| 1 | Taking down of Old unserviceable point wiring any type for light, fan, power etc includingunserviceable switch,socket, regulator light fitting and ceiling rose etc of any make complete including making good disturbed surfaces of walls ,floors roof etc complete all as specified and directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathedin and includingPVC concealed connduitincluding cutting chasing for conduitsand terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings for one light/Fan/Exhaust Fan/bell point complete all as specified and directed. |
| 3 | All description as per srl item No 2 here- in- before but using cable size 1.5 Sqmm for 1 No 05 Amps Socket outlet independentwith terminal boxes, Moduler fittings complete all as specified and directed. |
| 4 | All description as per srl item No 2 here- in- before but using cable size 1.5 Sqmm for 1 No 05 Amps Socket outlet on the same board with other switches complete all as specified and directed. |
| 5 | Allas per srl item No 2 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outletterminal boxes for Modular switcheswith 2.5 sqmm earth wire complete all as specified and directed. |
| 6 | M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathedin existing connduitincluding cutting chasing for conduitsand terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed. |
| 7 | All description as per srl item No 6.00 here- in- before but using cable size 1.5 Sqmm for 1 No 05 Amps Socket outlet independentwith terminal boxes complete all as specified and directed. |
| 8 | Allas per srl item No 6.00 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outletterminal boxes for Modular switches with 2.5 sqmm earth wire complete all as specified and directed. |
| 9 | M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathedin PVC casing & caping double lockincluding fixuresand terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings complete all as specified and as directed. |
| 10 | All description as per srl item No 9.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independentwith terminal boxes, Moduler fittings complete all as specified and directed. |
| 11 | Allas per srl item No 9.00 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outletterminal boxes for Modular switches with 2.5 sqmm earth wire complete all as specified and directed. |
| 12 | S&F in replacement of Plug Top 3 Pin 16 Amps with Indicatorcomplete all as specified and directed. |
| 13 | S&Fmodular switch 6 Amp single pole one way-1 module (Cat Part No W26401A Honeywell) complete all as specified and directed. |
| 14 | S&Fmodular switch 6 Amp single pole one way-1 module (Cat Part No 673000 of legrand) complete all as specified and directed. |
| 15 | S&Fmodular switch 6 Amp single pole one way-1 module (Make Cat Part No 21011 of Anchor Roma) complete all as specified and directed. |
| 16 | S&Fmodular switch 16 Amp single pole one way-1 module (Cat Part No W26411A Honeywell) complete all as specified and directed. |
| 17 | S&Fmodular switch 16 Amp single pole one way-1 module (Make Cat part No 673008 of Legrand) complete all as specified and directed. |
| 18 | S&Fmodular switch 16 Amp single pole one way-1 module (Make Cat Part No 21066 of Anchor Roma) complete all as specified and directed. |
| 19 | S&Fmodular socket outletshuttered-6A-2/3Pin-universal Indian2 Module complete. (Cat Part No W26428 of Honeywell)complete all as specified and directed. |
| 20 | S&Fmodular socket outletshuttered-6A-2/3Pin-universal Indian2 Module complete. (Make Cat part No 673044 of Legrand) complete all as specified and directed. |
| 21 | S&Fmodular socket outletshuttered-6A-2/3Pin-universal Indian2 Module complete. (Make Cat Part No 30373 of Anhor Roma) complete all as specified and directed. |
| 22 | S&Fmodular socket outletshuttered-16/6A-2/3Pin Indian 2 Module complete. (Cat part No W26424 of Honeywell) complete all as specified and directed. |
| 23 | S&Fmodular socket outletshuttered-16/6A-2/3Pin Indian 2 Module complete. (Make Cat Part No 673045 of Legrand) complete all as specified and directed. |
| 24 | S&Fmodular socket outletshuttered-20/6A-2/3Pin Indian 2 Module complete. (Make Cat part No 30828 of Anchor Roma) complete all as specified and directed. |
| 25 | S&F Fan step regulator 120W - 2 module (Make Cat part No 673029 of make Legrand) complete all as specified and directed. |
| 26 | S&F Fan step regulator 120W - 1 module (Make Cat part No 633027 of make Legrand) complete all as specified and directed. |
| 27 | S&F Fan step regulator 120W - 1 module (Make Cat part No W26473 of make Honeywell) complete all as specified and directed. |
| 28 | S&F Fan step regulator 120W - 2 module (Make Cat part No W26474 of make Honeywell) complete all as specified and directed. |
| 29 | M&L for Modular Bell push 6 Amp 2 Module (Make Cat Part No 673022 of Legrand) complete all as specified and directed. |
| 30 | M&L for Modular Bell push 6 Amp 2 Module (Make Cat Part No W26404BNA of Honeywell) complete all as specified and directed. |
| 31 | M&L for Modular Bell push 6 Amp 2 Module (Make Cat Part No21496 of Anchor Roma) complete all as specified and directed. |
| 32 | M&L in replacement of Bell ding dongAC 230Volts complete all as specified and directed. |
| 33 | S&F in replacement of switch piano type flush type single pole one way 5 Amps complete all as specified and directed. |
| 34 | S&F in replacement of socket outlet 2 in one 3 Pin5 Amps complete all as specified and directed. |
| 35 | S&F in replacement of switch piano type flush type single pole one way 16 Amps complete all as specified and directed. |
| 36 | S&F in replacement of socket outlet 2 in one 3 Pin5& 15 Amps complete all as specified and directed. |
| 37 | S&F in replacenent of PVC connection 600mm long with brass Nutwith rubber washer suitable hot/cold water complete all as specified and directed. |
| 38 | Supply and fixDown Rod with connecting accessories suitable for ceiling fan of sweep 1200/1400lengh 75 cm all as specified and directed |
| 39 | Supply and fixBall Bearing No 6201 to 6204 as required suitable for ceiling fan of sweep 1200/1400 complete all as specified and directed. |
| 40 | Supply and fixceiling fan hanging hook clamps (for fixing to ceiling fan rod) made with using GI of suitable sizewith heavy duty rubber insulator and two Nos nuts and one bolts including split pin complete all as directed by Engr-in-Charge. |
| 41 | Supply and fixheavy duty rubber insulator for 1200/1400 mm sweep for hanging ceiling fan.complete all as specified and directed |
| 42 | Supply and fix capacitor 2.5 to 3.15 MFD as per existing capacity of 240 volts AC complete all as specified and directed. |
| 43 | Supply and fixheating element any type as per site requirement of capacity 2 KW(Traingular/cup/box type as reqd) complete all as specified and directed. |
| 44 | Supply and fixthermostat for geyser as per site requirement temp setting on 60 degree Centigradecomplete all as specified and directed. |
| 45 | Supply and fixLED indication lamp Green/Red as reqd suaitable for Water Storage Geyser complete all as specified and directed. |
| 46 | Supply and fixflange assembly (Syphon) for 25 ltrs capacity of geyser and any type of hole (6 no) all complete with safety valvesas per existing make & size as per size requirement complete all as specified & directed. |
| 47 | Supply and fixsurface mounting PVCgang box of super qualityfor threeswitches withtwo /four holes complete all as specified and directed. |
| 48 | Supply and fixsurface mounting PVC gang box of super qualityfor five to seven switches withtwo /four holes complete all as specified and directed. |
| 49 | Supply and fixin replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 9 x 6inch complete all as specified and directed. |
| 50 | Supply and fixin replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 5 x 5 inch complete all as specified and directed. |
| 51 | Supply and fixin replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 8 x 5 inch complete all as specified and directed. |
| 52 | Supply and fixin replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 9x 11 inch complete all as specified and directed. |
| 53 | Supply and fixMetal Plug , 240V,20 A,2P+E suitable for Geyser\"s DB Enclosureall as specified and directed. |
| 54 | Supply and fixMetal Socket , 240V,20 A,2P+E with blue cap suitable for Geyser\"s DB Enclosureall as specified and directed. |
| 55 | Supply and fixPVC insulation tap of width 20 mm and length 10 Mtr complete all as specified and directed. |
| 56 | Supply and fixsaddle PVC nail type for fixing of PVC batton complete all as specified and directed. |
| 57 | Supply and fixFASTNER , 100 mm long,8mm dia complete set with nuts & washers as specified & directed. |
| 58 | Supply and fixnylone sleeve, SIZE 50MM complete all as specified and directed. |
| 59 | Supply and fixnylone sleeve, SIZE 35MM complete all as specified and directed. |
| 60 | Supply and fixMetal WoodScrew , size 50mm complete all as specified and directed. |
| 61 | Supply and fixMetal WoodScrew , size 35mm complete all as specified and directed. |
| 62 | Supply and fixin replacement super quality white flexible PVCpipe of25 mm dia, complete all as specified and directed. |
| 63 | Supply and fixCasing & caping 25mm width , complete all as specified and directed. make ; polycab,Akg,Kalinga |
| 64 | Supply and fixin replacement Brass machine screw of size 1 inch long complete all as specified and directed. |
| 65 | Supply and fixin replacement Brass machine screw of sice 2 inch long complete all as specified and directed. |
| 66 | Supply and fix1100 volt heavy duty weather proof cable wiyh PVC insulated stranded aluminium conductor,served with inner sheathing of PVC tape and overall PVC Sheathed of size 10 Sqmm x 2 core complete all as specified and directed. |
| 67 | Supply and fixPVC flexible wire two core twin twisted of size 23/0.0076 copper conductor all as specified and directed. |
| 68 | Supply and fix flexible copper cable , three core of size40/0.0060 with copper multistranded conductor PVC insulated complete all as specified and directed. |
| 69 | Supply and fix5 -in-1, 6 Amp,240V,SS Combined unit with box (surface type) with two fixing holes incl fixing rawal plug & screws complete all as specified and directed. |
| 70 | Supply and fix5 -in-1, 6/16 Amp,240V,SS Combined unit with box (surface type) with four fixing holes incl fixing rawal plug & screws complete all as specified and directed. |
| 71 | Supply and fixin replacement ceiling rose,three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed. |
| 72 | Supply and fixin replacement modular metal flush box of thickness 1.0 mm suitable for 12 modules 2 row complete all as specified and directed. |
| 73 | Supply and fixin replacement modular metal flush box of thickness 1.0 mm suitable for 8 modules 2 rowincluding making good the disturbed surface as specified and directed by Engr in Charge. |
| 74 | Supply and fixin replacement modular metal flush box of thickness 1.0 mm suitable for 6 modulesincluding making good the disturbed surface as specified and directed by Engr in Charge. |
| 75 | Supply and fixin replacement modular metal flush box of thickness 1.0 mm suitable for 3 modulesincluding making good the disturbed surface as specified and directed by Engr in Charge. |
| 76 | Supply and fixin replacement modular metal flush box of thickness 1.0 mm suitable for 2/1 modulesincluding making good the disturbed surface as specified and directed by Engr in Charge. |
| 77 | Supply and fixin replacement decorative polycarbonate modular white frame for fixing of switches and cover plate suitable for 12 modules 3 row and blanking plate if any required for spare module complete all as specified and directed. |
| 78 | All as per item No 77.00 here in before but 8 module single or double row as per site requirement complete all as directed by Engr in charge. |
| 79 | All as per item No 77.00 here in before but 6 module complete all as specified and directed. |
| 80 | All as per item No 77.00here in before but 3 module complete all as specified and directed. |
| 81 | All as per item No 77.00here in before but 1 or 2 module complete all as specified and directed. |
| 82 | Supply and fixDistribution box MCB Protected socket with Plastic enclosure (Surface mounting) 20 Amp MCB DB BOX Combo DP including Plug topall as specified and directed. |
| 83 | S&F for TP&N vertical load line DB double door with provision of MCCB as Incomer upto suitable 160 Amp, 415 volts 04 way, 50 Hz complete all as specified and directed by Engr-in-charge. (Note: The cost of MCCB & MCBs shall be measured and paid under separate item) |
| 84 | S&F for SP&N DB with 63 Amps rated bus bar, double door with 230 volts 8 way, 50 Hz complete all as specified and directed by Engr-in-charge. |
| 85 | Supply and fixMCB ,single pole 240 Volt,C curve 10 KA5 to 32 Ampscomplete all as specified and directed. |
| 86 | Supply and fixMCB, SPN, 240 Volt,C curve 10 KA , 20-32 Amps in existing DBs complete all as specified and directed. |
| 87 | Supply and fixMCB,SP,240 Volt,C curve 10 KA ,40 Amps complete all as specified and directed. |
| 88 | Supply and fixMCB ,DP, 240 Volt,C curve 10 KA, 40/63 Ampscomplete all as specified and directed. |
| 89 | Supply and fixMCB ,TPN,415 Volt,C curve 10 KA ,63Ampscomplete all as specified and directed. |
| 90 | Supply and fixin replacement tamper proofsingle phaseelectronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWHincluding cable connection, proper sealing with barcode with PVC seal.The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note:- Old unserviceable meter will be deposited to E/M store yard) |
| 91 | Supply and fixin replacement tamper proofthree phaseelectronic meters temper proof LCD display with polycarbonate cover 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWHincluding cable connection, proper sealing with barcode with PVC seal.The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note:- Old unserviceable meter will be deposited to E/M store yard). |
| 92 | Supply and fixin replacement of off load Change over switch with enclosure 4 Pole, 300 Amps, 415 V , complete all as specific and directed. |
| 93 | S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 94 | S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 95 | S&F in replacementLED 10 watt surface mounted downlightof size 125mm dia with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiencycomplete incl connection with 1.5 Sqmm 2 core flexible coppercable complete all as specified and directed. |
| 96 | S&F in replacementLED 15 watt surface mounted downlight of size 200mm diawith white powder coated polycarbonate housing and pressure die cast heat sink having high efficiencycompleteincl connection with 1.5 Sqmm 2 core flexible coppercable complete all as specified and directed. |
| 97 | S&F in replacement energy efficient LED light fitting surface mounted 4\" long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 98 | S&F sheet metal enclosure for DBs 16 Way single Pole and Neutral with acrylicdoor having 200 Amps ratedcopper bus bar 240 Volts AC complete all as specified and directed. |
| 99 | S&F sheet metal enclosure for DBs 12 Way single pole and neutral with acrylicdoor having 200 Amps ratedcopper bus bar 240 Volts AC complete all as specified and directed. |
| 100 | M&L forin replacement of sub main wiring2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulatedFRLSH multistranded copper conductor ISI marked 1100 V grade in existing PVC concealed conduit or fixed in wall/floor,passing through wall/ceiling complete. |
| 101 | M&L for in replacementof sub main wiring2x10 sqmm and 1x10 Sqmm earth wire PVC insulatedFRLSHmultistranded copper conductor ISI marked 1100 V grade in existing PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed. |
| 102 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover and Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces complete all as specified and directed. |
| 103 | M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where directed. |
| 104 | S&F in replacement MCCB of 04 pole 400 amp, TPN, 50 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed. |
| 105 | S&F in replacement MCCB of 04 pole 250 amp, TPN, 36 KA (Ics=Icu=100%)thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed. |
| 106 | S&F in replacement MCCB of 04 pole 160 amp, TPN, 25 KA (Ics=Icu=100%)thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed. |
| 107 | S&F in replacement MCCB of 04 pole 100 amp, TPN, 16 KA (Ics=Icu=100%)thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed. |
| 108 | S&F PVC conduit25mm dia \"medium grade\" including fittings/accessoriesconcealed in wall including cutting chasing and making good to disturb surfaces complete all as specified and directed. |
| 109 | S&F in replacement of PVC Sheathed copper cable 1.5 Sqmm 3 corecomplete all as specified and directed. |
| 110 | S&F in replacement of PVC Sheathed copper cable 2.5 Sqmm 3 corecomplete all as specified and directed. |
| 111 | S&F in replacement of modular cover plate with frame 3 module complete all as specified and directed. |
| 112 | S&F in replacement of modular cover plate with frame 6 module complete all as specified and directed. |
| 113 | S&F in replacement of capacitor 2.5mfdMfdincluding connectioncomplete all as specified and directed. |
| 114 | S&F in replacement of exhaust fan steel body 300mm dia having 04 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified and directed.Note : Old Fan will be deposite in MES store yard. |
| 115 | S&F in replacement of exhaust fan heavy duty steel body 450mm dia having 04 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified and directed.Note : Old Fan will be deposite in MES store yard. |
| 116 | S&F in replacement of exhaust fan PVC body 250mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified and directed.Note : Old Fan will be deposite in MES store yard. |
| 117 | S&F in replacement of exhaust fan PVC body 300mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified and directed.Note : Old Fan will be deposite in MES store yard. |
| 118 | M&L forin replacement of sub main wiring4x10 sqmm and 2x10 Sqmm earth wire PVC insulatedFRLSHmultistranded copper conductor ISI marked 1100 V grade in existing PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed. |
| 119 | Taking down old unserviceable ceiling fan and rewinding with super enamelled copper winding wire of existing gauge including varnish material and replacement of capacitor 2.5 mfdand painting of ceiling fan including fan blade and fixing the same in exising position and connecting with 1.5 Sqmm 3 core copper conductor cable complete all as specified and directed. |
| 120 | S&F in replacement of single pole with neutral and earth plug top and socket of capacity 20 Amps, 240 volts suitalbe for sheet metal enslousers with single pole complete all as specified and directed. |