| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings (Modular/ Non Modular) such as switches, ceiling roses, pendants, regulators, sockets, light fittings any type etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.complete all as specified & directed. |
| 2 | M & L for surface point wiring for one light / fan /exhaust fan points/bell pointscontrolled by one way 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & includingPVC casing -N- caping/ surface non metallic medium PVC conduit mediumgrade with fittings (ISI marked) not less than 20 mm size& sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted. |
| 3 | All as per item No. 02 mentionedhere in before but one 3 pin 5 Amp switch socket outlet on same board with accessoriescomplete all as specified and directed |
| 4 | All as per item No. 02 mentioned here in before but one 3 pin 5 Amp switch socket outlet on independent boardcomplete all as specified and directed. |
| 5 | M & L for surface point wiring for one 15A socket point controlled by one way 15A switch on independent board controlled with 1100 volt grade PVC insulated-unsheathed 2.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 2.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & includingexisting conduit& sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted. |
| 6 | M & Lfor point wiring for one light/ fan point/call bell /exhaust fan point controlled by one wayswitch with 1100 volt grade PVC insulated FRLSH 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed FRLSH, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc& sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches fixed with brass screw complete all as specified and directed. |
| 7 | All as per item No.06 mentioned here-in-beforebut 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete all as specified and directed. |
| 8 | All as per item No 06 mentioned here-in-before but 1.5 Sq mm for 5 Amp switch socketon independent board with 1.5 Sq mm earth wire complete all as specified and directed. |
| 9 | M & L for point wiring for 15 Amp 3/5 pin socket power point with using with FRLSH PVCinsulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing/ fixingswitches etc.,includingcutting holes for switches,sockets,regulators etc as per requirement includingfixing with machine screw,washer etccomplete all as specified and directed. |
| 10 | S&F switch piano Flush type, single pole, one way ,6 amp 240 volts, complete all as specified and as directed. |
| 11 | S&F switch piano Flush type, single pole,15/16 amp 240 volts, complete all as specified and as directed. |
| 12 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 13 | S&FSocket outlet 2 in 1, 3 pin, 15 Amps, flush type complete all as specified and as directed. |
| 14 | S&F Switch socket combination 2 in 1, 3 pin, 5 Amps flush type,universsal complete all as specified and as directed. |
| 15 | S&F Switch socket combination 2 in1, 3 pin,5 and 15 Amp flush type,universal complete all as specified and as directed. |
| 16 | S&F Stepped type electronic fan regulatoron the existing phenolic laminated sheet complete all as specified and as directed. |
| 17 | S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and as directed.. |
| 18 | S&F in replacement of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with with with IP-43 IK-09 protection including 200 Amp rated bus bar and neutral link (ISI marked) confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. |
| 19 | S&F in replacement of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with with with IP-43 IK-09 protection including 200 Amp rated bus bar and neutral link (ISI marked) confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 08 way complete all as specified and directed by Engr-in-charge. |
| 20 | S&F in replacement of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with with with IP-43 IK-09 protection including 200 Amp rated bus bar and neutral link (ISI marked) confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 12 way complete all as specified and directed by Engr-in-charge. |
| 21 | S&F in repair 240V, 10KA\"C\" curve miniature circuit breaker (MCB) of single poles & neutral (SPN) and current carrying capacity32 Amp with breaking capacity 10 KA ,in the MCB DB with connection testing and commissioning complete all as specified and as directed. |
| 22 | S&F in repair 240V, 10KA\"C\" curve miniature circuit breaker (MCB) of single poles(SP) and current carrying capacity 6 amp to 32 Amp with breaking capacity 10 KA ,in the MCB DB with connection testing and commissioning complete all as specified and as directed. |
| 23 | S&F for distribution board (DB) made out of steel sheet metal enclosure (CRCA sheet) dust and vermin proof Triple pole and neutral(TPN) 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar 415volts ,flush to wall including taking down carefully existing unserveciable /old main switches, DBS along with MCBs complete all as specified and directed. |
| 24 | S&F in repair 415V, 10KA\"B\"curve miniature circuit breaker (MCB) of triple poles and neutral (TPN) and current carrying capacity 40 to 63 Amp with breaking capacity 10 kA,in the DB with connection testing and commissioning complete all as specified and as directed. |
| 25 | S & F in repair MCCB, 4 pole, 415 V, fixed type, 125 Amps with breaking capacity 16 kA, duly ISI marked, complete all as specified and directed. |
| 26 | S & F in repair energy efficient steel body Ventil Air-DS type Exhaust fan of 300 mm sweep blade with louvers shutter,frame single phase ,230 V,50 Hz,1200 RPMAC ,copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified & directed. |
| 27 | S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified. |
| 28 | S&F Inveter LED bulb of capacity12 watts lumen out put (1200) length 140 mm width 70 mm base cap B22 ,3 star,(ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge. Make Bajaj/Philips/CG |
| 29 | S&F in repair LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 30 | S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge. |
| 31 | M & L for sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V includingsuitable size PVC casing-N- caping, medium grade ISI marked with all accessories such as tees,elbow,junction box etc.,, as required, fixed on surface of wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down of existing sub main wiring complete all as specified& directed.Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing -N- capping shall be measured as one RM. |
| 32 | S&F in repair 1100 V grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVCtapeand overall PVCsheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular of size 10 sqmmtaking down of existing service cable completeall as specified and directed |
| 33 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate No.3 of SSR part I including necessary excavation and earth work in any type of soilchamber with PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate),40 mm thick pre cast RCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate)cover with TMT8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note :Notes: -(i)Earth lead & protection pipes length upto & including 7.50 metre.(ii)Earth filling shall be done by vegetable soil.(iii)Soil should be free from stone, boulders, aggregate, gravels etc. (iv)The rate is inclusive of necessary earth work, returning, filling in and removal etc |
| 34 | M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut ,bolts andincluding provn for fixing 01 no of single pole MCBs 6-32 amps,10KA‘C’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent. |
| 35 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. |
| 36 | Removal of surplus excavated spoilnot exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 37 | Returning, filling in including spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L sand filling in cable trenches for cable protection for clean dry sand unwashed including gently punning in a layer of 15 cm and 8 cm (total 23 cm) inthickness all across the laid portion of LT cable in trenches complete all as specified and directed. (Note:-Punned thickness shall only be considered for payment) |
| 39 | Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm,complete all as specified and directed by the Engineer-in-Charge. |
| 40 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form worketc complete all as specified and directed |
| 41 | M&L for plain cement concrete 1:3:6 type C-2(using 40 mm gradedcrushed stone aggregate) as in foundations for tubular post ,filling & mass concrete etc complete all as specified and directed. |
| 42 | M&L for plain cement concrete 1:4:8 type D-2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. |
| 43 | Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area35 Sq.mm, 3.5 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc including taking down existing cable complete all as specified and directed.(Note:- 1. Excavation & earthwork shall be measured & paid seperately under respective item of BOQ.(2) All Necessary T & P required shall be arranged by the Bidder.(3) Sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 44 | Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area16 Sq.mm, 4.0 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc including taking down existing cable complete all as specified and directed. (Note:- 1. Excavation & earthwork shall be measured & paid seperately under respective item of BOQ.(2) All Necessary T & P required shall be arranged by the Bidder.(3) Sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 45 | Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area4 Sq.mm, 2.0 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc including taking down existing cable complete all as specified and directed. (Note:- 1. Excavation & earthwork shall be measured & paid seperately under respective item of BOQ.(2) All Necessary T & P required shall be arranged by the Bidder.(3) Sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 46 | Supply and erection of steel tubular pole swaged type 410-SP -31 (09.0 mtr long pole) swan neck type complete conforming to IS: 2713 complete with mild steel base plate, finial taper plugpole cap, mild steel bolt, nuts and screws,painting of pole externally with one coat of black bituminous paint (upto planting depth) and remain exterior portion of the pole shall be painted with two coats of aluminium paint over a coat of primer with blue & white strip upto 1.20 m height above GL and all as specified and directedwith two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 5 Nos with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / coping upto the height of 1.5mtrabove plinth block,writing letter or figures (Block Roman) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, Paintingcoping with two coats of cement based paint etc & also including dismantling old and unserveciable prestressed concrete poles/steel tublar poles of any type including breaking cement concrete complete all as specified and directed.NOTE : (i)All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture\"s test certificatefor pole shall be produced before execution work. |
| 47 | Supply, erecting in position steel tubular swaged pole (410 SP-31), 9.00 Mtr long confirming to IS-2713 complete with cast iron base plate, finial taper plug, pole cap, bolts, nuts, screws and washers, welded and reduced section and longitudinal weld throughout entire length of pole including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including above GL and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / coping and writing pole numbers with bold letters with black and white paint Paintingcoping with two coats of cement based paint etc & also including dismantling old and unserveciable prestressed concrete poles/steel tublar poles of any type including breaking cement concrete complete all as specified and directed.NOTE : (i)All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture\"s test certificatefor pole shall be produced before execution work. |
| 48 | S&F for GI water tubing medium grade, ISI marked, galvanised, 80 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for cable protection at road crossing/under concrete including taking down of old one and making good the surfacecomplete all as specified & directed. |
| 49 | S&F for GI water tubing medium grade, ISI marked, galvanised, 50 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for cable protection at road crossing/under concrete including taking down of old one and making good the surfacecomplete all as specified & directed. |
| 50 | Supply and fixing 90 W LED street light, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device including taking down of old one complete all as specified and directed. |
| 51 | S & F LED post top 35 Watt with decorative circular design compliant to dark sky norms with polycarbonate opal diffuser and IP65 protectionincluding taking down of old one complete all as specified and directed. Note : Nuts, bolts, washers including other fixing materials is included in the unit rate. |
| 52 | S&F fountain kit complete including flate jet spray brass nozzle 18 Nos, cascase, filtration system , spray ring, pump , bottom drains and decorative elements and connection pipe of suitable size ring type (appx four meter ring dia) eteincluding taking down of old one complete all as specified and directed. Note : Nuts, bolts, washers including other fixing materials is included in the unit rate. |
| 53 | Supply and fixing LED flood light luminaries of 120W, with pressure die cast aluminium housing with sealed toughened glass cover in frame ,IP 65 protection andwith all fixing arrangement , nuts, bolts and washer connecting to electric system with 2.5 Sqmm PVC Aluminium stranded conductor 2 core up to require length and to be fixed on 11 Mtr longpole including taking down old unserviceable fitting any type and description complete all as specified and directed. |
| 54 | S&F in replacement of landscape cylindrical shape LED bollard warm white light 10 watt IP 66 with integrated driver, including reqd PCC foundation and establishing on ground connecting to the existing cable and make it functional all as specified and directed at site. |
| 55 | S&F in replacement of aluminium strip 25 X 3.15 mm with saddles, DNB insulator and fixingscrews washer etc for roof conductors and down conductors above ground complete all as specified and as directed. |
| 56 | S&F in repair for Test point terminal block of size 175 mm x 120 mm x 80 mm made out of 2.0 mm thick hot dip galvanisied sheet drilled and screwed including 4 Nos 125 mm long hexagonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 57 | M & L earthing complete with Gl electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X 6mm(up to 7.5 mtr length on earth plate) as earthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwedincluding 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip includinglaying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x6mm mild steelangle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm gradedcrushed stone aggregate) reinforced with 8mm dia TMTbars @ 75mm C/C both way with mild steelhandle 12 mm dia round bars ,10mm thick plastering withcement mortar(1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing &taking down old unserviceable earthing any type/any description complete all as specified and directed. .Note: Earth stripand its protection pipe up to and including 7.5 mtr only from the top of earth electrode. |
| 58 | S & F in repairfor Air termination, single pointed aluminium rod 12mm dia and 300mm long with DNB insulatorscomplete all as specified and directed. |
| 59 | S& F in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 mm X 4 mmgalvanised iron strip including necessary clamps ,nuts,bolts ,DNB insulators& hylem sheet block complete all as specified and directed. |
| 60 | M&L for rendering 15 mm thick on external surface ofbrick masonry/concrete surface etc incement mortar(1:4) surface finished even & smooth without using extra cement complete all as specified and directed. |
| 61 | M & L for framed work for valve pit chamber cover made of MS equal angle and MS sheet 3 mm thick including welding, cutting, hinges, locking arrangements including paintingcomplete all as specified and directed. |
| 62 | S&F 12 watt LED spike light ,3000K,IP65,complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 63 | S&F 6 watt LED spike light ,3000K,IP65, complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 64 | S&F 5 watt LED spike light ,3000K,IP65, complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 65 | S&F 5 watt LED spike light ,Red COLOUR,IP65, complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 66 | S&F 5 watt LED spike light ,Blue colour,IP65, complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 67 | S&F 5 watt LED spike light ,GREEN CLOUR,IP65, complete all as specified and directed. Make:Philips/Orient/Bajaj /Crompton Greaves/Havells |
| 68 | M&L for installation, commissioning & testing in provision of plinth mounted LT Feeder Pillar Box No. 01 outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40 mm x 40 mm x5 mm grouted/embedded in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. 01) : -(i) Digital volt meter 0-500 volt, AC 3 Phase with inbuilt selector switch of size 96 x 96 sq. mm- 01 No, (ii) Digital Ammeter 0-200 Amps, AC 3 Phase with inbuilt selector switch with CTs of suitable capacity -01 No, (iii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three), (iv) Panel instrumental wiring with FRLSH 4 sqmm to 6 sqmm copper conductor cable single core of required length - 01 Job, (v) MCCB 100 Amp, Four pole, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (as incomer), (vi) MCCB 40 Amp, Four pole , 50Hz, 415 Volts with repturing capacity 10KA, adjustable thermal magnetic type - 03 No., (vii) MCB TPN 20 Amp,C series, 50 Hz, 415 V with rupturing capacity 10KA - 02 Nos,(viii) MCB DP 32 Amp,C series, 50Hz, 240Volts, ruturing capacity 10KA - 03Nos .Note : (a) The height of panel should be 0.60 mtr(minimum) from ground level with PCC foundation.(b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. |
| 69 | M&L for painting to existing steel tubularLT poles, 8.5m/9m/9.5m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality dust proof and weather proof of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers with bold letters with black and white paint after painting complete all as specific and asdirected. |
| 70 | Supplying and fixing aluminium bus bar of different size and capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacement (taking down old bus bar) complete all as specified and as directed. |
| 71 | Removing wild grass, vegetation, creeper etc aroung LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 72 | S&F in replacement of LT bus bar chamber box of minimum size 70 cm x 50cm x 30cm outdoor type double door front/rear opening type suitable for 415 volt 3 phase, 4 wire (100% neutral), 50 Hz supply system Boxmade out of 3.15 mm (outer) & 2 mm (inner compartment door) CRCA sheet factory made weather proof, dust proof and vermin proof duly powder coated with 04 Nos, copper bus bar 100Amps 40 cm each (each bus bar having 04 Nos of nuts, bolts, washer) horizontallyplace in insulator suitable for lockable door arrangement complete with inter connections with copper solid strips, bus bar chamber having 4 Nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) and 30 cm clear space fromcomplete all as specified and directed. |
| 73 | S&F in replacement of off load changeover switch 415 volt in sheet metal encloser 4 pole of capacity 100 Ampcomplete all as specified and directed. |
| 74 | S&F of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm².Test Parameter:a.Lightning impulse current of 100kA for 10/350 µsb.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm²d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL(Article No. 400 008) |
| 75 | S&FofNylon Conductor Holder for side wall for holding 8 mm dia Aluminium alloy roundConductor.CAPE Type: PCH 8-L(Article No. 440 006) |
| 76 | S&F ofNylon roof conductor holder for flat roof with concrete block for fixing8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surfaceat every 1 mtr. CAPE Type: MBPCH 8-L(Article No. 440 008) |
| 77 | S&F of Top holder and bottom plate- Stainless steel SS 304 Grade Metal roof holder as per sheet profile for 8-10 mm dia Aluminium alloySolid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305.Test Parameter:a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4 CAPE TYPE: MRMCH 8-10 (Article No. 402 230)(OR)CAPE Type: FSCH 14-8 (Article No: 440 011) |
| 78 | S&F of Adhesion Glue for fixing metal roof conducter holder over the metal surface to meet the requirment of IS/IEC - 62305.CAPE Type: AG10(Article No. 400 411) |
| 79 | S&F of Stainless steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction.Test Parametera) Mechanical Loadb) Electrical Testc) Environmental Test Tested for IEC 62561-1CAPE Type: MPC 8-10 SS (Article No. 420 022) |
| 80 | S&F of Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor.CAPE Type: EPC 8 (Article No. 401 209) |
| 81 | S&F of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Test Parametres:a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1CAPE Type: CJ 8 (Article No. 401 211) |
| 82 | S&F of air termination rod of2 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 2 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist CAPE Type: VATF2 (Article No. 401 420) |
| 83 | S&Fof 2 meter length Vertical Air terminal of material AlMgSi of diameter 16/10mm crimped on both the ends (Tappered Type) with necessray supporting and fixingAccessories to mount the Air terminal over the pole, Selected as per Protection Rolling sphere method to meet the requirement of IEC 62561CAPE Type: VAT 2 (Article No. 400 420) + CAPE Type: ITVAT (Article No. 400 405) + SUPPORTING ACCESSORIES |
| 84 | S&Fof 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in down conductor system . Cross sectional area of conductor should be 50 mm².Test Parameter:a.Lightning impulse current of 100kA for 10/350 µsb.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm²d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL(Article No. 400 008) |
| 85 | S&F ofNylon Conductor Holder for side wall for holding 8 mm dia Aluminium alloy roundConductor.CAPE Type: PCH 8-L(Article No. 440 006) |
| 86 | S&F of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning eventsButtons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.CAPE Type No: PRO LER(Article No. 400 999) |
| 87 | S&Fof Stainless Steel Test Joint to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter:Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1CAPE Type: TJRR -G1(Article No. 420 013) |
| 88 | S&Fof Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil.Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional areafor 1 sec (IS3043/IEEE80);b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 70µm. Tested as per IEC 62561-2.CAPE Type: SRC 10 CuB (Article No. 400 010) |
| 89 | S&FofStainless steel SS 304 Grade Conductor Holder for fixingthe 8 -10 mm dia round conductor on thewall . Test Parameter:a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4CAPE Type: CH 8-10 (Article No. 400 213) |
| 90 | S&F of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. CAPE Type No.CBR 1410 (Article No. 300 010)Supplyof CAPE make earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kgCAPE Type: PROSAN 25(Article No. 300 832) Supply of CAPE make Earth rod clamp made up of SS Material for terminating cable / flat conductor.CAPE Type: ERC 1417 SS (Article No. 300 463) + CAPE Type: CPES 8 (Article No. 401 504)Supply of CAPE make Earth Chamber Inspection Pit made up of Plastic withstand load of 60kN with the dimention of 290*290*209mmCAPE Type: EC 290(Article No. 300 852) |
| 91 | S&F surge protection device suitable for distribution box of capacity 6/8/12 wayNominal AC voltage-240VMaximum Continuous Operating Voltage- 300V(L-N)/305V(P-NE) Nominal Discharge Current - 20Ka(L-N)/50Ka(P-NE)Impulse Discharge Current -12.5Ka(L-N)Voltage Protection Level -1500V (L-N)Response Time -<100ns(L-N) Over Current Protection - 315 A Shortcircuit protection -25KA/50KA TOV With stand 120Min. -442V(L-N) TOV With stand 200ms.-1200V(N-PE) Model - T1H-300-3+1-R |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail