Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for supplying and fixing in repairs a wall-mounted U-shaped powder-coated stainless steel handrail, size 600 × 100 mm, provided with hinge and all necessary fixing accessories. Complete all as specified and directed.Make/Model:Cera – Special Needs Range, Model No. 2506 or technocommercial equivalent make |
| 2 | Supply and fix in repair a powder-coated stainless steel foldable shower chair with backrest, size 465 × 315 mm, including all fixing fittings. Complete all as specified and directed.Make/Model:Cera – Special Needs Range, Model No. 2507 or technocommercial equivalent make |
| 3 | Supply and fix in repair a powder-coated stainless steel wall-mounted grab bar, 350 mm long, with all necessary installation hardware. Complete all as specified and directed.Make/Model:Cera – Special Needs Range, Model No. 2505 or technocommercial equivalent make |
| 4 | Supply and installation in repair of a hermetically sealed swing-type door, size 1800 × 2100 mm, constructed with SS304 sheet: Door SpecificationsDoor Leaf: 0.8 mm thick SS304 sheetDoor Frame: 1.2 mm thick SS304 sheetDoor designed to fit flush into wall panel system on both sides. Standard 50 mm panel with 100 mm frame width.Shutter to be 45 mm thick, PUF insulated (min. density 40 kg/m³) injected under high pressure.Accessories to be Included:(a)Stainless steel hinges – 3 Nos per leaf(b)Stainless steel ‘D’ type handles(c)Stainless steel push plates on push side(d)Standard arm door closer (TS-1002)(e)Tower bolt(f)View panel with self-adhesive tape and silicon sealant(g)One-side key-operated locking(h)Automatic door bottom sealComplete all as specified and directed. |
| 5 | Supply and fix in repair a two-bay stainless steel semi-automatic scrub station, size 1200 × 600 × 950 + 300 mm (L × W × H + flashback), floor-mounted, with sloppy radius chamber and two elbow-operated mixers having movable spouts for hot and cold water. Complete all as specified and directed. |
| 6 | Taking up or down steel tubing of the following bore, including dismantling of tiles, plaster or PCC with or without concealed pipe lines, along with all fittings and connections. Work includes cleaning the serviceable pipes and fittings for refixing or removal, and disposing of unserviceable debris outside MD land, complete all as specified and as directed. |
| 7 | 15mm bore |
| 8 | 20mm bore |
| 9 | 25 mm bore |
| 10 | 32mm bore |
| 11 | 40mm bore |
| 12 | 50 mm bore |
| 13 | 80 mm bore |
| 14 | 100 mm bore |
| 15 | Supply and fixing/laying of open or concealedas per site condition CPVC Pipes SDR 11 and plain CPVC SDR 11 fittings of following sizes including clamps and hookson wall / ceiling /or laying in floor, complete all as specified. |
| 16 | 15mm bore |
| 17 | 20mm bore |
| 18 | 25 mm bore |
| 19 | 32mm bore |
| 20 | 40mm bore |
| 21 | 50 mm bore |
| 22 | Supply and fix GI tubing of the following bore, medium grade, with all fittings, and fixed complete to walls, ceilings or laid in floors, complete all as specified and as directed. |
| 23 | 15mm bore |
| 24 | 20mm bore |
| 25 | 25 mm bore |
| 26 | 32mm bore |
| 27 | 40mm bore |
| 28 | 50 mm bore |
| 29 | 80 mm bore |
| 30 | 100 mm bore |
| 31 | All as per item No 8 but Refixing old GI tube,of followingbore, \"medium grade\" with all fittings and fixed complete to wall and ceiling or laid in floorsall as directed |
| 32 | 15mm bore |
| 33 | 20mm bore |
| 34 | 25 mm bore |
| 35 | 32mm bore |
| 36 | 40mm bore |
| 37 | 50 mm bore |
| 38 | 80 mm bore |
| 39 | 100 mm bore |
| 40 | S&F in repairs gun-metal globe valve or gate valve (ISI marked) with iron wheel head, screwed both ends for GI/CPVC pipe of the following sizes, complete all as specified and as directed. |
| 41 | 15mm bore |
| 42 | 20mm dia bore |
| 43 | 25mm dia bore |
| 44 | 32mm bore |
| 45 | 40mm bore |
| 46 | 50 mm bore |
| 47 | 80 mm bore |
| 48 | 100 mm bore |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat) and removingrubbish off the MD premises |
| 50 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor. |
| 51 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and rubbish off the premises.Note: The place of disposal shall be find out by the contractor. |
| 52 | M&L granite (of any type) slab 18-20 mm thickmirror polished machine cut in floors, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete andincluding20mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer In Charge |
| 53 | M&L granite (of any type) tiles 12 mm thick mirror polished machine cut, in skirting/ dado etc. vertical surfaces laid over cement screed, and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete andincluding10mm thick backing coat in CM (1:4)complete all as specified and as directed by Engineer In Charge |
| 54 | M&L Machine cut, mirror polished Kota stone slab flooring 22-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete andincluding20mm thick screed bed in CM(1:6)complete all as specified and as directed by Engineer In Charge |
| 55 | Ditto all as per item No 16 but in riser of steps, skirting, dado and pillar etc including 10mm thick backing coat in CM 1:4 complete as directed |
| 56 | M&L for Marble tiles, Makrana White, 20 mm thick, matching the existing pattern, machine-cut mirror polished, laid in floors, bedded, jointed and pointed with grey cement slurry, including cutting and polishing, and including 20 mm thick cement sand screed in CM 1:6, complete all as directed. |
| 57 | M&L for Marble tiles, Makrana White, 20 mm thick, matching the existing pattern, machine-cut, laid on vertical surfaces such as dado/skirting over cement screed, jointed and pointed with grey cement slurry, including cutting and polishing, and including 10 mm thick backing coat in CM 1:4, complete all as specified and directed by the Engineer-in-Charge. |
| 58 | M&L for 75 mm thick PCC Type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub-base, complete all as specified and directed. |
| 59 | M&L for rendering 15 mm thick on fair faces of brickwork or concrete surfaces of any description in CM 1:4, finished even and smooth without using extra cement, using Ready-Mix Plaster of Ultratech or equivalent, mixed with integral waterproofing compound, complete all as specified.(Note: WPC shall be measured and paid separately.) |
| 60 | Supply only integral water proofing compound of approved ISI make. |
| 61 | M&L preparing newly plasteredsurfaces of walls and applying two coats of Acrylic based exterior paint of required shade (two or more coat applied @ 1.67 ltr/10 sqm (100% Acrylic)over a coat of primer@ 2.2 kg/10sqm on wall surfaces. |
| 62 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement. |
| 63 | Material and labour for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of interior acrylic (100 % antifungal/antibacterial interior grade) paint over a coat of primer etc.complete all as specified and directed. |
| 64 | S&F in repair 8 mm thick, 600 × 600 mm size gypsum pre-laminated tiles for false ceiling fixed on aluminium anodized snap grid of size 605 × 605 mm with anodized aluminium angle 20 × 20 × 1.2 mm fixed to wall along the perimeter using nylon sleeves and screws at 610 mm centres.Main and cross tees of size 31.75 × 31.75 × 1.6 mm and 25.4 × 25.4 × 1.22 mm respectively. Ceiling cleats/angle brackets 15 × 15 × 1.5 mm, including 4 mm dia GI wire suspended from soffit at 1220 mm centres (max wire length 1200 mm), fixed to roof slab with 12 mm dia fancy-type steel anchor fastener with 80 mm hook, complete all as specified and directed. |
| 65 | S&F in repair 8 mm thick, 600 × 600 mm size gypsum pre-laminated tiles, conforming to IS 2095:1996 (Part-1), suitable for the existing anodised aluminium ceiling frame of the existing pattern, including taking down the existing ceiling tiles, refixing the existing grid where required, and providing additional GI hangers for proper support, complete all as specified and directed. |
| 66 | S&F in repair plain ceiling system consisting of 600 × 600 mm tiles, as per IS 2095:1996 (Part-1), made of 0.7 mm thick pre-coated galvanised aluminium in the required colour, laid ongrid system with 15 mm wide T-section flanges in matching colour having rotary stitching on the 1200 mm and 600 mm cross tees. The grid shall be of GI make with 15 mm wide T-section flanges having rotary stitching on all T-sections including the main runner, 1200 mm and 600 mm tees, each with a web height of 32 mm. The perimeter trim shall be Armstrong/Gyproc/equivalent, and wall angles of size 19 × 19 mm shall be fixed to the walls at centres not exceeding 450 mm. The work shall include all necessary fittings and providing 4 mm dia GI suspenders fixed to the slab using 12 mm dia fancy-type steel anchor fastener hooks, 80 mm long, complete all as specified and directed. |
| 67 | S&F in repairs 12 mm thick plywood, BWR grade, fixed with screws and provided with teakwood beading or aluminium beading as required, to wooden or aluminium framework, complete all as specified and directed. (New aluminium sections shall be measured and paid separately.) |
| 68 | M&L for 0.9 mm thick decorative laminate, Type 1, of approved surface finish, colour and pattern, fixed with approved adhesive strictly as per the manufacturer’s instructions, complete all as specified. |
| 69 | S&F in repairs 18 mm thick BWR grade plywood, fixed with screws, including fixing and polishing 4 mm thick teakwood beading to exposed edges as required, as in cupboards, shutters and similar works, including all necessary fixing arrangements as directed by the Engineer-in-Charge. |
| 70 | S&F 10 mm thick toughened glass for partitions, doors and similar works, including cutting to shape, drilling necessary holes and finishing as required, complete all as specified and directed by the Engineer-in-Charge. |
| 71 | Taking down old aluminium-framed windows, doors or partitions of any description, including removal of associated glass, plywood or particle board, from any position, complete all as specified and directed. |
| 72 | Supply & fixing in repairs powder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 73 | S&F plain sheet glass 4.80 mm to 5 mm thick, glazed with aluminium beading, glazing pins or oil putty, in panes not exceeding 0.5 sqm each, complete all as specified and directed. |
| 74 | S&F plain sheet glass 4.80 mm to 5 mm thick, glazed with aluminium beading, glazing pins or oil putty, in panes exceeding 0.5 sqm each, complete all as specified and directed. |
| 75 | S&F aluminium alloy wire mesh made of 0.45 mm nominal diameter wire with an average aperture width of 1.4 mm, fixed with aluminium wire staples and beading or U-section as required, complete all as specified and directed. |
| 76 | S&F in repairs anodised aluminium framework for doors, windows and ventilators, with one or more rebates, including jointing cleats, fixing arrangements and all necessary fittings, complete all as per existing pattern and as directed. |
| 77 | Supply and fix in repairs plain aluminium sheeting 0.71 mm thick, alloy 31000 H4, fixed to aluminium framework with rivets and necessary fittings, complete all as specified and directed. |
| 78 | Material and labour for preparing old plastered wall surfaces by washing, rubbing down and stopping, including complete removal of existing treatment, and applying two coats of acrylic antifungal interior-grade paint over one coat of primer, complete all as specified and directed. |
| 79 | Material and labour for preparing old plastered ceiling surfaces by washing, rubbing down and stopping, including complete removal of existing treatment or painted surfaces, and applying two coats of acrylic antifungal interior-grade paint over one coat of primer, complete all as specified and directed. |
| 80 | Material and labour for preparation of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth, including cleaning and priming, and applying one coat of antirust PU enamel paint, complete all as specified and directed. |
| 81 | M&L for mirror polishing to the existing stone flooring of any type to provide a high-gloss finish using machine polishing uniformly and evenly, including cleaning, debris removal, successive grades of abrasives and application of polishing compounds, complete all as specified and directed. |
| 82 | Supply and apply Ottoseal S-70 Premium silicone sealant (or equivalent) at junctions of windows on the external face, at skylight roofs and at wall–floor tile joints, ensuring proper joint preparation, masking and tooling for a neat finish, complete all as specified and directed. |
| 83 | M&L for vitrified ceramic tiles 600 × 600 × 8–10 mm of light colour (matt/nano finish or double charged), polished/glazed for floor finish, set on 20 mm cement–sand screed in CM 1:6, jointed and pointed with epoxy grout to match the flooring; joints to be 2 mm wide with 2 mm spacers at corners; tiles to be placed, grouted and finished true to level and alignment, complete all as specified and directed. |
| 84 | Material and labour for glazed/ polished ceramic tiles in vertical surfaces 600 x 300 x 8 to 10 mm thick (glossy/nano finish, double charged), set and jointed using tile adhesive (3-6 mm thick) and pointed in epoxy grout to match shade of tile including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.Note: both the substrates should be cleaned, spread the adhesive on plastered surface andcomb with a notched trowel and place the tile.Makes:(i) Tile adhesive : Dr fixit fevimate WMA or Roff new construction tile adhesive or equivalent make as specified in Appx \"B\" of PS hereinafter.(ii) Epoxy grout: Somany ezy grout or Dr fixit fevimate TG or equivalent make as specified |
| 85 | S&F 400 × 400 × 7–8 mm thick non-skid ceramic tiles of approved colour, set and jointed and pointed in coloured cement slurry in flooring, including 20 mm cement–sand screed in CM 1:6 and finishing true to falls and level, complete all as specified and directed. |
| 86 | S&F glazed ceramic coloured tiles 300 × 450 × 7 mm thick on vertical surfaces, set in neat cement slurry and pointed in coloured cement to match, including 10 mm thick backing coat in CM 1:4, finished true and plumb, complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for glass mosaic tiles (20–25 × 20–25 mm; tile thickness 3.8–4.3 mm; joint 1.6 mm) assembled in panels of 300 × 300 mm, fixed to rendered surfaces with approved adhesive, backing paper removed after setting, followed by washing and cleaning to expose finished joints, complete all as specified and directed. Make: Mridul or equivalent. |
| 88 | Demolition of brickwork or stone/boulder masonry built in cement mortar, including removal of all quoins, arches, pillars, shaft walls, crumpled edges and supports for water pipelines, including careful demolition of copings, and removal of debris outside MD land, complete all as specified. Note: The work shall be carried out on the roof of a G+6 storey building. |
| 89 | M&L for brickwork using subclass ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:4), complete all as specified. |
| 90 | M&L for brickwork using subclass ‘B’ old-size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6), including reinforcement with 10 mm dia MS round bars, 2 Nos, placed horizontally after every four courses of brickwork, complete all as specified and directed. |
| 91 | Chipping and carefully removing concrete including plaster surfaces using low-impact hammer/breaker without damaging the structure in parapet walls and other concrete surfaces, including cleaning and disposal of debris outside MD land, complete all as directed by the Engineer-in-Charge. Hard concrete shall not be removed by force and the premises shall be cleared of all rubbish.Note: The contractor shall identify and arrange the suitable place of disposal. |
| 92 | M&L for applying rust remover (alkaline in nature, specific gravity 1.1 kg/litre) to existing or additional rebars, including wire-brushing manually or with mechanical tools after cleaning the disturbed concrete surface and draining off water, complete all as specified. Rust remover shall be from one of the following makes: Fosroc / Sika / BASF / Krisha Conchem / Dr. Fixit / Pidilite. Note: Measurement shall be based on the area of concrete exposed. |
| 93 | M&L for applying two coats of anti-rust protective coating using acrylic polymer having minimum 40% solid content, mixed with cement in the ratio of 1:1.5 (1 part polymer: 1.5 parts cement), applied on rebars after thorough cleaning of rust scales as per manufacturer’s instructions, complete all as specified. Anti-rust coating shall be from the following makes: Fosroc / Sika / BASF / Krisha Conchem / Dr. Fixit / Pidilite. Note: Measurement shall be based on the area of concrete exposed. |
| 94 | M/L for TMT(CRS) bars 10mm dia. and over, Cut to length, bent to shape required including cranking, spirally and binding with MS wire (annealed) not less than 0.9mm dia.by placing in position new reinforcement bars including tack welding to existing reinforcement bars all complete as specified and as directed. |
| 95 | Providing bonding coat of SBR polymer over the exposed steel/welded mesh/concrete in ratio 1:1 to 1:1.5 of polymer and cement complete as directed by the consultant. SBR polymer to be procured from one of the manufacturer\"s given below. |
| 96 | M&L for repairing the damaged concrete portion by SBR Polymer with a minimum solid content to 40% cement mortar in proportion 1:5:15 i.e. (1 part SBR polymer : 5 parts OPC cement and and 15 parts of graded quartz aggregate (sand) upto 25mm thickness as directed by the manufacturer\"s instruction including necessary curing etc. complete all as specified & as directed.SBR polymer shall be procured from one of manufacturer given below. |
| 97 | M&L for injectingcement slurry grout in the ratio 1:2 (1-Cement 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. The damaged area of the slab is to be repaired using polymer plaster(POLYMER MODIFIED MORTAR) (1:5:15) 1 monobond 5 Cement-15 sand) –in damaged areas . nozzle to be fixed to the slab using epoxy grout.The work includes complete sealing of cracks, voids from both floor and ceilng(For repair to slab) |
| 98 | M & L for water proofing treatment of external walls by applying two coats of elastomeric external acrylic water proofing coating material after cleaning the surface thoroughly and sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications and directions of Consultant/Architect. Make :Build core STP chemicals or equivalent. complete all as specified & as directed by EIC. (Note :- work will be carred out with scafolding all over bldg upto G+6 th floor of wall. Rate of scaffoldingis included in this item). |
| 99 | M&L for taking out and removing vegetation growth or shrubs and injecting chemical Glyphosphate 41% SL, 20 ml or till refusal, by making cuts/injections in the stem of plants at 30 mm c/c, and spraying a solution prepared by diluting 25 ml Glyphosphate 41% in 1 litre of water, and removing the plants/vegetation completely once dead, including necessary scaffolding, jhulas etc., complete all as per the manufacturer’s instructions |
| 100 | Supply and fix in repair 2 mm thick coloured electrostatic conductive vinyl flooring having optimal and constant static-conductive properties, antifungal and antibacterial characteristics, laid on levelled floors using cementitious self-levelling compound, suitable adhesive and copper strip, including cord-welding of joints, sealing of joints between wall and floor with sealing compound, and removal of old flooring outside MD land, complete all as specified and directed. |
| 101 | M&L for wooden wall panelling made from 15 mm thick 1st-class hardwood boarding, termite-proof treated, planed on one side, edges tongued and grooved, panel width exceeding 10 cm and not exceeding 30 cm, fixed to aluminium framework using coloured screws, nails, beads and jambs or adhesive, complete all as specified. |
| 102 | M&L for preparation of new wooden surfaces of any description over 10 cm in width or girth, including sanding and surface preparation, and finishing with two coats of synthetic varnish over an undercoat of varnish and transparent liquid filler to achieve a fully shining finish, complete all as specified and directed by the Engineer-in-Charge. |
| 103 | M&L for providing PU sealant in expansion joints of width not exceeding 45 mm, including removal of old sealant, cleaning and preparing the joint, and sealing with approved polyurethane sealant and filler boards, complete all as specified and as directed. |
| 104 | Material and labour for filling crumple joints with non-bituminous PE foam filler boards complying with IS 1838, minimum 450 mm width, installed as per manufacturer’s instructions, including necessary scaffolding and all associated preparation and finishing works, complete all as specified and directed. |
| 105 | M&L for 10 mm thick interlocking laminated wooden flooring laid over 2 mm thick foam sheets/adhesive as per manufacturer’s instructions, including proper preparation and levelling of the base, filling depressions or holes with cement plaster in CM 1:3 to achieve true level, and providing matching skirting, complete all as specified and directed by the Engineer-in-Charge. Note: The colour and pattern of the tiles/planks shall be approved by the Engineer-in-Charge. |
| 106 | Taking down CI/PVC soil, waste, vent or rainwater pipes laid in trenches or fixed to walls, including pipes embedded or packed in PCC, and including removal of concealed rainwater pipes along with all connected fittings such as shoes, bends, swan necks, junctions etc. of any diameter, complete all as specified and directed. |
| 107 | S&F cast iron soil, waste and vent pipes and rainwater pipes of 100 mm bore, in any length, with or without ears, including necessary jointing such as cement joints, lead joints, red-lead putty or rust-cement joints, fixing to walls or laying in trenches, complete all as specified and directed. |
| 108 | S&F cast iron bends of 100 mm dia, including diminishing pieces or tapers, fixed in position complete all as specified and directed. |
| 109 | Supply & Fixing in repairs 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 110 | S&F bands, straps, supports or stays for rainwater and ventilating pipes, including bolts and similar small articles as required, conforming to Fe 290 Grade E-165, suitable for new or old pipes fixed in shafts up to a height of 35 RM, including necessary scaffolding, complete all as specified and directed. |
| 111 | Supply and fix in repair 100 mm dia Nahani trap with grating, including jointing with solvent cement and connection to the waste pipe, and fixing the trap in cement concrete type B–1 (1:2:4), complete all as specified and directed. |
| 112 | S&F stainless steel sink of overall size 680 mm × 530 mm × 215 mm, single bowl without drainage board, fabricated from 1.00 mm thick 304-grade stainless steel sheet, complete with plug, waste coupling, washers, waste pipe, CI cantilever brackets and connecting union to pipe, complete all as specified. |
| 113 | M&L for cutting holes in brickwork, PCC or RCC using a core cutter, and providing 40 mm dia PVC pipe as spout of required length, including making good the disturbed surface with waterproofing treatment, complete all as specified and directed. |
| 114 | Supply and fix in repair 15 mm bore bib cock with wall flange, complete all as specified and directed. |
| 115 | S&F in repair PVC pipe 40 mm dia fixed in any position and at any level as directed, duly concealed, joined up to the drain line including connection to the existing PVC waste pipe using elbows and tees, and including cutting and jointing to the existing drain line, complete all as specified and directed. |
| 116 | Supply and fix in repair 15 mm dia concealed stop cock with adjustable wall flange, complete all as specified and directed. |
| 117 | S&F in repair wash hand basin of vitreous china, white, flat-back type, 630 mm × 450 mm, including CI brackets, 32 mm dia CP waste coupling, cutting and pinning ends of brackets into wall, and connecting up supply pipes, waste pipes and taps, complete all as specified. |
| 118 | S&F in repair 15 mm dia PVC connector, of any required length, provided with CP brass nuts, and connected to waste water line 450 mm long, complete all as directed. |
| 119 | S&F in repair 15 mm dia pillar tap, CP brass, pressmatic/self-closing type, complete all as directed. |
| 120 | M&L in repairs cast iron floor trap 100 mm dia, with grating, including jointing to waste pipe and fixing in cement concrete type B-1 (1:2:4), complete all as specified and directed. |
| 121 | Treatment of sunken floor slab comprising the following: (i) M&L for demolition of existing floor tiles, sunken PCC and treatment layers, including cleaning the sunken or lowered portion of the RCC slab surface (including full vertical depth plus skirting height) by wire brushing, chiselling out all mortar sticking to the surface, and brooming clean; (ii) rendering of uneven surfaces with 15 mm thick cement mortar (1:4) mixed with integral waterproofing compound @ 3% by weight of cement consumed, filling with water and checking for dampness and seepage, and where dampness or seepage is observed, fixing nozzles and carrying out grouting, complete all as specified and directed. (Note: WPC shall be measured and paid separately.) |
| 122 | M&L for applying two coats of polymer-modified cementitious waterproof coating as per manufacturer’s instructions to the bottom and vertical sides of the sunken portion up to finished floor level plus 100 mm height, the total thickness of the two coats being 1 mm; when the second coat is still tacky, coarse sand shall be sprinkled on the bottom and vertical surfaces to provide a bonding key, complete all as specified and directed. |
| 123 | M&L for rendering the bottom and vertical sides of the sunken portion up to the bottom of skirting with a minimum 20 mm thick cement mortar 1:4 mixed with integral waterproofing compound, including rounding of corners and junctions and forming proper slopes towards the spout, finishing fair and even using extra cement on the sunken floor where required, complete all as specified and directed. Note: The waterproofed area shall be tested by ponding with water for at least 72 hours and checked for leakage or seepage to the entire satisfaction of the Engineer-in-Charge. |
| 124 | Material and labour for filling cement concrete 1:5:10 using coarse aggregate, laid, compacted and finished as directed, complete all as specified. |
| 125 | M&L for 40 mm dia CPVC pipe, medium grade, laid on sunken floors, including core cutting where required, proper packing of the pipe, and waterproofing grouting around the pipe, complete all as specified and directed. |
| 126 | Supply and fix in repair 15 mm bore cast copper alloy chromium-plated bib cock, auto-closing type, with built-in control cock, complete all as specified and directed. |
| 127 | Supply and fix in repair 15 mm bore angular stop cock with wall flange, complete all as specified and directed. |
| 128 | Supply and fix in repair 100 mm size overhead shower rose, round shape, single-flow type (ABS body), complete all as specified and directed. |
| 129 | Supply and fix in repairs chrome-finish soap dish, fixed with and including CP brass screws, complete all as specified and directed. |
| 130 | Supply and fix in repairs brass chromium plated tubular towel rail, 20 mm dia `D\" type, 60 cm long between flanges including CP brass screws and wooden/plastic cleats as required complete all as specified and directed. |
| 131 | Supply and fix in repair health faucet with flexible pipe(ABS Body) with 01 meter long PVC tube and wall hook complete all as specified and directed. Make: Jaquar Model No ALD CHR-583 or equivqlent in Crab Tree/Kohler or equivalent make as specified in Appx \"B\" of PS hereinafter. |
| 132 | Supply and fix two way bib tap 15mm dia complete all as specified and directed. |
| 133 | Supply and fix in repairs central hole basin mixer without popup waste system with 450mm long braided holes complete all as specified and directed. |
| 134 | Supply and fix in repairs table top ceramic wash hand basin coloured vitreous china oval shape and of size610x460x150mm. |
| 135 | Supply and fix in repair PVC valveless, syphonic action type, dual flushing cristern, low level, white, 10 ltr capacity with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 136 | Supply and fix in repair white vitreous china wash down water closet pedestal pattern size( EPWC)CI \"P\" or \"S\" trap including conn to drain pipe and flushing pipe,anti sy phonage pipe etccomplete all as specified and directed. |
| 137 | Supply and fix in repair vitreous china squatting including conn to drain pipe and flushing pipe,anti sy phonage pipe etc pan orissa pattern size 580 x 440mm white with integral foot rest complete all as specified and directed. |
| 138 | Supply and fix in repair white vitreous china urinal (full stall type) flat back, (same as existing) with cast iron hangers, 15 mm dia CP spreader, 32 mm dia CP brass domical white for connector to 32mm dia cast bottle trap including cutting and making good the wall and floors whereever required complete all as specified and directed. |
| 139 | Supply and fix in repair PVC waste pipe 32mm bore, 90cm long fixed with waste coupling including socket complete all as specified and directed. |
| 140 | Supply and fix in repair urinal partition of vitreous China white 310x700cm size tapering at bottom, 50mm thick to match existing pattern complete all as specified and directed. |
| 141 | Supply and fix in repair 6mm thick superior quality beveled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers size 600mm x 450 mm complete all as specified and directed. |
| 142 | Supply and fix surface-mount corner guard of wing size 76 mm with 1.78 mm thick continuous aluminium retainer, 2 mm thick vinyl cover, and top/bottom coloured caps as specified, of required height, fixed to walls with self-tapping screws, making good the surfaces disturbed, complete all as specified and directed. |
| 143 | Supply and fix in repair 3-layer PP-R pipes, SDR 7.4 (PN 16), UV-stabilised and anti-microbial, fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass-threaded fittings, fixed complete to walls, ceilings or floors, of 25 mm outer diameter, complete all as specified and directed. |
| 144 | Supply and fix in repair 3-layer PP-R pipes, SDR 7.4 (PN 16), UV-stabilised and anti-microbial, fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass-threaded fittings, fixed complete to walls, ceilings or floors, of 20 mm outer diameter, complete all as specified and directed. |
| 145 | Supply and fix in repair PP-R gate valve, brass insert type, with iron wheel head, ISI-marked, screwed at both ends for 25 mm OD PP-R pipes, complete all as specified and directed. |
| 146 | Supply and fix in repair PP-R gate valve, brass insert type, with iron wheel head, ISI-marked, screwed at both ends for 20 mm OD PP-R pipes, complete all as specified and directed. |
| 147 | S&F in repairs 15 mm bore Florentine Pillar Cock, cast copper alloy, chromium plated, with extended lever handle, complete all as specified. |
| 148 | S&F in repairs 15 mm bore Florentine Bib Cock with extended lever handle and wall flange, cast copper alloy, chromium plated, complete all as specified. |
| 149 | S&F in repairs stainless steel sink without drain board, fabricated from 1.00 mm thick 304-grade stainless steel sheet, complete with plug, washers, waste coupling, waste pipe, site-specific fixing arrangements and connecting union to pipe; overall size 610 × 460 mm and bowl size 560 × 410 × 215 mm, complete all as specified. |
| 150 | S&F in repairs stainless steel sink waste coupling, made of steel and plastic, of make Nirali / Diamond, complete all as specified. |
| 151 | S&F in repairs stainless steel grating, 1 mm thick, 125 mm diameter, glossy finish, complete all as directed. |
| 152 | S&F in repairs 32 mm dia brass CP waste coupling for wash hand basin, full or half thread type, complete all as specified. |
| 153 | S&F in repairs 40 mm dia brass CP waste coupling for wash hand basin, full or half thread type, complete all as specified. |
| 154 | SS&F in repairs urinal spreader, CP finish, any approved colour, suitable for fixing with 15 mm dia pipe, of minimum 60 g weight, complete all as specified. |
| 155 | M&L for cleaning the terrace, including opening damaged joints of cement concrete tiles or PCC, removing accumulated debris, algae and fungus, and preparing the surface by wire brushing and high-pressure water jet to ensure it is free from dust, oil, grease, loose particles and vegetation roots of any description and in any position; including removing accumulated material outside MD land with all necessary arrangements, and inserting cement slurry mixed with liquid waterproofing compound at the rate of 200 ml Dr Fixit Pidiproof LW per 50 kg cement through the opened joints of CC tiles or cracks in PCC on terrace, applied manually with a trowel to seal all joints and cracks, complete all as specified and directed by the Engineer-in-Charge. Note: The place of disposal shall be identified by the contractor. |
| 156 | M&L for cleaning the surface of existing APP membrane, including removal of accumulated debris, algae and fungus, and preparing the surface by high-pressure water jet to ensure it is free from dust, oil, grease, loose particles and vegetation roots of any description and in any position; including removing accumulated material outside MD land with all necessary arrangements, and sealing opened overlaps and voids of the APP membrane using thermo-fusion by LPG torch, and inserting cement slurry mixed with liquid waterproofing compound at the rate of 200 ml Dr Fixit Pidiproof LW per 50 kg cement on coving and joints of the APP membrane to seal all joints and cracks, complete all as specified and directed by the Engineer-in-Charge. Note: The place of disposal shall be identified by the contractor. |
| 157 | Removal of existing waterproofing treatment of the roof, including cleaning the concrete surface with wire brush and high-pressure water jet to ensure it is free of dust, oil, grease, loose particles and vegetation roots of any description, and including demolition of CC tiles, waterproofing membrane, PCC padding, brickbats or other materials of any description and in any position and depth, and removing all demolished materials outside MD land with necessary arrangements, complete all as specified and directed by the Engineer-in-Charge. Note: The place of disposal shall be identified by the contractor. |
| 158 | M&L for PCC 1:1.5:3 using 20 mm graded stone aggregate, mixed with waterproofing compound, laid over roof slab above 25 m height using necessary arrangements, as concrete padding or coving, and laid to the required slope, including finishing the concrete surface even and smooth without using extra cement, complete all as specified. Note: (i) PCC padding shall be carried up in coving at all vertical projections above roof up to a height of 150 mm. |
| 159 | M&L for applying 4 mm thick APP (Atactic Polypropylene) bitumen membrane, APP-modified, weighing not less than 3.5 kg/sqm, reinforced with non-woven polyester fibre of 160 gsm as centre core and without multiple polyethylene layers, finished on both sides with 7-micron thick flammable polyethylene film, applied by thermo-fusion using LPG torch on the primed surface after applying bituminous primer @ 0.25 kg/sqm; membrane to be laid with overlaps of 100 mm on sides and 150 mm at ends, complete all as per manufacturer’s instructions. |
| 160 | Cutting grooves 75 mm wide and 65 mm deep in brickwork or RCC surfaces at any location using mechanical cutter, shaping horizontal face, and filling the groove with PCC 1:2:4 type B-0 (using 12.4 mm graded stone aggregate) mixed with chemical compound Super Latex or Dr Fixit (Pidilite) or SBR Latex of STP Ltd, mixed at the rate of 200 ml per 50 kg cement, all as per manufacturer’s instructions and as specified and directed. |
| 161 | M&L for cement concrete tiles, size 300 mm × 300 mm × 20 to 25 mm thick, coloured, machine-pressed, set and jointed in neat cement slurry using grey cement without pigment, and pointed with epoxy grout (3 mm joint width) in floors; including cutting and polishing over 20 mm thick cement screed bed in CM 1:3, complete all as directed by the Engineer-in-Charge. |
| 162 | M&L for 5 mm thick plastering in cement mortar 1:3 on concrete ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 163 | Material and labour for preparation of newly plastered or previously untreated wall surfaces, and applying two coats of 100% antifungal acrylic interior-grade paint over a coat of primer, complete all as specified and directed. |
| 164 | All as per Item 125, but applied on ceiling surfaces instead of walls. |
| 165 | M&L for preparation of old painted steel or steel-based surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by the Engineer-in-Charge. |
| 166 | Material and labour for filling crumple joints with non-bituminous PE foam filler boards, complying with IS 1838, minimum 450 mm width, installed as per manufacturer’s instructions including necessary scaffolding, complete all as specified and directed. |
| 167 | Demolition of RCC roof, floors, beams, landings and other similar suspended work, including breaking, removal and disposal of debris, complete all as specified and directed. |
| 168 | Taking down PVC rainwater pipes of any diameter, including all fittings such as shoes, bends, swan-necks etc., complete all as specified and directed. |
| 169 | S&F 75 mm bore CI soil/waste/vent pipe, sand-cast, with ears, jointed with cement mortar, fixed to walls or laid in trenches, complete all as specified and directed. |
| 170 | S&F CI bends (any radius) for 75 mm bore soil/waste pipes, including diminishing pieces or tapers fixed on walls, complete all as specified. |
| 171 | S&F bands, straps, supports or stays for rainwater or ventilating pipes, including bolts if required and similar small articles, conforming to Fe 290 Grade E-165, for new or old pipes in shafts up to 35 RM height, including scaffolding, complete all as specified. |
| 172 | S&F in repairs aluminium colour anodised sections of various sizes for frame/profile sections of roof sheeting, with one or more rebates, including joining cleats, beading, EPDM/rubber gasket or packing, screws, and all other fittings, including necessary scaffolding and safety arrangements, complete all as specified. |
| 173 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 174 | M&L for rolled mild steel sections for roof trusses, trussed purlins, posts, rails, fastenings including distance pieces, cleats etc., complete all as specified. |
| 175 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 176 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings completeall asspecified and directed by Engineer-in-Charge. |
| 177 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 178 | S & F in repairs 4 mm thick acrylic sheet frosted pattern or required colour including EPDM/rubber gasket, end cap, sealing tap and sealing with sealent including all necessary fittings, scaffolding and safety arrangement |
| 179 | S & F in repairs 10 to 12 mm polycarbonate sheet multilayered in roof including EPDM/rubber gasket, end cap, sealing tap and sealing with sealent including all necessary fittings, scaffolding and safety arrangement and aluminium runner fixed with self tapping screws as specified.(Alu section shall be msrd and paid seperately) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail