| 1 | Taking down carefully existig copper/ alumn point wiring for light/ fan/ bell/ socket 5/15 Amp points complete withfitting and fixtures such as Switches, Sockets, Ceiling Rose, Lamp Holder and bracket fittings with Battens/ Conduits/ Wires and making good the disturbed surfaces of walls and roofs etc to match with existing surface complete all as specified and directed. |
| 2 | Taking down carefully unserviceable main switches and distribution boards (single phase or three phase) of any capacity with Isolators/ MCBs/ MCCBscomplete all as specified and directed. |
| 3 | Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as directed and specified |
| 4 | M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets and various sizes hylam sheets for mounting switch/ sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specifiedforfollowing :- (a)One light/ fan/ bell/ Bldg security light point controlled by one single pole one way switch. |
| 5 | All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the independentboard controlled by one single pole one way switch board complete all as specified and directed. |
| 6 | All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the same board controlled by one single pole one way switch board complete all as specified and directed. |
| 7 | All as per item No. 04 as above here-in-before but wiring with 2.5 sqmm copper cable and 2.5 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed. |
| 8 | All as per item No. 04 as above here-in-before but wiring with 4 sqmm copper cable and 4 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed. |
| 9 | All as per item No 04 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as speicifed and directed. (a) One light point/fan/bell point controlled by one single pole one way switch. |
| 10 | All as per item No - 05 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed. |
| 11 | All as per item No - 07 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed. |
| 12 | S&F switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 13 | S&F Bell push switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 14 | S&F Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 15 | S&F socket outlet flush type 3 pin 5 Amp ISI marked complete all as specified and directed. |
| 16 | S&F socket outlet flush type 2-in-1, multipurpose, 3 pin 5 Amp and 3 pin 15 Amp, 240 volts complete all as specified and directed. |
| 17 | S&F Ceiling rose surface type, 240 volts, 50 Hz,white in colour, bakelite 65 x 50mm, 3 terminals dulyISI marked complete all as specified and directed. |
| 18 | S&FLamp holder , 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. |
| 19 | S&F rotary Stepped type electronic fan regulator compatible for BLDC for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, white in colour, duly ISI marked complete all as specified and directed. |
| 20 | S&F in replacement switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 21 | S&F in replacement Bell push switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 22 | S&Fin replacement Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 23 | S&Fin replacement socket outlet flush type 3 pin 5 Amp ISI marked complete all as specified and directed. |
| 24 | S&Fin replacement socket outlet flush type 2-in-1, multipurpose, 3 pin 5 Amp and 3 pin 15 Amp, 240 volts complete all as specified and directed. |
| 25 | S&Fin replacement Switch Socket combination 2 in 1, 6 pin 5 Amps and 15 Amps flush type universal, 240 volts complete all as specified and directed. |
| 26 | S&F in replacement ceiling rose surface type, 240 volts, 50 Hz,white in colour, bakelite 65 x 50mm, 3 terminals dulyISI marked complete all as specified and directed. |
| 27 | S&F in replacement Lamp holder , 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. |
| 28 | S&Fin replacement rotary Stepped type electronic fan regulator compatible for BLDC for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, white in colour, duly ISI marked complete all as specified and directed. |
| 29 | S&F 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc complete all as specified and directed. |
| 30 | S&Fin replacement 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc complete all as specified and directed. |
| 31 | Refixing only LED tube light fitting any type any size in existing position, retrieved from taking down wiring all as specified and directed. |
| 32 | S&F LED bulb of 9 watt, B22 base, 6500K all as specified and directed. |
| 33 | S&F Door Bell Ding Dong single phase 240 volts, white in colour, duly ISI marked complete all as specified and directed. |
| 34 | S&F LED sleeky bldg security light (Lens) fitting toughened glass of 35 watts, 6000K, including suitable sizebracket bend to shape complete with nuts and bolts of suitable size, duly painted with two coats of synthetic enameled paint and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed. |
| 35 | S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S. sheet, powder coated, partly embedded in wall, IP-43 protection, VTPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of MCCBs/ MCBs, factory made and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 36 | S&F Factory made sheet metal enclosures double door type made out of CRCAM.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 8 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 37 | S&F Factory made sheet metal enclosures double door type made out of CRCAM.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 12 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed.Make: HPL/ havells/ Indoasian |
| 38 | S&F MCCB thermal based release adjustable type 4 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KAincluding testing, complete all as specified and as directed. |
| 39 | S&F MCB SPN, 40A-63A, 240 volts, 10KA, complete all as specified and directed. |
| 40 | S&F MCB SP, 6A-32 Amps, 240 volts, 10KA,complete all as specified and directed. |
| 41 | S&F MCB TPN 40 Amps 10 KA415 Volts, complete all as specified and directed. |
| 42 | S&F MCB TPN 63 Amps 10 KA415 Volts, complete all as specified and directed. |
| 43 | S&F Sub main wiring with two single core 2x6 sqmm PVC FRLS insulated and unsheathed stranded copper conductoralongwith PVC FRLS earth wire 6 sqmm drawn in 25 sqmm PVC rigid concealed conduit connected to main board complete all as specified and directed.Note : (Two number cable and one number earth wire shall measured together as unit length). |
| 44 | S&F Sub main wiring with two single core 2x6 sqmm PVC FRLS insulated and unsheathed stranded copper conductoralongwith PVC FRLS earth wire 6 sqmm drawn in existing steel/ PVC rigid conduit connected to main board complete all as specified and directed. Note : (Two number cable and one number earth wire shall measured together as unit length). |
| 45 | S&F in repair energy saving decorative wall mounting LED lamp fitting made out of poly corbonate including 1x9/10 watt LED retrofit bulb 220 V base B22 and making connections complete all as specified and directed. |
| 46 | S&F energy saving decorative ultra slim square profile wall mounting LED Lighting fixtures as mirror light made out of poly corbonate enviromental friendly with high output diffuser, 10 watt LED 6500K,220Vand making connections complete all as specified and directed by Engineer in charge. |
| 47 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires made of engineering plastic IP-65 for outdoor including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 48 | S&F in repair bakelite sheet hylam 3mm thick with white top fixed with cup washers with machine screws on existing switch board with including removing existing switch/ switch sockets/ bell push etc and refixing the same by making slots on new sheet complete all as specified & directed for MS box fo approx size 8\" x 5\" etc as inreapirs complete all as specified and directed. |
| 49 | All as per item No 48 but of size 11\"\" x 9\", complete all as specified and directed. |
| 50 | S&F in repair MS Shunken Box rectangularblock for mounting normal/modular switches, sockets, fan regulator etc of sizes 175mmx100mmx50mm, complete all as specified and directed. |
| 51 | All as per item No 50 but of size 200 x 150 x 50 mm, complete all as specified and directed. |
| 52 | S&F in repair PVC Shunken Box rectangularblock for mounting normal/modular switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of sizes 175mmx100mmx50mm, complete all as specified and directed. |
| 53 | All as per item No 52 but of size 200 x 150 x 50 mm, complete all as specified and directed. |
| 54 | S&F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connectionsone twin core cable flat or circular of 10 Sqmm, complete all as specified and directed. |
| 55 | S&F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of 16 Sqmm, complete all as specified and directed. |
| 56 | S&Fin repairsof sheet metal enclosures 230 V single pole and earth enclosure with two pin & earth plug with socketcomplete includingsingle pole MCB 20 Amps, complete all as specified and as directed. |
| 57 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS-13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH, complete all as specified and directed. |
| 58 | M&L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI meshcharcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2009, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 15mm dia from earth pit to main board including necessary pit 1:3:6 of RCC 1:2:4 type B1 re-inforced with 6mm MS bars centre to centre, 10mm dia handle, complete all as specified and as directed. |
| 59 | S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 4 core, PVC insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified and directed. |
| 60 | Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan, for laying of cable and getting out, complete all as specified and directed. |
| 61 | M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified and directed. (Excavation and earth work measuredseparately). Note- Punned down thickness shall be measured. |
| 62 | S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable, complete all as specified and directed. (Excavation and earth work measured separately). |
| 63 | Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and directed. |
| 64 | Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point, complete all as specified and directed. |
| 65 | S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/ walls, laid under floor/ road crossings, complete with and includingclamps socket & elbow etc, complete all as specified and directed. |
| 66 | Supply & fixing in repair Capacitor (ISI Marked) 2.5 mfdcomplete all as specified and directed by Engr-in-Charge. |
| 67 | Note: The work is of maintenance nature, minor repair shall be carried out and paid in relevant items irrespect of complete rewiring as directed |