance to spread of flame criteria, and tested for gross heat of combustion in accordance with ISO 1716. Additionally, the louvers must be termite/borer proof, water/moisture proof, and fire-retardant.( Basic rate of PVC Louver is Rs.550 per sqft). |
| 68 | Providing and Installing PVD coated SS transition profiles of thickness ranging from 0.8 mm to 1.5 mm on wall or floor with width upto 25mm as per design and approved drawings. T Profile |
| 69 | Providing and Installing PVD coated SS transition profiles of thickness ranging from 0.8 mm to 1.5 mm on wall or floor with width upto 25mm as per design and approved drawings.Corner protection profile |
| 70 | Providing and Installing PVD coated SS transition profiles of thickness ranging from 0.8 mm to 1.5 mm on wall or floor with width upto 25mm as per design and approved drawings. U profile |
| 71 | Providing and Installing PVD coated SS transition profiles of thickness ranging from 0.8 mm to 1.5 mm on wall or floor with width upto 25mm as per design and approved drawings. Tile edging profile |
| 72 | Providing and Installing PVD coated SS transition profiles of thickness ranging from 0.8 mm to 1.5 mm on wall or floor with width upto 25mm as per design and approved drawings. Steps nosing prifile |
| 73 | Manual Twist Blinds - Providing & fixing of Twist Window Shadings Blinds as per the sample shown having room darkening fabric strip and sheer fabric strips alternately in such arrangement as when light filering strips overlap each other, it creates visibilty and once the light filtering strips overlaps the sheer ones, it creates the no visibility effect.It has bottom rail made of aluminium alloy extruded profile, powder coated and provided in fabric coordinated colour. The rolling tube should be made up of aluminium alloy from extruded profile of Ø34mm.The fabric of this Blind should be made up of 100% anti-static polyester vanes having light filtering and sheer vanes to reduce glare.Sheer layers made of white 100% knit polyester & the selection of colors, textures and opacities as per Engineer-in-charge.The FABRIC shall be constructed from spun-bonded 100% polyester fiber, having Green guard Certification treated with soil & dust repellant require minimum regular interval cleaning. The fabric has a maximum width of 2.80 M and a thickness of 0.38mm (+ 5%) and having weight of 272g/m2 (+ 5%).The strip size is Solid 8.5 cm /Sheer 6 cm. The shading to be operated by Easy rise mechanism with a continuous cord loop operating option.All plastic parts are in white color.Installation to be done by quick release brackets (wall or ceiling).( Basic rate of strip & sheer fabric is Rs.676 per sqft) |
| 74 | Manual Roller blinds - Providing and fixing Roller Blindsas per the approved sample comprising of Blackout fabric made up of 100% Polyester with Acrylic form backing (PVC free) of thickness 0.65mm ±5% and weighing 350 gsm with openness factor of 0% .The fabric is lead adn PVC free having OEKO_TEX standard 100 certification.The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyster cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diameter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps.The clutch will be atthe tube.The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on each side providing an aesthetic finish.It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. ( Basic rate offabric is Rs.258 per sqft) |
| 75 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below :1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 76 | Providing and applying of min. two or more coats of ISO 9001:2015 and Z.E.D certified,premium, high-performance Polyol + Isocyanate based Evg. PU coating system formulated crystalshield surface enhancer of approved make with wet film thickness (WFT) of 40 microns per coat and coverage 11 m²/liter/coat. It should be engineered for an exceptionally smooth, mirror-like finish with high scratch, chemical, and stain resistancesuperior chemical resistance, extreme durability, industrial-grade performance, UV resistance, anti-yellowing durability, self-Leveling FlowCoat, should dry in min. 60 minutes after application, min. 2000 SCR and industrial-grade protection, making it ideal for interior and exterior wood and metal. The paint should have min. 7 years of warranty and Hydro-Repel Technology in it for it to long last on interior as well as exterior surfaces. The base should be prepared by filling the gaps and cracks by filler putty followed by applying a clear Sp. Epoxy primer coating to fill the holes then the surface will be prepared to apply 2-3 coats of evg. pu enamel as per the manufacturer or OEM guidlines. The paint should have a min. of 7-years performance warranty on color retention, gloss stability, and film integrity. All components must be from the same manufacturer. An authorization letter from the OEM must be submitted before execution, as per the direction of the Engineer-in-Charge. |
| 77 | providing and fixing low height DGU glass partition of 24 mm thickness complete soundproof up to 30 Decibel Noise Cancellation, glass laying in UPVC section frame of 60mm width and 5mm thick with the required divided partitions with support from true ceiling with wooden or iron frame. The glass partition shall be provided on 3 doors for entranceaccess. The side facing to recreation room shall be covered though Gypsum wall of similar thickness to match the present aesthetics. |
| 78 | Damascus Perlatto/ Alba/Palmyra Or Equivalent- Internal Decorative Texture coatingsProviding and applying water-based special two-tone velvet/ Preimistic Pearl finish of interior grade having low VOC made up of special pearl pigments of make as approved by engineer in charge having special wipeable properties and finish to be equivalent to :-a. Damascus/Alba/Palmyra of UltraTech (UTTPL) OR EQUIVALENTb. Perlata of Armour Coat or Equivalentc. R-Stone fondo of Nova Color or EquivalentThe finish should have anti-algae and UV resistance properties in the desired pattern after scrapping and properlycleaning the surface to remove loose particles from the plastered surface. The following process to be followed : a.Initial coat of Masonry primer of approved colour and shade ( Min. 0.9 ltr /10 sqm). b. Two coats of base coat with roller and brush ( Min. 0.9 ltr /10 sqm). c. Final finish in 2 coats of Preimistic pearl finish (Wipeable grade) ( Min. 1.1 ltr/10 sqm).Cost of work shall be inclusive of all materials, labor etc. as per manufacturers specification and finish up to the entire satisfaction of the Engineer in Charge. |
| 79 | Providing and applying plaster of paris wall punning up to 12 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 80 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 81 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 82 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 83 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 84 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 85 | Providing and applying two or more coats of high quality Luxury interior grade acrylic emulsion paint of Asian Paints (Royale Luxury) / Dulux (Velvet touch) or equivalent make and shade as per manufacturer’s specifications to the interior surfaces of walls, beams, columns, canopies staircases, lobbies, Ceiling etc. with one coat of requisite primer and finishing smoothly, including scaffolding, etc. complete as directed by the Engineer. The surface shall be prepared properly and shall be levelled by the required POP putty etc. and finish the putty surface with papering after adequate drying at all levels and floors before applying the one coat of primer and two or more coats of interior emulsion paint . The cost include costs for disposing of the debris, curing, scaffolding, cost of all materials, labour charges etc. complete as directed. |
| 86 | Providing & applying Metallic duco paint of approved make, quality & shade as per the architects direction on wooden or metal surfaces. The rate shall include scrapping, levelling & preparing the surface, primer coat |
| 87 | Coriantop:-Providing&fixingcladdingwith\"Corian\" finish using Acrylic solid surface of 6 mm thickness on top of tables,faciastorageunits, columns etcetc.wheredirected.Therateto includeallmaterials,labour,transportation,wastagesetc.complete. |
| 88 | Providing and fixing suspended ceiling consist of Metal framework having ceiling drop of upto 1000mm, satisfying L/400 criterion at 200Pa. Ceiling comprises of Single layer, tapered edge 12.5mm Fireline Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions, consists of an aerated gypsum core with glass fibre and other additives encased in, and f irmly bonded to strong paper liners and conforming to IS 2095 Part 1:2023 Type F / EN520:2004-TYPE-F / ASTM C473/C1396-TYPE X, having thermal conductivity 0.24w/m°k having flexural strength – {Longitudinal > 550N & transverse > 210N}. Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade GI Sheet as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with AZ150 finish abiding to IS 15961 & tested for 500hrs of salt spray test as per ASTM B117 with a Global Warming Potential of 3.16 Kg CO2 per Kg from third party verified EPD as per ISO14025:2006, includes 28x20x30x0.5mm Perimeter Channel fixed along the periphery of existing wall/partition with the help of (6x40mm) Impact Sleeve Anchor for brickwall/blockwall, Ø8x45mmRawl Plug for RCC &Drywall Screw for Drywall, at 600mm centres. 25x10x0.5mm Ceiling Angle is suspended by fixing it to 37x27x25x1.6mmsoffit cleat {Material: CR1 steel (IS513),YS: 260Mpa ,Finish: Galvanised 120GSM (IS277)} and Ø8x45mm Rawl Plug at the true soffit, creating 1220x1220mm grid. 45x15x15x0.9mm Intermediate channel is fixed to the Ceiling Angle with M6x12mm Hex Nut & Bolt arrangement or with 2 Nos of Ø4.2x13 Metal to Metal screw. 80x53x26x0.5 Ceiling Section is then fixed to the Intermediate Channel with the help ofConnecting Clip {Material: EN 42J High carbon spring steel wire (BS 970), Finish: Zinc Plating (Minimum 5µ)} and in direction perpendicular to the Intermediate channel at 457mm c/c. Single layer of 12.5mm tapered edge Fireline is then screw fixed to ceiling section with ø3.5x25mmDrywall Screw with 17nos per m2 at 230mm centres on ceiling section & 150mm at periphery of ceiling. Edges & joints to be finished with Pro-Fill JC conforming to ASTM C475 & Paper tape. Note: •Control Joint to be provided at every 10m c/c along the length of ceiling. • Shadow line Bead to used at the junction of Ceiling and Brick/ Blockwall/ RCC. •Levelline Flex corner tape to be applied at all corners. • Certification can be issued if installation is done as per methodology & supervision. |
| 89 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval. including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square12.5 mm thick tapered edge gypsum moisture resistant board. |
| 90 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer\"s specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60. |
| 91 | Providing & Fixing of U Baffle made up of Aluminium panel Baffle panel ceilingof Wood colour (Burma Teak wood finish) consisting of panel size 50 mm wide and 125 mm deep using 0.7mm thick CC,with perforation and NWT,in 150 /100 module C/C, maximum length of panel is 5mt, and min is 2.4mt Coil / Powder Coated and roll formed from enamelled corrosion resistance Aluminium alloy for higher strength and good roll forming characteristics. The ceiling panels coil in the manufacturing process and releves stresses of coil. Baffle Panels should be manufactured from Roll forming machine only in India to get the high-quality Baffle panels with accurate dimensions. The baffle coils to go throughstages of treatment, and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability. The coils to be painted on both sides after degreasing. Inside surface to have a primer and a coat of natural colour onexposed surface to have a primer and topcoat of approved colour of 15 microns. Panels shall be clipped to a galvanized steel carrier of 0.5 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a CC gap of 70 / 120 mm . Panel carrier shall be suspended by means of threaded rod at a distance of 1.2 mtr. c/c. The Metal ceiling should have Green Pro cerificate All ceiling shall be Green pro Certified: For LEED certification by Indian Green Building council (IGBC). Ceiling manufacturer should have local manufacturing unit in India. Manufacturer should have Roll-forming machine to produce Baffle panels & in-house testing lab in India & having more than 20 years of existence in India. |
| 92 | Providing and installing of Acoustic bafflesis vertically installed unframed baffles. Baffle can be used to form distinct lines and is available in different sizes and a wide range of colors. Size 1200X1200X40mm, 1200X300X40mm, 1200X600X40mm, 1800X200X40mm, 1800X300X40mm, 1800X600X40mm to be ISO 14001 certified. Acoustics-Sound absorption (Alpha w) - 0.65 at 600 mm o.d.s at c600,Flexural tensile strength - Class C/Pass, Indoor Air quality - Complying with the French regulation on VOC emissions, A level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified, Comply with the REACH regulation of the European chemical Agency, certified by the EUCEB or equivalent which confirms that mineral wool is produced in conformity with the Note Q of EC No 1272/2008 or eqivalentand therefore classification as a carcinogen does not apply . ntal Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards, HPD certified Circularity - Minimum post-consumer recycled content 57%, Fully recyclableFire Safety-Tested and classified as non-combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 -1 -European Standard, Humidity Resistance- Class C, relative humidity 95% and 30°C, according to EN 13964:2014, Cleanability- Daily dusting and vacuum cleaning. Weekly wet wiping, Accessibility - The tiles are demountable, CE marking. This item is inclusive of all materials and services. ( Basic rate of Acoustic Baffle is Rs.990 per sqft) |
| 93 | metal flase ceiling -Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 94 | Cell Ceiling System Supply & Installation of Cell Ceiling of approved colour consisting Providing and installation of GI made and powder coated of approved RAL shade , cell ceiling with cell size of 75 x 75 mm. The cell is formed by locking of upper sections and lower sections with U shaped profiles of 40mm height15mm width and 595 mm length. The upper and lower sections when locked are locked with end panels on all 4 sides to form a tile of 595 x 595mm. Each tile is installed on a 15mm T Grids systemThe grids system is formed by lockingof GI made Main T of 3000mm or 3600mm length and GICross T of 600mm at 600mm c/c. GI wall angle 25x25 x0.4x3000mm {Material-GI(IS513),YS-280Mpa,Finish-Galvanised 90GSM(IS277)} is fixed along the periphery of the ceiling with wooden screws at 300mm centers or Hilti HPS 6x40mm placed at 600 mm c/c. The grid system is suspendedby 4 mm wire rod with adjustable clip, connected to the grids system at 1200mm c/c. The suspension rod with clip isfixed to the slab by means of soffit cleat and rawl plug ( fastner), at 1200mm c/c.soffit cleat 27x37x25x1.6mm {GI(IS513)YS-260Mpa,Finish-Galvanised 120GSM(IS277) } is fixed withRawl Plug- Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} Suspension. . All ceiling shall be Green pro Certified: ForLEED certification by Indian Green Building council (IGBC). Ceiling manufacturer should have local manufacturing unit in India. |
| 95 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 96 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 97 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x 28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening “for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 98 | Wooden ceiling finish with Laminate :Providing and fixing IS 71012 mm thickplywood false ceilingas per drawing & instruction of EIC & sample approved (complete with frame work). finish with 1.5 mm thick Laminate. Plywood shall be fixed with required fabrication work and ply framework with all necessary acessories Rate shall include cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever requiredThe rate shall be in sq.mt for all floors and at all heights including all costs the shop drawing (or a sample mock of 5 M2 minimum of the frame work and ceiling) shall be approved from EIC. 5mm Groove shall be provided at the junction of the false ceiling & the wall.(considering all levels with require all fabricataion work and fitiing from RCC slab to false ceiling100 to 1000 mm) |
| 99 | Artwork :Artwork to be prepared and designed by the artist as per the designs shared by architect and to have digital printing with brush strokes over it. Artwork frame to have wooden box frame finished in metallic shade duco or as per the approved design and shade shared in the presentation. The Artwork to be hung with hooks on all 4 sides as per the requirement. Note - The artwork will be as per approval of architect or Engineer Incharge. ( Base Rate of material is Rs 600 per sqft). |
| 100 | Providing and Installing plofiled back light 5mm thk. Float glass mirror of approved make and design with polished edge on wall over existing 12mm thk. Ply base with required framework adhesive/ silicon. (Design & size will be as per the required shape ) - Aluminim framed LED mirror |
| 101 | Feature Wall (GLASS MOSAIC TILE Work) - |
| 102 | Providing and fixing certified restroom cubicle system of approved make comprising of green guard certified solid compact laminated water proof board, minimum 18 mm thick made as per IS: 2046 (phenolic core board) and as per BS-476/97 for fire retardant for toilet showers, water closet etc . The board shall be manufactured under high pressure and temperature by impregnating kraft papers and outer decorative papers with thermosetting phenolic/ melamine resins (low VOC). The cubicle system shall be resistant towards water, chemical, scratch, impact and heat and shall be anti bacterial, colour fast and shall haveaccessories like door knob, Gravity/ auto return hinges, privacy thumb turn with occupancy indicator, coat Hook, etc all in SS 304. The hardware and fixings includes anchoring of all fixed front panel to floor with SS 316 L brackets/ base plates with a clearance height upto 110 mm, and covered with SS 316 Shoe box plates, wall and corner joineries (brackets and channels) shall be SS 304 grade, SS 304 screws, rubber noise reduction tape .The cubicle unit shall be installed in approved finish, shades and colours as per specifications and directions of Engineer-In-Charge,including minimum 5 (five) years warranty against any moisture related damages to all intermediate panels, doors, hardqwares etc. Standard dimension of the cubicle system shall be of approx. 2100 mm Height(overall) x 1500mm Depth and 1000 mm Width which includes 600mm door size width.I shaped Cubicle System consisting of front face panel including door and all necessary accessories, fittings and hardware etc. |
| 103 | Providing and fixing certified restroom cubicle system of approved make comprising of green guard certified solid compact laminated water proof board, minimum 18 mm thick made as per IS: 2046 (phenolic core board) and as per BS-476/97 for fire retardant for toilet showers, water closet etc . The board shall be manufactured under high pressure and temperature by impregnating kraft papers and outer decorative papers with thermosetting phenolic/ melamine resins (low VOC). The cubicle system shall be resistant towards water, chemical, scratch, impact and heat and shall be anti bacterial, colour fast and shall haveaccessories like door knob, Gravity/ auto return hinges, privacy thumb turn with occupancy indicator, coat Hook, etc all in SS 304. The hardware and fixings includes anchoring of all fixed front panel to floor with SS 316 L brackets/ base plates with a clearance height upto 110 mm, and covered with SS 316 Shoe box plates, wall and corner joineries (brackets and channels) shall be SS 304 grade, SS 304 screws, rubber noise reduction tape .The cubicle unit shall be installed in approved finish, shades and colours as per specifications and directions of Engineer-In-Charge,including minimum 5 (five) years warranty against any moisture related damages to all intermediate panels, doors, hardqwares etc. Standard dimension of the cubicle system shall be of approx. 2100 mm Height(overall) x 1500mm Depth and 1000 mm Width which includes 600mm door size width.L shaped Cubicle System consisting of front face panel including door, intermediate panel and all necessary accessories, fittings and hardware etc. |
| 104 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Slabs75 mm dia |
| 105 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Slabs100mm dia. |
| 106 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Slabs150mm dia |
| 107 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Slabs200mm dia |
| 108 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Beams65mm dia. |
| 109 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Beams160mm dia |
| 110 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Beams180mm dia |
| 111 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Walls65mm dia. |
| 112 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Walls160mm dia |
| 113 | Drilling with core cutting machine in Post RCC beams, slabs, floors etc. if not mentioned in the drawing but required by Project Manager for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Project Manager, including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. (Maximum thickness of RCC members shall be 300mm for slab & wall , 600 mm for beam). RCC Walls180mm dia |
| 114 | Automatic Sliding Door Sensor BasedDouble Door Automatic Sliding System with 4.15 Mtr Aluminium Track -1Nos, Brushless Motor 1 Nos, Control Unit 1 Nos,Return Pully 1 Nos, End Stoper 2 Nos Belt 7Mtr -1Nos,Floor Guide forGlass Door - 2 Nos, Programe Remote 1 Nos, Glass Clamp - 1050mm -2 Nos, Radar 2 nos Normal , Max 1050mmX2400mmtandard ApplicationSingle Panel Sliding Door ,Clear Passage Width :DoubleSliding = Min. 600 - Max. 2000 mm ,Clear Passage Height : 2700 mm (Recommended) Double Sliding = 2 x 80 Kg (Remote Control) Program Remote Modes : Off ,Automatic,Permanent Open, Exit Only Power Supply Data : 230 VAC, 50/60 Hz (Mandatory UPS / Stabilized Supply Opening Speed : 10 to 50 cm/sec(Incrementally Adjustable) ,Closing Speed : 10 to 40 cm/sec(Incrementally Adjustable),Hold Open Time : 0.5 to 30 sec(Incrementally Adjustable) ,Operator Mounting : Only Face. This Item is Including Dorma XLC 8106 or Equivalent L breakets for fix glass 16nos, XLC 4189 or EquivalentWave switch 2 nos., XLC 8028 or Equivalent Seal for moving Panels in 2 nos. |
| 115 | Supply & Installation of Saint-Gobain or Equivalent make Patch Fitting Door with SGF 2125 OR EQUIVALENTGlass Door Package - W/Lock SS, Glass door along with SGF 645 OR EQUIVALENT floor spring complaint with ANSI A156.4 including SGF 201 OR EQUIVALENT Bottom Patch, SGF 202 OR EQUIVALENT Top Patch, SGF 211 OR EQUIVALENT Corner lock and SGF 214 OR EQUIVALENT Top Pivot, with SGF D-Type / H- Type Pull Handle of size 300x22mm SS304 material with 10mm toughened glass, all Hardware material considered in same finish of fixed glass partition profile. Glass & Hardware should be of approved make. |
| 116 | Providing & fixing ofSS304 material 600mm OFFSET / D / H HANDLE approved make as per direction of Engineer in Charge |
| 117 | Providing & fixing ofSS304 material 1000mm to 1200mm OFFSET / D / H HANDLE approved make as per direction of Engineer in Charge |
| 118 | FLUSH DOOR SHUTTERProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm |
| 119 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick |
| 120 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100X58X1.90 mm |
| 121 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointedechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.Glazing and paneling to be paid for separately) :For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 122 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 123 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 124 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 125 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood50x12 mm |
| 126 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 127 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 60 mm |
| 128 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. |
| 129 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: (1) The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. (2) Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. (3) On drying of sealer coat, wet rubbing with emery cloth of finer grading with water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. (4) On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Finalo coat to be done in 1 or 2 layers without gap of time.) |
| 130 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 131 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 132 | Providing and fixing approved brand and manufacture of Stainless Steel Tower bolt 300 mm long with 10 mm dia along with necessary accessories and screws etc. complete in all respects as per manufacture specificatios & as directed by Engineer-in-charge. |
| 133 | Providing and approved brand and manufacture of Stainless Steel Door stopper of approved make- Door Mounted Hanging Type SS Satin Finish along with necessary accessories and screws etc. complete in all respects as per manufacture specificatios & as directed by Engineer-in-charge. |
| 134 | Providing and fixing approved brand and manufacture of Stainless Steel Door Buffer wall mounted 22 mm dia,75 mm long (DB (22) along with necessary accessories andscrews etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 135 | Providing and fixing Sliding bolt (baby latch) with SS lock strip 5\"\" (BL(B)) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 136 | Providing and fixing approved brand and manufacture of Surface Mounted with slide rail K (Symmetric) Mechanism Door Closer of approved make, Weight of door: 40-80 Kg, Width of door: 750-950 mm, Tested & Certified 500000 cycles, Silver Finish, Door closer power adjustment by change of position from hinge linealong with necessary accessories and screws etc. complete in all respects as per manufacture specificatios & as directed by Engineer-in-charge. |
| 137 | Providing and fixing approved brand and manufacture of SS 304 Solid die cast Mortice Lever handle of approved make with 8 mm spindle,With Restoring spring along with Steel base PVD coating: 16 micron with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 138 | Providing and fixing approved brand and manufacture of Mortice Sash lock Lock type : PZ - 72 W (W = handle/knob execution), Backset : 55mm, Face plate: Stainless steel, Face plate width: 24 mm / Hub: 8 mm, With closed lock case with 3 - fold fastening, Lock case: zinc - plated, Shiftable latch bolt. Latch bolt can be shifted without opening the lock case, with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-incharge. |
| 139 | Providing and fixing approved brand and manufacture of Euro Profile Cylinder of approved make with One side key and one side knob 60 mm, for max door thickness - 40 mm - SS Finish along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 140 | Providing and fixing Concealed Door Closer With Track Arm (SS Finish), Slide in SS Cover Stainless Steel door closer, door weight upto 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 141 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 142 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 143 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)6 way Double door |
| 144 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)8 way Double door |
| 145 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.Make:BS,Havells,Legrand (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 146 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 147 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 148 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 149 | Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.63 amps |
| 150 | Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.63 amps |
| 151 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing thepoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group – C |
| 152 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as requiredGroup – C |
| 153 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 154 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 155 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 156 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 157 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 158 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 x 10 sq.mm + 2 x 6sq.mm. earth wire |
| 159 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 160 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings). |
| 161 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 162 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 163 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing32 amps modular socket outlet and 32 amps modular switch, connection etc. as required. |
| 164 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 165 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 166 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 167 | Supplying and fixing of call bell / buzzer suitable for single phase,230 volt completeas required. |
| 168 | Supply of Integral, SMD 2x2 Backlit LED Panel, IP 20, 24W LED recessed mounted fixture with system efficacy of minimum 150lm/Wand system lumen output of minimum 3600lm, operating in ambient temperature of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have CRCA housing coated in white (RAL9016) with translucent HET diffuser for uniform illumination and wider light distribution. LEDs used in the product shall comply with IEC 62471. LM 80-08 compliant LEDs from approved makesshould be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type,Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with4KV internal surge protection, Power factor of minimum 0.95 and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. |
| 169 | Supply of SMD LED, IP 40, 18W Recessed downlighter with System efficacy of 120lm/W and system lumen output 2160 lumen, operating in an ambient temperatire of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have aluminium pressure die cast housing in white with high transmittivity diffuser for uniform illumination and reduced glare. EMC/PCT package of wattage of 0.5-1 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from approved makesshould be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 4000 K and CRI of Minimum 80, with MacAdam CCT binning <3 mounted on 1.6mm MCPCB/FR4 with 35 micron cu layer. LEDDriver shall be external, Isolated type,Constant Current topology driver with proper heat sink for heat dissipation suitable to operate at nominal rated voltage of240V with3 kV internal surge protection, Power factor of minimum 0.95, driver efficacy of minimum 85%, and total harmonic distortion (THD) of less than or equal to 5% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance toIndian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Luminaire Dimension : 159 mm dia, 39 mm height; cut-out dimension : 145 mm. |
| 170 | Supply of 12W recessed, deep inset COB LED Downlight luminaire having 1080 lumens with dimensions of 62mm dia and height of 74mm. The cut out dia (Φ) should not be more than 57mm. Luminaire shall be made up of pure polyster powder coated pressure die cast Aluminium housing with inbuilt heat sink to provide better thermal management to enhance LED life. The luminaire should be equiped with the secondary optics of high efficiency white coloured reflector. The luminaire should be available with multiple beam angle options of 38° and 60°.LM 80-08 compliant ceramic / aluminium base LEDs from approved makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Citizen should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. The luminaire should be IP20 rated. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 4000 K and CRI of Minimum 80. LED Driver shall be non-integrated type, Isolated, Constant Current operated driver with range 100-265V AC. Driver Efficiency > 85% & 2.5 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. |
| 171 | Supply of 20W, suspended by 1.5m suspension wire, 4 feet linear, IP20, SMD LED luminaire with system efficacy of 115 lumen/watt and system lumen output of 2300 lumen, operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, luminaire shall have extruded aluminium housing in white with high efficiency translucence diffuser and must have provision for end to end seamless connectivity. EMC package of wattage of 0.2-0.5 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from approved makesshould be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80, with MacAdam CCT binning ≤3 mounted on 1.6mm FR4 / MCPCB with 35 micron cu layer. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 3KV internal surge protection, Power factor of minimum 0.95, driver efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. |
| 172 | Supply of600mm dia Pendent Mounted LED. Fixture to be made of extrusion Aluminum housing in white finishwith HET plastic diffuser. LED Used shall be SMD type with Minimum system Lumens 3300 @30W & efficacy 110lm/W,Life of fixture : 50000 burning Hrs. @ L70 Lumen maintenance, CCT of 4000/5700K (SDCM<=3), CRI Ra >=80, PF >0.95, operating Voltage Range of 150-270 V AC. Minimum Internal Surge Protection 2.0KV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Luminaire should have RoHS, EMI EMC as per IEC 61547, CISPR 15. |
| 173 | SITC Fresh For 230mm exhaust fan, typical specifications include a 230V, 50Hz power supply, single-phase motor, copper winding, metal body, and performance conforming to Indian Standards like IS:2312, with features like double ball bearings, Class E insulation, and varying air delivery (around 1000-2000 m³/h) and speeds (1350-1500 RPM), often with a louver shutter and available in capacitor or non-capacitor types |
| 174 | SITC of wall fan Common specs include 400mm sweep, 230V AC, 1300-1500 RPM, 70-100W power |
| 175 | Metal Raceways : FloorsSupply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:300 x 20 mm Raceway |
| 176 | 250 x 20 mm Raceway |
| 177 | 200 x 20 mm Raceway |
| 178 | 150 x 20 mm Raceway |
| 179 | 100 x 20 mm Raceway |
| 180 | 75 x 20 mm Raceway |
| 181 | Metal Junction Box : FloorsSupply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:Sizes:Box : 400 x 400 x 45-60mm [1mm base & 3mm lid]Cover Plate : 400 x 400mm |
| 182 | Box : 300 x 300 x 45-60mm [1mm base & 3mm lid]Cover Plate : 300 x 300mm |
| 183 | Box : 225 x 225 x 45-60mm [1mm base & 3mm lid]Cover Plate : 225 x 225mm |
| 184 | Box : 150 x 150 x 45-60mm [1mm base & 3mm lid]Cover Plate : 150 x 150mm |
| 185 | Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness |
| 186 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 187 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 188 | Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness |
| 189 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 190 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 191 | Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness |
| 192 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 193 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 194 | Supplying and installing following size of perforated pre-painted M.S cable trays Tee\"s with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness |
| 195 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 196 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 197 | Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness |
| 198 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 199 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 200 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)\"s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc30KVA (Each Power module shall be < 10 KVA) |
| 201 | Supplying and fixing of following Vertical three-phase distribution board with provision for 4 pole MCCB up to 160A as incomer with three-phase and single-phase (TP/SP) MCB outgoing. These distribution boards come with complete insulated busbar tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars. Top and bottom removable gland plates with knockouts. Mounting of these boards can be flush or surface. (But without MCBs and incomer) as required.INCOMER8 no 63 A TP MCB 8 Way VTPN DB descrived above |
| 202 | Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/ ScrollCompressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmationas per I S 18728: 2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping.The system shall be able to deliver 100% ofthe rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity >40 and <70 ISEER 7.5, Capacity> 70ISEER 7.6 for Super ECSBC Building) For Cooling & HeatingBoth6 HP to 8 HP |
| 203 | 10 HP to 12 HP |
| 204 | 14 HP to 22 HP |
| 205 | Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibrationIsolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals.The system shall be capable to adjust air flow as per room requirement in auto mode.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)0.8 TR 4- Way Cassette Type Units |
| 206 | 1.0 TR 4- Way Cassette Type Units |
| 207 | 1.2 TR 4- Way Cassette Type Units |
| 208 | 1.6 TR 4- Way Cassette Type Units |
| 209 | 2.0 TR 4- Way Cassette Type Units |
| 210 | 2.6 TR 4- Way Cassette Type Units |
| 211 | 3.6 TR 4- Way Cassette Type Units |
| 212 | 4.1 TR 4- Way Cassette Type Units |
| 213 | 4.6 TR 4- Way Cassette Type Units |
| 214 | Supply, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamicall balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals.The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)1.6 TR Highwall Units |
| 215 | 2.0 TR Highwall Units |
| 216 | Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required.The unit shall have automatic forceshut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.3.2 TRDuctable Unit |
| 217 | 4.0 TRDuctable Unit |
| 218 | Supply, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibrationIsolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)5.5 TRDuctable Unit |
| 219 | 8.0 TRDuctable Unit |
| 220 | Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM)make as of ODUs and IDUsIndoor Units |
| 221 | Outdoor Multi Joint |
| 222 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 223 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 224 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 225 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 226 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 227 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 228 | 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 229 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 230 | 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 231 | 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 232 | 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 233 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 234 | Supply, installation, balancing and commissioning offabricated at siteGSS 120 GSMsheet metal rectangular/round ducting .Complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet (24 Gauge) |
| 235 | Thickness 0.80 mm sheet (22 Gauge) |
| 236 | Thickness 1.00 mm sheet (20 Gauge) |
| 237 | Thickness 1.25 mm sheet (18 Gauge) |
| 238 | Note- Cost shall include hanging and support of GSS ducts and AHUs shall be with Gripple/Hilti Hangers & Supports complete with end fixing in accordancewith the approved shop drawings and as required by the specifications. Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. Make: Airflow(mapro),Ruskin titus,Systemair. |
| 239 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. Make: Airflow(mapro),Ruskin titus,Systemair. |
| 240 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. Make: Airflow(mapro), Ruskin titus, Systemair. |
| 241 | Supplying, fixing testing commissioning of supply air diffusers round/square flat plate type smuge proof of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. Make: Airflow(mapro), Ruskin titus, Systemair. |
| 242 | Supplying, fixing testing commissioning of Return air diffusers round/square flat plate type smuge proofof powder coated aluminium without volume control dampers with anti smudge ring & removable core.Make: Airflow(mapro), Ruskin titus, Systemair. |
| 243 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications..Make: Airflow(mapro), Ruskin titus, Systemair.Fire damper |
| 244 | Actuator |
| 245 | Supply, installation, testing & commissioning of Central Controller capable of controlling of all IDUs, ODUscomplete with necessary hardware, accessories etc. to perform the following functions:Controlof IDUs, ODUs Units as above with monitoringof vital parameterssuch as temperature sensing & setting, ON/OFF, status etc.Permit / prohibit function of each remote controlled unitOperation of units in individually or in groupFault indication with AlarmProvide interface to connect complete VRF system with third party BMS systemThe central controller will be complete including all hardware & software suitable to perform above function.Complete in all respect as required at site. |
| 246 | Providing & fixing control cum transmission wiring of 2 core x 1.5Sq.mm copper in cable tray with refrigerant piping between indoor units and outdoor units and indoor units and wiredcontrollers.Make:As per selected VRV OEM Complete in all respect as required at site. |
| 247 | AIR HANDLING UNITS SUITABLE FOR VRV/VRF SYSTEM BMS CompatibleSupply,Installation,Testingandcommissioning offactorybuilt floor mounted/ceiling suspended DX Typedoubleskintypehorizontal/vertical air handlingunitsmadeof 25mmthickpanelsconsistingof pre plasticizedG.I.casingofthickness0.8mmoutsidelayerand0.8 mm inside layer with polyurethanefoam (PUF) insulationfactory injected between them by injectionmouldingEquipments, complete with Plug fanswithblowersuitableforstaticpressureas required, minimum 2bend GSS/PVC eliminators,cooling coil section with aluminiumfinned copper tubes (tubes thicknessnot lessthan0.5mm)coolingcoilof 4/6 rowdeep,filtersectionwith 50mm thick metal viscous/ washablesynthetic type air prefilters, belt drivepackagewithTEFCdrivemotorofefficiencyclassIE3 suitablefor 415 ± 10% volts,50Hz,3 PhaseAC supplywithsuitable variablefrequencydrivecontrol panel, drain connections. 1) Plug Fans (with min. 70% efficiency) with motor (VFD compatible) ,volume control damper and duct flexible connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply & high efficiency (IE-3 Efficiency), H.P of motor shall be as per actual selection meeting other technical requirements.2) 6 Row Deep Cooling Coil with Alu. fins-Coated3) SITC UVGI Emitter system along with power / control wiring. Access doors should be fitted with interlocks which will turn off the UV in the event the door is opened. Precaution labels should be posted near access doors to any equipment with UV systems.4)AHU with CBR filter5) COIL- 4/6 row Copper tubes and Aluminum fins 12 fin./inch, Coil size shall be selected for air velocity of 350 ft./minute & velocity across filters at350 ft./minute.6) Equipments shall be BMS compatible for control and monitoring,cost shall be inclusive of all BMS component (like controller,cabeling etc.) to make system complete as required by engineer in-charge.In Built VFD & Screen Controller :- VFD designed for HVACapplications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure for use on standard centrifugal plug fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters. EACH VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption.EACH VFD shall be installed in a dedicated external IP-65 enclosure and theinter connecting wires between driver and MCC shall be included. Item tabulated separately.2200CFM AHU WITH 60 MMWG SP |
| 248 | 1000CFM AHU WITH 60 MMWG SP |
| 249 | Thermostat for AHU (Proportional type ) BMS CompatibleSupply, installation,testingandcommissioningof latest generation digital display type BMS compatible thermostat / humidistat with controller for cool / heat application suitable for two/four pipe system & humidistat suitable for working with humidifier and hot water coil control valves for various air handling Units. The thermostat shall have provision of setting of space temperature and display of the same. The humidistat shall have provision of setting space RH and display of the same. The quoted price of thermostat / humidistat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. The cost quoted shall be excluding the control valves and humidifier.It shall include all accessories ,mountings, wiring between thermostat & unit, terminations etc.(BMS Compatibility to be provided).Thermostat for air-handler. |
| 250 | Supply, installation, testing and commissioning of duct mounted Air Purification System with AOP comprising of UVC lamp 254 NMwith nanoX coating metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube,with the capability to produce ionized Hydroxyl oxidizers with in-built plasmoX to generate ion generator pins (+- ions 10^6) along with ultrasonic radio frequency waves for pest repellancy. The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only Germicidal UV (by definition this means 99.99% UV-C energy). The airpurifier will have built in LED indication system stating the operation of the 3 technologies the UV lamp, ionizer and pest repellant. The AOP Cell should be with inbuilt digital run hour meter along with RS485 port. The wattage of the lamp shall not be less than 21 watts upto and length not less than 436 MM upto 6500 CFM and a minimum of 48 watts upto 28000 CFM or combination based on the application area. The system shall be capable of reducing microbial contamination(bacteria, virus and spores), VoC’, odors and particulates matter. The equipment shall have to CE, TUV, GreenPro,ISO 13485, ROHS with 2014/35/EU Low Voltage Directive along with FDA compliance certifications. ormers, control cabling and Plug Top & necessary power cable. Vendor to comply all Tender Specifications.The AOP cellshall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication AOP does not produces ozone, the test certificate from an International Lab shall be produced. The specific certifications shall be submitted along with the technical submital. The failure to submit the certifications along with the submital shall lead to rejection of the product. The AOP cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed.2200 CFM |
| 251 | 1000 CFM |
| 252 | Air Purification System For Air Handling Units BMS CompatibleSupply, installation, testing and commissioning of air purification system for Spilt/Cassette AC\"s with Advanced Oxidation Plasma cells comprising of UVC lamp 254nm having nanoX metallic compound target Alumninum matrix cell duly enclosed by a poly casing tube, with the capability to produce Hydroxyl oxidizers. The unit shall have inbuilt multipin plasmOX generator having 6 pins with minimum anion denisty 10*10*6 per cm². The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only germicidal UV (no board spectrum lamp). The power / control cabling of the unit shall be interlinked with Cassette unit or Split unit. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to GreenPro,TUV,CE, ISO 13485, RoHS with 2014/35/EU Low voltage directive along with FDA compliance certifications. The systemshall have a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication unit does not produces ozone, the test certificateshall be produced.The unit shall be selected depending upon the sizes of the Cassette Unit or Split Unit and should be placed between fan & filter there itself with proper hooking arrangement for each specific area where the equipment is to be installed. The units Should be complete with control cabling and plug top & necessary power cable. The specific certifications shall be submitted along with the technical submital. The failure to submit the certifications along with the submital shall lead to rejection of the product. The units shall be 100 percent manufcaturered in India. Vendor to comply all Tender Specifications.Cassette Unit |
| 253 | VRV kit for AHU Supply, installation,testingandcommissioningof VRV kit for AHU to make it compatable with VRV system. |
| 254 | HVAC Panel 1 for VRV AT TERRACE Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 54 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.Complete as required as per site conditions.15% Vacant / spare feeder needed. At bottom 75mm MS Channel needed. EACH Motor control Centre(MCC)/Panel shall include cost of cabling, wiring, control wiring & inter locking in order to execute the required sequence of operation.A separate Each of CTs to be provided forwiring from CT’s and voltage transducers to be brought on to separate Each of terminals.Note :MCCB’s shall be motor duty and suitable for 25 KA (ICS) fault currentMotor Control Centre(415 V) consisting of Incoming. 1 No. 500 amps 4 Pole ACB ICU=ICS=25KAhaving front operating handle with door interlock and as per preamble above complete with the following :0 - 500 volts 96 x 96 sq mm digital voltMETER with selector switch - 1 Each0 - 500 amps 96 x 96 sq mm digital amMETER with 500/10 amps CT’s and selector switch - 1 EachOver voltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes - 1 EachPhase indicating lamps, with toggle switches withFuse/ MCB for protection.Terminals to receive XLPE insulated Aluminium cables.Busbar. TPN bus bars shall be of aluminium and shall be sleeved. Phase bus bars shall be rated at600 amps and neutral bus bar shall be of 50% capacity suitable to withstand symmetrical fault level of 25KA of 415 V. Maximum density of aluminium bus bars for current carrying capacity shall be one amp per square mm. Outgoing14 EACH 63 amps MCCB outgoing feeders toVRV outdoor unit .EACH of these compartment shall contain CT operated digital ammeter of 0-60 amps range with selector switch, and an indicating lamp with MCB and toggle switch for ‘ON’ status.(3 spare but without metering )Supplying,Receiving, fixing, testing & commissioning of HVAC Panel for VRV-1 as described above.Complete as required as per site conditions. |
| 255 | HVAC Panel 2 for VRV AT TERRACE Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 54 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.Complete as required as per site conditions.15% Vacant / spare feeder needed. At bottom 75mm MS Channel needed.EACH Motor control Centre(MCC)/Panel shall include cost of cabling, wiring, control wiring & inter locking in order to execute the required sequence of operation.A separate Each of CTs to be provided forwiring from CT’s and voltage transducers to be brought on to separate Each of terminals. Note :MCCB’s shall be motor duty and suitable for 25 KA (ICS) fault current Motor Control Centre(415 V) consisting of Incoming1 No. 450 amps 4 Pole0 - 450 amps 96 x 96 sq mm digital am METER with 450/10 amps CT’s and selector switch - 1 Each ACB ICU=ICS=25KAhaving front operating handle with door interlock and as per preamble above complete with the following :0 - 450 volts 96 x 96 sq mm digital voltMETER with selector switch - 1 Each Over voltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes - 1 Each, Phase indicating lamps, with toggle switches., Terminals to receive XLPE insulated Aluminium cables, Busbar,TPN bus bars shall be of aluminium and shall be sleeved. Phase bus bars shall be rated at600amps and neutral bus bar shall be of 50% capacity suitable to withstand symmetrical fault level of 25KA of 415 V. Maximum density of aluminium bus bars for current carrying capacity shall be one amp per square mm. Outgoing11 EACH 63 amps MCCB outgoing feeders to VRV outdoor unit .EACH of these compartment shall contain CT operated digital ammeter of 0-60 amps range with selector switch, and an indicating lamp with MCB and toggle switch for ‘ON’ status.(2 spare but without metering )Supplying,Receiving, fixing, testing & commissioning of HVAC Panel for VRV-1 as described above.Complete as required as per site conditions. |
| 256 | Isolator Switches With Metal Enclosure(suitable for outdoor application)63A RCCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.).Complete as required as per site conditions. |
| 257 | 40A RCCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.).Complete as required as per site conditions. |
| 258 | 32A RCCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.).Complete as required as per site conditions. |
| 259 | 25A RCCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.).Complete as required as per site conditions. |
| 260 | Cables form Air Conditioning Panel to EACH of ODUs Supply, laying & fixing of following sizes of PVC sheathed PVC/XLPE insulated copper conductor power/ multicore control unarmoured cable of 1.1 KV grade with brass compression gland and copper lugs.Complete as required as per site conditions.4 C x 6 Sq.mm |
| 261 | Cables form Air Conditioning Panel to EACH of ODUs 4 C x 10 Sq.mm |
| 262 | Cables form Air Conditioning Panel to EACH of ODUs 4 C x 16 Sq.mm |
| 263 | MV CableSupply, laying & fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.Complete as required as per site conditions.4C- 6 sq mm Aluminium |
| 264 | 4C- 4 sq mm Copper |
| 265 | Note: All cable shall be lay over cable trays as mentioned below.Supplying and erecting approved make GRP / FRP Ladder type Cable TrayMaterial – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % -Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 .Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per StandardASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65(A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 266 | (B) Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 267 | (C) Width 450 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 75Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 268 | (D) Width 600 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 90Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 269 | (E) Width 750 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 120Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 270 | Stainless Steel 304 sheets, to SMACNA and ASHRAE norms c/w all bends, tees, branch- outs, splitters, spigots,(Material meeting BS 476 Part 6 and part 7 norms) Thickness 1.25 mm sheet |
| 271 | Supply and Installation of GI backdraftdampersas per UL 555 Standard, |
| 272 | Supply, installation and testing of Canvas connection for the AHU units to the duct. |
| 273 | Note-1.All hanging and support of ducts shall be with threaded rod Hangers & Supports complete with end fixing in accordancewith the approved shop drawings and as required by the specifications.2.All the plenums shall be constructed with 18G sheet** Duct shall have fire rated coating compound STARCOAT – CRC / FLAMEBAR.Fire rated coating compound used for construction of fire rated ductwork shall be protected with minimum 0.7mm to 1mm nominal thickness tested to properties as per the requirements of BS 476: 6 & amp; 7, including non-combustibility Class O and fire propagation - Class 1 surface spread of flame & materials in accordance with building regulations.Supply, installation, testing & balancing of Extruded Aluminium in aerofoil construction opposed multi blade volume control dampers complete with bush, gears, linkages, shaft & operating handles within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air.Dampers shall be supplied in accordance with the specifications and approved shop drawings. |
| 274 | Supply & Installation of Under deck InsulationPreinsulated PIR Panels with one side Embossed Aluminium foil and other side Kraft Paper close cell rigid polyisocyanurate foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7 (CBRI India approved), with Density of 48kg/m3 as per ASTM D 1622 : 03and should have Thermal Conductivity 0.021 W/mK as per ASTM C518 : 2010 , Water absorption shall be not more than 0.03% as per ASTM C 209:1998. 30MM THICKNESS |
| 275 | Supply, installatio, testing, balancing and commissioning of extruded aluminium powder coated door transfer grill mesh for toilets,with matching flange at rear side as required.600 mmX 150 mm Size |
| 276 | LouversSupplying, installing, testing and commissioning of Fresh Air powder coated Anodized extruded aluminium construction fresh air louvers (50 mm deep) (Fresh air louver with VCD , bird screen & rattle-free) complete as per specification. |
| 277 | Supplying, installing, testing and commissioning of Exhaust Air powder coated Anodized extruded aluminium construction fresh air louvers (50 mm deep)air louver without VCD , bird screen & rattle-free)complete as per specification. |
| 278 | Supply & installation ofexternal thermal insulation on ducts with 7 mil black colour factory laminated fibre glass cloth( Glass Cloth is 205 +/- 10 grams per square meter, Tensile Strength is 275 +/- 25 Kg / 50 mm (minimum) and Thickness is 0.18 mm / 7 mil.)on closed cell nitrile rubber with density 40-60 Kg/ Cum for nitrile rubber, class \"O\" complete as per specifications. All longitudnal and transverse joints shall be sealed with 50mm wide and 3mm thick Nitrile rubber tape. The cost shall be inclusive of Low VOC adhesive.19 mm thick (Supply air ducts in Conditioned Space) with protective coating |
| 279 | 25 mm thick (Supply air ducts in Outdoor) with protective coating |
| 280 | Supply & installation, testing and commissioning of Rigidheavy class PVC piping complete withfittings, supportsas perspecifications anddulyinsulatedwith6 mmthick nitrile rubber tubular insulation with factory laminated GC cloth.Complete as required as per site conditions.25 mm dia with 6 mm thick tubler XLPE insulation |
| 281 | 32 mm dia with 6 mm thick tubler XLPE insulation |
| 282 | 40 mm dia with 6 mm thick tubler XLPE insulation |
| 283 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing and fixing white vitreous china cistern with dual flushing fitting,of flushing capacity 3 litre/6 litre( adjustable to 4 litre/8 litres),including seat cover and cistern fittings,nuts,bolts and gasket etc. complete. |
| 284 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 285 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 286 | Providing & Fixing of C.P WALL MOUNTED SWIVEL SPOUT KITCHEN SINK MIXER with all accessories as per approved specifications, Material: Brass,Size(mm):180(L) x 185(W) x 225(D),Spout Length(mm):135,Mounted : Wall mounted,Series : Rivera , Origin Made In India |
| 287 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 288 | Providing and fixing CP Brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge. |
| 289 | Providing and fixing toilet paper holder C.P. brass |
| 290 | Supply & Installation of Twin Coat Hook:Material:18-8 S, type-304, stainless steel,Application:WC Cubicle Area,Warranty:1 year , Origin Made In India |
| 291 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15mm nominal bore |
| 292 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length |
| 293 | Providing & fixing of C.P Towel ring, cost inclusive of CP flange, fasteners, complete as per manufacturer recommendation as per approved specifications , Origin Made In India. |
| 294 | Supply & Installation of S.STEEL SOAP DISPENSER (HEAVY TRAFFFIC) Container : 18-8 S, Type-304, Stainless SteelMaterial : Non Corrosive Steel, Capacity : 400 ML, Dispense Volume : 2 ML, Origin Made In India |
| 295 | Supply and fixing of water cooler fully stainless steel of 60 litres cooling capacity and 120 litres storage capacity to be operated on single phase supply with ISI mark.Each Cooler shall be provide with 4 Nos pessmatic tap for Drinking purpose. |
| 296 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 297 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia |
| 298 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 299 | Supply & Installation of Auto Closing System Bib Cock, Range:Pressmatic Tap,Flow Rate (Litre Per Minute),0.5 Bar:7.21,1.0 Bar:9.91,2.0 Bar:13.93,3.0 Bar:17.00 , Origin Made In India |
| 300 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc15mm nominal bore |
| 301 | 20mm nominal bore |
| 302 | 25mm nominal bore |
| 303 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore |
| 304 | 25 mm nominal bore |
| 305 | Providing and fixing soil, waste and vent pipesSupplying, Installation, Testing and Commissioning of uPVCpipes type -B conforming to IS 13592 (1992) for soil, waste and vent pipes including all fittings rubber ring type (plain or with access door) e.g. bends, junctions, cowls, offsets, access pieces,jointing with rubber ring joints with lubricant etc. fixed with clamps to walls with cement concrete 1:2:4 blocks complete in all respects. (For Soil & Waste Pipe)110 OD mm |
| 306 | Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 6Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For Soil & Waste Pipe)40 OD mm |
| 307 | 50 OD mm |
| 308 | 65 OD mm |
| 309 | Supplying, Installation, Testing and Commissioning of uPVC, P or S trap of self cleansing design with / without vent. arm Setting in cementconcrete 1:2:4 mix complete including cost of cutting & making good the Wall / Floors wherever required. 110 x110 mm outlet |
| 310 | Providing and fixingfloordrain with jali size 110X50 size inlet and outlet including cutting and making good the walls and floorswherever required complete in all respects.110 x 50 mm outlet |
| 311 | Providing andfixing 125 mm dia,3 mm thick Stainless steel grating with framefor floor traps or drains of required pattern including cutting and making good the floors complete.125mm dia. |
| 312 | Providing and fixing cast brass Cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect. 100mm dia. |
| 313 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia |
| 314 | 32 mm dia |
| 315 | 40 mm dia |
| 316 | 50 mm dia |
| 317 | 65 mm dia |
| 318 | 80 mm dia |
| 319 | 100 mm dia |
| 320 | 150 mm dia |
| 321 | Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .65 mm dia |
| 322 | 80 mm dia |
| 323 | 100 mm dia |
| 324 | 150 mm dia |
| 325 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 326 | Upright Sprinkler |
| 327 | Providing and fixing of pressure switches in MS pipe line including connection extra as required. |
| 328 | Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.1500mm |
| 329 | Supplying, installation, testing and commissioning of Dial typepressure gauge conforming to IS 3624:1987 with 150 mm diameter Gylcerine filled dial casing isolated through a forged brass ball valve from the piping including short piece, nipples, elbows etc as required to complete the installation. The pressure guage shall be suitable for rating between 0 to 20 bar with no Syphon. |
| 330 | Supply, installation, testing and commissioning of ISI marked handheld CO2 based fire extinguisher (CE and PESO certified) with minimum sheet thickness of 1.6mm, epoxy powder coating on the inner side and epoxy polyster powder coating on the outside, tested via helium leak detection test conforming to IS: 15683 with gun metal cap and nozzle complete in allrespects including initial fill and wall suspension brackets. (4.5 KG) |
| 331 | Supply, installation, testing and commissioning of ISI marked handheld dry chemical powder type ABC (Mono ammonium phosphate and ammonium sulphate) fire extinguisher with minimum sheet thickness of 1.6mm, epoxy powder coating on the inner side and epoxy polyster powder coating on the outside, tested via helium leak detection test conforming to IS: 15683 with gun metal cap and nozzle complete in allrespects including initial fill and wall suspension brackets.(6KG) |
| 332 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer. |
| 333 | Supply, installation, testing and commissioning of ISI marked handheld Foam based fire extinguisher with minimum sheet thickness of 1.6mm, epoxy powder coating on the inner side and epoxy polyster powder coating on the outside, tested via helium leak detection test, pressure indicating gauge, internal tube, squeeze lever type valve fully charged, conforming to IS: 15683 with gun metal cap and nozzle complete in allrespects including initial fill and wall suspension brackets.(9KG) |
| 334 | Fire Alarm Panel, Supply Installation Testing and Commissioning of Micro processor based 2 wire fault tolerant loop, with inbuilt network port(each loop accessing198 detectors, Devices & modules ) fire alarm/detection control panel. The panel shall be able to givelocation ofall fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control modulewhen ever any alarm is triggered. Addresses of each FDA sensor, hooter, manual call point etc., shall be legibly marked near respective sensors. It Should have provision for triggering/integrating the Gas Suppression System, PAVA System & Fire Fighters Telephone System. • Up to 2000 soft zones, 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops• Control-by-event (CBE) equations for activations with logical operators• Historical log stores 10,000 events, plus 4,000 active events in non-volatile memory (standalone or network configuration)• Clock in real time• Auto-programming lines with automatic recognition of the model of the devices• Decision algorithms for the alarm, pre-alarm and faults• Automatic day / night sensitivity change• Indication of the need to clean the smoke sensors• Programmable alarm threshold for all sensors• Walk-Test function by zone• 7 Inch Touch Screen (800 x 480 mm with backlight), 256-colour touch-screen to indicate Fire/Fault Signal with address.• The Panel Shall have provision for 40Zones display on screen with Individual Zone Indicators expdable upto 200 Zones. • Relay Output: 1 fault (NO/NC); 1 alarm and 2 optional (NO/NC or monitored 1 A, balanced with resistor / diode). • Souder Output: 1 (monitored 1 A, balanced with resistor or diode)• The panel shall have a built in power supply 100 ... 240 V AC, 50 / 60 Hz, max. 2,4A @ 230 V AC. Battery charger along withmaintenance free batteries of 2x 12V / max. 38Ah upto 72 hours of battery backup.• The supply & installation of the entire FDA system shall conform to IS 2189 / BS 5839 / NFPA 71 & 72 / TAC norms. All equipment and systems shall be tested and approved by LPCB/UL/FM/relevant IS/EN Standard.Apporved Makes : Bosch FPA 4000 Series / Firefinder by Siemens, Edwards EST3, Honeywell Morley Max Series. 4 Loop Panels |
| 335 | Supplying, installing, testing and commissioning of Modbus / LonWorks / BACnet Card for BMS Integration ( If required) |
| 336 | Supplying, installing, testing and commissioning approved make Graphics User Interface for Monitoring & Control of complete Fire, Voice Evacuation & Telephone Talkback System. The GUI based main network software shall network with other panels on network. It shall be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems, and / or sensors’ locations. It shall have the facility to change the sensitivity of any detector. The software shall be capable of monitoring 200 Nodes with 100 Mbps Transmission rate on Fibre Optics Network and 12 Mbps Transmission on cable and 2,50,000 network points. The Graphic workstation shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of GUI.Apporved Makes : Bosch FPA 4000 Series / Firefinder by Siemens, Edwards EST3, Honeywell Morley Max Series |
| 337 | Supplying, installing, testing and commissioning of Intel i7PCwith 2.2 GHz Processor & 16 GB RAM, NVIDIA Graphics Card and 32\" Display, Keyboard & Mouse for Graphics Software |
| 338 | Repeater Panel (For Guard Room/Reception), Supply, Installation, Testing & Commissioning of Active Network Repeater Panel with minimum 7\" 256 Color Touch Screen display having controls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards, mapping minimum 20,000 points on network. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. NRP can act as Remote Zone Annunciation panel and should work on 30 VDC & 1A as required to complete the installation and complete as per specification/drawings and as directed by Engineer In Charge and duly approved by LPCB/UL/FM/relevant IS/EN Standard. Makes: BOSCH FMR-1000-RCMD, Cerberus by Siemens ,Morley MA-LCD7 , Edwards 3-LCD ANN)Apporved Makes : Bosch FPA 4000 Series / Firefinder by Siemens, Edwards EST3, Honeywell Morley Max Series. |
| 339 | Multi-Sensor Detector (For Common Area) SITC of Intelligent Analog Addressable Type Photo-Thermal Detector with Dual LED and inbuilt isolator, Hard Addressable Having rotary decade Address swicthes, complete with Mounting Base. The detector shall share the analog datapoints to the panel.The detector shall have 6 levels of smoke sensitivity. The detector shall operate in both ROR (10 ºC) and Fixed heat (58 ºC) basis requirement. Operating Voltage shall be 15 to 28 Vdc. The Detector shall meet RoHS standard & shall confirm to BS 5839 Standards and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley HM-PTSE-AP+B501, Edwards SIGA PHD+SIGA-SBApporved Makes : Bosch FPA 4000 Series / Firefinder by Siemens, Edwards EST3, Honeywell Morley Max Series. Above False Ceiling |
| 340 | Smoke Detector (For Common Area)SITC of Intelligent Analog Addressable Type Photoelectric Detector with Dual LED and inbuilt isolator, Hard Addressable Having rotary decade Address swicthes, complete with Mounting Base. The detector shall share the analog datapoints to the panel.The detector shall have 6 levels of smoke sensitivity. Operating Voltage shall be 15 to 28 Vdc. The Detector shall meet RoHS standard & shall confirm to BS 5839 Standards and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OP921+DB-11, Honeywell Morley HM-PSE-AP+B501, Edwards SIGA PHS+SIGA-SBBelow False Ceiling |
| 341 | Rate of Rise Heat Detector (for Pantry Area, Toilets, Parking Basement, etc)SITC of Intelligent Analog Addressable Type Rate of Rise Heat Detector Complete with Dual LED andinbuilt isolator, Hard Addressable Having rotary decade Address swicthes, complete with Mounting Base. Operating Voltage shall be 15 to 28 Vdc. The Detector shall meet RoHS standard & shall confirm to BS 5839 Standards and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. (Detectors without inbuilt isoaltors may be considered with an additional isolator module after 20 devices). (Make: Bosch FAH-440+FAA-440, Siemense Cerberus HI921+DB-11, Honeywell Morley HM-RHSE+B501, Edwards SIGA DHI+SIGA-SB |
| 342 | Supplying, installing, testing and commissioning approved make Response indicator for all detectors located above false ceiling. |
| 343 | Manual Call Point (For All Exits & Corridors/areas longer than 30 Mtr from Nearest Exit)SITC of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting option fully compliat EN54 having Rotary Decade Swicthes. Operating voltage 15 to 32 Vdc and shall complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved byLPCB/UL/FM/relevant IS/EN Standard. Makes : (Makes: Bosch FMM-325A-D,Siemens Cerberus HMS-S, Morley MI-MCP, Edwards SIGA 278) |
| 344 | Sounder Cum Strobe (for All Exits, Dead Ends/Blind Corridors, or as per site requirement)SITC of approved make Addressable Loop Powered Sounders cum Strobes with inbuilt isolators or Sounder Strobe with Control Module and Power Supply with all accessories. Addressing shall be with user friendly rotary decimal switches. Device shall have 32 different tones @ 90 dB & 1 Hz Flasher, High output LED technology and superior lens design optimize light outputs. The device shall be compatible with the detector base and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. Makes Make Bosch /Siemens Cerberus / Morley / Edwards |
| 345 | SITC of Intelligent Analog Addressable Relay Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicatorwith Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes, for initiating Hooter/Sounder/Strobes. Operating voltage 15 to 30 Vdc shall be conforming to BS5839 Standards and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. Makes :Bosch /Siemens Cerberus / Morley / Edwards |
| 346 | Isolator ModuleSITC of DIN Rail type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable with Operating voltage 15 to 30 Vdc. The module shall be conforming to BS5839 Standards and Duly Approved by LPCB/UL/FM/relevant IS/EN Standard. Makes Make Bosch /Siemens Cerberus / Morley / Edwards |
| 347 | Supply, Installation, Testing and Commissioning of 16 Zone Voice Evacuation Controller, 16 Zone Paging system with pre-recorded messages for voice evacuation, simple integration with Fire Alarm panels to automatically activate 15 zones individually or all 16 zones collectively through potential free contact closure, supports automatic evacuation announcement upon fire alarm triggering, built-in media player with USB Reader (MP3 / WAV / FLAC), Bluetooth V5.0, FM Radio and SD Card support, 1 Line Input, PTT Microphone with mix mode and emergency priority paging output, provides 16 broadcast zone output function, peak power per zone 1000W, total combined power 2000W, with pre-recorded customizable evacuation messages. |
| 348 | Supply, Installation, Testing & Commssioning of 1X500W Class-D Amplifier, which can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protectionand High Efficiency Class D Power Amplifier, 500W, 100V/70 Output, with 100 - 240 VAC input and 24 VDC backup power SupplyApproved Makes: Honeywell X-618/ Rux / Bose/ Bosch Praesensa |
| 349 | Supply, Installation, Testing & Commssioningof 6W Ceiling Speaker with max SPL1M/1W 95dB . Frequency response of 125Hz-16KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W.Approved Makes: Honeywell X-618/ Rux / Bose/ Bosch Praesensa |
| 350 | Supply, Installation, Testing & Commssioningof 6W Wall mount Speaker with max SPL1M/1W 95dB . Frequency response of 125Hz-16KHz. The speaker shoud have tappings at 6W/3W.Approved Makes: Honeywell X-618/ Rux / Bose/ Bosch Praesensa |
| 351 | Supplying & laying of 2x1.5 sqmm FRLS armoured cable, 600/1000V rated with annealed copper conductor heavy dutyPVC insulated, PVC armoured conductor cables 1100 V grade including necessary supportclamps and connection lugs complete in all respects. |
| 352 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable Single pair, 2-core, 1.5 sqmm |
| 353 | Supply, Installation, testing and commissioning of Cat6A Tool less Information outlet for Data & Voice. Cat6A U/UTP RJ45 socket with built in crimping mechanism with capability of retermination without refreshing the wires. Toolless RJ45 Information outlet with insertion cycle (in & out) upto 2500 times (I/O) along with front side Label holder and transparent shutter. The Information Outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3bt standard for POE++ application as required. Make-3C3/Commscope/Legrand |
| 354 | Supply& Fixing of Face Plate : Single/Double Port Flush & surface mount. Polycarbonate Hi-Grade Plastic FR Grade with ABS underplate & CRCA metal fram & UV Resistant 850 degree C/ Glow Wire Test. The face plate should be compatible for Cat5e, Cat6 range of RJ45 and different types of AV connectors.The face plate Size should be of minimum 86x86mm as required.Make-3C3/Commscope/Legrand |
| 355 | Supply& Fixing of CAT6A UTP 26 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life, Conforming to the following standards like Smoke density: Series IEC 61034 / IEC 61034-2, EN 61034-2, IEC 60754/IEC 60754-2, EN 60754-2, IEC 60332-1/60332-1-2, UL VW-1 with tensile strength >50N, Number of Insertion upto 2500 Duty Cycle as required.Make-3C3/Commscope/Legrand |
| 356 | Supply& Fixing of CAT6A UTP 26 AWG Patch Cord -2 mtr with cross separator , Manufactured from stranded wires for longer flex-life, Conforming to the following standards like Smoke density: Series IEC 61034 / IEC 61034-2, EN 61034-2, IEC 60754/IEC 60754-2, EN 60754-2, IEC 60332-1/60332-1-2, UL VW-1 with tensile strength >50N, Number of Insertion upto 2500 Duty Cycle as required.Make-3C3/Commscope/Legrand |
| 357 | Supply, Installation, testing and commissioning of 24 port Cat 6A19\" Modular Toolless Patch Panel (loaded) enable all possible combinations of the various types of cable (UTP, FTP, SFTP) mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19” chassis and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19” uprights of the enclosure. Include rear cable support with plastic cable guides to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19” rails without use of cage-nuts.These may be used to secure the connections of wifi access points, IP cameras, servers, or other critical devices. Front Removal IO\"s option for maintenance and trouble shooting with 6 Different Colours Labels for Labelling & Identification of Individual Ports. Tested and guaranteed under dual circuit IEEE PoE++ more than 90W for up to 2500 on-load connections / disconnectionsMake-3C3/Commscope/Legrand |
| 358 | Supplying & Laying of4-pair CAT 6A U/UTP LAN Cable with 23 AWG Solid bare Copper, 2 Insulated conductors twisted together, LSZH, Polyolefin Insulation, 1.03 + 0.05 mm Insulation dia.Supports Gigabit Ethernet (10GbaseT) standard., Operates at bandwidth up to 500MHz, ANSI/TIA-568.2-D & ISO/IEC 11801 as requiredMake-3C3/Commscope/Legrand |
| 359 | Supply and fixing of 6 core outdoor SingleMode Optical Fiber of size 09/125μm. outdoor rated with U/V stabilized sheath, gel filled , Attenuation (of cable with fibers) - IEC 60793-1-40 Maximum value of cable at 1310nm-1625nm ≤ 0.39 dB/km, IEC 60793-2-50 class B.1.3; EN 60793-2-50 class B1.3: ITU Recommendation G.652.D , category OS1/2 ISO/IEC 11801:2002 category OS1/2. IEEE 802.3-2002 incl. amendment 802.3ae, through existing GI/HDPE/ Hume pipe or on cable trays inside the cable duct including all necessary fixing accessories e.g. cable ties, hardware etc.Make-3C3/Commscope/Legrand |
| 360 | Supplying & Fixing of Fiber Optic LC style fully loaded LIU (FOPP), 19\" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 24 Nos ofduplex LC couplerswith all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.Make-3C3/Commscope/Legrand |
| 361 | Supplying & Fixing of Fiber Optic LC style fully loaded LIU (FOPP), 19\" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos ofduplex LC couplerswith all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.Make-3C3/Commscope/Legrand |
| 362 | Supply, Installation, testing and commissioning of 10 GB - 9/125μm OS1/2LC LSZH Pigtails SM 9/125mm including fiber Splicing confirming to IEC 61754-20 Type A1a.2, Singlemode fibre conforms to ITU-G652, ANSI/TIA & Telcordia standardMake-3C3/Commscope/Legrand |
| 363 | Supply, Installation, testing and commissioning of 10 GB - 9/125μm OS1/2 -LC-LC Duplex Fiber Patch Cord - 2 mtrs. Conform to LC-IEC 61754-20 IEC 61300-3/4,61300-3-34,IEC 61300-3-6,61300-2-2 ANSI-TIA, IEC 60793-1-40 , IEC 60792-1-42Make-3C3/Commscope/Legrand |
| 364 | Access Switch 8 Port-POESITC of 8 x 10/100/1000 Mbps RJ-45 (all support PoE),2 x Dedicated Gigabit SFP slots for fiber uplinks,IEEE 802.3af,Up to 15.4W, Smart Managed (Web-browser GUI, SNMP, RMON), Store-and-forward, 20 Gbps full-duplex Make-3C3/Commscope/Legrand |
| 365 | Access Switch 24 Port-POESITC of Layer-2Switch, 24 # 10/100/1000 Base-T auto-sensing PoE+ ports with2 dedicated 100/1000 Base-X Fiber SFP ports, Bandwidth: 52 Gbps non-blocking, Forwarding modes: Store-and-forward, 8 Priority queues, Weighted Round Robin (WRR) and Strict Priority, VLAN: 64, 128 Multicast groups, Auto Power Down, PoE budget: 380W, IEEE 802.3 Ethernet, IEEE 802.1Q VLAN Tagging, Network Storm Protection, DoS attacks prevention, IP-based ACLs (IPv4 and IPv6), IEEE 802.1x Radius Port Access Authentication, IEEE 802.3ad - LAGs - LACP ( (8 LAGS with max. of 8 members in each LAG)), IGMP Snooping, Admin access control via Radius and TACACS+, Smart Control Center (SCC) for multiswitch management, Dual Software (firmware) image, Per device: Power, Fan and PoE Power Status complete as requiredMake-Cisco / Arista / Netgear / Juniper |
| 366 | Access Switch 48 Port-NetworkSITC of Layer-2Switch, 48 x 10/100/1000 Mbps auto-sensing Gigabit Ethernet ports, 4 x SFP fiber slots (2 are combo ports, 2 are dedicated SFP ports on newer versions), 100 Gbps (non-blocking architecture), 74.4 Mpps,256 VLANs (IEEE 802.1Q, Voice VLAN, Protocol-based VLANs), 802.1x authentication, DoS prevention, Dynamic ARP inspection, ACL filtering, Web-based GUI, Smart Control Center, SNMP v1/v2c/v3, SyslogMake-Cisco / Arista / Netgear / Juniper |
| 367 | SITC of 24 x 10/100/1000 Mbps auto-sensing Gigabit Ethernet ports and 2 dedicated 1000M SFP fiber ports for fiber connectivity,Bandwidth: 48 Gbps, Forwarding Mode: Store-and-forward, Web-based graphical user interface (GUI), SNMP v1/v2C/v3, RMON, Syslog, and potentially remote/cloud management via the NETGEAR Insight app/portal for newer versions (v6), VLAN Support: Supports up to 256 VLANs (IEEE 802.1Q tagged), Security:IEEE 802.1x RADIUS port access authentication.Make-Cisco / Arista / Netgear / Juniper |
| 368 | Supplying Installation testing and Commissioning of 24 Port stackable managed L3 Fiber Switch10/100/1000 BASE-X SFP+ Port, with 4 x 10/25GbE SFP+ Port, Out of band : 1 x RJ45 10/100/1000BASE-T (back), 2 x USB-A (back), Quad-Core Cortex-A57 ARMv8 1.8Ghz 64-bit, Flash: 512 MB, Stack height: 8 switches, Switching fabric: 680 Gbps Line-Rate, ARP/NDP= 4K/512, Number of routes: 894 IPv4 Unicast routes, IGMPv2/3 Snooping Support, Multicast Static Routes (IPv4, IPv6), IGMP Proxy, DHCP Client, Server (IPv4, IPv6), Static Routing, VLAN, IEEE 802.1p CoS, Auto-VoIP, DoS attack protection, MAC, IPv4, IPv6, TCP, UDP ACL, Port MAC Locking, GARP, ISDP, GUI, Persistent log supported, Operating Temperature: 32° to 122°F (0° to 50°C), Certification: CE, FCC, EN etc. as required. Make-Cisco / Arista / Netgear / Juniper |
| 369 | Supplying Installation testing and Commissioning of Cluod Managed PoE Dual-Band WiFi 6 Wireless Access Point having One 100/1000/2.5GBASE-T Gigabit Ethernet (RJ-45) ports with Auto Uplink™ (Auto MDI-X) supporting IEEE 802.3af or 802.3at Power over Ethernet (PoE), Adjustable Transmit Power Control with 5 year cloud licence as requriedMake-Cisco / Arista / Netgear / Juniper |
| 370 | Supplying Installation testing and Commissioning of SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1min length complete in all respect. Make-Cisco / Arista / Netgear / Juniper |
| 371 | Supplying Installation testing and Commissioning of Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) SR Optics Make-Cisco / Arista / Netgear / Juniper |
| 372 | Supply & Fixing of 15 U Wall Mount Rack (600W x 600D), assembled, UL Certified rack (RAL 7035 in Pastal fine texture OR RAL 9005 in Black fine texture) with Sheet steel riveted metal frame, Top and bottom cover with brush cable entries, confirming to following standards - IEC 60529 EN 60529 (IP20), IEC 62262 EN 62262 (IK08), DIN 41494, EIA 310, IEC 60297 as requiredMake-3C3/Commscope/Legrand |
| 373 | Supply & Fixing of 27U Floor Stand 42U x 600W x 1000D rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards- IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour - Combination of RAL 7037 (For frame) & RAL 7035 (For other parts) with fine texture, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Monitor Shelf etc. should be from same OEM as requiredMake-3C3/Commscope/Legrand |
| 374 | Supply, Installation and Commissioning of smart IP PBX system with supports 999 IP users, 240 port Analoue and connects through VoIP, GSM, and PSTN networks Rack mountable Appliance based IP Voice communication System with below config etc as requiredPRI - 1 Nos. , Analuge Trunk -8 Nos. IP Extension -70 Nos , SIP Trunk 30 CH, Analuge Extn 172, 1 PRI , Auto Attendant |
| 375 | Supply, Installation and Commissioning of IP phone (same make as of EPABX) to be supported both H.323 integrated mini switch 10/100/1000 ports,PoE , HD voice, caller ID, call forwarding, voicemail, full-duplex speakerphone, headset support, encryption (TLS/SRTP) ,128x64 graphical LCD with icons |
| 376 | Supply, Installation and Commissioning of IP phone of (same make as of EPABX) suitable to be supported both H.323 and SIP, Built-in 16 DSS Keys for Feature, Line, and Extension monochrome graphical display with backlit and optical call alert, 240 x 64 Graphical LCD with Backlit,control keys and navigator hands free talking (full duplex) interface of headset jack integrated mini switch 10/100/1000 ports,PoE , Audio Presence HD G.722 etc. complete as reqd. etc as as required . |
| 377 | Supply, Installation and Commissioning of corded landline phone with a 16-digit LCD display, FSK/DTMF compatible caller ID, and a two-way speakerphone. Key features include memory for 30 incoming and 5 outgoing calls, redial, pause, and adjustable ringer and LCD contrast. It supports both tone and pulse dialing and can be desk or wall-mounted. |
| 378 | Supply, Installation and Commissioning of MDF 200 Pair Krone Module |
| 379 | Supply, Installation and Commissioning of MDF 100 Pair Krone Module |
| 380 | Supply, Installation and Commissioning of 100 P ABC 0.5MM, Arourd, jally Filled Telecphone Cable |
| 381 | Supply, Installation and Commissioning of 50 P ABC 0.5MM, Arourd, jally Filled Telecphone Cable |
| 382 | Supply, Installation and Commissioning of 2 pair cable 0.5MM ABC, PVC Insulated, Un-Armourd, Sheated Telecphone cable |
| 383 | Supply, Installation and Commissioning of fixed type dome CCTV Camera, Resolution 2MP (1920 x 1080) Full HD, Progressive Scan CMOS Image Sensor, Fixed , IR Range minimum 30 meters, Video Compression H.265 / H.264, Power Supply PoE / 12V DC, IP66 Weatherproof (for outdoor use), True Day/Night with ICR, Video Analytics including Motion Detection & Tamper Alarm, suitable for Indian climatic conditions, complete with all accessories, mounting hardware, connectors, termination, configuration, integration with NVR/VMS, testing, commissioning and handover as per approved drawings and client requirements. |
| 384 | Supply, Installation and Commissioning of fixed type bullet CCTV Camera, Resolution 2MP (1920 x 1080) Full HD, Progressive Scan CMOS Image Sensor, Fixed , IR Range minimum 30 meters, Video Compression H.265 / H.264, Power Supply PoE / 12V DC, IP66 Weatherproof (for outdoor use), True Day/Night with ICR, Video Analytics including Motion Detection & Tamper Alarm, suitable for Indian climatic conditions, complete with all accessories, mounting hardware, connectors, termination, configuration, integration with NVR/VMS, testing, commissioning and handover as per approved drawings and client requirements. |
| 385 | Supply, Installation, Testing & Commissioning of 64 Channel Network Video Recorder (NVR) , supporting minimum 64 IP cameras, with 8 SATA ports for internal HDD storage, compatible withIP cameras, supporting H.265 / H.264 video compression, recording resolution up to 1080p / 4MP or higher, real-time live view, playback and backup, HDMI & VGA display output, dual stream support, smart search and event recording, motion detection and alarm management, ONVIF compliant for multi-brand camera integration, network interface RJ45 Gigabit LAN, USB ports for backup, remote monitoring via web and mobile application, user management and secure authentication, complete with power adapter, rack / desktop mounting accessories, system configuration, integration with complete CCTV system, testing, commissioning and handover as per approved drawings and client requirements. |
| 386 | Supply, Installation, Testing & Commissioning of 8 TB Surveillance Hard Disk Drive (HDD), specially designed for 24x7 continuous CCTV recording, compatible with Impact / Honeywell Network Video Recorders (NVR), SATA interface, high reliability and performance for surveillance applications, optimized for low power consumption and heat dissipation, supporting multi-stream video recording environment, shock and vibration resistant, complete with installation in NVR. |
| 387 | \"Supply, installation, testing & commissioning of Workstation for CCTV Monitoring having minimum configuration:Processor - Intel i7 core processor, OS- Windows 10 Professional (64-bit), 16GB RAM, Graphics Card- 2GB or more, Hard Disk - 1TB, 3 Display port (3 HDMI output for Monitors), 4 USB port, CD Drive, LAN Port, Preloaded Antivirus, Keyboard & Mouse with standard accessories. |
| 388 | Providing a signs made as using Cosign India make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa madefrom virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is double sided 50mm depth profile with media accomodation depth of 6 mm media of ACP acrylic upto 5 mm thickness can be pasted directly on frames or attched on frame with help of dual lock tape.Sign can be edge lite with help of edge lite led modules,led of LUCOLED make EL31 , fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 389 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 390 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with10 years warranty under normal working conditions. Sign flip profiles with 32 mm visible border.Sign has high quality plastic moulded base with slightly flexible in nature, with wall mountiing screw position hidden beneath the flip profiles. and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 391 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 Years warranty under normal working conditions.Sign is double sided with 2 aluminium profiles connected with each other with 2 plastic moulded endcaps.Galvanised iron multistrand twisted 2 mm diameter wire (upto1.5 meter in length) with Stainless steel eco-suspension clips screw fitted directly in ceiling (rigid base) engaged with wire stainless steel eco suspension clips with wire adjustment mechanism.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 392 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 Years warranty under normal working conditions.Sign is double sided with 2 aluminium profiles connected with each other with 2 plastic moulded endcaps.Galvanised iron multistrand twisted 2 mm diameter wire (upto1.5 meter in length) with Stainless steel eco-suspension clips screw fitted directly in ceiling (rigid base) engaged with wire stainless steel eco suspension clips with wire adjustment mechanism.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 393 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 394 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 395 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 396 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 397 | Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virginhomogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 398 | Providing sign of Cosign make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa Made from virginhomogeneous aluminium billet) with premium grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty under normal working conditions. Profile to form frame with overall depth of 10 mm with media of thickness upto 3mm. 2 mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated corners with grub screws. Installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 399 | Providing sign of Cosign make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa Made from virginhomogeneous aluminium billet) with premium grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty under normal working conditions. Profile to form frame with overall depth of 10 mm with media of thickness upto 3mm. 2 mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated corners with grub screws. Installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 400 | Providing ready sign & fixing at location a Cosign make emergency exit sign- illuminated, surface mount (wall or ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180 mins) .Battery life of 300 cycles of charge & discharge Li- ion battery 3.7 Volt, 100 mA, Charge time of 24 hours. Input voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of protection IP20 (rating for protection against solid object upto 12 mm) white light colour full back (white colour) LED illumination with green white coloured graphic inserted on both sides on 0.4 mm PC (sizes, texts, symbols or graphics as per standard safety norms & regulations) graphic options of -left ,right, up staircase down staircase. Test facilty button self test plus auto self test, opreration in maintained and non maintained mode (power saver mode).Sign with 12 months warranty for electric circuit & 6 months warranty for battery. Sign provided with dual mounting arrangement of mounting on wall & celing both ( with flat rigid support/base).Sign is including all connection wires (upto 1 mtr) & high tensile strength zinc coated self tapering screws (4 nos with screw wall plastic packing), installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. |
| 401 | Supply Installation testing commissioning of 65\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 300 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 402 | Supply, Installation, Testing, and commissioning of Unified collaboration device to work on Native Microsoft Teams Room mode. It should be possible to change the configuration from native teams to native zoom (vice versa) on site.Camera: Minimum 20 Megapixels, 1 in. sensor camera with 7x digital zoom, and FoV minimum 83º.Should be able to track people based on voice (speaker tracking) , frames everyone in the room (Group framing), based on the selection from touch interface.Should have at least three camera setup that captures room in 4K, automatically tracks and frames people, and enhances the video content using AI.Should have optional camera shutter which works automatically based on device usage and with color indication for users’ privacy.Audio: Should have Dual 9-watt speakers.Should have minimum 8 linear array microphone, and inbuilt DSP for AEC, AGC, dynamic noise suppression, adaptive beamforming, speaker volume control.Ports: Should have 1x LAN, 1x HDMI input for content sharing & 2x HDMI outputs.Video Formats: Should support video output resolution up to 4K & HDCP 2.2.Touch Control: Should be supplied with 10 in. capacitive multi-touch TFT active-matrix color LCD, 1920 x 1200 pixels, which power over ethernet, should be able to control Microsoft Teams rooms.Ethernet parameter: Should support ethernet parameters 1000 Mbps, TCP/IP, UDP/IP, SSH, SSL, TLS, SFTP, IEEE 802.1X, SNMP, IPv4, IPv6, Active Directory® service authentication, HTTPS.Warranty & Support: Should be shipped with 3 Years of warranty on product, OEM must have tollfree number, so that customer can reach out directly to OEM during warranty period.Certification: Should be Microsoft Teams room certified hardware.USB Passthrough: USB passthrough capabilities for BYOD/BYOM for conducting meeting from laptops, to be available on the device. |
| 403 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 404 | 1) Supply, Installation, Testing and commissioning of 4K wired, wireless presentation and wireless collaboration device.2) User should be able to share content wirelessly using app, Google Chrome web browser, Miracast screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.3) User should be able to share content via wired by using 1x HDMI and 1x USBC port on table/cable manager. (Tx & Rx should be used to transport AV signal on CAT from cable manager on table to wireless presenter installed at display end)4) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied.5) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application via wired HDMI + USB-A port for older laptops and 1xUSBC for new laptop for bring your own meeting experience from table/cable manager (Tx & Rx should be used to transport AV and USB signal on CAT from cable manager on table to wireless presenter installed at display end).6) Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.7) Should have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.8) Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS.9) Should be supplied with 2x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.10) Should have 1x HDMI Input + 1xUSBA/USBC, 1xUSBC (Audio, Video, USB), 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals (certified Audio/Video) connection.11) Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).12) Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.13) Should be able to create its own Wi-Fi network, for guest users, for content sharing.14) Content Protection: HDCP 2.215) Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).16) Should be supplied with necessary wireless presenter, dongle/adapter, Tx, and Rx for extending HDMI+USBA, USBC and USB peripherals on table for BYOD & BYOM experience to achieve the specification. |
| 405 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 406 | Supply Installation testing commissioning of 85\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 400 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 407 | Supply Installation testing commissioning of 65\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 300 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 408 | Supply Installation testing commissioning of Ceiling microphone with automatic dynamic Beamforming technology, The beam will automatically detect the position of the person speaking and will follow the person around the room at all times. It should have 2 x Dante digital audio (Redundancy), Analog audio out (Phoenix 3-pin), and Ethernet for Control and PoE connectivity ports. The coverage of the ceiling microphone should be min 800 square feet or more. It should have a true voice lift feature to increase audio intelligibility above the ambient noise floor. It should support IT industry standards like IEEE 802.1x. It can be controlled through software that can control and monitor the microphone in any network. It should have min 100 dB SPL, 5ms latency, and min 90dBA or higher dynamic range. High-precision audio settings for maximum control, setting to exclude (min 5) and prioritize the areas of the room. It should certified from Microsoft Teams andZoom Video conferencing applications. It should have UL 62368 certification (including UL 2043 testing and compliance) and safety certifications. Supply of microphone on/off button with XLR-5 connector requires 12V DC external power supply. |
| 409 | Supply, Installation, Testing, and commissioning of 2-Way In-Ceiling Speaker.Should have Woofer - 4 inch, and Tweeter 0.79 inch.Should have Frequency Range: 80 Hz to 20 kHz (-10 dB)Should have Frequency Response : 100 Hz to 15 kHz (±3 dB)Should support Transformer Taps 7.5W/15W/30W at 70V, 100VShould have Sensitivity: 89 dB @ 1W/1mShould have 30 Watts program power handling.Should have 120° conical coverage.Should be UL 94V-0 flame rated.Compliance: UL 1480, UL 2043, CE, FCC. (Additional BIS to be shared if applicable). |
| 410 | Supply, Installation, Testing and commissioning of Class D Amplifier.Should be able to output 4-channel (75W /channel) or 3-channel (75W-75W-150W) or 2-channel (150W/channel) or 1 channel up to 300 WShould be able to configure on Lo-Z, Hi-Z operation.Should have Frequency Response 20 Hz to 20 kHz ±0.5 dB at 1 W.Should have S/N Ratio >103 dBA, 20 Hz to 20 kHz.Should have THD+N <0.1% at 1 kHz.Should have protection against overheating, excessive input, overloaded speaker lines.Should be Energy Star certifiedShould automatically go on standby when no signal is detected.Should have 1x control/connection port to enable/disable standby mode.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 411 | Supply Installation testing commissioning of Digital Signal Processor with a minimum of 4 or more microphone/line inputs that include phantom power and AEC. It should also have 8 or more line outputs,The sampling rate should be 48kHz or better and the DSP should be expandable for port expansion. It should have a minimum of 64x64 Dante channels for digital audio transfer , DSP must support with electical features of THD+N (22Hz to 22kHz) : 0.002% (1kHz @ +4dBu); EIN : <125dBu, unweighted (20Hz to 20kHz); Dynamic Range : 110dB, unweighted; Propagation Delay 4ms; Crosstalk, input to input, 1kHz: <110dB; Phantom Power +48VDC up-to 100mA maximum;andcompliant to FCC Part 15 B and conform to CE and ICES-003:7 safety requirements.. The DSP should support control with an app via iOS and Android devices or any third-party control system. Additionally, it should have built-in filters, feedback suppression, and other necessary features as per specifications. |
| 412 | Supply Installation testing commissioning of USB 2.0 to Dante network endpoint, PoE-powered with single CatX cable and suitable for mounting under the table or behind a display, with UC mute sync. |
| 413 | 1) SITC of customizable video conference room solution for use with the MICROSOFT TEAM Rooms intelligent communications platform.2) It is preferrable to convert native Teams room to native Zoom room system if the platform of user changes.3) The collaboration hardware / codec provided should support Windows® 10 IoT Edition OS, 100/1000 Mbps Ethernet connectivity, minimum dual displays output and 10\" Tabletop touch screen.4) Tabletop Touch interface should be powered over ethernet for 24x7 use and which will be used for controlling the Microsoft Team calls and flexible room controls.5) This hardware should enable integration with your choice of displays, cameras, speakers, microphones, mixers, switchers, and audio-conferencing interface (or speaker phone)6) Engine should have 2 x output to be connected to 2 displays, 1 Input for sharing wired content during the call, USB 2.0 and 3.0 supported multiple ports foraccessories connectivity like camera, DSP, speakerphone etc.7) The touch screen offered with this package should be able to operate Microsoft Teams Room call Control features, also provide control of room lighting, shades, thermostats, and other equipment used in addition with the control system. It should also have USB-C port and USB-A port for BYOD / BYOM / USB Passthrough feature built in for users to use their own UC conference platform from laptop without rebooting the device.8) Package should be provided with necessary required cables, converters, POE, additional accessories, and components to be included to meet thesaid functionality.9) It should support IEEE 802.1X, SSL, TLS, SSH, SFTP (SSH File Transfer Protocol), password login, HTTPS secureprovisioning, IEEE 802.3at compliant.10) Should comply to CE, UL, FCC, ROHS. (Additional BIS to be shared if applicable)11) Should be Microsoft Teams certified Hardware. |
| 414 | Supply Installation Testing and commissioning of intelligent 20x PTZ Camera supporting minimum below parameters:1) Technology: Intelligent PTZ camera with visual AI for presenter Tracking Capability.2) Camera movement: Automatically pans, tilts, and zooms using dual camera technology3) Optical Zoom: Minimum 20x4) Image Sensor: Minimum 1/2.8 Sony CMOS Sensor.5) Focal Length: F=5.2-94 mm6) Video Format: Minimum 1080p607) Video Outputs: 3G-SDI, HDMI®, USB, ONVIF, RTSP, NDI8) Shutter Speed: 1/50-1/10,000 sec9) Illumination: 2 lux10) FOV Reference Camera: Horizontal: 104°11) FOV Main Camera: Horizontal: 56°12) Dual camera design: Wide angle reference camera & the PTZ Main camera13) Control: VISCA/TCP, VISCA/UDP, PELCO-D, PELCO-P, ONVIF14) Minimum 1x RS-485 port for controlling.15) Visibility Indicator: Should have bicolor LED, to show device activated and standby mode16) Reset: Hardware reset17) Presenter Tracking: Able to track group of presenters with option to add blocking zones (display, doors, glass openings etc) to avoid false tracking.18) Compliance: CE, FCC (BIS to be shared additionally, as applicable)Camera & Camera switching solution should be from one manufacturer only, to avoid any compatibility issue and meet the room functional as per requirement and user requirement. |
| 415 | Supply, Installation, Testing and commissioning of 4K60 4:4:4 8x8 HDMI matrix SwitcherShould have eight HDMI inputs and eight HDMI outputsShould have two stereo line-level audio output, to de-embedded audio from any of the eight HDMI inputsVideo Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsContent Protection: HDCP 2.3Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould be controllable via RS-232/RJ45 via external control system, Webbrowser supportCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 416 | Supply, Installation, Testing and commissioning of 2x1 Transmitter for HDMI Extension over CAT CableShould have two HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 417 | Supply, Installation, Testing and commissioning of Transmitter for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 418 | Supply, Installation, Testing and commissioning of Receiver for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI output and one HDBT Lite/RJ45 input.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 419 | Supply, Installation, Testing and commissioning of Transmitter and Receiver for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 420 | Supply, Installation, Testing, and commissioning of HDMI to USB Converter.Should have one HDMI input, 1x analog audio input and one HDMI output with 1x parallel USB 3.0 outputResolution support: 4KShould have 1080p @ 60 fps uncompressed at USB for superior outputShould have USB Video Class (UVC) and USB Audio Class (UAC) standards, to work with video capture or streaming software available in marketsContent Protection: HDCP 2.2Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).USB powered |
| 421 | Supply, Installation, Testing and commissioning of AV Control System with control ports.Should have Quad Core processor / multicore CPU / Ultra-Fast processor, for faster processing and advanced automated system requirements.Should be able to control two rooms simultaneously, for future proof and backup purpose.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be JITC/FIPS/NIAP certified.Should have BACnet communication protocol, which allow integration with third-party building management systems (HVAC, security, and other systems) over Ethernet.Should have minimum 2 GB SDRAM and minimum 8 GB flash memoryShould have minimum, 6x IR/serial, 1x Bidirectional RS-422/485 port, 2x Bidirectional RS-232, 6x I/O, 8x low voltage relay.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Control processor & Touch Control interface should be from same OEM, and must not require any internet connectivity for configuration, programming and running.Should be shipped with license to control the room from PC/Laptop using UI. |
| 422 | Supply, Installation, Testing and commissioning of 4K wireless presentation and wireless collaboration device.User should be able to share content wirelessly using app, Google Chrome web browser, Miracast® screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.User should be able to view minimum 2x wirelessly shared sources, side by side on a single screen and should work on last in first out (LIFO) sequence for content sharing.User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied, for bring your own meeting experience.Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.Should be able to configure with Microsoft Exchange Server (for Outlook® and Microsoft 365® software users), Google Calendar™, room scheduling software for room booking and meeting details to appear onscreenShould have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be supplied with 1x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.Should have 1x HDMI Input, 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals connection.Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.Should be able to create its own Wi-Fi network, for guest users, for content sharing.Content Protection: HDCP 2.2Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 423 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 424 | Supply Installation testing commissioning of 8x1G PoE+ AV Over IP SwitchSwitch having 1x1G and 1xSFP Managed AV Switch, Shall support Switching Fabric: 20 Gbps, Shall Support IGMP Support, Jumbo Frame Support and Fanless |
| 425 | Supply & Fixing of 17U Floor Stand 17U x 600W x 800D rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards- IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour - Combination of RAL 7037 (For frame) & RAL 7035 (For other parts) with fine texture, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Monitor Shelf etc. should be from same OEM as required |
| 426 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 427 | Supply Installation testing commissioning of 75\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 400 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 428 | Supply, Installation, Testing, and commissioning of Unified collaboration device to work on Native Microsoft Teams Room mode. It should be possible to change the configuration from native teams to native zoom (vice versa) on site.Camera: Minimum 20 Megapixels, 1 in. sensor camera with 7x digital zoom, and FoV minimum 83º.Should be able to track people based on voice (speaker tracking) , frames everyone in the room (Group framing), based on the selection from touch interface.Should have at least three camera setup that captures room in 4K, automatically tracks and frames people, and enhances the video content using AI.Should have optional camera shutter which works automatically based on device usage and with color indication for users’ privacy.Audio: Should have Dual 9-watt speakers.Should have minimum 8 linear array microphone, and inbuilt DSP for AEC, AGC, dynamic noise suppression, adaptive beamforming, speaker volume control.Ports: Should have 1x LAN, 1x HDMI input for content sharing & 2x HDMI outputs.Video Formats: Should support video output resolution up to 4K & HDCP 2.2.Touch Control: Should be supplied with 10 in. capacitive multi-touch TFT active-matrix color LCD, 1920 x 1200 pixels, which power over ethernet, should be able to control Microsoft Teams rooms.Ethernet parameter: Should support ethernet parameters 1000 Mbps, TCP/IP, UDP/IP, SSH, SSL, TLS, SFTP, IEEE 802.1X, SNMP, IPv4, IPv6, Active Directory® service authentication, HTTPS.Warranty & Support: Should be shipped with 3 Years of warranty on product, OEM must have tollfree number, so that customer can reach out directly to OEM during warranty period.Certification: Should be Microsoft Teams room certified hardware.USB Passthrough: USB passthrough capabilities for BYOD/BYOM for conducting meeting from laptops, to be available on the device. |
| 429 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 430 | 1) Supply, Installation, Testing and commissioning of 4K wired, wireless presentation and wireless collaboration device.2) User should be able to share content wirelessly using app, Google Chrome web browser, Miracast screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.3) User should be able to share content via wired by using 1x HDMI and 1x USBC port on table/cable manager. (Tx & Rx should be used to transport AV signal on CAT from cable manager on table to wireless presenter installed at display end)4) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied.5) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application via wired HDMI + USB-A port for older laptops and 1xUSBC for new laptop for bring your own meeting experience from table/cable manager (Tx & Rx should be used to transport AV and USB signal on CAT from cable manager on table to wireless presenter installed at display end).6) Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.7) Should have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.8) Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS.9) Should be supplied with 2x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.10) Should have 1x HDMI Input + 1xUSBA/USBC, 1xUSBC (Audio, Video, USB), 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals (certified Audio/Video) connection.11) Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).12) Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.13) Should be able to create its own Wi-Fi network, for guest users, for content sharing.14) Content Protection: HDCP 2.215) Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).16) Should be supplied with necessary wireless presenter, dongle/adapter, Tx, and Rx for extending HDMI+USBA, USBC and USB peripherals on table for BYOD & BYOM experience to achieve the specification. |
| 431 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 432 | Supply, Installation, Testing, and commissioning of 10 Inch Room scheduler.Should support direct integration with popular room booking software\"s like Microsoft Teams Rooms, Zoom Room, Microsoft Exchange Server and Office 365 software, Google Calendar, and G Suite software, CollegeNET 25Live software, and Ad Astra software.Should be able to integrate with on-premises room scheduling software from same OEM.Should be supplied with light indicator and glass mounting accessories from same OEM.Contrast: 1000:1Resolution: 1920 x 1200 pixelsColor Depth: 24 bits, 16.7M colorsBrightness: 400 nits (cd/m²)Viewing Angle: Minimum ±80° horizontal, ±80° verticalAspect Ratio: 16:10/16:9, Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Should be able to communicate to customer network via physical LAN connection, Wi-Fi.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Should have option to integrate with occupancy sensor via relay/RJ 45 connection.Should have proximity sensor built-in for automatic screen wakeup when users approaches and screen brightness control. |
| 433 | Supply Installation testing commissioning of 98\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 400 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 434 | Supply Installation testing commissioning of 85\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 400 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 435 | Supply Installation testing commissioning of Ceiling microphone with automatic dynamic Beamforming technology, The beam will automatically detect the position of the person speaking and will follow the person around the room at all times. It should have 2 x Dante digital audio (Redundancy), Analog audio out (Phoenix 3-pin), and Ethernet for Control and PoE connectivity ports. The coverage of the ceiling microphone should be min 800 square feet or more. It should have a true voice lift feature to increase audio intelligibility above the ambient noise floor. It should support IT industry standards like IEEE 802.1x. It can be controlled through software that can control and monitor the microphone in any network. It should have min 100 dB SPL, 5ms latency, and min 90dBA or higher dynamic range. High-precision audio settings for maximum control, setting to exclude (min 5) and prioritize the areas of the room. It should certified from Microsoft Teams andZoom Video conferencing applications. It should have UL 62368 certification (including UL 2043 testing and compliance) and safety certifications. Supply of microphone on/off button with XLR-5 connector requires 12V DC external power supply. |
| 436 | Supply, Installation, Testing, and commissioning of 2-Way In-Ceiling Speaker.Should have Woofer - 4 inch, and Tweeter 0.79 inch.Should have Frequency Range: 80 Hz to 20 kHz (-10 dB)Should have Frequency Response : 100 Hz to 15 kHz (±3 dB)Should support Transformer Taps 7.5W/15W/30W at 70V, 100VShould have Sensitivity: 89 dB @ 1W/1mShould have 30 Watts program power handling.Should have 120° conical coverage.Should be UL 94V-0 flame rated.Compliance: UL 1480, UL 2043, CE, FCC. (Additional BIS to be shared if applicable). |
| 437 | Supply, Installation, Testing and commissioning of Class D Amplifier.Should be able to output 4-channel (75W /channel) or 3-channel (75W-75W-150W) or 2-channel (150W/channel) or 1 channel up to 300 WShould be able to configure on Lo-Z, Hi-Z operation.Should have Frequency Response 20 Hz to 20 kHz ±0.5 dB at 1 W.Should have S/N Ratio >103 dBA, 20 Hz to 20 kHz.Should have THD+N <0.1% at 1 kHz.Should have protection against overheating, excessive input, overloaded speaker lines.Should be Energy Star certifiedShould automatically go on standby when no signal is detected.Should have 1x control/connection port to enable/disable standby mode.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 438 | Supply Installation testing commissioning of Digital Signal Processor with a minimum of 14 or more microphone/line inputs that include phantom power and AEC. It should also have 6 or more line outputs,The sampling rate should be 48kHz or better and the DSP should be expandable for port expansion. It should have a minimum of 64x64 Dante channels for digital audio transfer , DSP must support with electical features of THD+N (22Hz to 22kHz) : 0.002% (1kHz @ +4dBu); EIN : <125dBu, unweighted (20Hz to 20kHz); Dynamic Range : 110dB, unweighted; Propagation Delay 4ms; Crosstalk, input to input, 1kHz: <110dB; Phantom Power +48VDC up-to 100mA maximum;andcompliant to FCC Part 15 B and conform to CE and ICES-003:7 safety requirements.. The DSP should support control with an app via iOS and Android devices or any third-party control system. Additionally, it should have built-in filters, feedback suppression, and other necessary features as per specifications. |
| 439 | Supply Installation testing commissioning of USB 2.0 to Dante network endpoint, PoE-powered with single CatX cable and suitable for mounting under the table or behind a display, with UC mute sync. |
| 440 | 1) SITC of customizable video conference room solution for use with the MICROSOFT TEAM Rooms intelligent communications platform.2) It is preferrable to convert native Teams room to native Zoom room system if the platform of user changes.3) The collaboration hardware / codec provided should support Windows® 10 IoT Edition OS, 100/1000 Mbps Ethernet connectivity, minimum dual displays output and 10\" Tabletop touch screen.4) Tabletop Touch interface should be powered over ethernet for 24x7 use and which will be used for controlling the Microsoft Team calls and flexible room controls.5) This hardware should enable integration with your choice of displays, cameras, speakers, microphones, mixers, switchers, and audio-conferencing interface (or speaker phone)6) Engine should have 2 x output to be connected to 2 displays, 1 Input for sharing wired content during the call, USB 2.0 and 3.0 supported multiple ports foraccessories connectivity like camera, DSP, speakerphone etc.7) The touch screen offered with this package should be able to operate Microsoft Teams Room call Control features, also provide control of room lighting, shades, thermostats, and other equipment used in addition with the control system. It should also have USB-C port and USB-A port for BYOD / BYOM / USB Passthrough feature built in for users to use their own UC conference platform from laptop without rebooting the device.8) Package should be provided with necessary required cables, converters, POE, additional accessories, and components to be included to meet thesaid functionality.9) It should support IEEE 802.1X, SSL, TLS, SSH, SFTP (SSH File Transfer Protocol), password login, HTTPS secureprovisioning, IEEE 802.3at compliant.10) Should comply to CE, UL, FCC, ROHS. (Additional BIS to be shared if applicable)11) Should be Microsoft Teams certified Hardware. |
| 441 | Supply Installation Testing and commissioning of intelligent 20x PTZ Camera supporting minimum below parameters:1) Technology: Intelligent PTZ camera with visual AI for presenter Tracking Capability.2) Camera movement: Automatically pans, tilts, and zooms using dual camera technology3) Optical Zoom: Minimum 20x4) Image Sensor: Minimum 1/2.8 Sony CMOS Sensor.5) Focal Length: F=5.2-94 mm6) Video Format: Minimum 1080p607) Video Outputs: 3G-SDI, HDMI®, USB, ONVIF, RTSP, NDI8) Shutter Speed: 1/50-1/10,000 sec9) Illumination: 2 lux10) FOV Reference Camera: Horizontal: 104°11) FOV Main Camera: Horizontal: 56°12) Dual camera design: Wide angle reference camera & the PTZ Main camera13) Control: VISCA/TCP, VISCA/UDP, PELCO-D, PELCO-P, ONVIF14) Minimum 1x RS-485 port for controlling.15) Visibility Indicator: Should have bicolor LED, to show device activated and standby mode16) Reset: Hardware reset17) Presenter Tracking: Able to track group of presenters with option to add blocking zones (display, doors, glass openings etc) to avoid false tracking.18) Compliance: CE, FCC (BIS to be shared additionally, as applicable)Camera & Camera switching solution should be from one manufacturer only, to avoid any compatibility issue and meet the room functional as per requirement and user requirement. |
| 442 | Supply, Installation, Testing and commissioning of professional hardware for voice-activated multi camera switching solution.Should be able to provide clean switch between the cameras, for broadcast style experience.Should be able to send active speaker, conversation mode(two active speaker), side by side, PIP, active speaker with room view, conversation mode(two active speaker) with room view, presenter tracking along with active speaker etc., feed to far end.Should be able to add blocking zones, to block unwanted audio pickup in the room, to avoid any false trigger of camerasShould support up to 12x cameras, including PTZ, presenter tracking cameras.Should support cameras inputs on SDI/HDMI/NDI.Should have option to connect minimum 7x HD-SDI camera directly.Should have option to connect minimum 1x USB camera directly.Should have USB output, SDI output.Should have Visual AI feature, using which cameras can automatically center participants in camera shots via Auto Framing even if participant moves slightly from their dedicated seating position.Should be compatible and tested with reputed microphone, DSP, and discussion system OEM\"s.Should have advanced technology to avoid excess camera switching during multiple conversation.Should be shipped with software/application using which demonstration can be done about speaker tracking and device (Mic, Cameras) placementShould be controllable via control system.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC. (Additional BIS to be shared if applicable).OEM of camera switcher and camera must be same to achieve the desired functionality as per user’s requirement |
| 443 | Supply, Installation, Testing and commissioning of AV over IP Transceiver (Encoder)Video Codec: JPEG2000 / OEM based high performance video processingEncoder Mode: Should have Input : 1x HDMI + 1x USBA (BYOD/BYOM and USB data to connect to laptop) and 1x USBC (supporting Audio, Video, USB data),Output: 1x RJ45 & 1x SFP to be connected to decoder or network switch, 1x HDMI Loop output for confidence monitor/display.Decoder Mode: Should have Input: 1x RJ45, 1x SFP, Output: 1x HDMI Scaled.Scaled HDMI output having : Widescreen format selection (zoom, stretch, maintain aspect ratio, 1:1)Videowall Processing: Video wall processing up to 8 wide x 8 high, static or dynamic text overlayShould have control ports 2x IR, 1x Bidirectional RS-232 port, 1x RJ 45 for controlling third party devices, without the need to utilize, run any control cables from AV control system.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsContent Protection: HDCP 2.3, AES 128.USB Port: 2x USB port for peripherals and HID (mouse, keyboard, or other USB 2.0 device, USB HID compliant device)Should have 1x Stereo line-level audio input / output (configured)Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be JITC/FIPS/NIAP certified.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Should be able to configure the device as Encoder / Decoder |
| 444 | Supply, Installation, Testing and commissioning of AV over IP Transceiver (Decoder)Video Codec: JPEG2000 / OEM based high performance video processingEncoder Mode: Should have Input : 1x HDMI + 1x USBA (BYOD/BYOM and USB data to connect to laptop),Output: 1x RJ45 & 1x SFP to be connected to decoder or network switch, 1x HDMI Loop output for confidence monitor/display.Decoder Mode: Should have Input: 1x RJ45, 1x SFP, Output: 1x HDMI Scaled.Scaled HDMI output having : Widescreen format selection (zoom, stretch, maintain aspect ratio, 1:1)Videowall Processing: Video wall processing up to 8 wide x 8 high, static or dynamic text overlayShould have control ports 2x IR, 1x Bidirectional RS-232 port, 1x RJ 45 for controlling third party devices, without the need to utilize, run any control cables from AV control system.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsContent Protection: HDCP 2.3, AES 128.USB Port: 2x USB port for peripherals and HID (mouse, keyboard, or other USB 2.0 device, USB HID compliant device)Should have 1x Stereo line-level audio input / output (configured)Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be JITC/FIPS/NIAP certified.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Should be able to configure the device as Encoder / Decoder |
| 445 | Supply, Installation, Testing and commissioning of 4K wireless presentation and wireless collaboration device.User should be able to share content wirelessly using app, Google Chrome web browser, Miracast® screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.User should be able to view minimum 2x wirelessly shared sources, side by side on a single screen and should work on last in first out (LIFO) sequence for content sharing.User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied, for bring your own meeting experience.Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.Should be able to configure with Microsoft Exchange Server (for Outlook® and Microsoft 365® software users), Google Calendar™, room scheduling software for room booking and meeting details to appear onscreenShould have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be supplied with 2x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.Should have 1x HDMI Input, 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals connection.Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.Should be able to create its own Wi-Fi network, for guest users, for content sharing.Content Protection: HDCP 2.2Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 446 | Supply, Installation, Testing and commissioning of AV Control System with control ports.Should have Quad Core processor / multicore CPU / Ultra-Fast processor, for faster processing and advanced automated system requirements.Should be able to control two rooms simultaneously, for future proof and backup purpose.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be JITC/FIPS/NIAP certified.Should have BACnet communication protocol, which allow integration with third-party building management systems (HVAC, security, and other systems) over Ethernet.Should have minimum 2 GB SDRAM and minimum 8 GB flash memoryShould have minimum, 6x IR/serial, 1x Bidirectional RS-422/485 port, 2x Bidirectional RS-232, 6x I/O, 8x low voltage relay.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Control processor & Touch Control interface should be from same OEM, and must not require any internet connectivity for configuration, programming and running.Should be shipped with license to control the room from PC/Laptop using UI. |
| 447 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 448 | Supply Installation testing commissioning of 24x1G PoE+ AV Over IP Switch having 1x1G and 1xSFP Managed AV Switch, Shall support Switching Fabric: 40 Gbps, Shall Support IGMP Support, Jumbo Frame Support and Fanless |
| 449 | Supply & Fixing of 24U Floor Stand 24U x 600W x 1000D rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards- IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour - Combination of RAL 7037 (For frame) & RAL 7035 (For other parts) with fine texture, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Monitor Shelf etc. should be from same OEM as requiredMake-3C3/Commscope/Legrand |
| 450 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 451 | Supply Installation testing commissioning of 65\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 300 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 452 | Supply, Installation, Testing, and commissioning of Unified collaboration device to work on Native Microsoft Teams Room mode. It should be possible to change the configuration from native teams to native zoom (vice versa) on site.Camera: Minimum 20 Megapixels, 1 in. sensor camera with 7x digital zoom, and FoV minimum 83º.Should be able to track people based on voice (speaker tracking) , frames everyone in the room (Group framing), based on the selection from touch interface.Should have at least three camera setup that captures room in 4K, automatically tracks and frames people, and enhances the video content using AI.Should have optional camera shutter which works automatically based on device usage and with color indication for users’ privacy.Audio: Should have Dual 9-watt speakers.Should have minimum 8 linear array microphone, and inbuilt DSP for AEC, AGC, dynamic noise suppression, adaptive beamforming, speaker volume control.Ports: Should have 1x LAN, 1x HDMI input for content sharing & 2x HDMI outputs.Video Formats: Should support video output resolution up to 4K & HDCP 2.2.Touch Control: Should be supplied with 10 in. capacitive multi-touch TFT active-matrix color LCD, 1920 x 1200 pixels, which power over ethernet, should be able to control Microsoft Teams rooms.Ethernet parameter: Should support ethernet parameters 1000 Mbps, TCP/IP, UDP/IP, SSH, SSL, TLS, SFTP, IEEE 802.1X, SNMP, IPv4, IPv6, Active Directory® service authentication, HTTPS.Warranty & Support: Should be shipped with 3 Years of warranty on product, OEM must have tollfree number, so that customer can reach out directly to OEM during warranty period.Certification: Should be Microsoft Teams room certified hardware.USB Passthrough: USB passthrough capabilities for BYOD/BYOM for conducting meeting from laptops, to be available on the device. |
| 453 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 454 | 1) Supply, Installation, Testing and commissioning of 4K wired, wireless presentation and wireless collaboration device.2) User should be able to share content wirelessly using app, Google Chrome web browser, Miracast screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.3) User should be able to share content via wired by using 1x HDMI and 1x USBC port on table/cable manager. (Tx & Rx should be used to transport AV signal on CAT from cable manager on table to wireless presenter installed at display end)4) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied.5) User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application via wired HDMI + USB-A port for older laptops and 1xUSBC for new laptop for bring your own meeting experience from table/cable manager (Tx & Rx should be used to transport AV and USB signal on CAT from cable manager on table to wireless presenter installed at display end).6) Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.7) Should have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.8) Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS.9) Should be supplied with 2x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.10) Should have 1x HDMI Input + 1xUSBA/USBC, 1xUSBC (Audio, Video, USB), 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals (certified Audio/Video) connection.11) Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).12) Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.13) Should be able to create its own Wi-Fi network, for guest users, for content sharing.14) Content Protection: HDCP 2.215) Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).16) Should be supplied with necessary wireless presenter, dongle/adapter, Tx, and Rx for extending HDMI+USBA, USBC and USB peripherals on table for BYOD & BYOM experience to achieve the specification. |
| 455 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 456 | Supply Installation testing commissioning of 75\" Video Display Unit, 3,840 x 2,160 (16:9)| 500 nit | 4,000:1 | VA pannel | DP 1.2 (1), HDMI 2.0 (3) | USB 2.0 x 2 | Stereo mini Jack | RS232C (In/Out), RJ45 | vesa mount 400 x 400 | 2nd Gen. B2B Design Center IR Temperature Sensor Ambient Sensor Auto Level Wi-Fi (2.4/5.0GHz dual) and BT | ENERGY STAR 8.0, EPEAT | 802.1 x (WPA2 Enterprise) | EAP-TLS, EAP-TTLS, EAP-PEAPAC 100 - 240 V, 50/60 Hz |
| 457 | Supply Installation testing commissioning of Ceiling microphone with automatic dynamic Beamforming technology, The beam will automatically detect the position of the person speaking and will follow the person around the room at all times. It should have 2 x Dante digital audio (Redundancy), Analog audio out (Phoenix 3-pin), and Ethernet for Control and PoE connectivity ports. The coverage of the ceiling microphone should be min 800 square feet or more. It should have a true voice lift feature to increase audio intelligibility above the ambient noise floor. It should support IT industry standards like IEEE 802.1x. It can be controlled through software that can control and monitor the microphone in any network. It should have min 100 dB SPL, 5ms latency, and min 90dBA or higher dynamic range. High-precision audio settings for maximum control, setting to exclude (min 5) and prioritize the areas of the room. It should certified from Microsoft Teams andZoom Video conferencing applications. It should have UL 62368 certification (including UL 2043 testing and compliance) and safety certifications. Supply of microphone on/off button with XLR-5 connector requires 12V DC external power supply. |
| 458 | Supply, Installation, Testing, and commissioning of 2-Way In-Ceiling Speaker.Should have Woofer - 4 inch, and Tweeter 0.79 inch.Should have Frequency Range: 80 Hz to 20 kHz (-10 dB)Should have Frequency Response : 100 Hz to 15 kHz (±3 dB)Should support Transformer Taps 7.5W/15W/30W at 70V, 100VShould have Sensitivity: 89 dB @ 1W/1mShould have 30 Watts program power handling.Should have 120° conical coverage.Should be UL 94V-0 flame rated.Compliance: UL 1480, UL 2043, CE, FCC. (Additional BIS to be shared if applicable). |
| 459 | Supply, Installation, Testing and commissioning of Class D Amplifier.Should be able to output 4-channel (75W /channel) or 3-channel (75W-75W-150W) or 2-channel (150W/channel) or 1 channel up to 300 WShould be able to configure on Lo-Z, Hi-Z operation.Should have Frequency Response 20 Hz to 20 kHz ±0.5 dB at 1 W.Should have S/N Ratio >103 dBA, 20 Hz to 20 kHz.Should have THD+N <0.1% at 1 kHz.Should have protection against overheating, excessive input, overloaded speaker lines.Should be Energy Star certifiedShould automatically go on standby when no signal is detected.Should have 1x control/connection port to enable/disable standby mode.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 460 | Supply Installation testing commissioning of Digital Signal Processor with a minimum of 4 or more microphone/line inputs that include phantom power and AEC. It should also have 8 or more line outputs,The sampling rate should be 48kHz or better and the DSP should be expandable for port expansion. It should have a minimum of 64x64 Dante channels for digital audio transfer , DSP must support with electical features of THD+N (22Hz to 22kHz) : 0.002% (1kHz @ +4dBu); EIN : <125dBu, unweighted (20Hz to 20kHz); Dynamic Range : 110dB, unweighted; Propagation Delay 4ms; Crosstalk, input to input, 1kHz: <110dB; Phantom Power +48VDC up-to 100mA maximum;andcompliant to FCC Part 15 B and conform to CE and ICES-003:7 safety requirements.. The DSP should support control with an app via iOS and Android devices or any third-party control system. Additionally, it should have built-in filters, feedback suppression, and other necessary features as per specifications. |
| 461 | Supply Installation testing commissioning of USB 2.0 to Dante network endpoint, PoE-powered with single CatX cable and suitable for mounting under the table or behind a display, with UC mute sync. |
| 462 | 1) SITC of customizable video conference room solution for use with the MICROSOFT TEAM Rooms intelligent communications platform.2) It is preferrable to convert native Teams room to native Zoom room system if the platform of user changes.3) The collaboration hardware / codec provided should support Windows® 10 IoT Edition OS, 100/1000 Mbps Ethernet connectivity, minimum dual displays output and 10\" Tabletop touch screen.4) Tabletop Touch interface should be powered over ethernet for 24x7 use and which will be used for controlling the Microsoft Team calls and flexible room controls.5) This hardware should enable integration with your choice of displays, cameras, speakers, microphones, mixers, switchers, and audio-conferencing interface (or speaker phone)6) Engine should have 2 x output to be connected to 2 displays, 1 Input for sharing wired content during the call, USB 2.0 and 3.0 supported multiple ports foraccessories connectivity like camera, DSP, speakerphone etc.7) The touch screen offered with this package should be able to operate Microsoft Teams Room call Control features, also provide control of room lighting, shades, thermostats, and other equipment used in addition with the control system. It should also have USB-C port and USB-A port for BYOD / BYOM / USB Passthrough feature built in for users to use their own UC conference platform from laptop without rebooting the device.8) Package should be provided with necessary required cables, converters, POE, additional accessories, and components to be included to meet thesaid functionality.9) It should support IEEE 802.1X, SSL, TLS, SSH, SFTP (SSH File Transfer Protocol), password login, HTTPS secureprovisioning, IEEE 802.3at compliant.10) Should comply to CE, UL, FCC, ROHS. (Additional BIS to be shared if applicable)11) Should be Microsoft Teams certified Hardware. |
| 463 | Supply Installation Testing and commissioning of intelligent 20x PTZ Camera supporting minimum below parameters:1) Technology: Intelligent PTZ camera with visual AI for presenter Tracking Capability.2) Camera movement: Automatically pans, tilts, and zooms using dual camera technology3) Optical Zoom: Minimum 20x4) Image Sensor: Minimum 1/2.8 Sony CMOS Sensor.5) Focal Length: F=5.2-94 mm6) Video Format: Minimum 1080p607) Video Outputs: 3G-SDI, HDMI®, USB, ONVIF, RTSP, NDI8) Shutter Speed: 1/50-1/10,000 sec9) Illumination: 2 lux10) FOV Reference Camera: Horizontal: 104°11) FOV Main Camera: Horizontal: 56°12) Dual camera design: Wide angle reference camera & the PTZ Main camera13) Control: VISCA/TCP, VISCA/UDP, PELCO-D, PELCO-P, ONVIF14) Minimum 1x RS-485 port for controlling.15) Visibility Indicator: Should have bicolor LED, to show device activated and standby mode16) Reset: Hardware reset17) Presenter Tracking: Able to track group of presenters with option to add blocking zones (display, doors, glass openings etc) to avoid false tracking.18) Compliance: CE, FCC (BIS to be shared additionally, as applicable)Camera & Camera switching solution should be from one manufacturer only, to avoid any compatibility issue and meet the room functional as per requirement and user requirement. |
| 464 | Supply, Installation, Testing and commissioning of 4K60 4:4:4 8x8 HDMI matrix SwitcherShould have eight HDMI inputs and eight HDMI outputsShould have two stereo line-level audio output, to de-embedded audio from any of the eight HDMI inputsVideo Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsContent Protection: HDCP 2.3Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould be controllable via RS-232/RJ45 via external control system, Webbrowser supportCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 465 | Supply, Installation, Testing and commissioning of 2x1 Transmitter for HDMI Extension over CAT CableShould have two HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 466 | Supply, Installation, Testing and commissioning of Transmitter for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 467 | Supply, Installation, Testing and commissioning of Receiver for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI output and one HDBT Lite/RJ45 input.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 468 | Supply, Installation, Testing and commissioning of Transmitter and Receiver for HDMI, RS 232, and IR Signal Extension over CAT CableShould have one HDMI Input and one HDBT Lite/RJ45 output.Video Resolution: 4096x2160 @60 4:4:4, HDR10+, Dolby Vision video support.Audio Format: Dolby Digital®, Dolby Digital Plus, Dolby TrueHD, Dolby Atmos, DTS®, DTS 96/24, DTS HD High Res, DTS HD Master Audio, LPCM up to 8 channelsShould be able to transport 4096x2160 @60 4:4:4 resolution upto 130 ft (40 m) on HDBT Lite/RJ45 portContent Protection: HDCP 2.3Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have bidirectional RS 232 1xIR input port and 1x IR output port for pass-through.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 469 | Supply, Installation, Testing, and commissioning of HDMI to USB Converter.Should have one HDMI input, 1x analog audio input and one HDMI output with 1x parallel USB 3.0 outputResolution support: 4KShould have 1080p @ 60 fps uncompressed at USB for superior outputShould have USB Video Class (UVC) and USB Audio Class (UAC) standards, to work with video capture or streaming software available in marketsContent Protection: HDCP 2.2Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).USB powered |
| 470 | Supply, Installation, Testing and commissioning of AV Control System with control ports.Should have Quad Core processor / multicore CPU / Ultra-Fast processor, for faster processing and advanced automated system requirements.Should be able to control two rooms simultaneously, for future proof and backup purpose.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be JITC/FIPS/NIAP certified.Should have BACnet communication protocol, which allow integration with third-party building management systems (HVAC, security, and other systems) over Ethernet.Should have minimum 2 GB SDRAM and minimum 8 GB flash memoryShould have minimum, 6x IR/serial, 1x Bidirectional RS-422/485 port, 2x Bidirectional RS-232, 6x I/O, 8x low voltage relay.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaShould have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol), IPv4, IPv6.Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).Control processor & Touch Control interface should be from same OEM, and must not require any internet connectivity for configuration, programming and running.Should be shipped with license to control the room from PC/Laptop using UI. |
| 471 | Supply, Installation, Testing and commissioning of 4K wireless presentation and wireless collaboration device.User should be able to share content wirelessly using app, Google Chrome web browser, Miracast® screen mirroring technology for latest Windows, Mac, Android, and iOS mobile devices.User should be able to view minimum 2x wirelessly shared sources, side by side on a single screen and should work on last in first out (LIFO) sequence for content sharing.User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/Adapter supplied, for bring your own meeting experience.Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared.Should be able to configure with Microsoft Exchange Server (for Outlook® and Microsoft 365® software users), Google Calendar™, room scheduling software for room booking and meeting details to appear onscreenShould have I/O / RJ45 port for integration with room occupancy sensor to control room display based on room occupancy or vacancy.Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS to ensure IT policies compliance. And need to be configured and shown during installation.Should be supplied with 1x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software.Should have 1x HDMI Input, 1x HDMI Output, 1x stereo line-level audio output, 2x LAN port (to connect to Corporate, Guest network) and 2x USB port for peripherals connection.Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol).Should be able to control third party devices via 1x bi-directional RS-232, 1x IR, without the need to run control cable from any AV control system.Should be able to create its own Wi-Fi network, for guest users, for content sharing.Content Protection: HDCP 2.2Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). |
| 472 | Supply, Installation, Testing, and commissioning of cable cubby box to install into a table or horizontal surface for cable management.Should have retractable lid/top flap which opens and hides within the enclosure so that connectivity inside the chassis is visible from all the side of cable cubby. And when the lid is closed, it should have small pass-through which allows cables to be fully extended outside when used.Should have easy access to all the cables and power port, and all these must be clearly visible and on surface level, not in hollow blackholes, so that users do not have to get up from the chairs to find connectivity.Should be supplied with 2x Three pin Universal Power, 2x USBA Type ChargingShould be supplied with minimum 4 passthrough holes for AV cables.Should be TAA compliant / IC3S (Indian Common Criteria Certification) compliant / Common CriteriaCompliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable).All the required accessories to be included with the packageAdditional hardware can be used to meet the requirement |
| 473 | Supply Installation testing commissioning of 8x1G PoE+ AV Over IP SwitchSwitch having 1x1G and 1xSFP Managed AV Switch, Shall support Switching Fabric: 20 Gbps, Shall Support IGMP Support, Jumbo Frame Support and Fanless |
| 474 | Supply & Fixing of 17U Floor Stand 17U x 600W x 800D rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards- IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour - Combination of RAL 7037 (For frame) & RAL 7035 (For other parts) with fine texture, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Monitor Shelf etc. should be from same OEM as required |
| 475 | SITC of Cables, Connectors & Hardware - Cables Connectores, Converters, and necessary accessories to be considered additional for all the rooms to make it functional. |
| 476 | Approximate Dimension(L X WX H): 3000 x 1050 x 735, Side unit : 1800 x 600 x 585Supply and Installation of the main desk of approximate dimension(L X W X H): 3000 x 1050 x 735, Side unit : 1800 x 600 x 585 of main table in veneerfinish. Thetable shall be dividedinto twoparts, first the main table & second side unit with multiple drawers and shutters as per reference images. The table shall have Flip top panel detail as per the reference image. Monitor arm provision to be done. (Monitor arm to be paid separately in relevant tender item). The main table top shall be ofapproximate 75 mm thickness, comprising ofVeneer on top+BWP-IS710Gradeplyattopoftable+metalframing fabricatedaspertherequirement+BWP-IS710Gradeplyat bottom of the table with veneer finish + partial Leather insert on table top flushed with the adjacent veneer top.The Modesty panel shall be madeofIS710gradeplywithMetalliclaminate–satinfinish(of approved make & shade) with solid wood frame around as shown in referenceimagefixedtothetable.Thereshallbefabricatedmetal frame structure to support the table top, connecting to the peripheral leg/support. Additional metal support to be provided fixed to the table whereverrequiredfor stability. Shutters andDrawer fascia,all sides andbaseshallbemadeofIS710Gradeply+Veneerfinishand internalsofthestorageandinnershelvesshallbemadeofIS710 Grade ply + Laminate finish. Cable management incorporated within the furniture to conceal all cables starting from floor to all desks. Provisionforconnectivity,MultimediatoAV,Internet,laptoppower, extra power, and microphone to be provided as per requirement and ProvisionforFliptoppanel,grommet,Cabletray,andVertebrae Vertical Cable Manager shall be provided as per requirement including cap/cover.Minimum of2mm thicksolidteakwoodlipping on all visible/exposed ply edges shall be provided. 19 mm thick and 75 mm high teak wood skirting shall be provided on front/visible sides ofbaseasperreferenceimage.Allwoodenjoineryanddetailing shallbeasperthereferenceimages&datasheet.Allwoodenand veneer surfaces shall be finished with exterior grade water basePU polishofapprovedmake&shadeandhardwareofapprovedmake andfinishasmentionedindatasheet.The itemshallbefabricated as per datasheet, reference image and specification. Provisionforconnectivity,MultimediatoAV,Internet,laptoppower, extra power, and microphone to be provided as per requirement and ProvisionforFliptoppanel,grommet,Cabletray,andVertebrae Vertical Cable Manager shall be provided as per requirement including cap/cover.Minimum of2mm thicksolidteakwoodlipping on all visible/exposed ply edges shall be provided. 19 mm thick and 75 mm high teak wood skirting shall be provided on front/visible sides ofbaseasperreferenceimage.Allwoodenjoineryanddetailing shallbeasperthereferenceimages&datasheet.Allwoodenand veneer surfaces shall be finished with exterior grade water basePU polishofapprovedmake&shadeandhardwareofapprovedmake andfinishasmentionedindatasheet.The itemshallbefabricated as per datasheet, reference image and specification. Main Table :- 3000Wmm X 1050Dmm X 735mm H Side Table Size - 1800Wmm X 600Dmm X 585mm H |
| 477 | Back Storage of size: 2400Wx 400D x 2000Hmm |
| 478 | The chair shall have a seat made of medium-density foam on molded plywood, upholstered with fabric for comfort and durability. The backrest shall be designed with a fiberglass and nylon frame, covered with mesh for support and breathability. The armrests shall be adjustable and padded with PU for added comfort. The base shall be made of nylon and fitted with heavy-duty twin-wheel nylon castors for smooth mobility. The chair shall feature back tilt with single-position locking and a simple posture control mechanism, and the gas lift shall allow height adjustment to suit individual user requirements. |
| 479 | Visitor ChairApproximate Dimensions (LX W X H ): 560 x 582 X 880Supply and installation ofchair of approximate dimensions (LX WX H):560x582X880 madeofteakwoodarmsandlegswith exposed seat frame structure. The seat and back to be made from IS 710 Grade ply as per the approved design and pattern and are to be cushioned and upholstered. The chair back to have provision of pull handleinsolidwoodmember,foreasyhandlingofarmchair.Solid wood round tapering leg shall be provided with varied cross section . Forlining/upholsterywork,thestitchingworkshallbeasperthe approved design andpattern. Thehighdensitymoulded (polyurethane /Latex) foam shall be used in chair. Top layer shall be ofpolyester fibre 130 GSM to 150 GSM. The whole assembly to be coveredwith“Madarpat”andonittapestryofapprovedmakeand shade to be fixed as per reference intent / image. All wooden joinery anddetailingoftheunitshallbeasperthereferenceimagesand datasheet.Allwoodenandveneersurfacesshallbefinishedwith exterior grade water basePU polish of approved make & shade. |
| 480 | Supply and installation of a three seater sofa of approximate dimension(LXWXH):2100x785x810 madewithteakwood exposedframestructure.Thearm ,back&leg ofthesofashallbe madeofteakwoodwithhighqualityturnedwoodpatternasper referenceimages.Thewoodenframestructureshallhave“turned wood” pattern created by rotating a wood dowel on a “lathe” machine asperthementioned patterninteakwoodtobothsides,armsand back side of the seating unit. The seat & back frame structure to be made from teak wood. The seat, back and sides to be cushioned with upholstery work.Forlining/upholstery work,thestitchingworkshall beaspertheapproveddesignandpattern.SofaspringorMadras spring to be fixed on seat framing work. Ergonomic required density latexfoamandpolyurethanefoamshallbeusedinback,sideand seat of the unit. Top layer shall be of polyester fibre, in the seat, side and back of130 GSM to 150 GSM or as per required comfort level. The whole assembly to be covered with \"Madarpat\" and then tapestry ofapprovedmakeandshadetobefixed.Thelegsofthesofawill have circular sections of varied diameters and lengths as per approveddesignandtheseatshallhavepipingasperreference image. All wooden joinery and detailing of the unit shall be as per the referenceimagesanddatasheet.Allwoodenandveneersurfaces shall be finished with exterior grade water basePU polish of approved make & shade.3 seater sofa overall dimension - 1930mm W x 740mm D x 670mm H |
| 481 | 2 seater sofa overall dimension - 1450mm W x 740mm D x 670mm H |
| 482 | Center tableApproximate Dimension (L X W X H): 1100 x 550 x 380Supply and installation of the center table of approximate dimension (L X WX H): 1100 x 550 x 380 with table top of smoked toughened glassofthickness8mm, flushedwiththeadjacentwoodentopor fixed on the wooden member. The base shelf shall be made of teak woodwithribbedpatternasperthereferenceimage.Thecenter table shall be made of teak wood frame as per the approved design andpattern.Legsshallhaveverticalgroovesasperthereference image. All wooden joinery and detailing of the unit shall be as per the referenceimagesanddatasheet.Allwoodenandveneersurfaces shall be finished with exterior grade water basePU polish of approved make & shade. The hardware as per preferred make list in bid document and finish as per datasheet shall be provided. The item shallbefabricatedasperprovideddatasheet,referenceimageand specification. |
| 483 | Side tableApproximate Dimension (L X W X H): 600 x 600 x 610Supply and installation of the center table of approximate dimension (L X WX H): 600x 600x 610 with table top ofsmoked toughened glassofthickness8mm, flushedwiththeadjacentwoodentopor fixed on the wooden member. The base shelf shall be made of teak woodwithribbedpatternasperthereferenceimage.Thecenter table shall be made of teak wood frame as per the approved design andpattern.Legsshallhaveverticalgroovesasperthereference image. All wooden joinery and detailing of the unit shall be as per the referenceimagesanddatasheet.Allwoodenandveneersurfaces shall be finished with exterior grade water basePU polish of approved make & shade. The hardware as per preferred make list in bid document and finish as per datasheet shall be provided. The item shallbefabricatedasperprovideddatasheet,referenceimageand specification. |
| 484 | Supply and Installation of the conference tablewithtwo legsand provisionforconnectivity,MultimediatoAV,Internet,laptoppower, extra power, and microphone to be provided as per requirement and provision for Flip top panel, grommet, Cable tray, and Vertical Cable Managershallbeprovidedasperrequirementincludingcap/cover. Table top shall be approximate 75 mm thick comprising of laminate at top + IS 710 Grade ply at top of the table + metal framing fabricated of required size SHS/RHS metal box + IS 710 Grade ply + laminate finish at bottom of the table. Table top shall have minimum of 2 mm Solidteakwoodlippingacrosstheedgesasperthedetail.All external&internalshallbeLaminatefinishasperthereference image. Extra Support forthe Pop-upbox & Provision shall be made fortheelectrical/datawiringwithinthetabletop&legshallbe provided. Supporting framing for table & Vertical legs shall be fabricated in CRS steel, polished powder coated ofapproved make, shadeandqualityasperthereferenceimage.Additionalmetal support/leg to be provided to the table wherever required for stability. Adjustable leg leveler of approved make shall be used. Minimum of 2 mmthicksolidteakwoodlippingonallvisible/exposedplyedges shallbeprovided.Cablemanagementtobeincorporatedwithinthe furnituretoconcealallcablesstartingfromfloortoalldesks.All wooden joinery and detailing shall be as per the reference images & datasheet.Allwoodenandveneersurfacesshallbefinishedwith exterior grade water basePU polish of approved make & shade and hardwareofapprovedmake Meeting Table : 3200mm W x 1000mm D x 740mm H |
| 485 | Meeting Table : 2400mm W x 1000mm D x 740mm H |
| 486 | Supply and Installation of the conference tablewith multiple legs and provision for connectivity, Multimedia to AV, Internet, laptop power, extra power, and microphone to be provided as per requirementandprovisionforFliptoppanel,grommet,Cabletray, andVerticalCableManagershallbeprovidedasperrequirement includingcap/cover.Thetabletopshallbemadeofcomprisingof approximate 75 mm thick Veneer at top + IS 710 Grade ply at top of table + metal framing fabricated of required size SHS/RHS metal box+ IS 710 Grade ply at bottom of the table + veneer finish.Provision for the shutter shall be provided in vertical support.All external shall be Veneer finish including the table top and bottom as per the reference image and extra Support for the Pop-up box shall be provided as per requirement.Provisionshallbemadefortheelectrical/datawiring withinthetabletop&leg. Minimumof2mmthicksolidteakwood lippingonallvisible/exposedplyedgesshallbeprovided.Cable managementtobeincorporatedwithinthefurnituretoconcealall cables starting from floor to all desks. All wooden joinery and detailingshallbeasperthereferenceimages&datasheet.All woodenandveneersurfacesshallbefinishedwithexteriorgrade waterbase PUpolishofapprovedmake&shadeandhardwareof approved make and finish as mentioned in datasheet.Meeting Table : 8500mm W x 2000mm D x 740mm H |
| 487 | Meeting Table : 5000mm W x 2000mm D x 740mm H |
| 488 | Meeting Table : 3750mm W x 1800mm D x 740mm H |
| 489 | Providing HIGH back revolving chairs forof where Chair seat made up of insert moulded Polyurethane Foam upholstered with foam laminated mesh fabric, insert moulded foam assembled over a load bearing plastic seat cover, back shall be made up of two piece injection moulded frame, inner frameupholstered with mesh fabric and mounted on the main assembly , back adjustable lumbar support for achieving comfortable seating posture.Armrests should be adjustable with 120-160 mm adjustability with PU padded. Base: Black nylon base with 5 nos. nylon castors.Chair should be of 360 degree swivel Posture Control with multiple locking and synchro mechanism and hydraulic gas lift gas lift to allows 90-100 mm. of height adjustment.The Seat width of 530-550 mm Seat Height of 420-510mm with hydraulic height adjustability of 90-100mm. Sub assembly back size 550 - 620 mm height. Effective back height from Seat - 570mm, polyurethane foam for seat having density65-70 kg/m3. Pedestal made of nylon base fitted with 5 nos. twin wheel castors (castor wheel dia. 60-70 cm), base pedestal dia60-70 mm and pitch center dia. 700-720mm with castors, twin wheel castors injection moulded in Nylon etc. all complete as per direction of Engineer-in-Charge.Product should be BIFMA gold rated SCSglobal certified for inhouse air quality . |
| 490 | Providing medium back revolving chairs. Chair seat made up of insert moulded Polyurethane Foam upholstered with foam laminated mesh fabric, insert moulded foam assembled over a load bearing plastic seat cover, back is made up of two piece injection moulded frame, inner frameupholstered with mesh fabric and mounted on the main assembly, backadjustable lumbar support for achieving comfortable seating posture.Armrests should be adjustable with 120-160 mm adjustability with PU padded.Base: Black nylon base with 5 nos. nylon castors.Chair should be of 360 degree swivel Posture Control with multi pointer locking and synchro tilt mechanism and hydraulic gas lift gas lift to allows 90-100 mm. of height adjustment. Seat size 440 - 550 mm depth, Seat width of 530-550 mm Seat Height of 420-510mm with hydraulic height adjustability of 90-100mm. Sub assembly back size 550 - 620 mm height. Effective back height from Seat - 570mm, polyurethane foam for seat having density65-70 kg/m3. Pedestal made of nylon base fitted with 5 nos. twin wheel castors (castor wheel dia. 60-70 cm), base pedestal dia60-70 mm and pitch center dia. 700-720mm with castors, twin wheel castors injection moulded in Nylon etc. all complete as per manufacturers specification, approved sample and direction of Engineer-in-Charge. Product should be BIFMA gold rated SCSglobal certified for inhouse air quality . |
| 491 | Supply and installation of the main desk table in one cluster of approximate dimensionThe main table shall have Flip top panel detail as per the reference image. The main table top shall be approximately 35mm thick made of IS 710 Grade ply + veneer on top. The side storage unit shall have multiple drawers & open space made of IS 710 Grade ply + Veneer finish as per data sheet & side storage one side shall be made of IS 710 Grade ply + Laminate finish as shown in the reference image. All external surfaces shall be veneer finish & internal surfaces shall be laminate finish of approved make and shade and the supporting framing for table & vertical legs shall be fabricated in CRS steel, polished powder coated of approved make, shade and quality as per the reference image. The Modesty panel shall be made of IS 710 grade ply with Metallic laminate – satin finish (of approved make & shade) with solid wood frame around as shown in reference image fixed to the table. Drawer fascia shall be made of IS 710 Grade ply + veneer finish and all the other sides and base of the drawer shall be made of IS 710 Grade ply + laminate finish. Additional metal support to be provided to the table wherever required for stability. Cable management incorporated within the furniture to conceal all cables starting from floor to all desks. Provision for connectivity, Multimedia to AV, Internet, laptop power, extra power, and microphone to be provided as per requirement including cap/cover. Provision for Flip top panel, grommet, Cable tray, and Vertebrae Vertical Cable Manager shall be provided as per requirement including cap/cover. Minimum of 2 mm thick solid teak wood lipping on all visible/exposed ply edges shall be provided. 19 mm thick and 75 mm high teak wood skirting shall be provided on front/visible sides of base as per reference imageTable Size : 1500mm W x 800mm D x 740mm H |
| 492 | Supply and installation of the main desk tableThe main table shall have Flip top panel detail as per the reference image. The main table top shall be approximately 35mm thick made of IS 710 Grade ply + veneer on top. The side storage unit shall have multiple drawers & open space made of IS 710 Grade ply + Veneer finish as per data sheet & side storage one side shall be made of IS 710 Grade ply + Laminate finish as shown in the reference image. All external surfaces shall be veneer finish & internal surfaces shall be laminate finish of approved make and shade and the supporting framing for table & vertical legs shall be fabricated in CRS steel, polished powder coated of approved make, shade and quality as per the reference image. The Modesty panel shall be made of IS 710 grade ply with Metallic laminate – satin finish (of approved make & shade) with solid wood frame around as shown in reference image fixed to the table. Drawer fascia shall be made of IS 710 Grade ply + veneer finish and all the other sides and base of the drawer shall be made of IS 710 Grade ply + laminate finish. Additional metal support to be provided to the table wherever required for stability. Cable management incorporated within the furniture to conceal all cables starting from floor to all desks. Provision for connectivity, Multimedia to AV, Internet, laptop power, extra power, and microphone to be provided as per requirement including cap/cover. Provision for Flip top panel, grommet, Cable tray, and Vertebrae Vertical Cable Manager shall be provided as per requirement including cap/cover.Minimum of 2 mm thick solid teak wood lipping on all visible/exposed ply edges shall be provided. 19 mm thick and 75 mm high teak wood skirting shall be provided on front/visible sides of base as per reference image. All wooden joinery and detailing shall be as perthe reference images & datasheet. All wooden and veneer surfaces shall be finished with exterior grade water base PU polish of approved make & shade and hardware of approved make and finish as mentioned in datasheet. The item shall be fabricated as per datasheet, reference image and specification.Main table:1500x660x710 with Side unit: 900 x 450 x 585mm |
| 493 | The chair shall have a seat made of medium-density foam on molded plywood, upholstered with fabric for comfort and durability. The backrest shall be designed with a fiberglass and nylon frame, covered with mesh for support and breathability. The armrests shall be adjustable and padded with PU for added comfort. The base shall be made of nylon and fitted with heavy-duty twin-wheel nylon castors for smooth mobility. The chair shall feature back tilt with single-position locking and a simple posture control mechanism, and the gas lift shall allow height adjustment to suit individual user requirements. |
| 494 | Visitor ChairApproximate Dimensions (LX W X H ): 560 x 582 X 880Supply and installation ofchair of approximate dimensions (LX WX H):560x582X880 madeofteakwoodarmsandlegswith exposed seat frame structure. The seat and back to be made from IS 710 Grade ply as per the approved design and pattern and are to be cushioned and upholstered. The chair back to have provision of pull handleinsolidwoodmember,foreasyhandlingofarmchair.Solid wood round tapering leg shall be provided with varied cross section . Forlining/upholsterywork,thestitchingworkshallbeasperthe approved design andpattern. Thehighdensitymoulded (polyurethane /Latex) foam shall be used in chair. Top layer shall be ofpolyester fibre 130 GSM to 150 GSM. The whole assembly to be coveredwith“Madarpat”andonittapestryofapprovedmakeand shade to be fixed as per reference intent / image. All wooden joinery anddetailingoftheunitshallbeasperthereferenceimagesand datasheet.Allwoodenandveneersurfacesshallbefinishedwith exterior grade water basePU polish of approved make & shade. |
| 495 | Supply and installation ofthe workstation desk table.The single unit shall be installed in clusters as per theGFC drawings. The table shall have Flip top panel detail anddeskorganiser +dividerscreen foreachdeskasperthe reference image. Provision to be done for Monitor arm. (Monitor arm tobepaidseparatelyinrelevanttenderitem).Themaintabletop shallbeapproximately 27mmthickmadeofIS710Gradeply+ laminateontop +solidteakwoodlippingasperthereference image. Supporting framing for table & the vertical legs shall be made of CRS steel. The unit shall have table divider fixed on the top of the table as per the reference images shall be made of 8 mm thick extra clearbackpaintedglassfinish.Themodestypanelwithcabletray shall be made up of 1.5mm thick metal, supported and fixed to metal structure and cover with vertical riser to uptake wiring.All metal work shallbefinishedwithepoxypolyesterpowdercoatingofapproved color&shade.Additionalmetalsupporttobeprovidedtothetable whereverrequiredforstability. Cablemanagementtobe incorporatedwithinthefurnituretoconcealallcablesstartingfrom floor to all desks.Provision for connectivity,Multimedia to AV, Internet,laptoppower,extrapower, andmicrophone tobeprovided as per requirement and Provision for Flip top panel, grommet, Cable tray, and Vertebrae Vertical Cable Manager shall be provided as per requirementincludingcap/cover.Minimumof2mmthicksolidteak woodlippingonallvisible/exposedplyedgesshallbeprovided. Rectangular Workstation of size:- 1200mm (W) x 600mm (D) x 740mm(Worktop Height) x 1180-1220 mm (Height of panel from Ground) for each person. |
| 496 | Frame Work, Partition and Cable management : Frame work shall consist of main spine and return spine of aluminium extruded section of minimum thickness of 1.2 mm. The overall thinkness of Panel base System should be minimum 60-70 mm. The thickness of main spine partition panel should be minimum 60-70 mm & minimum 25-28mm/60 mm thick for returnspine. The panel will be hollow inside to accommodate wiring for electrical/data and outer frame of panel should be made of extruded aluminium.The panel shall be made up of 3 mm thick MDF both sides of the wooden frame to create the hollow for the wire management. The panel outer aluminium frame is designed in such a way that it can be easily slide in to the columns/ Connectors by means of stacking one over the other. Horizontal race way should be 150-170 mm height aluminium profile. There shall be complete cable management arrangement with openable raceway above/ below worktop with provision for fitting electrical/data switches and holes for passing cable.Panel Finishes : Finishes of panel above the worktop can be fabric pinup/fabric/laminate + Glass/metal writable markerboard or single finish tile with raceway on main spine. Finishes of main spine panel below the worktop the hollow panel should be made of MDF tile and 0.5mm thick steel sheet pasted on MDF which is powder coated with EPC finish 80-90 microns for durability on the inside as well on the outside. Raceway can be provided above/below the worktop.Connectors/ Brackets: End Post: Aluminium 60-70 mm width – 1180-1220 mm height.Two way post: Aluminium 30-70 mm width –1180-1220 mm height., Three way post: Aluminium 30-70 mm width –1180-1220 mm height., Four way post: Aluminium 30-70 mm width – 1180-1220 mm height., Brackets: Table top supported with 50-60mm width steel bracket., Table top to table top connector: 150-170 mm Width x 120-140 mm Depth width connector.Worktop & legs :Worktop Made of 25mm thick E-1 grade particle board finished with 2mm ABS edge banding. E1 grade laminate with zero urea formaldehyde emissions ( |
| 497 | Seat & Back : Seat & Back of the chair shall beSolid high density machine injected foam withMS structure inside the foam and covered withfabric of approved finish and approved colour.Base - Wooden legs/metal/chrome . |
| 498 | The chair shall have a seat made of medium-density foam on molded plywood, upholstered with fabric for comfort and durability. The backrest shall be designed with a fiberglass and nylon frame, covered with mesh for support and breathability. The armrests shall be adjustable and padded with PU for added comfort. The base shall be made of nylon and fitted with heavy-duty twin-wheel nylon castors for smooth mobility. The chair shall feature back tilt with single-position locking and a simple posture control mechanism, and the gas lift shall allow height adjustment to suit individual user requirements. |
| 499 | Supply and Installation of three seater sofa of approximate dimension (L X W X H): 2100 x 780 x 890 with handles, legs and base shall be in exposed solid teak wood and fully upholstered seat base and back asperreferenceimage.Bothfixedhandles,base,legsandback shallbemadeupfromsolidteakwood&shallhaveremovable covers. Welt / trim detail all along the wood frame shall be provided. Thestitchingworkforlining/upholsteryworkshallbeasperthe approveddesignandpattern.Sofaspringormadrasspringtobe fixed on frame work. Ergonomic required density latex foam & polyurethanefoamshallbeusedinbackandseatoftheunit.Top layershallbeofpolyesterfiber130GSMto150GSMorasper required comfort level. The whole assembly to be covered in “Madarpat” and tapestry of approved make and shade to be fixed on it.Stiffenerortiememberneedtoplacewithoutcompromisingthe originaldesignandensurethestability&strengthofthesame. All wooden joinery and detailing of the unit shall be as per the reference imagesanddatasheet.Allwoodenandveneersurfacesshallbe finished with exterior grade water basePU polish of approved make &shade.Thehardwareasperpreferredmakelistinbiddocument andfinishasperdatasheetshallbeprovided. 3 seater sofa overall dimension - 1860mm W x800mm D x 695mm H, Seating Height 430mm |
| 500 | 2 seater sofa overall dimension - 1460mm W x800mm D x 695mm H, Seating Height 430mm |
| 501 | Supply and installation of the center/ corner table with table top of smoked toughened glassofthickness8mm, flushedwiththeadjacentwoodentopor fixed on the wooden member. The base shelf shall be made of teak woodwithribbedpatternasperthereferenceimage.Thecenter table shall be made of teak wood frame as per the approved design andpattern.Legsshallhaveverticalgroovesasperthereference image. All wooden joinery and detailing of the unit shall be as per the referenceimagesanddatasheet.Allwoodenandveneersurfaces shall be finished with exterior grade water basePU polish of approved make & shade. The hardware as per preferred make list in bid document and finish as per datasheet shall be provided. The item shallbefabricatedasperprovideddatasheet,referenceimageand specification.Centre table Size - 1200mm W x 600mm D x 365mm H |
| 502 | Side table Size - 600mm W x 600mm D x 365mm H |
| 503 | The reception desk must be provided and placed according to the following detailed specifications:Top and Legs: The desk top and legs will be constructed from 36mm thick E1 grade laminate, finished with 2mm thick PVC edge banding and a melamine finish. The grain pattern of the table top will be unidirectional for a consistent and aesthetically pleasing appearance.Front Panel: The front hanging panel will be made from 18mm thick decorative E1 grade board, ensuring a high-quality and visually appealing finish.Drawer Unit: The reception desk will include a drawer unit with three drawers (Box+Box+File) in a melamine finish. The pedestal will have overall dimensions of 420mm in width, 450mm in depth, and 600mm in height. The drawer bodies will be constructed from E1 grade laminate. The exposed edges of the worktop will be secured with 2mm thick PVC edge banding tape in an approved color.Material and Environmental Compliance: The E1 grade laminate used must ensure zero urea formaldehyde emissions, with formaldehyde levels not exceeding 8mg/100g of oven-dry board, measured by the perforated method. This laminate must comply with EN 120-1992 standards.Certification and Warranty: The reception desk should be BIFMA Gold rated and SCS Global certified for indoor air quality, ensuring adherence to high safety and environmental standards. Additionally, the product must come with a five-year warranty to guarantee its quality and durability.Approval: The desk must be sourced from an approved manufacturer and installed as per the specifications and images provided, under the guidance and approval of the project architect, consultant, and engineer in charge.These specifications ensure that the reception desk is not only functional and stylish but also meets high standards for environmental quality and durability.Reception Counter of size: 1800W1 x 750D1/550D2 x1100/740Hmm |
| 504 | Reception Counter of size: 3000W1 x 750D1/550D2 x1100/740Hmm |
| 505 | Working Desk with side unit Supply and installation of a tableThemaintableshallhaveFliptoppanel detailasperthereferenceimage.Themaintabletopshallbe approximately35mmthickmadeofIS710Gradeply+Veneeron top. The side storage unit shall have drawers, shutter & open space fortheprintermadeofIS710Gradeply+Veneerfinishasper datasheet. The side storage top & one side shall be made of IS 710 Gradeply+Laminatefinishasshowninthereferenceimage.All externalsurfacesshallbeveneerfinish&internalsurfacesshallbe laminatefinishofapprovedmakeandshadeandthesupporting framingfortable&VerticallegsshallbefabricatedinCRSsteel, polished powder coated of approved make, shade and quality as per thereferenceimage.TheModestypanelshallbemadeofIS710 gradeply withMetalliclaminate–satinfinish(ofapprovedmake& shade)withsolidwoodframeasshowninreference imagefixedto the table. Additional metalsupport to be provided to the table wherever required for stability. Drawer fascia shall be made of IS 710 Gradeply+Veneerfinishandalltheothersidesandbaseofthe drawershall bemadeofIS 710Grade ply + Laminatefinish. Cable managementincorporatedwithinthefurnituretoconcealallcables starting from floor to all desks. Provision for connectivity, Multimedia toAV,Internet,laptoppower,extrapower,andmicrophonetobe providedasperrequirementincludingcap/cover.ProvisionforFlip top panel, grommet, Cable tray, and Vertebrae Vertical Cable Managershallbeprovidedasperrequirementincludingcap/cover. Minimum of 2 mm thick solid teak wood lipping on all visible/exposed ply edges shall be provided. 19 mm thick and 75 mm high teak wood skirting shall be provided on front/visible sides of base as per reference image.All wooden joinery and detailing shall be as per the StorageSupply and installation of the storage unit of approximate dimensions (L X W X H): 1800 x 450 x 735, shall have multiple shutters with two divisions. Adjustable shelves inside the unit shall be provided. Storageunit shall bemadeofply +laminate +veneer finishas per thereferenceimage.Theshutters andinner shelvesshallbemade from ply + laminate finish on both the faces with teak wood lipping all around as per the reference image. The backing of storage shall be made from ply. All external side of the box work (sides and top only) shallbeveneerfinish&internalsurfaces shall belaminatefinishof approvedmakeandshade.Allstorageshallhavesufficientgapat back/sidefortheelectrical/datawireforswitchboardandlightas required. Minimum of 2 mm thick solid teak wood lipping on all visible/ exposed ply edgesshall beprovided. 19mm thickand 75mm high teak wood skirting shall be provided on front /visible sides of base as per reference image. All wooden joinery and detailing of the unit shall beasperthereferenceimagesanddatasheet.Allwoodenand veneer surfaces shall be finished with exterior grade water basePU polishofapprovedmake&shade.Thehardwareasperpreferred makelistinbiddocumentandfinishasperdatasheetshallbe provided.Theitemshallbefabricatedasperprovideddatasheet, reference image and specification. Front elevation area of unit shall be measured for payment.Main Table :- 2500Wmm X 1050Dmm X 740mm H Side Table Size - 1200Wmm X 500Dmm X 740mm H |
| 506 | Back Storage of size: 2100Wx 400D x 2000Hmm |
| 507 | Supply and installation of two seater sofa made out of superior class teak wood having exposed frame structure, Solid wood arms,back and legs with exposed seat frame and cushioned. Loose cushions upholstery on seat and back (both sides). Fixed upholstery on seat and back. The seat shall be made of polyurethane foam required layer with polyester fibre as per required comfort level. The whole assembly to be covered“Madarpat” and onit tapestry of approvedmake and shadeto be fixed.The lining /upholstery workwith fabricas perselection. Turnedwood Leg withmouldingpattern.Welt/trimdetailall alongthewoodframe.Thesolidwoodround Tapering legs will have two mould-ing rings. Edges with upholstery connection to have piping. Wooden frame for side edge of arm rest +Backrest to be as per approved design.All wooden surface shall be finished with exterior grade water basePU polish of approved make & shade. Hardware of approved make and finish shall be provided as specified.Furniture item shall be fabricated as per provided datasheet, intent image and specification.3 seater sofa overall dimension - 2050mm W x 760-780mm D x 680-700mm H |
| 508 | 2 seater sofa overall dimension - 1550mm W x 760-780mm D x 680-700mm H |
| 509 | 1 seater sofa overall dimension - 810mm W x 760-780mm D x 680-700mm H |
| 510 | The chair shall have a seat made of medium-density foam on molded plywood, upholstered with fabric for comfort and durability. The backrest shall be designed with a fiberglass and nylon frame, covered with mesh for support and breathability. The armrests shall be adjustable and padded with PU for added comfort. The base shall be made of nylon and fitted with heavy-duty twin-wheel nylon castors for smooth mobility. The chair shall feature back tilt with single-position locking and a simple posture control mechanism, and the gas lift shall allow height adjustment to suit individual user requirements. |
| 511 | Visitor ChairApproximate Dimensions (LX W X H ): 560 x 582 X 880Supply and installation ofchair of approximate dimensions (LX WX H):560x582X880 madeofteakwoodarmsandlegswith exposed seat frame structure. The seat and back to be made from IS 710 Grade ply as per the approved design and pattern and are to be cushioned and upholstered. The chair back to have provision of pull handleinsolidwoodmember,foreasyhandlingofarmchair.Solid wood round tapering leg shall be provided with varied cross section . Forlining/upholsterywork,thestitchingworkshallbeasperthe approved design andpattern. Thehighdensitymoulded (polyurethane /Latex) foam shall be used in chair. Top layer shall be ofpolyester fibre 130 GSM to 150 GSM. The whole assembly to be coveredwith“Madarpat”andonittapestryofapprovedmakeand shade to be fixed as per reference intent / image. All wooden joinery anddetailingoftheunitshallbeasperthereferenceimagesand datasheet.Allwoodenandveneersurfacesshallbefinishedwith exterior grade water basePU polish of approved make & shade. |
| 512 | Supply and Installation of the table The main table & side unit with drawers asper thereference images. The table shall have Fliptoppaneldetailasperthereferenceimage.MainTabletopof approximate thickness 35mm shall bemadeofIS710 Gradeply + laminateontop asper thereference image.All externalsurfaces & internalsurfacesshallbelaminatefinishofapprovedmakeand shade.Supportingframingfortable&VerticallegsshallbeCRS steel, polished powder coated of approvedmake, shade and quality asperthereferenceimage.TheModesty panelshallbe18Gauge Perforated metallic sheet – EpoxyPolyesterpowdercoating(of approved make & shade) with solid wood frame around the modesty panel fixed to the table. Additional metal support to be provided fixed tothetablewhereverrequiredforstability.Drawerfasciashallbe made of IS 710 Grade ply + Veneer finish and all the other sides and baseofthedrawershallbemadeofIS710Gradeply+Laminate finish. Cable management incorporated within the furniture to conceal all cables starting from floor to all desks.Provisionforconnectivity,MultimediatoAV,Internet,laptoppower, extrapower,andmicrophonetobeprovidedasperrequirement includingcap/cover.ProvisionforFliptoppanel,grommet,Cable tray, and Vertebrae Vertical Cable Manager shall be provided as per requirementincludingcap/cover.Minimumof2mmthicksolidteak woodlippingonallvisible/exposedplyedgesshallbeprovided.19 mmthickand75mmhighteakwoodskirtingshallbeprovidedon front/visible sides of base as per reference image. All wooden joinery anddetailingshallbeasperthereferenceimages&datasheet.All woodenandveneersurfacesshallbefinishedwithexteriorgrade waterbase PUpolishofapprovedmake&shadeandhardwareof approved make and finish as mentioned in datasheet. Main Table :- 3500Wmm X 1050Dmm X 740mm H Side Table Size - 1200Wmm X 500Dmm X 740mm H |
| 513 | Main Table :- 2700Wmm X 1050Dmm X 740mm H Side Table Size - 1200Wmm X 500Dmm X 740mm H |
| 514 | Main Table :- 2500Wmm X 1050Dmm X 740mm H Side Table Size - 1200Wmm X 500Dmm X 740mm H |
| 515 | Supply and Installation of the main desk table thta is divided into two parts, first the main table & second side unit with multiple drawers as per reference images. The table shall have Flip top panel detail as per the reference image. Monitor arm provision to be done. (Monitor arm to be paid separately in relevant tender item.)The main table top of approximately thickness 35 mm shall bemade of IS 710 Grade ply + veneer on top & bottom + partial Leather insert on table top flushed with the adjacent veneer top. The side storage unit shall have multiple drawers made of IS 710 Grade ply+ veneer as per the approved pattern & design. The table top comprising of 4 mm Veneer on top + BWP - IS 710 Grade ply at top oftable + metal framing fabricated as per the requirement+BWP - IS710 Grade ply table bottom with veneer finish. The Modesty panel shall be made of IS 710 grade ply with Metallic laminate – satin finish (of approved make & shade) with solid wood frame around as shown in reference image fixed to the table. Drawer fascia shall be made of IS 710 Grade ply + Veneer finish and all the other sides and base of the drawer shall be made of IS 710 Grade ply + Laminate finish. supporting framing for table & Vertical legs shall be fabricated in CRS steel, polished powder coated of approved make, shade and quality as per the reference image. Additional metal support to be provided to the table wherever required for stability. Cable management incorporated within the furniture to conceal all cables starting from floor to all desks.Main Table :- 2100Wmm X 900Dmm X 740mm H Side Table Size - 1100Wmm X 500Dmm X 740mm H |
| 516 | Main Table :- 1500Wmm X 750Dmm X 740mm H Side Table Size - 1100Wmm X 500Dmm X 740mm H |
| 517 | The chair shall have a seat made of medium-density foam on molded plywood, upholstered with fabric for comfort and durability. The backrest shall be designed with a fiberglass and nylon frame, covered with mesh for support and breathability. The armrests shall be adjustable and padded with PU for added comfort. The base shall be made of nylon and fitted with heavy-duty twin-wheel nylon castors for smooth mobility. The chair shall feature back tilt with single-position locking and a simple posture control mechanism, and the gas lift shall allow height adjustment to suit individual user requirements. |
| 518 | Visitor ChairApproximate Dimensions (LX W X H ): 560 x 582 X 880Supply and installation ofchair of approximate dimensions (LX WX H):560x582X880 madeofteakwoodarmsandlegswith exposed seat frame structure. The seat and back to be made from IS 710 Grade ply as per the approved design and pattern and are to be cushioned and upholstered. The chair back to have provision of pull handleinsolidwoodmember,foreasyhandlingofarmchair.Solid wood round tapering leg shall be provided with varied cross section . Forlining/upholsterywork,thestitchingworkshallbeasperthe approved design andpattern. Thehighdensitymoulded (polyurethane /Latex) foam shall be used in chair. Top layer shall be ofpolyester fibre 130 GSM to 150 GSM. The whole assembly to be coveredwith“Madarpat”andonittapestryofapprovedmakeand shade to be fixed as per reference intent / image. All wooden joinery anddetailingoftheunitshallbeasperthereferenceimagesand datasheet.Allwoodenandveneersurfacesshallbefinishedwith exterior grade water basePU polish of approved make & shade. |
| 519 | Supply and Installation of the conference table with two legs and provision for connectivity, Multimedia to AV, Internet, laptop power, extra power, and microphone to be provided as per requirement and provision for Flip top panel, grommet, Cable tray, and Vertical Cable Manager shall be provided as per requirement including cap/cover. Table top shall be approximate 75mm thick comprising of veneer at top + IS 710 Grade ply at top of the table + metal framing fabricated of required size SHS/RHS metal box + IS 710 Grade ply + veneer at table bottom. All external shall be Veneer finish including the table top and bottom as per the reference image. The Box work and Vertical support shall be made from IS 710 Grade ply + Veneer finish and extra Support for the Pop-up box shall be provided as per requirement. Provision shall be made for the electrical /data wiring within the table top & leg. Minimum of 2 mm thick solid teak wood lipping on all visible/exposed ply edges shall be provided. Cable management to be incorporated within the furniture to conceal all cables starting from floor to all desks. All wooden joinery and detailing shall be as per the reference images & datasheet. All wooden and veneer surfaces shall be finished with exterior grade water base PU polish of approved make & shade and hardware of approved make and finish as mentioned in datasheet. The item shall be fabricated as per datasheet, reference image and specification.Meeting Table : 1800mm W x 900mm D x 740mm H |
| 520 | Providing & Placing Cabin office Table with side unit with following details and specifications : Top and legs are made of 25mm thick Particle Board (E-1 Grade), melamine finish with matching 2mm PVC edge-banding. The Modesty is Particle board wood Grade E-1 (Environmental Friendly) thickness 18 mm cover with Melamine Edge-Banding 2 mm PVC Lipping. The return top is made of 25mm thick Particle Board (E-1 Grade), melamine finish with 2 mm PVC edge-banding. Drawer Unit : 3 drawer Metal pedestal of overall dimensions internal and external dimensions 380-430 mm (W) x 430-480 mm (D) x 600-620 mm ( H). Drawer body should be made of CRCA of thickness 0.7-0.8 mm duly powder coated with 70-80 micron. Each pedestal should have 5 Nos castor fitted to it where in one castor will be fitted to lower most drawer to provide extra stability.Wire management: Completely concealed wiremanagement with Aluminium anodized flipper with soft closure, wiring tray & beams Made from MS sheet 2 mm., flange structure epoxy powder 70-80 micron coated spray color, baked at temperature 200c with vertical wire uptake from floor via middle leg having removable cover. Wire seperator for data provided in cable tray below fipper.E1 Grade laminate to be used which provide no urea formaldehyde emission and formaldehyde should be phenol base with emission of not more than ( |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail