| 1 | Taking out window type AC 1.5/2 ton and reinstallation including window opening cutting and provision of packing material as per site requirement including closing of old opening and making new opening all as specified and directed at site. |
| 2 | S&F in replacement compressor of window type air conditioner 1.5/2 Ton capacity ofexisting make and providing new sealed compressorunit of same size and make, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and includinginitialcharging of Refrigerant gas R-22, compressor oil, testing commissioning including taking down old unserviceable compressor, complete all as specified and directed . |
| 3 | S&F in replacement compressor of split type air conditioner 1.5/2 Ton capacity ofexisting make and providing new sealed compressorunit of same size and make, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and includinginitialcharging of Refrigerant gas R-22, compressor oil, testing commissioning including taking down old unserviceable compressor, complete all as specified and directed . |
| 4 | Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nutof any size as required and including insulating material etc and testing complete all as specified and directed. |
| 5 | S&F in replacement of thermostat switch for any capacity window/split type air conditioner complete all as specified and directed. |
| 6 | S&F in replacement of over load protector for any type AC 1.5/2 Ton capacity complete all as specified and directed. |
| 7 | S&F in replacement of condenser fanblade suitable for 1.5/2 ton window type air conditioner of any make complete all as specified and directed. |
| 8 | S&F in replacement of condenser fan motor 1/5 HP 230 volt AC Cooper winding single phase double shaft suitable for 1.5 ton window type AC complete all as specified and directed. |
| 9 | S&F in replacement offront grill suitable for window type air conditioner capacity 1.5 Ton as per existing complete all as specified and directed. |
| 10 | S&F in replacement Single pole and neutral, Sheet Metal enclosure with Socket plug Top and MCBs. and two pin and earth plug and socket with one single pole MCB 25 Ampscomplete all as specified and directed. |
| 11 | M&L for taking down window/split type air conditioner of 1/1.5/2 Ton capacity / make / size at site,opening top and side covers disconnecting all electrical controls components and cleaning the complete units with electric blower and sprayingclean water, descaling withcoil shine solution in both side of cooling coil and condenser, brush cleaning with nylon brush and washing with clean water, refixing the covers and making electrical connection of all the controls and components, installing back the same on site testing, commissioning incl black painting to bottom complete all as specified and directed. |
| 12 | M&L forGas rechargingin window/split type AC 1.5 Ton/2 Ton capacity of any make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. |
| 13 | S&F in replacement of PCB board suitable for 1.5/2 Ton window/split AC/DC including display & remote of existing make complete all as specified and directed. |
| 14 | S&F in replacement of starting capacitor 45 MFD complete all as specified and directed. |
| 15 | S&F in replacement of starting relay for 1.5/2 ton capacity complete all as specified and directed. |
| 16 | S&F in replacement condensing outdoor unit of window/Split type AC of capacity 1.5 TR capacity with anti Corrosive paint. fins, condensing coil, coil frame, wiring kit starting and running capacitor, relay condensing motor, with blade completeall as specified and directed. |
| 17 | S&F in replacement indoor unit of window/Split type AC of capacity 1.5 TR capacity with anti Corrosive paint.fins, evaporative coil, air filter, wiring kit starting and running capacitor, fan motor, with blade completeall as specified and directed. |
| 18 | Taking out Split type AC 1.5/2 ton and relocation/ reinstallation as per site requirement including all connecting accessories i.e. back plate nuts boltscomplete all as specified and directed at site. Note :Copper piping will be measured and paid separately. |
| 19 | Supply & fixing in replacement Voltage Stabilizer of capacity 5 KVA for automatic operation, Single Phase, naturally air cooled, indoor type, designed for input variation between 170 Volt to 270 Volt and with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and connecting up all as per manufacturer’s instructions & complete all as specified and directed at site. |
| 20 | S&F in replacement new remote assembly for split/windowtype AC 1.5/2 ton ofany make& existing modelcomplete all as specified and directed.. |
| 21 | Taking down old sealed unit of refrigerator 165-310 litres capacity of any make and providingnew sealed compressor ofsame size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. |
| 22 | S&F in replacement of freezer with cooling coil for 165 to 310 litres capacity refrigerator of existing make complete all as specified and directed. |
| 23 | S&F in replacement oflamp 15 watt screw / Pin type suitable for any make and capacity refrigerator complete all as specified and directed. |
| 24 | S&F in replacement of Overloding relay suitable for low/high speed refrigerator compressor of any capacity complete all as specified and directed. |
| 25 | S&F in replacement ofthermostat suitable for any capacity refrigerator complete all as specified and directed. |
| 26 | M&L for Charging with refrigerantgas 134a after vacuuming /pressure testing and leakage testing including flushing the system in the refrigerator of any make of165 to 310 litres capacity complete.all as specified and directed. |
| 27 | S&F in replacement of fan moter of Capacity 165 to 330 litres suitable for refrigerator of any make and capacitycomplete.All as specified and directed by Engr in charge. |
| 28 | S&F in replacement of PCB board suitable for refrigerator of existing make and capacity 165 litres to 300 litres complete all as specified and directed. |
| 29 | M&L for taking down sealed unit of deep freezer upto 320 litres capacity of any make and providing in replacement new sealed compressorof same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. |
| 30 | S&F in replacement of Overloding relay suitable for deep freezer upto 320 litres capacity complete all as specified and directed. |
| 31 | S&F in replacement of thermostat suitable for deep freezer upto 320 Litrescapacity complete all as specified and directed. |
| 32 | S&F in replacement of fan motorsuitable for deep freezer any type complete all as specified and directed. |
| 33 | S&F of deep freezer complete body of capacity 320 litres made out of food grade aluminium inner liner, insulated with CFC free PUF suitable for continuous operation at zero temperature, including lid handle, rubber gasket, drain provision and base frame complete all as specified and directed at site. |
| 34 | M&L for taking downold unserviceable compressor of water cooler of capacity 40/80 litres any make/size and providing new sealed compressor and connecting up suction and discharge copper pipe with gas welding, pressure testing of leakage, leakage rectification, vacumising and including initial charging of refrigerant gas R 22, testing, commissioning complete all as specified and directed. |
| 35 | Description all as per item No 34.00 above but water cooler of capacity 120/150 litres complete all as specified and directed at site. |
| 36 | S&F in replacement of starting/running capacitor 10 to 80 mfd suitable for water cooler of any capacity complete all as specified and directed. |
| 37 | S&F in replacement of thermostat switch for water cooler any cap complete all as specified and directed. |
| 38 | S&F in replacement of condenser fan motor 1/ 3.5 HP 250 Volts AC Single phase suitable for water cooler complete all as specified and directed. |
| 39 | S&F in replacement of condenser fan blade for fan motor suitable for water cooler of any make/capacity complete all as specified and directed. |
| 40 | M&L for Gas charging in water cooler of any capacity and make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. |
| 41 | S&F in replacement of PVC float valve assembly suitable for water cooler/Desert Cooler of any size/capacity non metallic body complete all as specified and directed. |
| 42 | S&F in replacement PVC waste pipe 32mm, dia with complete fittings suitable for water cooler of any make and capacity complete all as specified and directed. |
| 43 | S&F in replacement water tap in steel body suitable for any capacity of water cooler with fitting arrangement such as washer and suitable size nipple all as specified and directed by Engr-In-Charge |
| 44 | S&F in replacement ofdesert cooler submersible pumpsingle phase complete all as specified and directed. |
| 45 | S&F in replacement ofdesert cooler fan motor duly wounded COPPER suitable for operation on 230 V single AC supply 3 speed 1400 RPM complete all as specified and directed. |
| 46 | S&F in replacement of selector switch for controlled speed complete all as specified and directed. |
| 47 | S&F in replacement of wood wool pad superior quality for desert cooler of capacity 4000 Cum/hr 5000 Cum/hr having minimum weight 450 gms complete all as specified and directed. |
| 48 | S&F in replacement of capacitor 4 mfd suitable for desert cooler complete all as specified and directed. |
| 49 | S&F in replacement ofPVC pipe 15 mm dia of superior quality complete all as specified and directed. |
| 50 | Dismantling , cutting and taking out old winding of desert cooler fan motor of any make and M&L for rewinding of the same with super enameled copper winding wire and providing shallac varnish, testing commissioning complete all as specified and directed. |
| 51 | S&F in replacement of PVC water distributor 3 way for desert cooler of superior quality complete all as specified and directed. |
| 52 | S&F in replacement of PVC fan blade suitable for 18/20 inch sweep desert cooler motor complete all as specified and directed. |
| 53 | S&F in replacement of desert cooler body (overall mimimum size 26 inch x26 inchx39 inch) made out of 22 gauge galvanized sheet, with painting & storage tank capacity should be minimum 120 ltr,including front adjustable grill both side i.e. horizontally and vertically and suitable three side slotted shutter Including necessary fabrication, belding works complete all as specified and directed. |
| 54 | S&F in replacementadjustable front grill made of GI sheet ,having with air direction control system with knob, P/T switch, indicator lamp,complete suitable for 20\"/24\" desert cooler. complete all as specified and directed. |
| 55 | S&F in replacement Plug top 16A, 3 pin, 230 AC, ISI markedcomplete all as specified and directed. |
| 56 | S&F in replacement of PVC cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC, complete all as specified directed |
| 57 | S&F in replacement of plug top 5 Amps 3 pin, ISI marked complete all as specified and directed. |
| 58 | Taking down ceiling fan of any make and 1200mm sweep at site, cleaning dust and opening up for examination, cleaning all parts and providing fresh lubricant to bearing/bush (oil or grease required) fixing the fan in position after assembling and adjustment for proper running including replacing of cable PVC copper flexible of size 23/0.0076 three core from ceiling rose to fan and other parts if required including testing for smooth running as specified. Note:- Cost of bearings, bushes, capacitors and other spares etc shall be measured and paid for separately as supply only. |
| 59 | Description all as per Ser item No 58.00 here-in-before but exhaust fan450/300mm sweep complete all as specified and directed. |
| 60 | Supply only capacitor 2.5 mfd to 3.15 mfddry typewith PVC clampmakeof capacity Epcos/Unistar/Usha complete all as specified and directed at site. |
| 61 | Supply only of rubber bush complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm sweep complete all as specified and directed at site. |
| 62 | Dismantling carefully ceiling fans (any make) of 1200mm sweep for cutting down & removing old copper winding wire and M&L forrewinding the same with new super enameled copper wire of suitable sizeincluding providing insulation by varnishing, oiling and greasingcomplete all as specified and directed. Note: If winding fan found unserviceable in a month contractor repair the same with out any cost. |
| 63 | Taking out complete windings, bearings/bushes, papers, tapes, flexible wire, shaft, check nut, frame of exhaust fan of size 300/380/450mm AC 230volts, 50 Hz 900/1400 RPM and M&L forrewinding with insulated copper windings wire of suitable sizeand replacement of bushes, bearings, tubes, papers, shafts, check nuts, bolts and nuts, capacitors, twin core copper wire, greasing, varnishing assembling and testing complete all as specified and directed. Note Cost of bearings, bushes, capacitors and other spares, if provided shall be measured and paid for separately under respective item of this schedule as supply only.Note: If winding fan found unserviceable in a month contractor repair the same with out any cost. |
| 64 | S&F in replacement of shaft for ceiling fan of any sweep and fixing in position for smooth functioning of ceiling fancomplete all as specified and directed. |
| 65 | S&F in replacement of rotor for ceiling fan of any sweep and fixing in position for smooth functioning of ceiling fancomplete all as specified and directed. |
| 66 | S& F in Replacement of body cover for ceiling fans of any sweep and make and fixing in position complete all as specified and directed. |
| 67 | S& F in Replacement of PVC canopy for ceiling fans of any sweep and make and fixing in position complete all as specified and directed. |
| 68 | Supply only of ball bearing. Make NBC/SKF, TATA for exhaust fan upto 450/300 mm sweep complete all as specified & directed. |
| 69 | Supply onlyof blades of ceiling fan of any sweep & make complete all as specified and directed. |
| 70 | Supply only of capacitor 4 to 6 mfd for exhaust fan complete all as specified and directed. Make: USHA, Shriram, Unistar/Epcos. |
| 71 | Supply only of ball bearing . MakeNBC, SKF, TATA for ceiling fan 1200mm sweep complete all as specified & directed. |
| 72 | S&F in replacement Wall mounting Fan 400 mm sweep, 230volts, fixed on wall with suitable size nut, bolts and washerscomplete all as specified and directed. |
| 73 | Supply only bush gun metal to match the ceiling fan of size 1200mm sweep complete all as specified & directed. |
| 74 | S&F in replacement PVC air fresh air Fan 250 mm sweep, 230volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed. |
| 75 | Machining work in body of ceiling fan by taking out worn out bush, boring hole to accommodate ball bearings complete all as specified and directed. |
| 76 | S&F in replacementMS down rod of 15mm (length upto 3 feet) dia suitable for fan in any length including threading , drilling holes complete all as specified and directed. |
| 77 | Supply and fixing only blades of exhaust fan 380/300/450 mm of any make complete all as specified and directed. |
| 78 | S&F in replacement of hanging hook with washer, nut bolt with rubber packing complete all as specified & directed. |
| 79 | Painting of ceiling fan 1200 MM sweep with blade high gloss white super enameld paint with help of Spray Gun and making smooth surface and marking MES no.with Black Paint all as specified and directed. |
| 80 | Painting of Exhaust fan 300/450 MM sweep with high gloss black super enameld paint with help of Spray Gun and making smooth surface and marking MES no.with whitePaint all as specified and directed. |
| 81 | S&F of PCB plate suitable for BLDC type ceiling fan with multi layered circuit design include motor control driver IC, microcontroller, rectifiers, capacitors, resistors, voltage regulators, and surge protection components and designed to operate on 220V, 50 Hz single phase power supply and shall support fan speed control(remote/fan regulator) complete all as specified and directed. |