| 1 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, Foundation, filling of poles or stayscomplete all as specified and directed by Engineer-in-Charge. |
| 2 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting pointcomplete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as requiredcomplete all as specified and directed by Engineer-in-Charge. |
| 4 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 5 | Supply and laying sub class \"B\" bricks of(230x115x75 mm) or of size locally available ,laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 6 | Taking upthe existing cables from trenches of any size any type all as specified and directed by Engr-in-Charge. |
| 7 | Supply and lay cable XLPE insulated armored heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 150 Sq mm 3.5 core complete all as specified and directed.Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning, cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 8 | All as per item No. 7 here-in-before but of size 35 Sqmm 3.5 core |
| 9 | All as per item No. 7 here-in-before but of size 25 Sqmm 4 core |
| 10 | All as per item No. 7 here-in-before but of size 16 Sqmm 4 core |
| 11 | All as per item No. 7 here-in-before but of size 10 Sqmm 4 core |
| 12 | All as per item No. 7 here-in-before but of size 16 Sqmm 2 core |
| 13 | All as per item No. 7 here-in-before but of size 10 Sqmm 2 core |
| 14 | Supply and fix cable jointing kit for 1.1 KV grade cable for indoor end termination Heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 150 Sqmm to 185 sqmm, Indoor/Outdoor type |
| 15 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 50 Sqmm , Indoor/Outdoor type |
| 16 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 70, Indoor/Outdoor type |
| 17 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 95, Indoor/Outdoor type |
| 18 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 25 Sqmm to 35 sqmm, Indoor/Outdoor type |
| 19 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 10 Sqmm to 16 sqmm, Indoor/Outdoor type |
| 20 | Supply,installing, testing and commissioning of LT feeder pillar box factory made outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN),including provn of following :- Note : (a) The panel shall be as per CPRI certificate (b) Rates inclusive of PCC completei) Aluminium Bus bar 400-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulationii) MCCB 4 Pole , 250 Amp, 415 V, 25 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 01 No (incommer) iii) MCCB 4 Pole , 160Amp, 415 V, 25 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 04 Nos(outgoing)iv) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 No v) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT\"s & selection switch - 01 No vi) RYB LED indicator- one set |
| 21 | Supply,installing, testing and commissioning of LT feeder pillar box factory made outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN),including provn of following :- Note : (a) The panel shall be as per CPRI certificate (b) Rates inclusive of PCC completei) Aluminium Bus bar 400-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulationii) MCCB 4 Pole , 250 Amp, 415 V, 25 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 01 No (incommer) iii) MCCB 4 Pole , 160Amp, 415 V, 25 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 04 Nos(outgoing)iv) TPN 63Amp-01 No (Outgoing)v) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 No vi) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT\"s & selection switch - 01 No vii) RYB LED indicator- one set+B62 |
| 22 | Supply installing, testing and commissioning of LT feeder pillar box factory made Outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN), including provn of following :- Note :(a)The panel shall be as per CPRI certificate (b) Rates inclusive of PCC complete i) Aluminium Bus bar 400-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulationii) MCCB 4 Pole , 250 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 Nos (incoming) iii) MCCB 4 Pole , 160 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 04 Nos (03 OG + 01 SB) iv) TPN 63Amp-03 Nos (Outgoing)vi) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 No vii) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT\"s & selection switch - 01 No viii) RYB LED indicator- one set |
| 23 | S&F in repair powder coatedMild steel junction box wtih MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door, locking arrangements with 4 Nos Aluminum bus bars, 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc with suitable size flat iron clamps, nuts , boltscomplete including taking down all as specified and directed. |
| 24 | S&F 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA \"C\" sereis complete all as specified. |
| 25 | Supply, installation, testing and commissioning of LT paneloutdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate access cable alley made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 200 Amp, MCCB 4 Pole , 100 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) &RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copperconductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated paintingin inner & outer side, including making all suitable necessary electrical connection completeall as directed by the Engineer -in - Charge. Note : (i) The panel shall be as per CPRI certificate. (ii) The rates deemed to be inclusive necessary PCC for grouting of panels. |
| 26 | Material and labour for earthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing). |
| 27 | M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level )with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with galvanizediron GI earth wire 4mm dia by means ofbolt nut check nuts and washersof galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete |
| 28 | Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame,with lumen output not less than 9000 lumens suitable wattage for efficiency not less than 100 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc completeand testing on completion all as specified and as directed. |
| 29 | Plain cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) for coping of pole, transformer plinth/ foundation complete all as specified and directed. |
| 30 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |