| 1 | Supply and fixing in repair high mast LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 2 | Supply and fixing in repair high mast LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 3 | Supply and fixing in repair LED Solar street light fitting upto 15 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.Note : Excavation & earth work included in deemed rates. |
| 4 | Supply and fix in repair control gear system with winch motor for raising and lowering the lantern carriagefor high mast light upto 20 mtr height complete all as specified and directed. |
| 5 | Supply and fix in repair stainless steel wire rope of 6 mm dia 97/19 guage complete all as specified and directed. |
| 6 | Supply and fix in repair aviation light upto 15 mtr height including connection from light to LT Panel with 1.5 Sqmm twin core copper conductor PVC sheathed complete all as specified and directed. |
| 7 | Supply and fix in repair PVC Insulated 6 Sqmm Three core copper conductor from high mast upto 20mtr height to LT Panel complete all as specified and directed. |
| 8 | S&F in repairs, power contactor upto 20 Amps with 2 NO + 2NC for highmast light complete all as specified and directed. |
| 9 | Supply fixing and testing in repair Street light automatic Nature switch of capacity 5 KW single phase complete with high and low voltage and overload protection, degree of protection confirm to 1P-55 AC, SP complete with suitable size MCB and power contactor etc, fixed on pole with 25 X 3mm MS strip clamp including provision of 6 sqmm 3 core cable for connection complete all as specefied and directed. |
| 10 | M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumpsof capacity OHT reservoir 100000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY including painting work complete all as specified and directed. Make: Rays Cleantech/ Inus watertech/ Satya Enterprise.Location:NSD Mil Stn seven stages are as under plants:-(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system.(b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks.(c). Third strage is fresh water cleaning by high speed jet pump.(d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inchlor-5/NB-10 Govt Laboratory certified brannded halogen compound Or E in C approved equivalent product.(e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g)Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 or EinC approved equivalent product.Cont... Item No 10.01 |
| 11 | (h) Painting the pipelines (inlet, delivery washout, overflow pipes),Valves, Steel ladders etc. with two coats of synthetic enamel paint as per existing colours code complete all as specified and directed.NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHALL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. Cont... Item No 10.02 |
| 12 | Different coulor code shoud be followed as per colour coding direction issued by EIC for painting of inlet, delivery, overflow and washout pipe lines(IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:- (a) THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE SPECILIZED AGENCY details given in Particular Specification. (b) Each tank/reservoir will be measured as one unit (Each Job). |
| 13 | All as per ser item No 10.00 above but inside of OHT reservoir capacity 75000gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed.Location: Mil Stn NsdMake: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE.Note: Each tank/reservoir will be measured as one unit (Each Job). |
| 14 | All as per ser item No 10.00 above but inside of OHT reservoir capacity 50000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed. Location: Mil Stn NsdMake: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE.Note: Each tank/reservoir will be measured as one unit (Each Job). |
| 15 | All as per ser item No 10.00 above but inside of overhead reservoir capacity 40000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAYcomplete all as specified and directed.Location: Mil Stn Nsd Make: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. Note: Each tank/reservoir will be measured as one unit (Each Job). |
| 16 | All as per ser item No 10.00 above but inside of overhead reservoir capacity 35000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAYcomplete all as specified and directed.Location: Mil Stn NsdMake: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. Note: Each tank/reservoir will be measured as one unit (Each Job). |
| 17 | All as per ser item No 10.00 above but inside of overhead reservoir capacity 20000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed. Location: Mil Stn NSDMake: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 18 | All as per ser item No 10.00 above but inside of Under gorund SUMP reservoir capacity 8 Lakh gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed. Location: HD Enclave, Serna Enclave, Ganesh Enclave and Goswami Enclave. Make: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 19 | All as per ser item No 10.00 above but inside of Semi under gorund SUMP reservoir capacity 3 Lakh gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed.Make: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 20 | All as per ser item No 10.00 above but inside of Flocculator capacit 4 Lakh gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed.Make: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 21 | All as per ser item No 10.00 above but inside of Service RCC tankcapacity75000 gallon through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed.Make: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 22 | M&L for preparing the surface by removing the spalled and loose plaster from existing surface and making it sound and clean by removing all dust particle and washing the surface with jet water. Then allowing the surface to dry and check for any cracks, honeycombing and other foreign particle complete all as specified and directed. |
| 23 | M&L for providing, mixing and laying over the prepared surface with cement mortar of average 15 mm thick or as per requirements in proporting 1:3 (1 Cement : 3 Sand) mixed with bonding agent, Nitoband SBR lated @ 5 liter per 50 Kgs of cement and integral waterproofing admixture complast WL of Fosroc Chemicals @ 125 ml per 50 Kg of cement complete all as specified and directed. |
| 24 | Triming of trees,cutting of herbs and shrubsupto ground level,Cleaning of equipment by cotton waste and removingplants and other garbage material from Water supply/electric supply/STP Installation to nearest garbage bin not more than 2 km from site and cleaning of internal road/path through water including repairing of plaster at places complete all as specified and directed. |
| 25 | M&L for collection of water sample from the Pump Houses and STP area getting then tested from approved Govt laboratory (approved by GE) &furnishing test report indicating chemical and bacteriologicalanalysis on monthly basis including presence of fluorine contents if any complete all as specified and directed. |
| 26 | Recharge of SCADA panel data sim (Airtel/Vodafone/JIO)for smooth functioning automation system on monthly/ quarterly/ six monthly basis complete all as specified and directed. |
| 27 | M&L in repair submersible cable 6 Sqmm 3 core, copper and PVC insulated connecting with the pumping set motor carefully including taking down the existing cable complete all as specified and directed. |
| 28 | M&L in repair submersible cable 4 Sqmm 3 core, copper and PVC insulatedconnecting with the pumping set motor carefully including taking down the existing cable complete all as specified and directed. |
| 29 | Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanized ironstrip of size 25 x 4 mm by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe15 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting toCBDB’s as specified or indicated including testing on completion complete all as specified and directed. |
| 30 | M&L for taking out of u/s electric driven pumping set of capacity 5HP, discharge 3 LPS head 70 to 80 meters alongwith GI coloum pipe40/50 mm bore flanged at both side and submersible cable from bore for repair/rewinding the submersible pump set complete all as specified and directed. |
| 31 | M&L for lowering the submersible electric driven pump set of capacity 5 HP discharge 3 LPS 70 to 80 meters head alongwithGI coloum pipe 40 mm bore flanged both side (old & new GI pipe) complete all as specified and directed. |
| 32 | Taking out the burnt copper winding wire from submersible electric motor of capacity 5 HP and rewinding the submersibleelectric motor with super enamelled copper wire of existing gauge complete all as specified and directed. |
| 33 | Disconnecting all the electrical connection,water connection from pump and motor with base plate for transporting the same to repair wksp approvedfor winding and dismantling the motor, cutting and removing the old heated up/burnt winding of the stator /rotor cleaning the slot and rewinding the motor stator/roterwith super enamelled copper winding wire of existing size and gauge and truns etc including all the insulating materials i.e varnish with super high quality of cotton tape insulating paper and other misc items of motor, capacity of motor 150 HP and transportation back the same after winding and reassembling complete of electric motor complete all as specified and directed. |
| 34 | All as per ser item No 31.00but of size 60 HP |
| 35 | Supply and fixing plastic rope 25 mm for supporting of submersible motor with necessary fitting and connection to submersible pump complete all as specified and directed. |
| 36 | Supply and fixing plastic rope10 mm for supporting of submersible motor with necessary fitting and connection to submersible pump complete all as specified and directed. |
| 37 | S&F, in replacement, MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA , including spreader terminals, phase barriers, complete all as specified and directed. |
| 38 | S&F, in replacement, MCCB 4 Pole, 415 V, with Microprocessor release 200 Amps with breaking capacity 36 KA , phase barriers, complete all as specified and directed. |
| 39 | Developing tube wells by compressed air with minimum pressure of 10kg/Sqcm and minimum air discharge 450 CFM all as specified in IS 11189-1985 Para 4.3 complete all as specified and directed.Note: Compressor, pump, pipe and other allied items will be arranged by contractor and no extra payment will made by the department. |
| 40 | Supply and fixin replacement3 Pole Power contactor type MNX with AC coil, rating upto 40 Amps, conformingIS/ IEC 60947-4-1, IP-20,415 Volt, snap fit construction, nut retaining washer for quick terminationand class H insulation complete all as specified and directed. |
| 41 | Disconnecting,dismantling all electrical and water connection of heavy duty Front loaded washing machine of capacity 70 Kg by openingside covers for Servicing/maint of equipment including unserviceable spare parts and refixing the sameafter necessary repair workincluding testing to entire satisfaction complete all as specified and directed.Note Spares are measured and paid seprately under sch items |
| 42 | Rewinding of electrically operated digital control mechanical laundary machine of capacity upto 10 HP including side covers for carrying out complete servicing of equipment and testing complete all as specified and directed. |
| 43 | S&F in repair/replacement ofwater level sensor as per existing make and capacity complete all as specified and directed. |
| 44 | S&F in repair/replacement of contactor MNX-25 of capacity 25 Amps as per exiting make complete all as specified and directed. |
| 45 | S&F in repair/replacement of water heating coils duly proceline insulated of capacity 2 kw as per existing make complete all as specified and directed. |
| 46 | S&F in repair/replacement of functioning control timer as per existing make and capacity complete all as specified and directed. |
| 47 | S&F in repair/replacement of Bearing,shaft and O ring complete all as specified and directed. |
| 48 | S&F in repair/replacement of control switch for PCB of machine complete all as specified and directed. |
| 49 | Disconnecting,dismantling all electrical and water connection of heavy duty drying tumbler of capacity 60 Kg by openingupper/side covers for Servicing/maint of equipment by deep cleaning including changing of v belt A101 -02 Nos and B-78 - 02 Nos inclding all minor repair and refixing the sameafter necessary repair workincluding testing to entire satisfaction complete all as specified and directed. |
| 50 | M & L for servicing and testing of air compressor set of capacity 02 HP, 3 phase 415 volts by opening end cover, replacement connection lead ,greasing the both end of bearings and replacement of bearing ,meteling/policing of shaft,replcing worn out nut bolts ,gasket,air release valve key gland stuffing box male/female set, rubber bush, descalling of impeller and replacing of impellor key & neck ring (impellor guide) and other minor erpair required and painting one coat of synthetic enamal paint with connected LT panel complete all as specified and directed. |
| 51 | Total in Figures |
| 52 | Quoted Amount in Words |