| 1 | Dismantaling asbestos cement sheets (corrugated, semi corrugatd) in roof coverings complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to wall , fixed self tapping screws complete all as specified and directed. |
| 3 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screwscomplete all as specified and directed. |
| 4 | Dismantling mild steel or wrought iron work in roof trusses,gratings etc and similar work complete all as specified and directed |
| 5 | M&lfor Dismatling timber scantling40 sqcm and abovein any position ,unframed work complete all as specified and directed |
| 6 | M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed. |
| 7 | M&L for Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified and directed |
| 8 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxideprimer, complete all as specified and directed. |
| 9 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 10 | S & F for Aluminiumanodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with s 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified size of main tee shall be :-(i)36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/Rm(ii)Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/Rm and (iii)Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/Rm |
| 11 | S&F 4 mm thick non asbestos fiber designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed in ceilingwith and including dusting of surface complete all as specified and directed |
| 12 | S&F in repairs 5mm thick hollow PVC Sheet wall Panelling (sand wiched between the longitudinal grid in PVC Sheet)any pattern fixing at site with PVC beading/fillet complete all as specified and directed |
| 13 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed |
| 14 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete all as specified and directed |
| 15 | M&L for old size brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified and directed |
| 16 | Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed. |
| 17 | M & Lfor applying 15 mm thick renderingin CM 1:4 on brick / concrete surfaces of external walls finished even and smooth without using extra cement, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately. |
| 18 | Supply only integral water proofing compound complete all as specified & directed. |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed. |
| 20 | M & L for 15 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, surface finishedeven & smooth with using extra cement complete all as specified and directed. |
| 21 | M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed |
| 22 | M&L for 2 mm thick applying a layer ofputtyon wall surfaces including cornics etc for proper levelling of plastercomplete all as specified and directed. |
| 23 | M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed. |
| 24 | M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of primer complete all as specified and directed. |
| 25 | Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed. |
| 26 | M&L for nominal mix concretes 1:2:4 type B-O(using 12.5 mm graded stone aggregates) as in paddingon roof finished even and fair without using extra cement complete all as specified and directed |
| 27 | Supplying and laying APP based modified water proofing polymeric membrane reinforced with non woven polyester fabric matt (weight not less than 150 gram/sqm) of minimum 3mm thick, weight not less than 3 Kg/sqm, laid over & including 15 mm thick rendering in cement mortar 1:4 on concrete surfaces, finished the surfaces even and smooth including mixing ofwater proofing compound @ 3% by weight of cement over a bituminous shalitex primer @ 0.30 Kg/sqm evenly over a coat of hot bitumen 85/25 @ 1.2 Kg/sqm. The membrane shall be unrolled and bonded completely to the substrate (with overlap of 100mm on the transverse direction and 75mm on longitudinal direction and sealed by thermos fused torch) andthe overlaps sealed / fused by thermos fused torch as per manufacturer instructions. A coat of non reflective bituminous aluminium paint @ 0.150 Kg/ Sqm, complete all as specified and as directedNote :- Water proofing compound shall be measured & paid separately under respective items of BOQ |
| 28 | M&L for sunken floor treatment as under:- (i) The sunken portion shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed, the defective portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage/ seepage/ dampness is eliminated.(ii) Demolition ofcement concrete of any description and in any position not otherwise specifically provided for in any type of filling in sunken portion & cleaned the sunken potion including vertical wall surface complete all as directed.(iii)Laying of 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3), 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.(iv) After laying sewage/ plumbing pipes with fixtures in position, 2 coats of OMIPLAS EP-101 epoxy compound shall be applied completeall as specified and directed.(v) Testing again of water tightness by ponding for 72 hours & rectifying defects if any till total elimination of defects complete all as specified and directed.(vi) M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using 40mm graded brick aggregate over the treated surface complete all as specified and directed.(vii) Provinding spouts of25mm dia GI pipe light grade projecting 450mm from clear outer suraface of wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water, including cutting holes and making good if needed complete all as specified and directed. |
| 29 | Demolition of cement concrete (unreinforced)in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed. |
| 31 | S&FVitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 15mm screed bed in CM 1:6 complete all as specified and directed. |
| 32 | S&FVitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 33 | S&FNon skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 15mm screed bed in CM 1:6 complete all as specified and directed. |
| 34 | S&FNon skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 35 | M & L for non skid ceramic coloured /printedtiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floorsetc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles, laid over screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed. |
| 36 | M & L for glazed ceramic coloured / printed tiles 450mm x 300mmX7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles,over rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting& vertical Tiles complete all as specified and as directed. |
| 37 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in mortar complete all as specified & directed. |
| 38 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 10mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed |
| 39 | M&L for pre-polished Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed base in CM (1:6)laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed |
| 40 | M & L for pre-polished Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement backing coat (1:4) and jointed with with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed |
| 41 | M&L for rough dressed sand stone slab flooring 25mm thick bedded and jointed in 10 mm thick cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and as directed |
| 42 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 43 | M&L for 75 mmthick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 44 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement to match the surace of tiles in foor/steps, over 15 mm thick screed bed or bedding layer in CM 1:6 complete as all specified and directed. |
| 45 | M&L for Sand filling under interlocking tiles or in foundations including watering and consolidation complete all as specified & directed |
| 46 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006of 60 mm thickness M-35 Grade with grey cement complete all as specified and as directed |
| 47 | M&L for Providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings,platform,kerbs etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 48 | S&F in repairs 15 mm dia CP brass chromium plated Central Hole Basin Mixer with Regular Spout with Popup Waste System with 450mm Long Braided Hoses fancy type with or without lettered \"Hot\" or \"Cold\" ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe complete all as specified and as directed |
| 49 | S&F in repairs 15 mm dia CP brass wall Mixer withfancy type with or without lettered \"Hot\" or \"Cold\" ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe complete all as specified and as directed |
| 50 | S&fin repairs CP Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf chromium plated bracket guard and railing 60cm long complete all as specified and as directed |
| 51 | S&F in repairs CP Corner Glass Shelf (with Bracket) complete all as specified & directed.. |
| 52 | S&F in repairsPVC Bath cabinet with mirror 18\"x22\"x4.25\" complete all as specified & directed. |
| 53 | S&F in repairsfor CP Health Faucet brass body with wall hook and one meter SS braided rubber hose pipe complete all as specified & directed. |
| 54 | S&F in repairs 20mm bore ballvalve/float valve, high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of 20mm dia (min wt 210 grms) complete all as specified and directed. |
| 55 | Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed |
| 56 | Supplying and laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified and directed. |
| 57 | S&F in repairs vitreous china wash down water closet pan (padestal pattern) with seat cover (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and as directed. |
| 58 | S&F in repairs Cast iron Traps 100 mmP or Swith long arm complete all as specified and as directed |
| 59 | S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of lowor high density of PVC, 32mm diaincluding brackets and connections to pipe complete all as specified and as directed. |
| 60 | S & F in repairs vitreous china wash basin, white flat back size 550X400 mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand, complete all as specified and as directed |
| 61 | S&F in repairs PVC connections 15mmdia , 450mm long, , withPTMT nuts& washers at both ends complete all as specified & directed. |
| 62 | S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed. |
| 63 | S&F in repairsAngle valve/stop valve, cast copper alloy, fancy type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and as directed |