| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power, bell point ) complete, including fixture and fittings such as switches, bell push, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking creditand making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 2 | M&L for Point wiring concealed conduit type with 1.5 sqmm PVC insulated unsheathed and multi stranded copper conductor cable FRLS, in and including PVC conduit 20 mm bore having 2 mm wall thickness with all conduit accessories for one light /fan/buzzer/soket outlet point controlled by one switch including continuous 1.5 sqmm copper conductor, stranded (green colour as earth ,red as phase and black as neutral), PVC insulated unsheathed earth wire cable FRLS to common earth and connected to earth dolly to be terminated in and including suitable size module boxes alongwith modular cover plate for housing of module switches/sockets etc for the following, complete all as specified and directed :-Note :Unit rates quoted by contractor shall deemed to be included for cutting chases in walls and making good in cement morter (1:3) and finishing the surface to match with exisiting surface. |
| 3 | One light point/ceiling fan/exhaust fan/bell pointcontrolled by one 6 Amp one wayswitch and regulator |
| 4 | One 5 pin 5 Amps switch socket outlet pointon same board . |
| 5 | One5 pin 6 Amps switch socket outlet pointon independent board. |
| 6 | All as per item No. 2 here in before but 2.50 Sqmm copper conductor wiringwith 2.50 Sqmm copper conductor as earth continuity for 15 Amps socket out let on independent board. |
| 7 | Supply and fixswitch modular type single pole one way 6 Amps including suitable size of module cover with frame etc, complete all as specified & directed. |
| 8 | S&F module switch 1 way 16 A, 1 module, complete all as specified & directed. |
| 9 | S & F modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified & directed. |
| 10 | S&F modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified & directed. |
| 11 | S&Fbell push type button 1 wat 6 A,1 module, complete all as specified & directed. |
| 12 | Supply & fixingceiling rose, surface bakelite, 65 x 17 mm three terminals, complete all as specified and as directed |
| 13 | Supply & fixingbell, Ding Dong AC. 230 volts,single pole, complete all as specified & directed. |
| 14 | S&F Fan step regulator 120 W, four stepped ,2 module, complete all as specified & directed. |
| 15 | S&Flamp holder PVC/ Polycarbonate type with cord grip cap, insulated body, threaded dome pattern, suitable for pendant fittings, complete all as specified & directed. |
| 16 | S & F in replacement of existing light fitting with LED batten integratedchannel20 watt having input voltage AC90-300V, 50 Hz, 6500K ,polycarbonate housing with white acrylic covertube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector, complete all as specified and directed. |
| 17 | S & F in replacment of existing light fitting withLED batten integratedchannel10 watt having input voltage AC90-300V, 50 Hz, 6500K, polycarbonate housing with white acrylic covertube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector, complete all as specified and directed. |
| 18 | S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt lightfitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 19 | S&F in replacementexisting light fitting withbuilding security light fitting with LED TYPE 35 watt optic lenses with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 32 mm bore “light grade” brackets 1.5 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076, complete all as specified and directed. |
| 20 | S&F in replacementSheet metal enclosures factory made, (Double Door) for DBs, single pole and neutral, 240 volts, 8 waysfixedon walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, testing and commissioning, complete all as specified and directed. |
| 21 | S&F in replacementSheet metal enclosures factory made, (Double Door) for DBs, single pole and neutral, 240 volts, 4 waysfixedon walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, testing and commissioning, complete all as specified and directed. |
| 22 | S & F in replacementMCB single pole & Netural32 Amps230 Volts\"C\" series, 25KA , complete all as specified and directed. |
| 23 | S & F in replacement MCB\"s single pole 240 volts 6 to 32Amps 10 KA \"C\"series, complete all as specified and as directed. |
| 24 | M&L for Earthing in replacement complete with galvanized steel earth plate electrode 60cmx 60cmx6mmthick buried directly in ground (earth pit not less than 2.25mdeep below normal ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected to galvanized iron wire 4.0mm diaby means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore includingGI lightgrade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing oncompletion, all as specified and directed. |
| 25 | S & F in replacement of existing light fitting with LED batten integratedchannel20 watt having input voltage AC90-300V, 50 Hz , 6500K ,polycarbonate housing with white acrylic covertube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector, complete all as specified and directed. |
| 26 | S & F in replacment of existing light fitting withLED batten integratedchannel10 watt having input voltage AC90-300V, 50 Hz , 6500K ,polycarbonate housing with white acrylic covertube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed. |
| 27 | S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt lightfitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 28 | M & L Wiring for circuit/submain wiring alongwith warth wire with thefollowing sizes of FRLSHin PVC insulated copper conductor, single core cable in surface/recessed as requiredsize of 2 X 4 sq mm and 1 X 4 sq mm as earth wire, complete all as specified and directed. |
| 29 | M&L forconcealed sub main wiring in replacement with two single core FRLS, PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through in and including non metallic rigid PVC conduit 25mm bore(having 2mm wall thickness), medium grade, with conduit fittings concealed in wall/floors/roof etc including taking down of old submain wiring complete all as specified and directed. Note:-Two runs of 6 sqmm cable alongwith one run of 6 sqmm cable as earth wire & PVC conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates. |
| 30 | M & L for AC Box having Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 A,complete all as specified and directed. |
| 31 | Supply and fix in replacment ofLED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up to ceiling rose with three core 1.5 Sqmm flexible copper conductor, complete all as specified & directed. |
| 32 | Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc complete all as specified and directed. |
| 33 | M&L for brick work built in cement mortar (1:6) with sub calss B bricks old size bricks, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. |
| 34 | Taking down cement plaster (in patches) on brick or stonewall including raking out joints hanking for key scrubbing down with water complete all as specified and directed. |
| 35 | M&L for rendering 15 mm thick in cement mortar (1:4) on concrete or brick work surface fair surface, finishing surface even and smooth without using extra cement complete all as specified and directed. |
| 36 | M&L for rendering 15mm thick incement mortar 1:6 on brick/concrete surface, finish over andfair and even without using extra cement complete all as specified and directed. |
| 37 | M&L for preparing the new plastered surfaces and applying three coats of white lime washingon walls, complete all as specified and direcrted. |
| 38 | M&L providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping / benching of manhole including necessary formwork, complete all as specified and directed. |
| 39 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil soil, complete all as specified and directed. |
| 40 | All as per item No. 35 above but depth exceeding 1.5 m and not exceeding 3.0 m. |
| 41 | Returning filling in, including spreading, levelling watering and wall, ramming in layers not exceeding 25 cm (soft/loose soil), complete all as specified and directed. |
| 42 | Removing surplus spoil to a distance not exceeding 50 m depositing where directed at a level not exeeding 1.5 m above the starting point, complete all as specified and directed. |
| 43 | M&L for providing cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation, mass concrete, complete all as specified and directed. |
| 44 | Demolition/breaking up or down PVC /AC/CI/Cement drain pipe (SGSW) of any size, fixed in any position, complete all as specified and directed. |
| 45 | S&Freinforced cement concrete pipe 100 mm bore, class NP-2 laid in trenches and jointed, complete all as specified and directed. |
| 46 | All as per item No. 41 above but 150mm dia. |
| 47 | All as per item No 41 but 200 mm dia |
| 48 | M&L for 450mm bore dia reinforced cement concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed. |
| 49 | M & L for Providing cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates, as in bed for 100 mm bore pipes including packing under the hauching against the sides of pipes after they are laid and testing, complete all as specified and directed. |
| 50 | All as per item No. 45 above but 150mm dia. |
| 51 | All as per item No 45 above but 200mm dia |
| 52 | Demolition of cement concrete in floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed. |
| 53 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 including sand cushion 30mm thick, completeall as as specified and directed. |
| 54 | M&L for 75mm thick PCC 1:4:8 typeD-2 (using 40mm graded stone aggregate) as in sub base, complete all as as specified and directed. |
| 55 | M&L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as levelling course below tiles, complete all as specified and directed. |
| 56 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments in floors, complete all as specified and directed. |
| 57 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection, surfaces finished even and fair without using extra cement including provision of construction joints, complete all as specified and directed. |
| 58 | Dismantling cast iron work of any description, complete all as specified and directed. |
| 59 | Dismantling posts or struts (wood Steel or RCC) any section including taking down embeded portion in concrete and making good disturbed ground, complete all as specified and directed. |
| 60 | Dismantling fencing wire mesh any type, complete all as specified and directed. |
| 61 | M&L in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed wih 2mm dia barbs at 75mm spacing and stranining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. (each line wire to be measured), complete all as specified and directed. |
| 62 | All as per item No 57 here-in-before but restraining, resecuring only including making good staples etc. |
| 63 | M&L for exacation in post holes (or similar holes) each not exc 0.5 cum getting out andremoving surplus soil to a distence not exc 50m (soft/loose soil) and making good surface, complete all as specified and directed. |
| 64 | M&L for PCC work as in (1:3:6) type C-2 using 40mm graded stone aggregate in foundation filling & mass concrete for Post / Pillars etc, complete all as specified and directed. |
| 65 | S&F MS work as in fencing post and struts including cutting tops to shape as directed ,including imbeding in concrete and all necessary drilling holes, bolting or riveting, welding, notching for wire etc and similar work conforming to grade Fe-410 or Fe-310, complete all as specified and directed. |
| 66 | M&L for Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering doors, etc to be prepred for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running, also fasting and fixing complete. Fe 290 (Gde E-165), complete all as specified and directed. |
| 67 | Supply only chain link MS galvanised fencing, heavy zinc coated (Hot Dip) of 4mm nominal dia of wire and mesh of size 100mm x 100mm conforming to IS: 2721-2003 complete all as specified in clause 10.34 on page 214 & 215 of MES SSR - 2009, Part-I, complete all as specified and directed.Note :-The weight of the chain link fencing after arrival at site shall be ascertained by a Board of Officers to be detailed by the Accepting Officer before incorporation in the work. |
| 68 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. complete all as specified and directed. |
| 69 | S&F MS round bar 10mm dia and over cut to length bent to shapes requried including cranking bending etc conforming to IS grade Fe-410-W for tying wire mash/chain linked fencing, complete all as specified and directed. |
| 70 | S&F in repairs galvanised steel punched tape concertina coil 600mm diaand stretched for a length of 6Rm/coil having 50 Nos rounds per coil while fixing and fixed to angle iron binded with 3.15mm dia GI wire, complete all as specified and directed. |
| 71 | S&F MS screw bolts machine made with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut 5 to 10mm dia meter of neck exc 5cm but not exc 10cm long, complete all as specified and directed. |
| 72 | M&L for preparing of new steel surface of any description not otherwise described over 10cms width or girth and applying 2 coats of synthetic enamelpaint over a coat of red oxide primer, complete all as specified and as directed. |
| 73 | Demolition of reinforced cement concrete as in man hole cover slabs, beams, and similar work including cutting, reinformcement to faciliate demolition, complete all as specified and directed. |
| 74 | M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in manhole cover / slabs and placing in position and set in cement mortar (1:4), complete all as specified and directed. |
| 75 | M&L for mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming toFe 500 or Fe-550 as in steel reinforcement for concrete, complete all as specified and directed.Note :- Weight of binding wire shall not be considered for measurement and payment purpose. |
| 76 | M&L PCC 1:3:6 type C-2 in surface channel or drains including necessary form works, stops, moulds etc including demolition of concrete, complete all as specified and directed. |
| 77 | Cutting into existing man hole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B-1 smooth finished or reforming benching as required for 200mm internal dia of pipe, complete all as specified and directed. |
| 78 | S&F 110 mm dia PVC (SWR) pipes any length and in any position in trenches, floors or at wall (with clamps in wall), complete all as specified and directed. |
| 79 | All as per item No 74 above but75 mm dia pipe. |
| 80 | S&F PVC (SWR) bends 75 mm dia, complete all as specified and directed. |
| 81 | S&F PVC (SWR) bends 110 mm dia, complete all as specified and directed. |
| 82 | Taking down GI tubing and connection including removing to store of 15 mm dia, complete all as specified and directed. |
| 83 | All as per item No 78 above but 20 mm dia. |
| 84 | S&F 15 mm dia steel tubes medium grade galvanised with all fittings / fixturesconcealed in stone masonry walls and ceilings or laid in floors, complete all as specified and directed. |
| 85 | All as per item No 80 above but 20 mm dia. |
| 86 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises, complete all as specified and directed. |
| 87 | S&F Non-skid ceramic colured tiles to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm(square/rectangular) in floor etc set jointed in neat cement slurry and pointed in white or coloured cement to match the floor including 15 mm thick screed in cement mortar 1:6 as in floors to receieved floor tiles, complete all as specified and directed. |
| 88 | S&F Glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface including 10 mm thick rendering in cement mortar 1:4 on walls to receive wall tiles etc, complete all as specified and directed. |
| 89 | S&F in repairs vitreous china Wash Hand Basin, white, flat back size 550x400mm including cutting for and pinning in ends of bracket or erecting stand with and includingangle iron brackets, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, cast copper alloy capastan head C.P brass pillar tap fency type 01 No, 15mm bore, CP brass waste coupling 32mm dia, PVC waste pipe 32mm dia and PVC connection 600mm long, high pressure with PTMT nut, complete all as specified and directed. |
| 90 | S&F in repair cast iron floor trap of 75 mm dia, chromium plated grating including jointing to waste pipe with lead joints and fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate), complete all as specified and directed. |
| 91 | S&F in repairs, vitreous china squatting pan, \"Orissa’ pattern of size 580mm x 440mmwhite with integral foot rest and flush pipe incl provision of concrete bedding etc, complete all as specified and directed. |
| 92 | S&F in repairs PVC low level flushing cistern of cap 10 ltrs including PVC flush pipe for squatting pan fixed to wall completed with brackets and accessories including. GI flush pipe and making good to disturbed portion complete matching with existing surface and Making GI pipe connection, complete all as specified and directed. |
| 93 | S&F in repairs Chromium plated bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe any description, complete all as specified and directed. |
| 94 | S&F in repairs of 15 mm bore Stop valve/angle cock cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe, complete all as specified and directed. |
| 95 | M&L for removing the manhole cover (CI or RCC) opening any type of manhole rectangular/circular of depth not exceeding 3m, taking out liquid/sludge/solid contents from the manholes/sewage line of 100 mm dia pipe by Mechanical Pumping making it fully functional to the entire satisfaction of Engineer-in-Charge including removal of sludge / solid contents outside the Defence Land and re-fixing the manhole cover to its original position for 100mm bore pipe line, complete all as specified and as directed. Note : (i) Work shall be carried out in foul condition(ii) Sewage shall be removed in closed container.(iii) Length of pipeline shall be measured from centre to centre of manhole and cleaning of manholes is inclusive in cleaning of pipe line.(ii) Manhole of depth more than 3m shall be measured and paid under relevent item.(iv) Contractor has to provide all necessary safety gears & protective equipment to the labours engaged.(v) Wk will done only when one supervisor is present on site who will be responsible for ensuring safety of the labours engaged. |
| 96 | All as per item No. 91 above but 150 mm bore pipe line. |
| 97 | All as per item No. 91 above but 200 mm bore pipe line. |
| 98 | All as per item No. 91 above but 450 mm bore pipe line. |
| 99 | All as per item No. 91 above but 600 mm bore pipe line. |
| 100 | Bailing out (dewatering) of water, sewage (sullage), liquid, semi liquid and solid suspended contents and floating matters of filteration bed of grease traps by MECHANICAL PUMPING ONLYby plugging inlets as required, desludging and getting out mud/ sludge/ silt/clay/sand/grit etc and all other foreign organic and inorganic materials, from filteration bed and getting out muddy sludge, silt and all other foreign particle material, grass, bushes, vegetation etc.and removing outside Defence Land up to a distance of 1.5 KM deposited where directed in borrow pits and covering the buried pit with 15cm thick layer of earth/soil and re-fixing the cover to its original position all as directed by Engineer-in-Charge and making oxidation pond fully functional to the entire satisfaction of Engineer-in-Charge.Note:(i)Work shall be carried out in foul condition(ii) Sewage shall be removed in closed container.(iii) Length of pipeline shall be measured from centre to centre of manhole and cleaning of manholes is inclusive in cleaning of pipe line.(iv) Contractor has to provide all necessary safety gears & protective equipment to the labours engaged.(v) Wk will done only when one supervisor is present on site who will be responsible for ensuring safety of the labours engaged. |
| 101 | Bailing out (dewatering) of water, sewage (sullage), liquid, semi liquid and solid suspended contents and floating matters from the soakage well approximate size 5.00 metre dia & 10 metre depth by MECHANICAL PUMPING ONLY by plugging inlets as required; desludging and getting out mud/ sludge/ silt/clay/sand/grit etc and all other foreign organic and inorganic materialsand removing outside Defence Land up to a distance of 1.5 KM deposited where directed in borrow pits and covering the buried pit with 15cm thick layer of earth/soil and re-fixing the cover to its original position all as directed by Engineer-in-Charge.Note:(i)Work shall be carried out in foul condition(ii) Sewage shall be removed in closed container.(iii) Length of pipeline shall be measured from centre to centre of manhole and cleaning of manholes is inclusive in cleaning of pipe line.(iv) Contractor has to provide all necessary safety gears & protective equipment to the labours engaged.(v)Wk will done only when one supervisor is present on site who will be responsible for ensuring safety of the labours engaged. |
| 102 | Removing the manhole cover (CI or RCC) opening any type of manholes (depth more than 3 metres) rectangular / circular, septic tank, soakage well, sewage plants/sumpsof any size, depth and any capacity and bailing out (dewatering) of water, sewage (sludge), liquid, semi liquid and solid suspended contents and floating matters by MECHANICAL PUMPING ONLY by plugging inlets as required; desludgingand getting out mud/ sludge/ silt/clay/sand and all other foreign organic and inorganic materials and removing outside Defence Land up to a distance of 1.5 KM deposited where directed in borrow pits and covering the buried pit with 15cm thick layer of earth/soil and re-fixing the cover to its original position all as directed by Engineer-in-Charge and making sewage system such as septic tank, soakage well, sewage plants/sumps and manholes fully functional to the entire satisfaction of Engineer-in-Charge.Note: 1. Working shall be carried out in foul conditions.2. After dewatering, the sludge allowed to dry and solid contents shall only be measured for payment purpose as described in PS Clause No. 23.3. Sewage/ sludge shall be removed in closed container mounted on vehicle.4. Contractor has to provide all necessary safety gears & protective equipment to the labours engaged.5.Work shall be carried out as and when required.6.Wk will done only when one supervisor is present on site who will be responsible for ensuring safety of the labours engaged. |
| 103 | Cleaning of open drainof any size, depth and removed all mud/ sludge/ silt/clay/sand, all other foreign organic and inorganic materials, solid suspended contents and floating matters by mechanical pumping and removing the waste materials up to a distance of 1.5 KM deposited outside Defence Land, complete all as specified and directed. |
| 104 | M&L for Cleaning and desilting of manholes depth not exeeeding 1.50mtr by pumping out/removing liquid waste /sewage and plugging the ends sewer pipes of diverting the flow into drain if necessary removing silt,sludge etc spreading bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts,lighting arrangement face mask etc and removing the same(silt sludging & Other materials ) in leak proof treucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and cleanning the manholes with fresh water etc, compare all as specified and directed.Note :- Manhole cleaned under item No 74 shall not be measured under this item. |
| 105 | M&L for Cleaning amd desilting of manholes depthexeeeding 1.50mtr but not exceeding 3.00 mtr depthby pumping out/removing liquid waste /sewage and plugging the ends sewer pipes of diverting the flow into drain if necessary removing silt,sludge etc. sparking olaaching powder on the silt to avoid bad smell including all precautionary and safety bmeasures, such as safety belts,lighting arrangement face mask etc and removing the same(silt sludging & Other materials ) in leak proof treucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and cleanning the manholes with fresh water etc, compare all as specified and directed.Note :- Manhole cleaned under item No 74 shall not be measured under this item. |
| 106 | M& L for cleaning the chocked /blocked in AC/CI/PVC soil waste pipe upto 150 mm dia by removing, cleaning the pipe making good damaged cement joints of pipe in ground /to three floors, oomplete all as specified and directed. |
| 107 | M&L for cleaning the chocked /blocked EWC / IWC/ Urinal / Bathroom and kitchen sinkincluding gulley trap, nahani trap and removing of sludge /soil waste to a distance exe 100m and testing of same after cleaning, complete all as specified and directed. |
| 108 | M& L for cleaning the chocked /blocked in existing pipe line of any size and upto any length with mechnical nidlle type machine for removing of all sludgeupto any depthwith all precautiions for safetty measures, complete all as specified and directed. |
| 109 | M& L for soakage well excavation in any typeof soil, doundatiion in PCC 1:3:6, wall of honeycombed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM , RCC cover slab in M-25. interconnecting pipe of RCC/DWC complete filled with brick bat size 1.8m dia x 3.00 mtr effective depth complete all as specified as zonal specification with all precautiions for safetty measures, complete all as specified and directed. |
| 110 | Preparation of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smaoke soot, mould, moss and efflorescent salts trading oil and greasy spots; filling holes, crakes with wall care putty and applying one coat of cement paint, complete all as specified and directed. |
| 111 | Raking out joints /pointings to masonary or brick -work in single detached joints in cement mortorfor flashing etc, complete all as specified and directed. |
| 112 | Flush pointing in brick work (top and sides of drain) in cement mortar (1:3), complete all as specified and directed. |
| 113 | Complete removal of existing treatment on wall with wire brushing scrapping down smoke soot, mould, moss and efflorescent salts trading oil and greasy spots filling holes, cracks with care putty and Preparation of old decorated/painted surfaces of wall of any description and applying two coat of exterior acrylic emulsion paint in camouflage pattern (grey/light black ) or as approved by user using minimum 3 or 4 different approved tint/colour as approved by GE, complete all as specified and directed. |
| 114 | M&L preparing new wall surfaces,and applying two coats of exterior acrylic emulsion paint in camouflage pattern including priming coat, complete all as specified and directed. |
| 115 | Dismantling brick tiles or terracing tiles, single layer on roof, complete all as specified and directed. |
| 116 | Removing excavated material exc 250m but not exceeding 500mabove the starting point and depositing where directed, complete all as specified and directed. |
| 117 | Roughening surfaces of old/concrete floor by backing sweeping clean with iron brush and washing down with water etc, complete all as specified and directed |
| 118 | M & L for PCC 1:2:4 type B-1 using 20mm graded stoneaggregate as in roof kerbs, mudstops, rounded or chamfered on edges, complete all as specified and directed. |
| 119 | M&L for PCC padding average 50mm thick to be provided in slope PCC 1:2:4 type B-1 using 20mm graded aggregate, complete all as specified and directed. |
| 120 | M& L for wire brushing neat cement slurrywith 3kg of cement per sqm at top and bottom of base coat and cleaning top surfces, complete all as specified and directed. |
| 121 | M&L for 15 mm thick screed bed in cement mortar 1:4 as in roof mixing with WPC mixing with water proofing compound by 3% by weight of cement or as per manufacturers instructions, complete all asspecifiedand directed.Note :-Water proofing compound will be measured and paid seperately. |
| 122 | Supply only Integral waterproofing compound, complete all as specified and directed. |
| 123 | Preparation of roof top surfaces providing and applying single component elastic cold applied polyurethene modified acrylic roofing system ,co elastic technology (CET) based on modified polyurethene and fully fibre reinforced having sun Reflectivity index (SR) of 106on top of concrete roof surfaces all cracks upto 3mm at corner joints channel and parapets should be treated with crack seal . Applying three coats including one coat of primer of Shali urethene BTD/Sikalastic 560/smart care damp proof ultrahaving coverage @ min 0.75Kg/Sqmand dilution upto 10% and laying reinforced fibre net and applying two coats of shaliurethene BTD/Sikalastic 560/smart bcare damp proof ultra @ total consumption 2Kg/sqm in two coats for maintaining minimum dry film thickness 1.50mm and elongation at break of free film of approx 350% The material shall be applied with brush or rooller ,complete in all respect as per the direction of Engineer -in-Charge /Consultant (Note :6hrs interval between two coat will be maintain ) All auxillary and accessories involved during application should be supplied by single manufacturer as part of system, complete all as specified and directed.(i)The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing.(ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years . However contractor may deposit the FDR of same amount in favour of Ge . If contractor fail to rectify the defect pointed out during this period in writing , the defect shall be got rectified at contractor \"risk and cost\" and the payment shall be made from the amount ofkept reserved or by encashing the FDR deposited by the contractor as guarantee. the contractor\"s quoted rates for this item shall deemed to be inclussive of this aspect. |
| 124 | S&F in repairs vitreous china Wash Hand Basin, white, flat back size 550x400mm including cutting for and pinning in ends of bracket or erecting stand with and includingangle iron brackets, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, cast copper alloy capastan head C.P brass pillar tap fency type 01 No, 15mm bore, CP brass waste coupling 32mm dia, PVC waste pipe 32mm dia and PVC connection 600mm long, high pressure with PTMT nut, complete all as specified and directed. |
| 125 | Disconnecting existing tanks, setting a side (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same position, complete all as specified and directed. |
| 126 | Dismantling of GI sheet (corrugated or semi corrugated etc) sheets in roof coverings, complete all as specified and directed. |
| 127 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 128 | Demolition of stone slabs and tiles of any description or thickness in floor aprov etc, laid, bedded and pointed in any mortar and including removal of debrish & rubbish from the site, complete all as specified and directed. |
| 129 | M&L for 20-25mm thick machine cut kota stone slab flooring over 20mm thick cement screed base of cement mortar 1:6 laid and jointed with grey cement slury mixed with pigment to match the shad of slab including grinding and polishing 5mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 130 | All as per item No 125 but as in skirting /dado with 10 mm thick rendering in cement mortar 1:4. |
| 131 | M & L for maint of firing range of size approx 20 x 10 mtr upto aveage depth of 1 mtr is to be cleaned and removing soil to be passing through the mesh strainer with requisite size for seperation of solid particle and the separated particle will be deposited to the authority and remaining soil to be removingfrom site uptooutside of MoD area or as directed and refilling the same area with proper mixing of sand with saw dust in 1:1 ratio by mechanically or manualy with requisite labore or as per site, complete all as specified and directed. |
| 132 | M & L for positioning of filled sand bag (size of bag 50 kg filled with sand) all aorund the range as existing for the purpose to support to stagging soil upto minimum existing height, complete all as specified and directed. |
| 133 | Taking down shutters of any description esceeding 1.00 sqm but n exc 2.00 sqm each, complete all as specified and directed. |
| 134 | S&Ffactory made pressed steel frames made out from 1.25mm thick steel sheetfor doors of size 105x60 mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.and including treated with tar or coal tar black paint on steel surfaces in contact / embeded in concrete or masonary work including Filling hollow portion of frame with PCC 1:3:6 type C-1, complete all as specified and directed. |
| 135 | S & F factory made Plain, framed, panelled shutters, 35mm thick, 2nd class hard wood , plain, framed, panelled shutters (any number of panels), with panels of 9mm thick veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed. |
| 136 | S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 150mm and fixed, complete all as specified and directed. |
| 137 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 138 | S&F Aluminium anodised Cast type handle of 150mm size, complete all as specified and directed.. |
| 139 | S&F floor door stopperof aluminium alloy long anodized with hard drawn steel spring fixed length of cover plate 15 cm long, complete all as specified and directed.. |
| 140 | M&L for preparation of new wooden surfaves and applying 2 coats of synthetic enamel paint over a coat ofpink primeron new wooden surface of girth over 10 cm, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail