Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) in all kind of soil over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed by Engineer-in-charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) in all kind of soil over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 1.5m and not exceeding 3.0m, complete all as specified and as directed by Engineer-in-charge. |
| 3 | Removing excavated materialexc. 250 m and Not exc 500 mdepositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 4 | M&L forPCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concretecomplete all as specified and as directed. |
| 5 | M&L Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as speified. |
| 6 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified. |
| 7 | M&L Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) in columns, pillars ,piers, posts and struts complete all as specified and as directed. |
| 8 | Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions squre, rectangular or polygonal complete all as specified. |
| 9 | M&L for moorum filling in floors or paving, laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 10 | M&L for hardcore of gauge not exc 63 mm size of broken stone or boulder, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 11 | M&L for 100mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floors and pavingscomplete all as specified and as directed. |
| 12 | M&L Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) as in beams, cantilevers, bressummer lintel over 1.5 m spancomplete all as specified and as directed |
| 13 | M&L Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 14 | M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in chajjas complete all as specified and as directed |
| 15 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified. |
| 16 | Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified. |
| 17 | Use and waste formwork to edges of concrete roofs exec 10 cm but n exc 20cm wide for fair finished surfaces and similar workfor rough finished surfaces of concrete complete all as specified and as directed |
| 18 | Use and waste formwork to chajjas, trough and simmilar items including edgesfor rough finished surfaces of concrete complete all as specified and as directed |
| 19 | M/L forDamp proof course to horizontal or vertical surface including necessary formwork of 40 mm thick in PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate mixed with integral water proofing compound conforming to IS-2645. |
| 20 | M & L for Mild steel bars 10mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 21 | M & L for Mild steel bars TMT Bars 5mm and over upto and including 10mm dia in stirrups spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 22 | M and L for brick work fly ash brick with old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 23 | M&L for AAC block masonry , Grade-I (Min compressive strength 5N/Sqmm), Density 651-750Kg/Cum and shall be laid using polymer modified and curing free ready mix jointing mortar of joint thickness 3mm to 4mm complete all as specified and as directed.Note: Size of AAC blocks shall be as per site requirement andto be approved by GE. |
| 24 | M&L for rendering 10mm thick single coat ready mix plaster as per manufacturers instruction onfair faces of brick work or concrete surfaces, finishedsurfaces even & smooth complete all as specified and as directed. |
| 25 | M&L for rendering 12mm thick single coat ready mix plaster as per manufacturers instruction on fair faces of brick work or concrete surfacesfinished even & faircomplete all as specified and as directed. |
| 26 | M&L for rendering 5mm thick single coat ready mix plaster as per manufacturers instruction 1:3 on fair faces ofconcrete surfaces in ceiling including finishing even & smooth complete all as specified and as directed. |
| 27 | M&L for preparation of new plastered wall surfaces and applying two coat of 100% premium exterior acrylic emulsion paint, alkali & fungal resistance, dirt resistance on over a coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge.. |
| 28 | M&L for preparation of new plastered surfaces of walls and applying 1.5 to 2mm thick wall care putty to achieve smooth surface, sanding the surface and applying two coats of acrylic distemper of approved shade/tint over a coat of interior acrylic primer complete all as specified and as directed. |
| 29 | M&L for preparation of new plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed . |
| 30 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 100 x 50 mm comprising of virgin PVC polymer of K value 58-60 (Suspension grade), Calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/Sqmm, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per specified and as directed.Note: (i) Minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable for WPC solid door/window frames. Variation in profile dimensions on plus side shall be acceptable without any extra cost to the department. |
| 31 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension grade), Calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/Sqmm, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per specified and as directed.Note: (i) Minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable for WPC solid door/window frames. Variation in profile dimensions on plus side shall be acceptable without any extra cost to the department. |
| 32 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative flush/panel door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 33 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative flush/panel door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 34 | S&F 100 mm size butthinges medium weight, stainless steel and fixed all as specified and as directed. |
| 35 | S&F 150 mm size aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and as directed. |
| 36 | S&F 150mm size aluminium alloy handles, fabricated type extruded section, ISI markedcomplete all as specified and as directed. |
| 37 | S & F 200 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed. |
| 38 | S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed. |
| 39 | S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 150mm length of cover plate,complete all as specified and directed. |
| 40 | S&F in repair powder coated anodised aluminium ventilator having aluminium section weighing not less than 0.55 kg/m, including aluminium louvers, frosted 3mm thick glass, SS wire mesh, including arrangement for fixing of exhaust fan and necessary joining cleats,glazing clips,screws etc complete all as specified and as directed.Note :Size and Shade shall be as approved by Engineer-in-Charge. |
| 41 | S&F mild steel framed work such as grills, framed guard bars and similar work conforming to Fe-290.Gde-E-165, welded to steel ventilators & window complete all as specifiedand as directed. |
| 42 | M&L for 30mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in levelling course/sub base of floors and pavingscomplete all as specified and as directed. |
| 43 | M&L for non skid coloured ceramictiles 7-8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15mm thick screed bed in CM 1:6 etc complete all as specified & directed.Note: Color and shade shall be as approved by Engineer-in-charge |
| 44 | M&L for glazed coloured ceramic tiles in vertical surfaces as dado of size450x300x6-7m, thick set and jointed in neat cementand pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on other than fair faces of brick work etc complete all as specified & directed.Note: Color, size and shade shall be as approved by Engineer-in-charge |
| 45 | M&L 18 to 20mm thick pre-polished granite stone slab of approved shade and colour as in table top, top of WHB, kitchen slab/platform, gate pillars, cills etc or on vertical surfaces including vertical projection, urinal partition, including full round moulding the edge, laid overand including screed bed 15mm thick in cement mortar 1:4jointing, pointingin white cement 1:2 using marble dust with admixture or pigment to match the shade of granite and rubbing, polishing to achieve mirror finish complete all as specified and as directed.Note : Colour and shade shall be asapproved by GE. |
| 46 | M&L for machine cut cudappah stone slab 20-25mm thick laid over and including 20 mm thick bedding layer of cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 47 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed. |
| 48 | M&L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregates) as in paltform for water tank, coping, kerb, cills, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed. |
| 49 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Surface roughening concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying cement slurry @3kg/Sqm.(ii) Screed bed or bedding layer of mortar 1:3 in 10 mm thick for laying as in roof slab withincluding mixing of WPC (as per manufacturers instruction) and surface finished fair and smooth without using extra cement.(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum),weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be laid/ applied over bituminous primer as specified above, andapplication of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying two coat of bituminous aluminum paint over the APP modified membrance @ 0.11Kg/sqm.Note: Water proofing compound shall be measured separately and paid under respective item of BoQ. |
| 50 | Supply only liquid water proofing compound complete, ISI mark all as specified and as directed. |
| 51 | S&F rotational moulded polyethylene water storage tanks colour white(cylindrical vertical with closed top), 1000 litres capacity, tripple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting (Min weight of ball valve 210 gms) complete all as specified and as directed. |
| 52 | S&F 15mmbore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 53 | Cutting chases n. exc 10 cm in girth, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc complete all as specified and as directed. |
| 54 | S&F 20mmbore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 55 | S&F bib tap 15mm dia, fancy type, with wall flange and aerator screwed down for iron pipe or for brass ferrule complete all as specified and as directed.Make : Cat No. F1015151 of CERA or equivalent model of makes specified. |
| 56 | S&F two way bib tap 15mm dia, fancy type, with wall flange and aerator screwed down for iron pipe or for brass ferrule complete all as specified and as directed.Make : Cat No. F1015161 of CERA or equivalent model of makes specified. |
| 57 | S & F angle valves/stop valves, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.Cat No. F1015201 of CERA or equivalent model of makes specified. |
| 58 | S & F stainless steel grating with square frame (grating thickness 1mm and frame thickness 1.5mm) of size 125mm (minimum) with waste hole complete all as specified and as directed. |
| 59 | S&F, Health faucet (ABS Body)suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.Make : Cat No. F8030111AB of CERA or equivalent model of makes specified. |
| 60 | S&F 10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white with inlet ball valve and handle including brackets, PVC connection pipe 450mm long, etc completeall as specified and as directed.Make : Cat No. B1010110of CERA or equivalent model of makes specified. |
| 61 | S&F vitreous china wash down water closet (pedestal pattern) white, including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed.Make : Cat No. S1053102of CERA or equivalent model of makes specified. |
| 62 | S&F vitreous China, white, squatting pan, Orissa pattern of size 580 X 440 mmwith integral foot rests (excluding flusing cistern)includingtraps &set in cement concrete as specified including flush pipe and connecting to trap complete all as specified and as directed. |
| 63 | S&F vitreous china wash hand basin, white, counter sunk, of size 520 mm x 450 mm x 200 mm, including pillar tap, 15 mm bore chromium plated, fancy type, cast copper alloy with capstan head, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks, 32 mm waste coupling brass chromium platedsuitable for wash hand basins, with long screwed shanks and fly nuts andPVC waste pipe, 15mm dia PVC connection pipe 450mm long complete all as specified and as directed.Make : Washbasin Cat No. S2030101 of CERA & Pillar tap Cat No. F1015101 of CERAor equivalent model of makes specified. |
| 64 | S&F Soap dish, chromium plated,fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed. |
| 65 | S&F vitreous China bowl type (flat back type) white with grating and union for discharge pipe (excluding flushing cistern, flush pipe)including urinal spreader of brass chromium plated for fixing with 15 mm dia pipe, PVC connection, 40mm PVC waste pipe & 40 mm waste coupling providing and fixing plugs, bedding urinal against wall in mortar 1:2, securing urinal to plug, with and including 60mm long screws, pointing around urinal back in cement, fixing flush pipe complete all as specified and as directed.Make : Cat No. S4020104Carys of CERA or equivalent model of makes specified. |
| 66 | S&Ftowel rail60 cm long between flangescomplete all as specified and as directed.Make : Cat No. F5015103CH of CERA or equivalent model of makes specified. |
| 67 | S&F 5mm thick bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated screws and cup washers complete all as specified and as directed. |
| 68 | S&F, 100 mm dia PVC(SWR) multi floor trap including jointing to waste pipe with solvent cement complete all as specified and as directed. . |
| 69 | S&F, 75 mm dia PVC(SWR) nahani/floor trap including jointing to waste pipe with solvent cement complete all as specified and as directed. . |
| 70 | S&F, PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 71 | S&F 110 mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixd to wall or laid in trenches or in floorsincluding clamps for securing pipe complete all as specified and as directed. |
| 72 | S&F PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls or laid in floors complete including clamps for securing pipe complete all as specified and as directed. |
| 73 | S&F 110 mm dia PVC (SWR) bends of any radiuscomplete all as specified and as directed |
| 74 | S&F PVC (SWR) 75mm dia in junction single, (Bend) equal or unequal complete all as specified and as directed. |
| 75 | S&F 110 mm dia PVC (SWR) bends with access door of any radius, complete all as specified and as directed. |
| 76 | S&F PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 77 | S&F PVC (SWR) 75 mm bore vent cowl complete all as specified and as directed. |
| 78 | S&F PVC (SWR) 110 mm bore vent cowl complete all as specified and as directed. |
| 79 | Earth work in excavation by mechanical means (Hydraulic excavator) in ordinary rock over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed by Engineer-in-charge. |
| 80 | Earth work in excavation by mechanical means (Hydraulic excavator) in ordinary rock over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 1.5m and not exceeding 3.0m, complete all as specified and as directed by Engineer-in-charge. |
| 81 | M&L Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 82 | Use and waste of formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work etc.,vertical or to batter complete all as specified and as directed. |
| 83 | M&L for rendering 15 mm thick onother than fair faces of brick work /concrete surfacesin cement mortar 1:4, mixed with liquid water proofing compound, finished even and fair without using extra cement complete all as specified and as directed. |
| 84 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling finished the surface even & smooth without using extra cement complete all as specified & directed. |
| 85 | M&L for machine cut kota stone flooring, 18-22 mm thick( minimum size of kota stone slab 16\"x22\" ) laid over and including 20 mm thick bedding layer of cement mortar 1:6 jointed with grey cement slurry mixed with pigments to match the shade of slab including cutting, rubbing and mirror polishing including removing dust complete all as specified and as directed. |
| 86 | M&L mild steel as in Roof trusses (framed), trussed purlins, Post, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.FE 410 W (Gde E-250) quality - Bas specified and directed. |
| 87 | M&L Mild steel plates (plain or chequered) channels, sqares cut or notched (ordinary and countersunk) forming holes without any attachment. Fe 410 W Gde E -250 quality - B all as specified and directed by Engineer-in charge |
| 88 | M&L Mild steelbolts, purpose madeor machine made (as per site requirment) screwed one end or both ends , with hexagonal or squre nuts and washers exc 12 mm dia but not exc 20 mm dia, exec 30 cm long,complete all as specified and directed by Engineer-in charge |
| 89 | M&L Mild steel flats bands straps etc for hold fasts wind tiesetc.conforming to Fe 290 Gde E -165 all as specified and directed by Engineer-in charge |
| 90 | S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated steel sheets0.5 mm thick of any colour, AZ 150 coating having tensile strength 550 MPA as in roof covering orridges with side lap and end laps, hips and straight flashing fixed with self taping screws (length & girth as fixed) complete all as specified and as directed. Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 91 | S&F pre-painted galvalume aluminium zinc coated galvanised Iron based Plain steel sheets, 0.5mm thick of any colour, AZ 150 coating, with side lap and end lap having tensile strength 550 MPA as in ridges, hips, valley gutters, drip and straight flashingfixed with self taping screws (length & girth as fixed) complete all as specified and as directed.Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 92 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 93 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed. |
| 94 | S&F rotational moulded polyethylene water storage tanks colour white(cylindrical vertical with closed top), 5000 litres capacity, tripple layered, hoisted and fixed in position including 25 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting (Min weight of ball valve 455 gms) complete all as specified and as directed. |
| 95 | M&L for application of acrylic cementitious two component water proofing coating on floors/walls in two coats as per manufacturers instruction complete all as specified and directed by Engineer-in charge Note: Make of acrylic cementitious two component water proofing to be approved by GE |
| 96 | S&F600 mm x 450 mm, bevelled edge mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 97 | M&L Laying and compacting 200 mm thick (compacted thickness) Granular Sub Base Course GSB) grading as per Grade I as specified Table 400-1 of MoRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natura sand, crushed gravel,crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KNstatic weight for achieving required compaction density of atleast 98% of theMaximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013. |
| 98 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stoneaggregates) as in sub-base of floors/pavings, complete all as specified and as directed. |
| 99 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 100 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded stoneaggregates) as in copings, kerbs,etc including weathering slightly rounded or chamfered angles and throating including necessary formwork , complete all as specified and as directed. |
| 101 | M & L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper mbedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping complete all as specified and directed. |
| 102 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains or laying of pipe or for shafts, wells cesspits,man holesetc (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 103 | Returning filling-in including spreading, levelling, watering andwell ramming in layers not exceeding 25cm using approved excavated soil all as directed. |
| 104 | M&L thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate )as in coping/ benching including form work floor finishes cement concrete surface even and smooth with out using extra cement complete all as specified and as directed. |
| 105 | M&L for 15 mm thick rendering in cement mortar 1:4 on with water proofing liquid as per manufacturers instruction other thanfair faces of brick masonary surfaces orconcrete surfaces, finished even and fair without using extra cement complete all as specified and as directed.(Note : Water proofing Liquid to be measured and Paid separately) |
| 106 | M&L for supply, laying, jointing and testing of RCC pipes, 200 mm bore dia, class NP2, laid in trenches and jointed with collars in cement mortar 1:1, complete all as specified and as directed. Note:- (a) Excavation, earthwork and PCC bed concrete shall be measured and paid for seperately under respective item. |
| 107 | M&L for PCC 1:4:8, type D-2, using 40 mm graded stone aggregates as in concrete bed for 200mm bore dia drain pipes, any type,including packing under and haunching against the sides of the pipes after they are laid & tested complete all as specified and as directed. |
| 108 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete ,using extra cement ,includding forms ,moulds mitered/stopped ends etc. complete all as specified and as directed. |
| 109 | M&L for providing precast cement concrete 1:2:4 type B-1 using 20 mm graded aggregate asin cover slab of manhole, soak well & septic tank and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4, complete all as specified & directed. |
| 110 | M&L PCC 1:2:4 type B-1 (using 20 mm graded aggregate )as in coping/ benching including form work floor finishes cement concrete surface even and smooth with out using extra cement. |
| 111 | M&L for construction of soakage well (3.0 m dia x 4.50 m effective depth) including excavation in any type of strata (soil or any type of rock),foundation in PCC 1:3:6, walls of honey combed masonry with top slab in RCCM-25 concrete including intercepting chamber andscreen chamber made of brick masonry in cement mortar 1:4,RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC, complete filled with brick bats of required size complete all as per Drawing No CEPZ/2019/TD/03 sheet 1/2 & 2/2 with andcomplete all as specified and as directed |
| 112 | M&L for construction ofRCCSeptic tank(conventional ) (for 150 users) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connectioneffective depth is 1.5 mtr and over all depth 3.0 mtr etc., complete all shown on TD DRG AFB/TD/228/2018(5) sheet 1R/1 with andcomplete all as specified and as directed |
| 113 | M & Lfor PCC 1:3:6 Type C1 using 40mm graded stone aggregates as incopings of surface channels and drains including necessary form/mouldcomplete all as specified and as directed. |
| 114 | M&L for rendering 15 mm thick onother than fair faces of brick work /concrete surfacesin cement mortar 1:4,finished even and fair without using extra cement complete all as specified and as directed. |
| 115 | Mateial and labour for 50 mm GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, Washing out complete all as specified and directed. |
| 116 | Mateial and labour for 25 mm GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, Washing out complete all as specified and directed. |
| 117 | Material and labour for 50 mm Gun metal or Bronze globe / ball valve, ISI Marked,screwed both ends suitable for GI tubing with side way operating GI lever handle complete all as specified and directed. |
| 118 | Material and labour for 25 mm Gun metal or Bronze globe / ball valve, ISI Marked,screwed both ends suitable for GI tubing with side way operating GI lever handle complete all as specified and directed. |
| 119 | M&L for construction of valve pit/chamber ofInternal dimensions 600 mm x 600 mmx 600 mm, using PCC 1:4:8, type D-2, using 40mm graded stone aggregates for foundation, 23 cm thick, brick wall built in cement mortar (1:4) ,15 mm thick rendering all around the brick work in cement mortar (1:6), 75 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates in coping including necessary form work, 3 coats of white wash on rendered surfaces and on coping, 5 mm thick mild steel top sheet cover with frame made out of 40x40x6 mm angle iron, locking arrangement,including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 120 | M & L for Cutting existing 150 mm dia DI pipe for inserting Tee of size 150x150x50 mm including lead joint and excavation etc complete all as specified and directed |
| 121 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50 mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24,450 N laid in trenches for cable protection complete, all as specified and as directed |
| 122 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable,of size 10 sqmm2 core with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathedincluding cablegland, lug, jointingmaterialetc,jointing, connecting ,testingandcommissioning allasspecified and directed. |
| 123 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990,PVC insulated andsheathed , FRLSH cable laid / fixed and including concealed in PVC rigid conduit of suitable size (20/25 mm) on walls/ceiling along with 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and sheathed FRLSH cableas earth wire connected to common earth dolly at one end and metallic bodies of luminaireat other end including Sunken boxes, Modular cover plates of suitable sizesfor mounting Modular switches, sockets, fan Regulators, accessories etc. all as specified and directed for one light point controlled by one, one way switch .NOTE :- 1. Proper colour coding shall be adopted for wiring (for phase-RED, YELLOW, BLUE for Earth-Green and Neutral-Black) 2. All points shall be earthed up to fixtures etc. |
| 124 | All as per serial item No. 123 here-in-before but for one Ceiling fan/Exhaust fan point controlled by one, one way switchas specified. |
| 125 | All as per ser item No. 123herein before but One 6 Amp 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 126 | S&F of ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & asdirected. |
| 127 | S&F of modular switch one way, 6 Amp, one module, 230V all as specified and directed. |
| 128 | S&Fof modular socket, 6A, 2-3 pin combined 2 module, 230V all as specified and directed. |
| 129 | S & F square profile LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 20 Watt with LED light source 6500k with uniform light output,with all accessories including its connection complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS LED PRIDE ESSENTIAL Cat No LHEXAWP7UN1W020or equivalentapproved make |
| 130 | Supply and fixMCB SP, AC 240 V,6 to 32 Amps 10 KA capacity ,\"c\" series making connection with suitabl size of copper lugs etccomplete all as specified and directed by engineer-in-charge. |
| 131 | S&F MCB SPN, AC 240 V, 32Amps, 10 KA capacity ,\"c\" series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. |
| 132 | Supply and fixsheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 8 wayprotection class IP-42,suitabl for fixing MCBs,Isolators etc,confirming As per IEC 61439-3,suitable for flush mounting and surface mounting,with 100 Amps rated copperbusbar,with Neutral bar,Earthbar and cable alley for cable managment,fully shrouded,Neutral bars,prefittes masking sheet complete all as specified and as directed. |
| 133 | M & L Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI wire 4 mm dia , by means nut bolt, nuts, check nuts and washer of the GI.Earth wire connected upto main earth point/DBs alongwith 15mm diaincl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. |
| 134 | S&F metallic body with metallic blade & brackets, ISI marked exhaust fan, 300 mm sweep, min 1325 RPM, min air delivery 1050 CMHwith louvers to prevent entry of mouse & birds and connecting up including provision of three core flexible copper wire of size 1.5 sqmm from ceiling rose to exhaust fan complete and fixing on wall with necessary bolts, nuts , washers,etc complete all as specified and as directed by Engineer in Charge. |
| 135 | Supply and fix security light of building with single piece New generation energy saving and environmental friendly long life LED 35W made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07including one bracket made of Light gradeGI Pipe 25 mm dia 1.0 mtr long fixed to wallwith two clamps made out of MSFI 30 mm x 5 mmfixed with anchor bolt and connection all as directed and as specified. |
| 136 | M & L for point wiringcomplete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990,PVC insulated andunsheathed , FRLSH cabledrawn through and including PVC Conduit pipe heavy duty (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLSH cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other endincluding Sunken boxes, Modular cover plates of suitable sizesfor mounting Modular switches, sockets, fan Regulators, accessories etc. all as specified and directedfor one light point controlled by one, one way switch .NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 137 | All as per serial item No. 136 here in before but one 6 Amp 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 138 | Supply and fix sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 4 wayprotection class IP-42,suitabl for fixing MCBs,Isolators etc,confirming As per IEC 61439-3,suitable for flush mounting and surface mounting,with 100 Amps rated copperbusbar,with Neutral bar,Earthbar and cable alley for cable managment,fully shrouded,Neutral bars,prefittes masking sheet complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail