| 1 | Taking down copper/aluminium point wiring ( light,fan, socket or power) complete,incl fixtures and fittings like swithes, ceiling rose, pendant, regulator, sockets, light fitting ( Mirror light,Bulk head,LED Panel 2\"\"x2\"\",security light,wall fitting,down light, Flood light,post top lantern)etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:- |
| 3 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 4 | One 6A socket point controlled by one switch on independent board |
| 5 | One 6A socket point controlled by one switch on same board |
| 6 | One light point controlled by two, two way switches. |
| 7 | All as per item No. 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 8 | All as per item No. 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent boardbut just below / above the existing socket points / DBs up to one meter distance in the same vertical plane, with cables 2.5sq. mmsize complete all as specified and directed. |
| 9 | All as per item No 2 above here in before but wiring in casing caping for the following :- |
| 10 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 11 | One 6A socket point controlled by one switch on independent board |
| 12 | One 6A socket point controlled by one switch on same board |
| 13 | One light point controlled by two, two way switches. |
| 14 | All as per item No. 5.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed. |
| 15 | M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 16 | 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) |
| 17 | 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 18 | Notes for item No. 1.00 to 7-00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure.(iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion. |
| 19 | Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hzcomplete all as specified and directed. |
| 20 | Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hzcomplete all as specified and directed. |
| 21 | Supply and fix in replacement of Modular switch 2 way 6A, 1 module 240V, 50Hz complete all as specified and directed. |
| 22 | Supply and fix in replacement of Modular Bell push 6A 1 module, 240V, 50Hz complete all as specified and directed. |
| 23 | Supply and fix in replacement of electric call bell ding dong type, AC, 240V, 50Hz complete all as specified and directed. |
| 24 | Supply and fix in replacement of Modular Socket,6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 25 | Supply and fix in replacement of Modular Socket6A/16A - 2/3 pin combined 2 module 240V, 50Hzcomplete all as specified and directed. |
| 26 | Supply and fix in replacement of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed. |
| 27 | Supply and fix in replacement of Modular blank plate 1 module complete all as specified. |
| 28 | Supply and fix in replacement ceiling rose in poly carbonate 3 terminal brass, flush type 6 Amps, 220 volts AC, ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified. |
| 29 | Supply and fix in replacement of Lamp holder, angle type with metal ring, PVC/Polycarbonate body type B-22 with back plate, including LED bulb 12 watts complete all as specified. |
| 30 | Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified. |
| 31 | Supply and fix in replacement of old unserviceable LED mirror light light fitting Integral slim LED batten Integral 9 / 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 32 | Supply and fix in replacement of recessed mounted LED panel light 2\"x2\" size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 33 | Supply and fix in replacement Decorative wall light fitting, made out of polycarbonate suitable for B-22 base LED lamp including 10 watts LED lamp, full white of approved model fixed on wall and making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified.Make : Havell model No - CITY-1, LHDL02160099 or equivalent model in Wipro / Crompton / Philips. |
| 34 | Supply and fix in replacement ofLED bulkhead luminaire 10watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit with diffuser, including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 35 | Supply and fix in replacement of sleek round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser 3 in 1 wave colour changing LED light or warm / full white as per site requirement with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 36 | Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser, Aurora Plus lights. 3-in-1 color modes complete all as specified and directed. |
| 37 | Supply and fix in replacement of ventilating / PVC exhaust fans fancy square type 300mm sweep with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed. |
| 38 | All as per item No- 26 above but of size 250 mm complete all as specified and directed. |
| 39 | All as per item No- 26 above but of size 200 mm complete all as specified and directed. |
| 40 | All as per item No- 26 above but of size 100/150mm complete all as specified and directed. |
| 41 | Supply and fix LED Post Top Lantern light fitting 35/40 watt capacity new generation, energy saving, environmental friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium landscape IP65luminaire with high power CoB LED as light source and fixing arrangement on aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish compatible for all post top range 3.5 Mtr long mm duly grouted on wall/brick pillar with the help of cement mortar including making electrical connection with PVC insulated and PVC sheathed twisted three core wire of size 1.5 sqmm complete all as specified and directed at site.Make : Havells Model : ENDURASPRING6PT35WLED740PSYMTOTG (for light) and Make : Havells Model : 3.5MPOLE, HNS code 7308 (for pole) or equivalent model &make of Bajaj/ Philips/ crompton/ wipro. |
| 42 | Supply and fix in replacement of old unserviceable Post Top lantern light fitting of capacity 1x7/8 watts, gate light in aluminum die cast with modern artistic design and white PC diffuser suitable with B-22 base LED bulb and fixing arrangement on new GI pipe of 20/25mm dia medium grade duly grouted on ground/wall/brick pillar with the help of cement mortar including making electrical connection with pvc insulated and pvc sheathed twisted three core wire of size 0.5 sqmm fromjunction box to light fitting complete all as specified and directed.Make : Havells, Model No : LHFOASE1TN5W009 or equivalent model in Havells/ Philips/ crompton. |
| 43 | Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified. |
| 44 | Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately. |
| 45 | Supply and fix in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 46 | All as per item No. 34 here-in-before but SPN, 12 way, 230 V, 1 phase, AC complete all as specified and directed.Note:MCBs shall be measured and paid separately. |
| 47 | All as per item No. 34 here-in-before but SPN, 8 way, 230 V, 1 phase, AC complete all as specified and directed. Note:MCBs shall be measured and paid separately. |
| 48 | All as per item No. 34 here-in-before but SPN, 4 way, 230 V, 1 phase, AC complete all as specified and directed. Note:MCBs shall be measured and paid separately. |
| 49 | Supply and fix MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed. |
| 50 | Supply and fix in replacement of MCB 63A, 10 KA, TPN,\"C\" curve, 415 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 51 | Supply and fix in replacement of MCB 40A, 10 KA, SPN, \"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 52 | Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, \"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 53 | M&L in replacement of unserviceable Bus-bar chamber made out of sheet metal enclosure 100 Amps power coated independent for five connections, copper busbar suitable for 100 amps current rating mounted on wall, including connecting all incoming and out going electrical connections complete all as specified and directed . |
| 54 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter).The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity (Size:270 x 40 200mm) complete all as specified and directed. |
| 55 | Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated multi-stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 56 | All as per item No 44 but of size 10 sqmm 4 core complete all as specified and directed. |
| 57 | Material and labour for Double wall corrugated HDPE pipe, PN-10 ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed. |
| 58 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed. |
| 59 | Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 60 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 61 | Supply and fix in replacement of old unserviceable twin core of flexible wire of size 23/76 with PVC medium grade pipe 20mm dia for connection of post top lantern fitting from one junction box to other junction box complete all as specified and directed at site. |
| 62 | M&Lfor cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items. |
| 63 | Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 9\" X 11\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed.Note: S&F of switches, sockets & regulators shall be measured and paid separately. |
| 64 | All as per item No- 52 above but of size 8\" X 5\" complete all as specified and directed. |
| 65 | All as per item No- 52 above but of size 5\" X 5\" complete all as specified and directed. |
| 66 | S &Fswitch piano flush type polycarbonate single pole one way 6 Amps, ISI marked complete all as specified and directed. |
| 67 | S &Fswitch piano flush type polycarbonate single pole one way 16 Amps, ISI marked complete all as specified and directed. |
| 68 | S &Fsocket outlet polycarbonate 2 in 1, 3 pin, 6 Amps flush type complete all as specified and directed. |
| 69 | S &Fsocket outlet polycarbonate 2 in 1, 3 pin 6/16 Amps flush type complete all as specified and directed. |
| 70 | S &Fbell push flush type 6 Amps complete all as specified and directed. |
| 71 | S &FBell electric Ding-ding working on single phase 230 Volts AC Supply complete all as specified and directed. |
| 72 | S &FBatten Holder, B-22 base, PVC body complete all as specified and directed. |
| 73 | S &FElectronic Fan regulator, socket type, 5 steps working on single phase 230 Volts AC Supply complete all as specified and directed. |