| Sl. No. | Item Description |
| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts, guard bars etc. of area 3 sq. metres and below complete and stacking within 50 metres lead complete all as specified and as directed. |
| 2 | Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. NOTE :- Glazing, paneling and dash fasteners to be paid for separately. |
| 3 | Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges, pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required complete all as specified and as directed. NOTE :- Fittings shall be paid for separately. |
| 4 | Providing and fixing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-Charge . NOTE :- Cost of aluminium snap beading shall be paid in basic item. |
| 5 | Providing and fixing with float glass panes of 4 mm thickness (weight not less than 12.50 kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-Charge . NOTE :- Cost of aluminium snap beading shall be paidin basic item. |
| 6 | Providing and fixing 12 mm thick pre laminated particle board with decorative lamination on one side and balancing lamination on other side flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P . brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. |
| 7 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc.complete all as specified and as directed. |
| 8 | Providing and fixing false ceiling at all heights with 16 mm thick beveled tegular mineral fibre false ceilingtregular edged ceiling tiles 595x595 mm tile (NRC 0.55 to 0.60) of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stitched double webbed white with 6mm reveal profile (white/ black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 9 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns, sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and as directed. |
| 10 | Providing and fixing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and as directed. |
| 11 | Material and labour for painting with synthetic enamel paint of approved tint to new steel surfaces and two or more coats on new work of approved brand and manufacture to give an even shade complete all as specified and as directed. |
| 12 | Excavation work by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), for all kind of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m complete all as specified and as directed. |
| 13 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and as directed. |
| 14 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at cill level and lintel level with approved block laying polymer modified adhesive mortar complete as per direction of Engineer-in-Charge. NOTE :- The payment of RCC band and reinforcement shall be made for separately. |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m complete all as specified and as directed. |
| 16 | Removing excavated soil / material n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 17 | Material and labour for 15 mm cement plaster on rough side of single or half brick wall ofmix 1:6 (1 cement: 6 coarse sand), finishing the surfaces even and smooth w/o using extra cement complete all as specified and as directed. |
| 18 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and as directed. |
| 19 | Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, flooring, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing complete all as specified and as directed. |
| 20 | Providing and laying Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and as directed. |
| 21 | Material and labour for TMT steel reinforcement of RCC Work including straightening, cutting, bending, placing in position and binding using TMT bars of grade Fe-500D or more below/above plinth level complete all as specified and as directed. |
| 22 | Providing centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers complete all as specified and as directed. |
| 23 | Complete removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and as directed. |
| 24 | Material and labour for distempering with 1st quality acrylic distemper or oil bound distemper for walls and ceiling(Ready mix) having VOC content less than 50 grams/ litre of approved brand, tint and manufacture to give an even shade : new work (two or more coats) including applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre complete all as specified and as directed. |
| 25 | Providing and applying wall putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed. |
| 26 | Material and labour for 25mm thick Plain Cement Concrete, (1:2:4), type B0, using 12.5mm graded stone aggregate as in bedding, finished fair and even complete all as specified and as directed. |
| 27 | Providing and laying double charged vitrified tiles polished/ matt finished coloured of size 600x600 mm as in floors in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid over and including 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and as directed. |
| 28 | Material and labour for providing the sealant (pouring grade) in the existing 10mm wide and 40mm deep groove/joint after preparation of jointsalong with application of primer all as per manufacture instructions complete all as specified and as directed. MAKE :- Thioflex 600 shall be of M/s FOSROC/MASTERFLEX TM 700i of BASF or equivalent in CIPY andPrimer 7E shall be M/s FOSROC or equivalent in BASF/CIPY. NOTE :-Application of Epoxy and sealant shall be carried out by authorised applicator ofmanufacture with prior approval of GE |
| 29 | Material and labour for heavy duty Epoxy resin based flooring with moisture barrier of total 4mm thick consisting of preparation and removing existing epoxy floor topping by light grinding/shot blasting/wire brushing etc to provide mechanical key to receive floor topping, the prepared surface shall be provided using two component epoxy resin based system Nitoprime 25 of FOSROC or equivalent at 6 sqm/litre in one coat and allowed to dry for 24 hrs, over this primer coat solvent free 3 part high strength trowel applied screed having mimimum compressive strength of 90/Nmm2, tensile strength of 20 N/mm2 and flexural strength of 40N/mm2 to thickness of 2mm shall be applied by spreading with towel and finished by proper compaction and allowed to dry to cure for 24 hrs (Nitoflor TS5000 or Fosroc or equivalent), after curing two component epoxy resign based system (Nitoflor FC140 or equivalent) putty mixed with quartz filler quartz filler shall be applied for the sealing the porous surface of epoxy screed system, Nitoflor TF5000 of Fosroc or equivalent,after this, a shop coat of two compotent epoxy resisn based system, Nitoflor FC150 of FOSROC or equivalent shall be applied in two coats at 400 microns covering 10 sqm of 4.5L pack as top coat. NOTE :- Applicator of epoxy flooring shall be executedwith authorised aoolicator of approved manufacturer with prior approval of GE. |
| 30 | Providing and fixing fly proof wire gauze stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows and doors with MS flat iron of 15x3 mm and nuts and bolts complete all as specified and as directed. |
| 31 | Supply and fixing for Roller venetian zebra blinds, horizontal type, two layer style with approved fabric and powder coated aluminium fittings such as top rails metal weight nylon button loops etc to match with the top rail metal base complete all as specified and as directed. Note: The colour, design and shade shall be as approved by GE. (Make :Vista/Amar) |
| 32 | Taking down rain water pipes (any size or pattern) including all fittings bends etc complete all as specified and as directed. |
| 33 | Supply and fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, type \"B\" laid in trenches or in floors complete all as specified and as directed. |
| 34 | Supply and fix 110mm bore PVC (SWR) couplers type \"B\" complete all as specified and as directed. |
| 35 | Supply and fix 110mm bore PVC (SWR) bends any radius type \"B\" complete all as specified and as directed. |
| 36 | Material and labour for packer drilling, installation and finishing drilling and fixing injection packers in RC members including, drilling holes in structural members at the intervals including cleaning the holes by vaccum cleaner prior to fixing nozzles all as directed by Engineer in charge. |
| 37 | Supply and apply a shrinkage free low viscous epoxy resin based injection grout.Product: Dr. Fixit epoxy injection grout/Sikadur®-55 LP IN.Yield: 0.88 ltr/kg Product requirements: Compressive strength >= 70 N/mm2 (7 days) according to BS 6319:PART 2; Flexural strength > 30 N/mm2 (7 days) according to BS 6319:PART 3; Tensile strength > 15 N/mm2 (7 days) according to BS 6319:PART 7; Bond strength > 10 N/mm2 (14 days) or concrete failure according to ASTM D 4541 |
| 38 | Material and labour for 15 mm cement plaster on rough side of single or half brick wall ofmix 1:4 (1 cement: 4 coarse sand), finishing complete all as specified and as directed. |
| 39 | Removing dry or oil bound distemper / exterior paint / cement base paint, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc and finishing walls with ready mixed premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance on old work (two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.dirt resistance exterior paint of required shade with silicon additives complete all as specified and as directed. |
| 40 | Demolition POP false ceiling, cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and as directed. |
| 41 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm,suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of siz76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange topierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws and With 15 mm thick Tegular edged light weight calciumsliciate false ceiling tiles. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge |
| 42 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres & above each complete all as specified and as directed. |
| 43 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge |
| 44 | Material and labour forprelaminated particle board of 9mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work directed by EIC. |
| 45 | Supply and fix in repairs venetian blinds of horizontal type, 20-30mm slot width of approved fabric &top rails linked together by a cord pulley system complete all as specified, including dismantling old damaged one complete all as specified and as directed.Note: The colour, design and shade shall be as approved by GE. |
| 46 | Dismantling boarding, any description, fixed in any position fixed with screws complete all as specified and as directed. |
| 47 | Material and labour for solid PVC wall lining consisting of 5mm thick wood grain printed colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 48 | Supply and fix 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 49 | Providing and fixing M.S. grills of required pattern in frames of windows fixed to openings /wooden frames with rawl plugs screws etc . with MS flats, square or round bars etc. including priming coat with approved steel primer all complete all as specified and as directed. |
| 50 | Material and labour for painting to steel work with deluxe multi surface paint to give an even shade, two or more coats applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand, tintand manufacture complete all as specified and as directed. |
| 51 | Material and labour for door closer ofhydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 52 | Material and labour for Mortice lock, vertical type, size 100mm,brass metal and4 leverscomplete all as specified and as directed. |
| 53 | Taking down carefully un serviceablealuminium/ copper point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose,light fittings etc, removing allmaterial for reuse/ issued under sch of credit and making good the disturbed surface as the existing one, complete all as specified and as directed. |
| 54 | Taking down existing copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 55 | Material and labour for wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required for one Light point/wall fan/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and as directed. |
| 56 | Material and labour for wiring for twin control light point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required for one light point controlled by two wayswitch complete all as specified and as directed. |
| 57 | Material and labour for wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required complete all as specified and as directed. |
| 58 | (a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (for 5Ampssockets & wall mounted socket. |
| 59 | (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire for 15 Amps power sockets. |
| 60 | (c) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. |
| 61 | (d) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 62 | (e) 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 63 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amps modular socket outlet and 5/6 A modular switch, connections etc as required complete all as specified and as directed. |
| 64 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amps modular socket outlet and 15/16 A modular switch, connections etc as required complete all as specified and as directed. |
| 65 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required complete all as specified and as directed. |
| 66 | Supply and fix ceiling rose surface backelite two to three terminal complete all as specified and as directed. |
| 67 | Supply and fix fan step regulator 120 watt, 2 module complete all as specified and as directed. |
| 68 | Dismantling and refixingthe ceiling fan complete of any type and size, cleaning, servicing, greasing to bearings checking of nuts bolts, safety split pin, bushes, capacitor and complete spray painting as directed by Engr-in- chargetesting complete all as specified and as directed. NOTE :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted. |
| 69 | Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper winding from the rotor assembly and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials, varnishing, reassembling, greasing to bearing, replacing bushes, replacement of capacitor and complete testing complete all as specified and as directed. NOTE:- (a) The spares like ball bearing, capacitor and GM bush required for repairing the ceiling fan will be measured in the rate quoted.(b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and for from site to work place are deemed to be included in rate quoted. |
| 70 | Dismantling and refixing the exhaust fan complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete spray painting as directed by Engr-in- chargetesting complete all as specified and as directed. NOTE :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted. |
| 71 | Dismantling all components of Exhaust fan of any size/capacity sweep, cutting and removing burnt out copper winding from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacement of capacitor and complete testing complete all as specified and as directed. NOTE :- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured including in the rate quoted.(b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and for from site to work place are deemed to be included in rate quoted. |
| 72 | Supply and fix Recess mounted full panel LED luminaire 36 watt fitting 2’x2’ with white powder coated housing & frame in CRCA sheet, high efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED colour temperature – 5700k, IP20, 50000 burning hours as per L70 criteria, ambient temperature -0 to 50 Deg C, Driver efficiency >85%, THD<10%, PF>0.95, surge protection in CM-3KV, Multistage isolated constant current, constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and as directed. NOTE :- (i) All necessary fixing/connecting arrangements to be provided by the contractor without any extra payment from department.(ii) Quoted rate is to be deemed to be included the charges of necessary boom fit. |
| 73 | Supplying and fixingLED light fitting 1 x 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 74 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 75 | Supply and fixing LED building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including 1.5 Mtr length GI tubing medium grade 25mm dia bent to shape with necessary CI clamps, bolts etc., for fixing and connecting from ceiling rose to filling with 3 core 1.5 sq.mm insulated copper cable complete all as specified and as directed. NOTE :- (i) All necessary fixing/connecting arrangements of nuts, bolt, MS rod to be provided by the contractor without any extra payment from department.(ii) Quoted rate is to be deemed to be included the charges of necessary boom fit. |
| 76 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 600mm sweep 900RPM with, blades, and frame and louvers including cutting the wall of stone/ brick masonery as per the size of exhaust fan including grouting the bolts, nuts etc for fixing necessary connection with three core flexible wire from and making good the disturbed surface as the existing one, exhaust fan to ceiling rose complete all as specified and as directed. |
| 77 | Supply and fix SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with200 Amps rated bus bar 8 way 240Volts complete all as specified and as directed. |
| 78 | Supply and fix SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with200 Aamps rated bus bar 6 way 240Volts complete all as specified and as directed. |
| 79 | Supplying and fixingSPN 32A rating 240/415 V, 10KA \"C\" curve, miniature circuit breaker suitable for inductive load of specified poles in the existing MCB DB complete testing and commissioning etc as required |
| 80 | Supplying and fixingSP 5A to 32A rating 240/415 V, 10KA \"C\" curve, miniature circuit breaker suitable for inductive load of specifed poles in the existing MCB DB complete testing and commissioning etc as required complete all as specified and as directed. |
| 81 | Supplying and fixing of 8 ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required, double door complete all as specified and as directed. |
| 82 | Supplying and fixing4 pole MCCB withhermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections of size 250A, 36KA breaking capacity and, 50Hz, 415V, FP MCCB complete all as specified and as directed. |
| 83 | Supplying and fixing4 pole MCCB withhermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections of size100A, 16KAbreaking capacity and, 50Hz 415V, FP MCCB complete all as specified and as directed. |
| 84 | Supply and fix Air Circulator fan steel body, AC, single phase. 230V of size 450mm sweep, 1440 RPM suitable for wall mounting with all accessories complete all as specified and as directed. |
| 85 | Supply and fix ofair curtain 6 ft with senser, max air velocity at nozzle 21m/s, power 820W, RPM (max/Min)- 2700/2100, cfm 1490, single phase, noise level (dB) - 50-70 db with complete accessories and all fixing arrangement as required at site with complete connection & testing all as specified and directed. |
| 86 | Material and labour for point wiring complete with 1100 Volts, FRLSH Grade, 1.5 sq.mm, single core, PVC Insulated, unsheathed, multi stranded copper conductor cable, confirming to IS - 694 drawn through and including stove enameled metallic conduit of suitable 25mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 sq.mm, single core, PVC Insulated, unsheathed, multi stranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for one light / fan point controlled by one Switch complete all as specified and as directed. |
| 87 | Supply and fix LED flame proof light fittings 80 Watt, IP-66 very high efficiency round high bay in internal ignition within a flammable atmosphere will not transmit outside the protective enclosure, CIMFR-BIS-PESO certified, recommended for gas group IIC, zone 1 and 2 temperature class T6 complete all as specified and as directed. NOTE :- (i)All necessary fixing/ connecting arrangements of nut, bolt, MS rod, to be provided by the contractor without any extra payment from department.(ii)Quoted rate is to be deemed to be included the charges of necessary boom lift. |
| 88 | Supply and fix switch flame proof rotatory type with termination box in LM,16 Amps, single pole 250 V complete all as specified and as directed. |
| 89 | Material and labour for earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required complete all as specified and as directed. |
| 90 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required complete all as specified and as directed. |
| 91 | Supply and fix compact and decorative energy efficient round / square type recess / surface mounted LED 15/18W down light fitting and making all connections complete all as specified and as directed. . |
| 92 | Supply and fixing LED spot light fitting surface mounting type with white powder coated aluminium housing and pressure die cast heat sink having high efficiency, 8 watts 220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 93 | Supply, install, testing and commissioning of 2 Ton 5 Star (ISEER value from >=5 to <=5.5) split air conditioner,Inverter Smart Energy Display, Dual Filtration with HD & PM 2.5 Filter, ESTER EDGE FXI AC with Wi-fi connect including all fixing arrangement complete with cordless remote control unit with latest dual invertor technology having ECO friendly refrigerant gas copper condenser coil of capacity (as per requirement at site) all as specified and directed by Engineer-in-Charge. MAKE :-DAIKIN Cat Part No CAI24EE5R35W0with Hi Copper Condeser or techno commercially equivalent makes specified in PSwith following specifications:-(i)Cooling capacity - 2.2 Ton(ii)Inverter Technology :Dual inverter for energy efficiency and smooth operation.(iii)Air Throw 22* Meters (72 feet):With the Cross Flow Evaporator Fans, Carrier air conditioner\"s every product is prefected and re-perfected to ensure they deliver and carry the badge of trust.Air flow upto 22* meters (72 feet) away from the unit ensures uniform and powerful cooling. |
| 94 | (v)Features:Includes power chill for rapid cooling, dry mode function for dehumidification and 3D air flow for steady air circulation.(vi)3D Airflow:Enjoy uniform cooling at every corner.Daikin\"s 3-D ensures steady air circulation to delivery even cooling and unmatched comfort.The flap and louver move in tandem with each other to irculate the air in the entire room.(vii)Cools at 45O C:Unlike most regular air conditioners that are designed to deliver cooling at 35O C.Daikin air conditioners are designed to perform at extreme ambient conditions as high as 54O C. This makes them the ideal choice for dry and tropical countries.(viii)Power Chill Operation:When you need fast relief from the heat, power chill rapidly cools the room, making it comfortable in minutes.(ix)Dry Mode Function:Automatic dehumidification, perfect for hot & humid places.Enhanced comfort by reducing excessive humidity.(x)Warranty 1 year for product and 10 year for compressor. |
| 95 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 5 KVAcomplete all as specified and as directed. |
| 96 | Supply and laying of extra copper pipe of size 3/4\" with nitrile rubber tubular insulation and copper cable using necessary supports and fastners complete all as specified and as directed. |
| 97 | Supply and laying of extra copper pipe of size 1/2\" with nitrile rubber tubular insulation and copper cable using necessary supports and fastners complete all as specified and as directed. |
| 98 | Material and labour for MS stand duly painted suitable for fixing 2 TRAC outdoor unit and fixed complete all as specified and as directed. |
| 99 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required complete all as specified and as directed. |
| 100 | Material and labour for HDPE pipe 20 mm dia fixed to wall on roof complete all as specified and as directed. |
| 101 | Supply, install, testing and commissioning of five star rated Dual Inverter type wi fi enabled hi wall split air conditioner units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality having operating modes of Climate control,Dual user setting preferences,(Modes-Auto / Cool / Fan / Dry),Decimal setting,R-32/ECO friendly refrigerant gas, Indoor noise level 37dB to 45 dB,ISEER-5W/W,AC,230V,50 Hz, copper condenser coil of cooling capacity 5180 W / 1.5 TR including all fixing arrangements including copper pipe and refrigerant gas (as per requirement at site) complete all as specified and as directed by Engr-in-Charge. |
| 102 | Supply and fix voltage stabilizer suitable for 1.5 TR inverter AC,digital display, intelligent time delay system, automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 270 volts AC with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 4 KVAcomplete all as specified and as directed. |
| 103 | Material and labour for 25 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm fixed complete on walls, ceilings including all accessories complete all as specified and as directed.(Drain pipe ) |
| 104 | Supply and fix MCB SP 5-32 Amps rating 240 V,10 KA \"C\" curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete all as specified and as directed. |
| 105 | Supply and laying of extra copper pipe of size 1/4\" with nitrile rubberinsulation and thermo rexine tape using necessary supports and fastners complete all as specified and as directed. |
| 106 | Material and labour for MS stand duly painted suitable for fixing 1.5 TRAC outdoor unit and fixed complete all as specified and as directed. |
| 107 | Making opening/drilling of size 65 mm dia, using heavy duty stone driller/cutter machine in the stone machinery wall for installing split type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail