Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for Checking of unserviceable Window/split AC/Water Cooler/DesertCooler U/S parts likewise relay, compressor, blade, motor, gas leakage,condensor coil, capacitor, Thermostate, Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs and made functional.(b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user.(d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor(f) Risk Factor will be the contractor \"s end |
| 2 | M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning Complete all as directed by Engineer-in-Charge. |
| 3 | S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity complete all as specified and directed. |
| 4 | S&F in repairs PVC fan blower of cooling side of window type AC of 1.5/2 TR capacity complete all as specified and directed. |
| 5 | S & F in repairs wiring kit of window type AC of 1.5/2 TR capacity complete with lugs, thimble and selector switch, complete all as directed. |
| 6 | S&F for motor for window type AC of 1.5/2 TR capacity, complete all as specified and directed. |
| 7 | M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.Note: Spare parts will paid in relevant item here in after and supply only items if replaced shall be credited to the contractor. |
| 8 | Supply only of air filter of size 10 micron Split type AC 1.5/2 TR |
| 9 | Supply only Blade for condensing fan motor Split type AC 1.5/2 TR |
| 10 | Supply onlyrunning Capacitor 50 Mfd for 2 TR AC |
| 11 | Supply only running Capacitor 45 Mfd for 1.5 TR AC |
| 12 | Supply only condenser coil aluminium/copper of ac capacity 1.5 TR AC |
| 13 | Supply only condenser coil aluminium/copper of ac capacity 2 TR AC |
| 14 | Supply only suction valve brass type 5/8\"of ac capacity 1.5 TR AC |
| 15 | Supply only suction valve brass type 5/8\"of ac capacity 2 TR AC |
| 16 | Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR AC |
| 17 | Supply only swing motor for air adjust of suitable size for AC 1.5/2 TR |
| 18 | Supply only relay for overload of suitable size for ac capacity 1.5/2 TR |
| 19 | Taking downelectronic remote circuit board (PCB) ofwindow type AC 1.5/2 ton for repairs and re-fixing after repair complete all as specified and directed. |
| 20 | Taking down electronic remote circuit board (PCB Indoor & Outdoor) ofsplit type AC 1.5/2 ton for repairs and re-fixing after repair complete all as specified and directed. |
| 21 | Supply onlyelectronic remote circuit board (PCB)of window type AC suitable for 1.5/2 ton AC complete all as specified and directed. |
| 22 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC indoor unit of Capacity 1.5/2 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 23 | S & F in repairs PCB Senser unit with wire remotre control of ductable split AC outdoor unit of Capacity 1.5/2 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 24 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC indoor unit of Capacity 1.5/2 TR (PCB Inverter Type indoor units) for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 25 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC indoor unit of Capacity 1.5/2 TR (PCB Inverter Type outdoor units) for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 26 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same after repair and made functional complete all as directed by Engr-in-Charge. |
| 27 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same after repair and made functional complete all as directed by Engr-in-Charge. |
| 28 | S&F in repair of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR. Complete all as directed. |
| 29 | M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 1.5 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning. Complete all as directed by Engineer-in-Charge. |
| 30 | Ditto asabove but for window/split type AC 2 TR capacity….ditto…... |
| 31 | M & L for removing the unserviciable compressor sealed unit of any make from water cooler 40/80 ltr after cutting copper tubing without any damage to existing part ,replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc, jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins, leakage testing etc including testing for smooth functioning. complete all as directed by engr in charge. |
| 32 | S&F in repair Compressor for Deepfreezer capacity 300 ltr with relay and thermostat completeafter dismantling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level all as directed . |
| 33 | Supply & fix rubber gaskit of standard size for deep freezer with suitable screw and adhesives including removing u/s gaskits all as directed by Engineer-in-Charge. |
| 34 | S&F in repairs aluminium fan blade for water cooler of any capacity complete all as specified and directed. |
| 35 | S&F in repairs thermostat suitable for water cooler of any capacitycomplete all as specified and directed.. |
| 36 | S&F in repairs waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 ltrs. Complete all as directed |
| 37 | S & F in repair PVC drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size complete all as directed |
| 38 | S & F in replacement push cock 15mm bore made out of brass chromium plated self closing vertical type complete all as directed |
| 39 | Supply & fixing in repair copper cooling coil for deep freezer of capacity 310 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing. |
| 40 | Spply & fixing in repair of condensor motor of deep freezer of capacity 400 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing. |
| 41 | Supply& fix in repair 3 pin plug top of 15 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 2.5sqmm of 3 mtr length for deep freezer. |
| 42 | M & L for repair for cutting and removing unserviceable freezer unit of refrigerator capacity 165/170/175 ltrs of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerator gas and testing for smooth functioning. Complete all as directed. |
| 43 | S & F in repairs of bulb for pin/screw type 230 Volts suitable for refrigerator 175 to 310 ltrs capacity |
| 44 | Supply and topping up of Refrigerant gas R 134/404 inrefrigerators/Deep freezers at different site as required including brazing and removal of leakage in equipment |
| 45 | Supply & fixing in repair copper cooling coil for refrigerator of capacity 190 ltrcomplete all as specified and directed. |
| 46 | Supply& fix in repair 3 pin tlug top of 5 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 40/0.0076 of 3 mtr length for refrigerator complete all as specified and directed. |
| 47 | M&L for cleaning after takingdown complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamelspray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. Complete all as directed by Engr-in-Charge. |
| 48 | S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc. complete all as specified and directed. |
| 49 | S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolerscomplete all as specified and directed. |
| 50 | S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as directed . |
| 51 | S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers complete all as specified and directed. |
| 52 | S&F repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolerscomplete all as specified and directed. |
| 53 | S&F in repairs capacitor 4 Mfd for fan motors of desert coolers complete all as specified and directed. |
| 54 | S& F in repairs Submersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiringcomplete all as specified and directed. |
| 55 | S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed. |
| 56 | S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142 gm/eachcomplete all as specified and directed. |
| 57 | S & F in repairs Aluminium fan blade for fan motor of desert cooler 20 inch sweepcomplete all as specified and directed.\" |
| 58 | S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/screws complete all as specified and directed. |
| 59 | S&F in repair desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer complete all as specified and directed. |
| 60 | Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Ampscomplete all as specified and directed. |
| 61 | Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed.Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.(ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii)The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa. (iii) Writing of MES no after repair is compulsury. |
| 62 | Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mmsweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the departmentcomplete all as specified and directed. Make of winding wire: Atlas/Finolex/ Devi Dayal |
| 63 | Ditto as abovebut rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire….ditto…. |
| 64 | Ditto as above but rewinding of motor of exhaust fans of 300/400/450 mm sweep with 200 gram winding wire….ditto….. |
| 65 | Ditto as above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire…..ditto… |
| 66 | Ditto as above but rewinding of motor of pedestal fan of 400 mm sweep with 400 gram winding wire….ditto…... |
| 67 | Supply only in replacement complete fan hanging assembly set comprising with rubber reel,MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed. |
| 68 | Supply only in replacement PVC insulated, flexible cable, twin core twisted of size 23/0.0076 with copper conductor in pieces for connecting fans complete all as specified and directed. |
| 69 | Supply only in replacement 300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed. |
| 70 | Supply only in replacement 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed. |
| 71 | M&L for taking down Ceiling Fan of any size/make fixed/hanged at different locations & replacing conventional fan rod with An anti-suicide fan rod of 300 mm and white in color with is a specially designed down rod used to hang a ceiling fan that incorporates a mechanism to prevent suicide by hanging.They typically work on Spring Mechanism having two parts, an upper and lower section, held together by a spring mechanism. Automatic Release, if a weight exceeding a certain threshold (typically around 20-25 kg) is applied to the fan (as would be the case in an attempt to hang), the rod\"s joint separates, and the spring expands. This expansion allows the fan and the applied load to descend safely, preventing the person from being fully suspended. The spring keeps the fan above the person\"s head, minimizing the risk of injury as they land on the ground. Benefits. The primary purpose is to deter and prevent suicide attempts by hanging from ceiling fans. They are designed to be safe for normal use, only activating when an abnormal load is applied, relatively easy installation and compatibility with most ceiling fan models includingclamps and necessary related items all as per site requirement specified and directed by Engg-in-charge.with replacement ofmultistrandedcopper conductor cable of size 23/ 0.193 from ceiling rose to fan terminalincluding making necessary electric connections & testing complete all as specified & directed. Make- Gold life or equivalent as approved by GE.(Note: This is only designed for to prevent suicide by hanging, safe for normal use, not for risk of injury.)NOTE : (i) Quoted rate isdeemed to be inclusive of Anti-Suicide Fan rod and rubber reel & testing of serviceable rubber reel & cleaning / dusting of C/F an completeall as specified & as directed to the entire satisfaction of the Engr-In-Charge. |
| 72 | S&F in replacement ball bearing No. 6200 to 6204 complete all as specified and directed.Make:-SKF/NRB/NBC/TATA |
| 73 | S&F in replacement gun metal bush of any description and size to suit existing motor shaft complete all as specified and directed. |
| 74 | M&L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying two coats of synthetic enamel paint by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed. |
| 75 | S&F in replacement capacitor of capacity 2.5 mfdPVC body complete all as specified and directed. |
| 76 | S&F in replacement capacitor of capacity 3.15 mfdPVC body complete all as specified and directed. |
| 77 | S&F in replacmentmotor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed. |
| 78 | S & F in replacement Printed Circuit board (PCB) of ceiling fan 1200/1400mm sweep of any Make Havells/Crompton complete all as specified and direcetd by Engr-in-Charge. |
| 79 | S&F in repair of factory made epoxy powder coated distribution board double doorTP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 80 | S&F in repair of factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 81 | S&F in repair offactory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 82 | S&F in repair of factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 83 | S&F in repair of sheet metal enclosure distribution board SPN 2 ways complete all as specified and directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 84 | S&F in repair MCCB, 4 pole,63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 85 | S&F in repair MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 86 | S&F in repair MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 87 | S&F in repair MCB, SP, 6 to 32 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 88 | S&F in repair MCB, SP, 40 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 89 | S&F in repair MCB, SPN, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 90 | S&F in repair MCB, TP, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 91 | S&S&F in repair MCB, TPN, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 92 | S&F in repair sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified. |
| 93 | Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 94 | M&L for point wiring for one Light/fan point controlled by one switch controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with sunmica/Bakelite sheet 3mm thick and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed .Note:- (i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 95 | Ditto as above One 5 Amps socket point controlled by one 5 Amps switch on same board….ditto…. |
| 96 | Ditto as above One 5 Amps socket point controlled by one 5 Amps switch on independent board.…..ditto…. |
| 97 | Ditto as above One bell point controlled by one 5 Amps bell push…..ditto… |
| 98 | Ditto as above One light point controlled by two 5 Amps two way switch…..ditto…. |
| 99 | M&L for point wiring for 3 pin 15 Amps socket independent with(FRLS) flame retardant low smoke PVCinsulated unsheathed cable 2.5 sqmm with multistranded copper conductor,in and including non metallic PVC concealed conduitnot less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with sunmica/Bakelite sheet 3mm thick including(FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly completeNote:- (i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 100 | M&L for point wiring of one Light/fan point controlled by one switch controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes with sunmica/Bakelite sheet 3mm thick and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note :- (i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 101 | Ditto as above One 5 Amps socket point controlled by one 5 Amps switch on independent board. …..ditto… |
| 102 | Ditto as above One bell point controlled by one 5 Amps bell push.…..ditto… |
| 103 | Ditto as above One light point controlled by two 5 Amps two way switch.…..ditto… |
| 104 | M&L for point wiring for 3 pin 15 Amps socket independentwith(FRLS) flame retardant low smoke PVCinsulated unsheathed cable 2.5 sqmm with multistranded copper conductor,in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wallwith sunmica/Bakelite sheet 3mm thick including(FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly completeNote :-(i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 105 | S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 106 | S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed. |
| 107 | S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 108 | S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 109 | S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 110 | S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 111 | S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 112 | S&F fan regulatorelectronic step up type, 80/100W SP 230 voltcomplete all as specified and as directed. |
| 113 | S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 114 | S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 115 | S&F in repair 10 watt LED light fitting engineeringextruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:-HavellsLHEXAZP71N1W020 or equivalent in Phillps, Crompton |
| 116 | S&F in repair 20 watt LED light fitting engineeringextruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- HavellsLHEXAZP7PN1W020 or equivalent in Phillps, Crompton |
| 117 | S&Fin repairrecess mounting LED luminaire of size 2\"x2\"white 30 watt, 230 voltsfor ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:-HavellsLHEBAEP51W1W036 or equivalent in Phillps, Crompton |
| 118 | S&Fin repairrecess mounting LED luminaire round shape 10 watt, 230 voltsfor ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- HavellsLHEBBLPSUZ1W015 or equivalent in Phillps, Crompton |
| 119 | S&Fin repair testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED Street light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Philips or equivalent in Havells, Crompton |
| 120 | S&Fin repair testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on wall using nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-PhilipsBVP120LED35CWFG or equivalent in Havells, Crompton |
| 121 | S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed. |
| 122 | Taking down carefullyold and unserviceable sub main wiring of 2/3 runs ormain-wiring of any size ofaluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed. |
| 123 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed.Note:- (length of 2 No 2.5 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 124 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. Noe:- (length of 2 No 4.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length). |
| 125 | M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. Note:- (length of 2 No 6.0 Sqmm conductor cable, 1 No. 6.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 126 | Supply only in replacement lamp LED 12 watt, 240 volts complete all as specified and directed. |
| 127 | S&Fmodular type PVC enclosure with a two pin and earth plug and socket16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed. |
| 128 | S&F in replacment single core 1.5sqmm copper cable Heat Resistant Flame Retardant (HRFR) PVC Insulated Industrial flexible cable 1100 voltscomplete all as specifeid and directed. |
| 129 | S&F in replacment single core 2.5sqmm copper cable Heat Resistant Flame Retardant (HRFR) PVC Insulated Industrial flexible cable 1100 voltscomplete all as specifeid and directed. |
| 130 | S&F in replacment single core 4sqmm copper cable Heat Resistant Flame Retardant (HRFR) PVC Insulated Industrial flexible cable 1100 voltscomplete all as specifeid and directed. |
| 131 | Supply and fix in replacment Industrial Plug and socket,16 Amps, 5 Pin (3P+N+E) for three phase supplycomplete all as specified and directed. |
| 132 | Supply and fix in replacment Industrial Plug and socket,32 Amps, 5 Pin (3P+N+E) for three phase supplycomplete all as specified and directed. |
| 133 | Supply and fix in replacment Industrial Plug and socket,63 Amps, 5 Pin (3P+N+E) for three phase supplycomplete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy