Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Madakkathara panchayath -Supply, Erection,Testing & Commissioning of Clear Water Pumpset at Chirakkekod-82 HP, H=75 m, Q=56.37 lps |
| 2 | OD240362/2024-2025:Design, Supply, erection, testing and commissioning, 82 HP Centrifugal motor pump set having Discharge - 56.37 LPS and Head - 75m, including maintenance for 2 years of pumpset and includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge - 56.37 lps, Total head - 75 Mtrs.. Modification may done for mono block pump sets 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete Motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star-Delta Starter for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with Main, Delta and Star contactors etc. complete 4. Panel board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards.7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 28348. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety. |
| 3 | OD240368/2024-2025:MV Panel Boards (Main SB)- Design, engineering, supply erection, testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight & vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, PVC sleeved, air insulated and of adequate size as mentioned below, for operation on 3 Phase, 4wire, 415 Volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be of reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. Main Switch board (MSB) 400A TPN bus bars Earthing conductor: 25x6 mm, copper. Incomer- 250A 36kA, 4 pole Thermal Magnetic release, Isolation duty MCCB with 3 O/C & 1 E/F release set at 225 A – 1No, 200 A ,25KA TP MCCB - 2Nos ,125 A ,25KA TPN MCCB-1No and 63A,25KA TPN MCCB .1No as outgoings and shall be fitted with metering chamber for KSEBL metering having sealing facility for meter chamber and CT Chamber with adequate space for accommodating LT TOD meter and should be provided with 4 Nos Resin Cast Current transformers on the Incoming side of Class 0.5S, 10VA ,200/5A capacity and with other Metering equipments like voltmeters, ammeters, selector switches, indicating lamps etc |
| 4 | OD240366/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185Sqmm |
| 5 | OD240373/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5C x 185Sq mm |
| 6 | OD240374/2024-2025:LT TOD Meter-Supply, erection, testing and commissioning of LT TOD meter of reputed make, 415V, 3 Phase 4 wire,Class 0.5S -/5A, with data downloading port. |
| 7 | OD240364/2024-2025:Testing and Conveyance Charges for testing of 4Nos LT resin cast CTs (4Nos)and TOD Meter at TMR testing lab of KSEBL |
| 8 | OD240370/2024-2025:PIPE EARTHING WITH 2.5M PIPE -Supply and providing pipe earthing as per IS 3043 with 2.5 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. |
| 9 | OD240372/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. |
| 10 | OD240369/2024-2025:Supply & laying the following sizes of Earth Strip for earthing interconnection, termination and leads, for continous earthing along with cables tinned at terminals etc. complete. 25 x 6 mm Copper Strip |
| 11 | OD240367/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x3mm copper strips. |
| 12 | Madakkathara panchayath -Supply, Erection,Testing & Commissioning of Clear Water Pumpset at Kachithod CF Pump-54 HP, H= 97 m, Q=28.47 lps |
| 13 | OD240350/2024-2025:Design, Supply, erection, testing and commissioning, 54 HP Centrifugal motor pump set having Discharge - 28.47 LPS and Head - 97m, including maintenance for 2 years of pumpset and includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge - 28.47 lps, Total head - 97 mtrs.. Modification may done for mono block pump sets 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star-Delta Starter for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with Main, Delta and Star contactors etc. complete 4. Motor Control Panel Board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards.7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 28348. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety. |
| 14 | OD240357/2024-2025:Testing and Conveyance Charges for testing of 4Nos LT resin cast CTs (4Nos)and TOD Meter at TMR testing lab of KSEBL |
| 15 | OD240359/2024-2025:LT TOD Meter-Supply, erection, testing and commissioning of LT TOD meter of reputed make, 415V, 3 Phase 4 wire,Class 0.5S -/5A, with data downloading port. |
| 16 | OD240358/2024-2025:MV Panel Boards (Main SSB)- Design, engineering, supply erection, testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight & vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, PVC sleeved, air insulated and of adequate size as mentioned below, for operation on 3 Phase, 4wire, 415 Volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be of reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. Main Switch board (MSB) 400A TPN bus bars Earthing conductor: 25x6 mm, copper. Incomer- 200A 36kA, 4 pole Thermal Magnetic release, Isolation duty MCCB with 3 O/C & 1 E/F release set at 133 A – 1No, 125 A ,25KA TP MCCB - 2Nos ,and 63A,25KA TPN MCCB - 2No as outgoings and shall be fitted with metering chamber for KSEBL metering having sealing facility for meter chamber and CT Chamber with adequate space for accommodating LT TOD meter and should be provided with 4 Nos Resin Cast Current transformers on the Incoming side of Class 0.5S, 10VA ,200/5A capacity and with other Metering equipments like voltmeters, ammeters, selector switches, indicating lamps etc |
| 17 | OD240361/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5C x 95Sq mm |
| 18 | OD240353/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185Sqmm |
| 19 | OD240351/2024-2025:PIPE EARTHING WITH 2.5M PIPE -Supply and providing pipe earthing as per IS 3043 with 2.5 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. |
| 20 | OD240355/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. |
| 21 | OD240356/2024-2025:Supply & laying the following sizes of Earth Strip for earthing interconnection, termination and leads, for continous earthing along with cables tinned at terminals etc. complete. 25 x 6 mm Copper Strip |
| 22 | Pananchery panchayath-Supply, Erection,Testing & Commissioning of Clear Water Pumpset at peechi-CF pump 48 HP, H-103m , Q=22.6 lps |
| 23 | OD240376/2024-2025:Design, Supply, erection, testing and commissioning, 48 HP Centrifugal motor pump set having Discharge - 22.60 LPS and Head - 103m, including maintenance for 2 years of pumpset and includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge - 22.60 lps, Total head - 103 mtrs.. Modification may done for mono block pump sets 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star-Delta Starter for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with Main, Delta and Star contactors etc. complete 4. Panel board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards.7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 28348. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety. |
| 24 | Puthur panchayath-Supply, Erection,Testing &Commissioning of Clear Water Pumpset at Peechi-CF pump -160 HP, H-167m, Q-98.03 lps |
| 25 | OD240343/2024-2025:Design, Supply, erection, testing and commissioning, 160 HP Centrifugal motor pump set having Discharge - 98.03 LPS and Head - 167m, including maintenance for 2 years of pump set It includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge – 98.03 lps, Total head - 167 mtrs.. 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty Soft Starter for the above motor with over voltage and under voltage protections, Single phasing preventer, Over load relay with motor protection relays, and shall be provided with multifunction digital meter and indicators. 4. Panel board (suitable for operating three pump sets but to run two pump sets at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 3 Nos of suitable capacity MCCB as outgoing (the outgoing MCCBs are to be fitted with interlocking facility so that two of them can be operated at a time) providing suitable size Aluminium/Copper bus bars to inter connect the above MCCBs and is to be fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per CEA regulations and code of practice. The panel shall be fitted on a common base frame on suitable foundation5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards.7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 28348. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety. |
| 26 | OD240347/2024-2025:Supply & laying of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)from Transformer to MV Panel 3.5C x 240Sq mm |
| 27 | OD9957/2025-2026:HT Power Cables - Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 185 Sqm |
| 28 | OD9962/2025-2026:HT Cable Terminations - Supplying and making indoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 185 Sqmm |
| 29 | OD240349/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 240Sqmm |
| 30 | OD240345/2024-2025:MV Panel(MSB) for 500KVA Transformer : Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board made out of 14SWG thick CRCA sheet fully compartmentalized, and painted with epoxy paints of approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, Digital multi function meter, ammeters with CTs, earth fault relay, Standby earth fault relay through neutral CTs, voltage protection relay and Voltmeter with selector switch, all connections and inter-connections including mounting the following switch gears. (the panel shall be fabricated by a ISO and CPRI approved vendor with SC,HRT,IP 42,IEC 61439 Type Test Certificate) (Provision for energy meter in all outgoings shall be provided, Protection relays shall be provided as per electrical inspectorate standard) (a)Incomer: 1No 800A ,50kA 4P EDO microprocessor based ACB with overload, short circuit, instantaneous and earth fault protections and with shunt trip and UV release with out any deration up to 50 degree - 1 set CTs: 1000/5 15 VA CL0.5 -4 Nos RYB phase indicating lamps (LED ) with control fuses and switches -1 set. Digital Energy meter with RS 485 port, class 0.5s and Outgoing (1) 630A 50KA 4P current limiting type MCCB with encapsulated double break mechanism Nos (One for taking supply to 160HP Motor Change over Panel and one spare) -2 Nos (3) 160A 50KA 4P current limiting type MCCB with encapsulated double break mechanism -3 Nos (one for supplying the 50HP motor change over panel and one for future APFC panel and one spare)-3Nos (4) 100A , 36kA ,4P,MCCB -1No ( for future lighting purpose) 5)Energy meter with RS 485 including necessary CTs |
| 31 | OD9944/2025-2026:Supply and errection and testing of suitable neutral CT ,5P10 Class for 11KV/433V ,500VA transformer as per Standards including weather proof box , supports, connections to Transformer Neutral etc. complete |
| 32 | OD240344/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. |
| 33 | OD240348/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of LT panel boards, equipments and inter connection of earth pits 25X 6 mm COPPER Strip |
| 34 | OD240346/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of LT panel boards, equipments and inter connection of earth pits 25X 3 mm COPPER strip |
| 35 | OD24949/2025-2026:Providing Transformer fencing to a height of 1.8m above ground level using MS Angle frames of sizeISA 50x50x6mm for outer frame, 2 runs of 40x6 MSflat for horizontal bracing and grills with MS rods 8 mmDia @ 10cm c/c for verticals, providing gate withlocking arrangements, providing danger board & nameboard, embeding the legs in cement concrete 1:2:4,footing of size 30cmx30cmx50cm, painting withsynthetic enamel paint two coats over one coat of ironprimer etc complete, incl cost of transportation |
| 36 | OD24948/2025-2026:Cleaning and levelling of transformer yard, spreading40 mm broken stone in yard for a thickness of 10 cmabove bed of 10 cm thick 6 mm broken stone, afterconstructing a curb wall of height 20cm above groundand 10cm below level including cost of all materialsand charges for conveying, spreading, consolidatingetc. |
| 37 | Construction of Pump station at Peechi |
| 38 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 39 | 4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 40 | OD240375/2024-2025:Dry rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) including cost of through stone and bond stone. |
| 41 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 42 | 50.2.25.1:Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 43 | 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 44 | 5.33.2.1:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementAll work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 45 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 46 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 47 | 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) |
| 48 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 49 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 50 | 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 51 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 52 | 13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre |
| 53 | 13.82.2:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats |
| 54 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 55 | Conveying, fixing and charging of existing 500KVA transformer at Peechi after mace works |
| 56 | OD271191/2024-2025:Conveying and fixing existing 500KVA transformer after overhauling and oil filtration works |
| 57 | OD271194/2024-2025:oil filtering of existing 500KVA transformer at Peechi |
| 58 | OD271220/2024-2025:Oil top up in 500KVA transformer at Peechi Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail