| 1 | dismentalling of RCC work with all complete |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter includingchowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : area 3 sq. metres and below |
| 3 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping,sand papering and preparing the surface smooth including necessary repairs to scratchesetc. complete |
| 4 | R.C.C. work with cement, coarse sand and 20 mm gauge stone ballast in proportion of (1:1.5:3) in Plinth Beam |
| 5 | Mild steel or iron in plain work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. Bend hooks and authorized overlapping shall be measured (@ 10% of Concrete) |
| 6 | First Class brick work in 1:4cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of materials, labour, T&P etc. required for proper completion of the work thickness of wall not be less than one brick. |
| 7 | 12mm thick plaster with cement mortar in proportion of 1:4 consisting of cement and coursesand (F.M. not less than 2.25 mm) over brick work including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 8 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 9 | Finishing wall with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied a 1.43 ltri 10 sqm over and including priming coat of exterior primer applied a 2.20 10 sqm) |
| 10 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:2/21(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over theRCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm Engineer-in-charge.of cement admixed with water proofing compound conforming to IS : 2645 and approved by(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.\"All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 11 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from watersupply line and removing from the terrace including shifting at ground level as per directionof Engineer-in-charge |
| 12 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba allcomplete as per directions of Engineer-in-Charge. |
| 13 | Dismantling tile work in floors and roofs laid in cement mortar including stacking materialwithin 50 metres lead. |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 15 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge DSR-11.48.2 |
| 16 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperturewith matching wood beading |
| 17 | Providing and fxing Pre-laminated flat pressed 3 layer (medium density) particle boardor graded wood particle board IS : 3087 marked, with one side decorative and other sidebalancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screwsand fttings wherever required, edges to be painted with polyurethane primer (fttings to bepaid separately). |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fxed in position with hold fast lugs or with dash fasteners of requireddia & length (old fast lugs or dash fastener shall be paid or separately). |
| 19 | Providing and fxing wire gauge shutters using galvanized M.S. wire gauge of average widthof aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows andclerestory windows with hinges and necessary screws |
| 20 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazedshutters or doors, windows and clerestory windows (Area og opening for panel insertsexcluding portion inside grooves or rebates to be measured). Panelling for panelled orpanelled and glazed shutters 25 mm to 40 mm thick : |
| 21 | Providing and fxing chromium plated brass curtain rod having wall thickness of 1.25mmwith two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc.,wherever necessary complete : |
| 22 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. |
| 23 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) withnecessary screws etc. complete (Copper oxidised as per IS 1378) |
| 24 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessaryscrews etc. complete (Copper oxidised as per IS 1378) |
| 25 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : |
| 26 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and apair of lever handles of approved quality with necessary screws etc. complete. |
| 27 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to 1S: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. |
| 28 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 29 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 30 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 31 | Supply and fixing of refrigerator with all complete |
| 32 | Inverter with batteries ( luminus ) as for marketrate |
| 33 | Air Conditioning 2 tons (Voltas 5 star rating) as for gem rate |
| 34 | Air Conditioning 1.5 tons (Voltas 5 star rating) as for gem rate |
| 35 | Dining table with all complete |
| 36 | Sofa set with all complete |
| 37 | Large double bed With all complete |
| 38 | Small bed with all complete |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 40 | Supply and fixing of curtain for window and door with all complete |
| 41 | Electric Fitting 5% |
| 42 | sanatary Fitting 8% |
| 43 | contigency 2% |
| 44 | Add 18 % GST Please Enable Macros to View BoQ information |