| 1 | Supply & fixing of 7 mtr Fiber Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 2 | Supply & fixing of 8 mtr Fiber Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 3 | Supply & fixing of 9 mtr Fiber Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 4 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 5 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 6 | Supply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 7 | Supply & fixing of 8 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 8 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 9 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. As per Specification of Engineer Incharge. |
| 10 | Supply & fixing of 06 mtr steel tubular pole approved make (top dia 60-70mm, Bottom dia 130-155 mm and base plate 12mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) as per specified by the engineer incharge of the diamension of the pole & RCC foundation as per bearing capacity of the pole and quality as per Indian Standard IS-1944(Part V)-1981 or the latest IS of the Steel Tublar pole and also 50-60 Watt LED Light with specification of LED Light IP-66/67 and above lumen power 110 to 130 lm/W with all necessary items etc complete and also specified Q.A.P plan of the pole by Engineer Incharge. |
| 11 | Supply & fixing of 08 mtr steel tubular pole approved make (top dia 60-70mm, Bottom dia 130-155 mm and base plate 12mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) as per specified by the engineer incharge of the diamension of the pole & RCC foundation as per bearing capacity of the pole and quality as per Indian Standard IS-1944(Part V)-1981 or the latest IS of the Steel Tublar pole and also 50-60 Watt LED Light with specification of LED Light IP-66/67 and above lumen power 110 to 130 lm/W with all necessary items etc complete and also specified Q.A.P plan of the pole by Engineer Incharge. |
| 12 | Supply & laying of 10 mm2 aluminium 2 core armoured cable with suitable size of P.V.C/ Flexible Pipe/H.D.P.E pipe with proper depth which are define by the standard of the laying of cabling work & also with suitable size of M.C.B of connecting the cable & pole jointing etc. Complete in all respect. |
| 13 | Supply & laying of 16 mm2 aluminium 4 core armoured cable with suitable size of P.V.C/ Flexible Pipe/H.D.P.E pipe with proper depth which are define by the standard of the laying of cabling work & also with suitable size of M.C.B of connecting the cable & pole jointing etc. Complete in all respect. |
| 14 | Supply & laying of 25 sq. mm 3-1/2 core armoured cable with suitable size of P.V.C/ Flexible Pipe/H.D.P.E pipe with proper depth which are define by the standard of the laying of cabling work & also with suitable size of M.C.B of connecting the cable & pole jointing etc. Complete in all respect. |
| 15 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. |
| 16 | S&F of 63 Amp. 415 V metal clad T.P. rewireable type switch fuse unit on angle iron bracket complete in all respect. |
| 17 | Supply and fixing of modern lasercut design light column (Total heightSupply of lite Modern laser cut design light column (Total height -3500 mm), in square cross section (150x150mm) MS, MS Sheet thick-ness 2.3mm including laser profile jali pattern(2000n-m height of laser MS sheet) cladded with opal acrylic diffuser and additional post top head with light element, MS pedestal base plate 250x250x12mm, black n colour, coated for high corrosion resistance UV protected PU paint, silicon gasket, SS Fasteners, Integral driver, IP66, IK07.360 degree light distribution in the column part is provided with 45 watt Led light mounted vertically (min 90lm/watt, top head comprising with 4X20Watt led lights (min 110 Im/watt) with low glare line of vision, Efficacy>85%. co related colour Temperature (ССТ) 3000-350010 KK, Ingress Protection P-66. Production Tolerance +-3% as per IS, LED Life 50000 Burning hours, Pre wired, with earth connection, Integral Junction etion chamber for cable termination- with 4Way 32 Amps heavy duty connector-1 No SP MCB and Driver of both lighting Units.bolts, Fasteners and all accessories. Operating Voltage - 240V AC, Frequency50 Hz, CRI>70, PF -0.95, THD <10%, Internal1 Surge protection 4KV External Surge Protection 10KV. Total wattage -125 watt complete in all respect as per ELas per Engineer-in-charge. (MR) |
| 18 | Supply and fixing of modern lasercut design light column (Total heightSupply of lite Modern laser cut design light column (Total height -3500 mm), in square cross section (200x200mm) MS, MS Sheet thick-ness 2.3mm including laser profile jali pattern(2000n-m height of laser MS sheet) cladded with opal acrylic diffuser and additional post top head with light element, MS pedestal base plate 250x250x12mm, black n colour, coated for high corrosion resistance UV protected PU paint, silicon gasket, SS Fasteners, Integral driver, IP66, IK07.360 degree light distribution in the column part is provided with 45 watt Led light mounted vertically (min 90lm/watt, top head comprising with 4X20Watt led lights (min 110 Im/watt) with low glare line of vision, Efficacy>85%. co related colour Temperature (ССТ) 3000-350010 KK, Ingress Protection P-66. Production Tolerance +-3% as per IS, LED Life 50000 Burning hours, Pre wired, with earth connection, Integral Junction etion chamber for cable termination- with 4Way 32 Amps heavy duty connector-1 No SP MCB and Driver of both lighting Units.bolts, Fasteners and all accessories. Operating Voltage - 240V AC, Frequency50 Hz, CRI>70, PF -0.95, THD <10%, Internal1 Surge protection 4KV External Surge Protection 10KV. Total wattage -125 watt complete in all respect as per ELas per Engineer-in-charge. (MR) |
| 19 | Construction Of RCC Pole foundation Size 600 mm x600 mm.x2100 mm for 11 mt. long street light octogonal pole complete in all respact as per direction of engineer in charge. |
| 20 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 70 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA |
| 21 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 90 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA |
| 22 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 120 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA |
| 23 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 150 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA |
| 24 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 200 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA |
| 25 | Two Coated painted With Material Street Light Pole With Hydra Charges & Pole Conveyance Charges. |
| 26 | F.R.P Painting of the Pole with all material labour etc & work Will be done as per Engineer Incharge instructions. |
| 27 | S/F of the F.R.P Connecting plate with labour, Material fitting at the pole & work Will be done as per Engineer Incharge instructions. |
| 28 | S/F of the F.R.P Pole cover with all material, labour etc & work Will be done as per Engineer Incharge instructions. Please Enable Macros to View BoQ information |