| 1 | Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articlescomplete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed by Engineer-in-Charge. |
| 3 | Dismantling floor, hearth or wall tiling including cementmortar beddingremoving serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 etc: complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for Rendering 10 mm thk in CM (1:4) as in backing coat of cement plaster for laying of wall tiles etc: complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F Non Skid (coloured) ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etccomplete all as specifed and as directed by Engineer-in-Charge. |
| 7 | M&L for Glazed (Coloured) ceramic tiles in vertical surfaces 300 x 450 x 8 to 9 mm/ 450 x 350 x 8 to 9 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchetccomplete all as specified and as directed by Engineer-in-Charge. |
| 8 | Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for kitchen platform jointed and set in CM 1:3 Over a screed bed of 15mm and fixed including rounding to edge of stone slabs one side edgeetc complete all as specified and as directed by Engineer-in-Charge |
| 10 | M&L for machine cut granite 18 to 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like laid over & including15mm thick bedding /backing coat in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of slab complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Rounding and moulding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Taking down existing doors/windows/ventilators frame with shutters ( without taking off shutters from the frame ) not exceeding 1.5 Sqm each complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for powder coated aluminium three track, three shutter (of equal width) sliding type window without sash bar includingnecessary jointing clip, rubber packing, neoprene rubber gasket, locking arrangement (star lock) bearing(two no\"s for each sliding shutter ) &4 mm thick plain glass for glazing with for two shutters andaluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire stapless complete all as specified and directed by Engineer-in-Charge for one shutter & including following powder coated section as given in \"JINDAL\" catalouge complete all as specified and as directed by Engineer-in-Charge(i) Frame (Bottom) -20620, (ii) Frame top & Side - 20621, (iii) Shutter Vertical (Handle Lock) - 20846, (iv) Shutter Vertical -(int lock) - 20845, (v) Shutter (Top) - 20844, (shutter Bottom) - 20847 |
| 14 | S&F aluminium ventilatorlouvered type without sash bar section as per designation 63400 of IS 737 approved by GE( minium 15 micron anodised) includingnecessary jointing clip, rubber packing,including necessary locking arrangement , anodised snap beading screws and 4mm thick pin headed glass etc complete |
| 15 | S&F in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittingswith long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed by Engineer-in-Charge. |
| 16 | S&F in repairs fancy Pillar taps(15mm), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot\" or \"Cold\" with long screwed shanks and fly-nuts,screwed for iron pipe and fixed |
| 17 | S/F low density polyethene pipes (LDPE) 40mm of pressure rating 6 Kg/cm2 fixedcomplete to walls, ceiling or laid in floors etc, complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F in repairs Bib taps, fancy type, chromium platedwith crutchsc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 19 | S&F in repairs Stop valves, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch , screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 20 | S&F in repairs Angle cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 21 | S&F in repair PVC connections, 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F in repair soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F in repairs 600 X 450mm bevelled edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs to wall with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceilingwith all clampsin Shafts/ducts with all necessary scaffolding to fix the pipes andtesting the joints under prescribed pressure etccompleteall as specified and as directed by Engineer-in-Charge. |
| 26 | Taking up or down steel tubing and connections, 15 mm bore including cleaning for re-fixing or removal to store |
| 27 | Supplying and laying of CPVC pipes SDR 11 16 mm & Plain CPVC SDR 11 fittings on walls/ceiling or laying and conceiling it in floors/walls complete all as specified. |
| 28 | Cutting chases, pinning in.in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth. |
| 29 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Taking down cement or cement lime plaster on brick masonary or concrete surface in wall and ceiling etc including raking out joints, hacking for keys, scrubbing down with water etc and removing rubbish outside MD land etc complete all as specified and directed by Engineer-in-Charge. |
| 31 | M/L for rendering 10 mm thick in CM 1:6 on brick walls finishing with sagoleven and smooth (with out using extra cement)etc complete all as specified and directed by Engineer-in-Charge. |
| 32 | M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surface even and smooth with sagol including taking down and removing debris outside MD land etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in repair aluminium powder coated (fancy type) tubular curtain rod, 20mm dia, complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F in repair bracket aluminium powder coated (fancy type) for 20 mm dia tubular curtain rod(for item above) complete all as specified and as directed by Engineer-in-Charge |
| 35 | S&F in repairs 1000 ltrs Rotational mould polyethylene waterstorage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I with float valve and gate valve,Tank nipple and all other fittings complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe290 Gde E-165 ,complete all as directed by Engineer-in-Charge |
| 37 | M&L for Preparing newely/Old plastered surface and primng with alkali resistant priming paint and applying 2 coats of oil bound distemper on walls over 3 mm thk wall care putty |
| 38 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 39 | M&L for preparation of old painted wood surfaces of any description having width/girth execeeding 10cm and apply two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for preparation of new steel surfaces, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of anti-corrosive epoxy(poly Urethane based)over a coat of epoxy primer of approved make completeall as specified and directed by Engineer-in-Charge. |
| 41 | Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosiac wherever occurs over roof and chhajja surfaces scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m n.exc. 2000m etc complete all as specified and directed by Engineer-in-Charge. |
| 42 | M/L for rendering 10mm thick in cm 1:4 on concrete roof and chajja surface to get a unform level surface for laying of membrane treatement all as directed by Engineer-in-Charge. |
| 43 | M/L for PCC 1:2:4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engineer-in-Charge |
| 44 | Supply only integral waterproofing compound. |
| 45 | OVERPLAY - PU BASED ELASTOMERIC LIQUID MEMBRANE SYSTEM FOR EXPOSED ROOF:- M & L for providing and applying polyurethane liquid applied roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roof of exterior wall and exposed surface with solid content not less than 60% and solar reflectance index 106 as per (ASTM E1980:19) / tear strength -20N/mm (free film, 14 days, + 30\"C ) (ASTM D624) and tensile adhesion strength >1.5N/mm2 (ASTM D4541) for fosroc one coat of nitoprime WB and two coats of brushbond roof guard premium applied by brush or roller to achieve minimum thickness 1mm DFT (Dry film thickness) or Equivalent in other makes.Note:The Treatment should be carried out through Authorised applicator only |
| 46 | Disconnecting existing tanks of Exc 500 n not exc 1000 capacity(in ltrs) , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after carrying out Roof treatment with all accessories all as specified and directed by Engineer-in-Charge |
| 47 | Dismantling wall and ceiling boards(fibre,pulp, unsulation etc) or unsulation board/slab/beam kob, any thickness including cover gillet complete all as specified and directed by Engineer-in-Charge |
| 48 | S&FArm Gyp-FB ceiling snow Frost vinyl face, washable metallized polyester foil backing ,vinyl covered edges, suspended ceiling on suspension system. Panels shall be of Size 600 mm x 600 mm x 9 mm, having 7 kg/SQM,including providing Grid system for fixing ceiling tiles shall comprise of suspension system with true horizontal level, suspended on inter locking tegular “Select” system with 15mm black flanges incorporating a 4mm central reveal in black colour and a load carrying capacity of minimum 14.50 kg/m2 with birdsmouth notches metal grid of hot dipped galvanized steel sections consisting of main \"T\" runner with suitably spaced joints to get required length and of size 15x32 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 15mmx25mm made of 0.30 mm thick (minimum) sheet, 1200mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200mmx600 mm and secondary cross \"T\" of length 600 mm and size 15mmx25mm made of 0.30 m thick (minimum) sheet to be interlocked at middle of the 1200mmx600 mm panel to form grids of 600mmx600mm and wall angle of size 20mmx15mmx0.3 mm and laying false ceiling tiles of approved texture in the grid including, required fitting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85mm x 30mm x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15 mm of all T-sections all complete for all heights as per specifications, drawings incl dismantling of old ceiling, all as specified and directed by Engineer-in-Charge. |
| 49 | Note for Sl item No 1 to 48 :-(i) Unit rate quoted shall include for necessary scaffolding, trestles, ladders & cradles required for execution of the work and protective works.(ii) Necessary spreading and removing coverings to doors, windows, floors, fittings etc to protect them from splashes and cleaning of the doors/windows and floors after carrying out painting shall be made by the contractor. |
| 50 | Excavating in post holes (or similar holes) in hard dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 51 | Cement concrete Type B2 1:2:4 (40 mm graded aggregate) in foundations, filling and mass concrete |
| 52 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe -410-W(Gde-E-250 qaulity-B) all as specifed and directed by Engineer-in-Charge. |
| 53 | Mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,Diameter of neck in 16 to 20 mm each screwed end to be fitted with washers and one hexagonal or square nut Length exc 22.5cm and n exc 30cm long |
| 54 | M&L for preparation of new steel surfaces, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of anti-corrosive epoxy(poly Urethane based)over a coat of epoxy primer of approved make completeall as specified and directed by Engineer-in-Charge. |
| 55 | Note for Sl item No 49 to 53 :-(i) Unit rate quoted shall include for necessary scaffolding, trestles, ladders & cradles required for execution of the work and protective works. |
| 56 | Excavation in trenches n.exc 1.5m wide n.exc 1.5m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5m depth and getting out in hard dense soil complete all as specified |
| 57 | Returning filling in sof/loose soil incl. spreading levelling watering and well ramming in layer n.exc. 25 cm thick. |
| 58 | Removal excavated surplus soil to a distance n.exc. 50 m and depositing where directed by Engineer-in-Charge at level n.exc. 1.5 m above the starting point all as directed by Engineer-in-Charge. |
| 59 | Demolition of cement concrete (unreinforced)in floors and in any description |
| 60 | S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches |
| 61 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete of flat. |
| 62 | M&L for PCC 1:2:4,type B-1(using 20mm graded aggregate.) as in coping. |
| 63 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate), 75mm thick as in plinth protection, subbase offlooring etc. |
| 64 | M/LPre-cast cement concrete block masonry with Type C-1 1:3:6 (20MM graded agg) solid blocks, exc. 10 cm in width and setting in CM 1:6,complete |
| 65 | supply only water proofing compound |
| 66 | M & L 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4)for external surface finished even and smooth without using extra cement. |
| 67 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 68 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power)including unserviceablelight fittings, switch board complete,switch sockets, ceiling roses, pendants, regulators, sockets, etcandremoving materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 69 | M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-Charge.(a)One light point controlled by one switch |
| 70 | All as per item No 67 here-in-before One Ceiling fan point controlled by one switch |
| 71 | All as per item No 67 here-in-before One Exhaust fan point controlled by one switch |
| 72 | All as per item No 67 here-in-before One 3 pin socket outlet, 5 Amp independent |
| 73 | All as per item No 67 here-in-before One 3 pin socket outlet, 5 Amp on the same board with other switches |
| 74 | All as per item No.67 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-Charge. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately). |
| 75 | S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 76 | S & F socket out let, 2 in 1, 3 pin,5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 77 | S & F Switch socket combination, 2 in 1,5 Amps,flush type, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 78 | S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-Charge. |
| 79 | S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by Engineer-in-Charge by engineer in charge. |
| 80 | Supply and fixing of 20 Watt LED 6500 K (PRIDE PLUS)inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Cat Part No LHEXACP7FN1W020 ofHAVELLS or equiviliant to Shakti/Philips. |
| 81 | Supply and fixing LED wall light / LED Picture Light, aesthetically designed with multiple body colour options, high efficieny LED, opaque diffuser, inbuilt driver, suitable for highlighting wall hangings. 15 watt 220 V AC decorative typeincluding connecting up with three core flexible copper conductor cable of suitable size complete. Cat Part No SZWPFPX015 of Shakti or equivlent to Bajaj/Philips/Havells |
| 82 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 83 | Supply only in replacement of 20 Watt LED streetlight fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, including coneecting up with 2/3 core flexible coppper conductor cable, compete all as specified and directed by Engineer-in-Charge. Cat Part No LHETAVU7PA7J020 of Havells or equivlent to Shakti/Philips/ Halonix |
| 84 | Supply & fixexhaust fans steel body AC single phase 230/ 240 V of size 380 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in quoted rates.(Note:- Old unsv exhaust fan shall be deposited at MES store yard ) |
| 85 | S & F Triplepole and earth enclosure with a three pin and earth plug and socket complete with one triple pole 63 A MCB all as specified and directed by Engineer-in-Charge |
| 86 | M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 X 4 mmby means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board. Note :- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition. |
| 87 | S&F Triple pole and neutral (6Way) Double door,(VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and boltincluding matching the existing surfaceall as specified and directed by Engineer-in-Charge , Make Havellsor equivalent indoasian/Standard. |
| 88 | S&F MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge Make:Havells QVE series or equivlent legerend/standard/indoasian |
| 89 | S&F in repairs MCB SP 5 To 32 AMP,single pole 240 Volts 10KA \"\"C\"\"&\"\"B\"\" curve , as per site requirment,Complete all as specified and directed by Engineer-in-Charge. |
| 90 | S&F in repairs MCB SPN 6-32 AMP,240 Volts 10KA \"C\" curve , Complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supply and fixing MCB TPN/FP40 To 100 AMP 415V 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 92 | S&F in MCB Encloser (3P+N+E) with63A MCB with Plug & Socket with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge. |
| 93 | S&F in MCB Encloser (2P+E) with32A MCB with Plug & Socket with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge. |
| 94 | M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and Four runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed by Engineer-in-Charge.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 95 | Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 50 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge. |
| 96 | Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site |
| 97 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 3 Phase,415V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 98 | Supply and lay in trenches / along the wall / floorpipes GI light grade of size 50 mm dia with and including all fittings and accessories including taking down old U/S pipe complete all as specified and and directed by Engineer-in-Charge for cable protection |
| 99 | Cutting bituminus roadas per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system. |
| 100 | Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose Soil complete as specified & directed by Engineer-in-Charge |
| 101 | Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/soil complete all as specified and directed by Engineer-in-Charge |
| 102 | Removing excavated material n. exc. 50 M away and depositing where directed by Engineer-in-Charge at a level n. exc. 1.5 M above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 103 | M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand all as directed by Engineer-in-Charge and specified. |
| 104 | Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed by Engineer-in-Charge. |
| 105 | Supply, installating, commissioning and testing of commercial kitchen mechanical chimney comprising of the following items: (i) Exhaust hood regular type mounted centrally/on wall ,rectangular shape 7 foot long and 3 foot wide made out of 0.8 mm thick SS(316 grade) sheet with SS Grease Filters (SS 316) with suitable size SS grills. (ii) SS ducting (24 SWG)(SS 316) 15 foot long with mild steel brackets for fixing/mounting on ceiling/ wall, suitable flanges & connections, Tee, Elbows etc. to extract the fumes.(iii) SS ducting (24 SWG)(SS 316) 15 foot long with mild steel brackets for fixing/mounting on ceiling/wall, suitable flanges & connections,Tee,Elbows etc for recirculating cool air. (iv) Centrifugal exhaust Blower driven by 3HP, 1440 RPM, 415V, 50 Hz, 3 phase electric induction motor with suitable damper for achieving 3000 CFM as per site condition with heavy guage SS casing having robust construction, flanges at both end, die cast aluminium impeller having aerofoil design with adjustable pitch angle with and including civil work complete all as per specified and as directed by Engineer-in-Charge.Note: (a) All civil works such as making opening in brick/stone walls including to make good to match with the surroundings, mounting plinth for blower motor assembly etc, shall be carried out by the contractor and the cost of the same shall be deemed to be included in the rate quoted. (b) All mild steel brackets,supports, clamps, flanges etc., as required shall be carried out by the contractor and the cost of the same shall be deemed to be included in the rate quoted. (c) Wiring and control switches as required shall be measured separately under appropriate items of BOQ. (d) Test certificate for motor , blowers, etc ,shall be submitted duly tested from NABL accredited lab. |