Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for supplying and fixing information board /shock treatment chart etc. of Size 2.0m X 1.0m in power houses /pump houses and other E/M installations as per the requirment at various locations made out of pre laminated board with digital printing,pasting side beadings of decorative aluminium channel with proper fixing arrengement etc. including old board any type all as specified and as directed. NOTE :- (a). Before fabrication of the board, the contactor has to produce a paper printout detailing all dimensions and matter to be displayed so as to get it inspected and passed.(b). Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specificed and asdirected. (c). The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the informatory board at the loaction as specified and as directed. |
| 2 | Material and labour for fabrication, supply, fixing and commissioning of box type display boards of size not less than 1.5 M x 1M x 0.2 M made out of ACP sheet of 3 MM thickness with english alphabets and numerics cut out and designed out of 3 mm thick acrylic sheet neatly pasted on the ACP board with flushed LED strips running along the sides of the acrylic letters to be fixed on wall with necessary fixing arrangements as per the site requirement on roof, wall etc. including taking down old board any type all as specified and as directed.NOTE :- (a). Before fabrication of the display board, the contactor has to produce a paper printout detailing all dimensions and matter to be displayed so as to get itinspected and passed . (b). Matter to be displayed, colour of the ACP sheet and colour of LED strip will be as specified and directed by . (c). The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the diplay board at the installation incl providing electrical connections complete as specified. |
| 3 | Material and labour for earthing complete with pure copper bonded25mmouter dia electrode, including testing 3 mtr long and having suitable hole on top to connect earthing strip with nut bolts and washers burried directly and verticaly in ground with top edge at 30 cm below ground level after making bore hole of 200 mm dia and 3.3 mtr deep using suitable machanical drilling machine connected with copper trip 25x3mm with copper nut bolts and connected to test point from earthing pit. The earthing should be filled with crbon based erthing compound. The resistance of the compoind should be less than 0.1 Ihm. The compound should be highly conductive, hygroscopic, non mgnetic, non corrosive in natur and have best moisture retaining qualities with ph value between 7-9. including reinforced plastic pit not less than 300x300 mm with pit cover, including necessary earth work complete all as specified and as directed. NOTE :- (a) Contractor should visit site before quoting the rates. (b) Rates including demolition of old earthing. (c)Contrctor should provide all necessary safety measures during exectution the job and responsible for any loss to the Govt property during execution the job. |
| 4 | Material and labour for replacement ofaluminium strip 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed . |
| 5 | Material and labourreplacement of galvanised iron (GI) strip 32 X 6 mm, with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed. |
| 6 | Material and labour for excavation in trenches not exceding 1.5 m wide not exceding 1.5 m in depth and getting out soft/loose soil for taking down or laying of water pipe line complete all as specified and as directed. |
| 7 | Material and labour for returning filling in, including spreading, leveling watering well ramming in layer n.exc 1.5 cm thick in soft/loose soil complete all as specified and as directed. |
| 8 | Material and labour for removal of excavating material n.exc 50m & deposited where directed and n.exc 1.5m above the starting point all as specified and as directed. |
| 9 | Material and labour for attending complaints by deployinglabour for rectification of leakage ofwater pipe lines of size 100 to 150 mm Bore pipe of any description such as CI/DI/GIpipe line at any location under AGE E/M-II including necessary excavation, earth work, dewatering, including repairs with suitable flanges, rubber packing, lead wool or any other packing material complete all as specified and as directed. |
| 10 | Description all as per Item No 9.00 above but of size 50 to 80mm bore GI/DI/CI Pipe complete. |
| 11 | Description all as per Item No 9.00 above but of size 15 mm to 40mm bore GI/DI/CI Pipe complete. |
| 12 | Note for item No.9.00 to 11.00 :- i)Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 24 hours after notification, failing which Rs 500/- per day per complaint will be recovered ii) Contractor should visit the site before quoting the tender and any other misc items required for complete the job are deemed to be incl in to rate quoted by contractor (iii) How ever Pipe, valves, GI Fittingsmechenical joints required excavation if needed shall be measured and paid under relavant items of schedule. |
| 13 | Supply and fix brass ball valve of15 mm size high pressure polythene float & flynut complete all as specified and as directed. |
| 14 | Supply and fix brass ball valve of20 mm size high pressure polythene float & flynut complete all as specified and as directed. |
| 15 | Supply and fix rotational moulded polyethylene Water storage tanks ( cylindrical vertical with clsed top ) of capacity 500 Ltrs complete all as specified and as directed. |
| 16 | Supply and fix rotational moulded polyethylene Water storage tanks ( cylindrical vertical with clsed top ) of capacity 750 Ltrs complete all as specified and as directed. |
| 17 | Supply and fix rotational moulded polyethylene water storage tanks ( cylindrical vertical with clsed top ) of capacity 1000 Ltrs complete all as specified and as directed. |
| 18 | Supply and fix tube medium grade galvanised iron of size 80mm bore all as specified including all fittings as per site requirement complete all as specified and as directed.. |
| 19 | Supply and fix tube medium grade galvanised iron of size 50mm bore all as specified including all fittings as per site requirement complete all as specified and as directed.. |
| 20 | Supply and fix tube medium grade galvanised iron of size 40mm bore all as specified including all fittings as per site requirement complete all as specified and as directed. |
| 21 | Supply and fix tube medium grade galvanised iron of size 25mm bore all as specified including all fittings as per site requirement. |
| 22 | Supply and fix tube medium grade galvanised iron of size 20mm bore all as specified including all fittings as per site requirement complete all as specified and as directed. |
| 23 | Supply and fix tube medium grade galvanised iron of size 15mm bore all as specified including all fittings as per site requirement complete all as specified and as directed. |
| 24 | Material and labour for ductile Iron pipes 80 mm bore, class K-9 spigot and socket end suitable for and including push on rubber gasket joints & jointing material and pipe fittings as per site requirement including taking down old pipecomplete all as specified and as directed at site by Engr-in-Charge. |
| 25 | Material and labour for ductile Iron pipes 100 mm bore, class K-9 spigot and socket end suitable for and including push on rubber gasket joints & jointing material and pipe fittings as per site requirement including taking down old pipeall as specified and as directed. |
| 26 | Material and labour for cast Iron pipes 80 mm bore, class K-9 spigot and socket end suitable for and including push on rubber gasket joints & jointing material and pipe fittings as per site requirement including taking down old pipeall as specified and as directed. |
| 27 | Material and labour for cast Iron pipes 100 mm bore, class K-9 spigot and socket end suitable for and including push on rubber gasket joints & jointing material and pipe fittings as per site requirement including taking down old pipeall as specified and as directed. |
| 28 | Supply and fix of gun metal gate valve, cast copper alloy, screwed down, high pressure with iron wheel handle, screwed both ends for iron pipe or unions of size 50mm dia incl taking down old gate valve all as specified and as directed.. |
| 29 | Description all as item no-28.00 above but of size 40mm bore. |
| 30 | Description all as item no-28.00 above but of size 25mm bore. |
| 31 | Description all as item no-28.00 above but of size 20mm bore. |
| 32 | Description all as item no-28.00 above but of size 15mm bore. |
| 33 | Material and labour for disconnecting and taking down carefully Electric driven pumping set of capacity 7.5/10/15HP (motor and pump) from foundation, disconnecting suction and discharge water line for carrying out repair work of pump set, dismantling of pump set, cleaning, repair replacement of all unserviceable parts, reassembling complete pumping set,reinstalling , mounting and fixing on base channel on existing foundationand coupling properly to existing motor with proper balancing and alingment including recoupling of suction and discharge line, testing on full load for smooth functioning all as specified and as directed.NOTE :- (i)Rates including minor spares like gland, grease, nut bolts and major spares will be measured and paid separately and rate quoted shall be deemed to be included for fixing of new spares underthese items. (ii)Cost of transportation shall be deemed to be included in the rate quoted for these items.(iii) While taking out pump for repairs , the contractor willmakearrengement for pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbedand there is no leakage of water.(iv) The contractor shall repair and refix the pump set within three working days from the date of opening and making it functionable . |
| 34 | Description all as per item No. 29.00but of capacity 60HP all as specified and directed. |
| 35 | Supply only following spare/parts of pump set for incorporate in the Item Ser No 29.00 to 30 above |
| 36 | Pressure gauge 0-30 PSI with 15mm valve & connector |
| 37 | MS shaft for pump of capacity 60 HP |
| 38 | Impeller MS/CI suitable for pump of capacity 60 HP |
| 39 | MS geard coupling with suitable size of key for pump of capacity 60 HP |
| 40 | Gasket set suitable suitable for pump of capacity 60 HP |
| 41 | Gland bush (shaft sleeves)suitable for pump of capacity 60 HP |
| 42 | Gland Plates suitable for pump of capacity 60 HP |
| 43 | Brass Distance bush suitable for pump of capacity 60 HP |
| 44 | MS shaft suitable for pump of capacity upto 15HP |
| 45 | Impeller bush brass suitable for pump of capacity upto 15HP |
| 46 | Impeller MS/CI suitable for pump of capacity upto15HP |
| 47 | coupling(As per sample) suitable for pump of capacityupto 15HP |
| 48 | Gasket set suitable suitable for pump of capacityupto 15HP |
| 49 | Gland plates MS (As per sample) suitable for pump of capacity upto15HP |
| 50 | Gland bush / Shaft sleeve (As per sample) suitable for pump of capacity upto15HP |
| 51 | Bearing No. NU-308/309/310/313 for electric motor & pump |
| 52 | Bearing No. 6313/6310/6314 for electric motor & pump |
| 53 | Bearing No. 3309 for electric motor & pump |
| 54 | Material and labour for demolition of old foundation and construction of PCC foundation for pump set of 60 HP Capacity using concrete 1:2:4 as per requirement, foundation bolts/stud grouted in the PCC all as directed by Engr-in-Charge at site, including replacement of old rusted chassie/MS foundation as per existing size, commissioning and installation of pump set with proper allignment for smooth functioning all as specified and as directed. NOTE :- (i)Rates including disconnecting and reconnecting electric connection, suction and delevery pipe line of pump set. (ii) While taking out pump set, contractor willmakearrengement pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbedand there is no leakage of water. (iii) Contractor should visit site before quoting the rate. |
| 55 | Material and labour for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire of same guage/size to get the same output of motorincluding material such asvarnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities upto 7.5 HP all as specified and asdirected. |
| 56 | Material and labour for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire of same guage/size to get the same output of motorincluding material such asvarnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacitiesupto 15 HP all as specified and as directed. |
| 57 | Material and labour for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire of same guage/size to get the same output of motorincluding material such asvarnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 60 HP all as specified and directed. |
| 58 | Dismantling existing control & power wiring of LT starter Panel of pump motor capacity 15 HP to 60 HP & rewiring with PVC insulated copper wire existing size of control & power wiring for proper sequential working of contactors with delay timer, over load relay of water pumps, cooling tower motor, mccb etc. by making proper connections to contactors, relays, fuses, switches, voltmeter,ammter incl Repair/ replacement of damaged hinges of each compartment of panel, taking down existing bus bars and cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc testing commissioning complete all as specified and as directed.NOTE :- (i)Cost of electric cable, lugs & connectors is included in above cost.(ii)The quoted rate include the cost of painting of the panel with two coats of paints complete all as up to satisfection of Engr-in-charge. (iii) Cost of replacement of MCCB\"s, Contractor,s ,relay,s meters notincluded in the scope of work. |
| 59 | Supply and fix cast iron non return valve suitable for 80 mm bore pipe with bypass arrengementof pressure rating PN 1.6, incl ofgasket , nutbolts and washer etc & removal of Unsv NRV complete all as specified and as directed. |
| 60 | Supply and fix cast Iron sluice valve of size 80 mm dia with flanged ends drilled of class PN 1.6 with SS spindle complete with rubber gasket 6mm thick ,nuts bolts and washers etc complete including taking out old unserviceable sluice valve complete all as specified and as directed. |
| 61 | Supply and fix cast Iron sluice valve of size 100 mm dia with flanged ends drilled of class PN 1.6 with SS spindle complete with rubber gasket 6mm thick, nuts bolts and washers etc complete including taking out old unserviceable sluice valve complete all as specified and as directed. |
| 62 | Supply and fix cast iron foot valve of size 80 mm dia with flanged end including rubber gaskits , nut bolts,and washers etc complete including taking out old unserviceable foot valve complete all as specified and as directed. |
| 63 | Material and labour for construction of masonry valve chamber of 1200MM x 1200mm x 1200mm size ,100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement and suitableMS Door of 3.15mm thick MS sheetincluding MS Angle frame of MS angle size 50mmX50mmX6mm thickfixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and as directed. |
| 64 | Surface Excavation n. exc. 30 cm deep and avaraging 15cm deep and getting out any type of soil complete all as specified and directed. |
| 65 | Material and labour for providing hardcore of gauge n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 66 | Material and labour for coloured machine pressed precast concrete interlocking paver block glossy finish (Two colour combination ) any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment laid over sand cuhsion all as specified and as directed. |
| 67 | Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) complete all as specified and as directed. |
| 68 | Material and labour for cement concrete 1:4:8 type D-2 ( using 40 mm graded agg) as in sub base for stone sett paving complete all as specified and directed upto 100 mm thick finished even and fair all as specified and as directed. |
| 69 | Removal of debris (concrete, broken stone etc.) to location as directed (distance exceeding 1.5 KM but 5KM from the site ) an depositing where complete all as specified and as directed. |
| 70 | Supply and fixing for mechanicaljoint coller coupling long sleeve with rubber washer, mild steel screw bolts (machine made) with both ends screwed of dia as per flange hole and required lengtheach screwed end to be fitted with washers and hexagonal nut suitable for 80mm CI/DI/MS pipe complete all as specified and as directed. |
| 71 | Description all as item no-48.00 above but of size 100mm bore. |
| 72 | Supply and fixing of MCCB 63 Amps 36KA,4 Pole with Adjustable thermal magnetic release with Supply and fix of suitable rotary handle,spreader links etc in the control panels complete all as specified and as directed. |
| 73 | Supply and fixing of MCCB 250 Amps 36KA,4 Pole with Adjustable thermal magnetic release with Supply and fix of suitable rotary handle, spreader links etc in the control panels complete all as specified and as directed. |
| 74 | Supply and fixing of MCCB 100 Amps 36KA, 4 Pole with Adjustable thermal magnetic release with Supply and fix of suitable rotary handle,spreader links etc in the control panels complete all as specified and as directed. |
| 75 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections, one twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed. |
| 76 | Supply and fix MS ERW pipe of size 100mm bore all as specified and directed.NOTE :-Rates including minor spares like nut bolts and major fittings and jointswill be measured and paid separately complete all as specified and as directed. |
| 77 | Material and labour bracings, supports,clamps, MS Pipe, MS Plates fabricated from structural steel sections including nuts, bolts, washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated at any loaction or as directed by Engr-in-Charge at site and inclusive of one primer coat and two coats of syntetic paint complete all as specified and as directed.NOTE :- Contractor should visit site before quoting the rate. Rates including all safety equipments and T&P for execution the work. |
| 78 | Material and labour for comprehensive maintenance for diesel engine driven generating sets of capacity up to 62.5 KVA Make Cummins type S3.8G7 including attending to under mentioned jobs to ensure its satisfactorily performance as and when required or atleast ones in qtr complete all as specified and as directed. (i) Checking the condition and cleaning of Air System - oil bath / air element :-(a)Checking the Air cleaner condition(b)Checking the functioning of vacuum indicator (c)Checking the houses condition(d) Checking the condition and Clean oil cooler & cyl liner fins HA Eng(ii) Lub oil system:-(a) Checking the lub oil level / oil condition(b) Checking the condition of engine oil and replacement if required.(c) Checking the oil leakage if any.(d) Checking & cleaning centrifugal lub oil fitter(iii) Cooling system:-(a) Checking thecoolant in the system(b) Checking the coolant level and conditions(c) Checking the coolant leakages and rectification(d) Checking the belt condition and tension adjusted(e) Checking the raditor condition and cleanliness(f)Checking the Condition of all hoses and clamps (Contd.... 87) |
| 79 | (Contd from,,..56.00) (iv) Fuel system:-(a)Checking the fuel tank cleaniness / cleaning(b)Checking the condition of fuel hoses and leakages(c)Checking the drain water from water sep for K series(d)Checking the condition of baby filter and glass filter and cleaning of filter.(v) Canopy:-(a)Checking the Condition of canopy locks and hinges(b)Checking the Working ofexhaust fan (HA Engine only)(vi) AC Alternator:-(a) Checking the condition of Alternator and mountings conditons(b) Checking the condition of Couplings plate and bolt conditon(c) Checking the AVR / main alt connections(d) Checking the Proper earthing condition(e) Checking the Cond of power cable connection & terminals(f)Checking the Conditions of brushes for brush type all only |
| 80 | (Contd from.... 56.00) (vii) General:-(a) Checking of vibration pads and there condition(b) Overall condition of the engine and alternator (viii) Electrical wiring :-(a) Checking the Electrolyle level and terminal condition of Battery(b)Checking the Condition of Battery(c)Checking the Battery voltage in DC (d)Checking the Fuctioning of charging altermator(e)Checking the Function of external charge (14.1 volt DC)(f)Checking the Functioning of all gauges/meter(g) Checking the Functioning of ESU (HWT, LLOP,LFL)(h)Checking the Earthing connection of panel(j) Checking the Panel is mounted on AV mounts(k)Checking the AMF module type(l) Checking the Supply to stop solenoid(m) Checking the Auto manual mode operation (n)Checking the all wiring are connected tight(o)Checking the Overall condition of the panel |
| 81 | (Contd from.... 56.00)(ix) General Checks:-(a) Checking the fan belt and adjusting tension(b) Checking the fuel and oil filter ascerting its condition(c)Checking the air filter and its oil level cleaning the oil filter.(d)Checking of FIP performance and oil level.(e) Tightening the base bolt and nuts and mounting bolts and nuts.(f) Checking the coupling bolts and adjustement checking the self starter and dynamo.(g)Checking the battery distilled water levels and topping up to the required level.(h) Checking the loose connections if any in the panel board and tightening the same(j)Checking the anti vibration mounting adjusting the bolts.(k) Checking the radiator and radiator hose and arresting leak if any. |
| 82 | (Contd from.... 56.00)NOTE 1 :- The scope includes all scheduled & periodical maintenance of DG set as per OEM recommendations like KOEL care/Cummins or equivalent. The quoted rates are inclusive of arranging specilaised services for brake down complaints includingrepairs and overhauls. Replacement of fuel, oil filter and other consumables will be measured and paid separately under relevant items of schedules . The servicing shall be done by authorised service team of KOEL/Cummins or equivalent. The certificate in respect of preventive maintenance checks done as per prescribed format of OEM duly signed shall be submitted to department as and when required or atleast ones in quarter.NOTE 2 :- The contractor shall mention mobile number for lodging complaints if any throgh SMS. The response time for minor complaints shall be max 1 Hrs and major complaint shall be 1 days. Arrangement of listed spares as per CA is contractors responsibility and the spares not listed in the tender shall be intimated to department for procurement action. failing the above, the contractor is liable for a penality of Rs 500/- per complaint on subsequent days after laps of 1 days for minor complaints and 2 days for major complaints. |
| 83 | Description allas per Item No 56 above but 10 KVA Ratingwith Kirloskar OELmake model KG AS5 |
| 84 | Description all as per Item No 56 above but 250 KVA Ratingwith Kirloskar GreenmakeModel 284 L1 |
| 85 | Supply only follwingconsumable spares suitable up to 62.5 KVA DG Set or diesel engine driven sets all as specified and as directed. |
| 86 | Lub oil filter element |
| 87 | Fuel filter housing with benjo bolts and washers |
| 88 | Fuel filter element (primary and secondary) |
| 89 | Coolant rubber hoses with clips |
| 90 | Air circulating system hoses with clips |
| 91 | Oil circulating system hoses with clips |
| 92 | Air cleaner dry type |
| 93 | Air hose for turbo charger with clips |
| 94 | Hose for turbo charger oil dranage with addoptor |
| 95 | Supply only follwingconsumable spares suitable for 10 KVA DG all as specified and as directed. |
| 96 | Air Cleaner Outer |
| 97 | Air Cleaner Inner |
| 98 | CooalntRubber hoses with clips |
| 99 | Lub oil filter element |
| 100 | Lub oil by passFilter |
| 101 | Fuel filter primary and secondary |
| 102 | Filter element for water septator filter |
| 103 | Water separator filter unit complete with outer body and mounting bracket complete |
| 104 | Air hose for turbo charger with clips |
| 105 | Hose for turbo charger oil dranage with addoptor |
| 106 | Fan belt as per existing |
| 107 | RPM meter cable |
| 108 | Supply only followingconsumable spares suitable for 250 KVA DG Set all as specified and as directed. |
| 109 | Air Cleaner Outer |
| 110 | Air Cleaner Inner |
| 111 | Coolant Rubber hoses |
| 112 | Lub oil filter |
| 113 | Fuel filter primary and secondary |
| 114 | Air hose for turbo charger |
| 115 | Hose for turbo charger oil dranage with addoptor |
| 116 | Water separator filter |
| 117 | Coolant/ Inhibitor, corrosion resistor all as specified and as directed at site |
| 118 | Engine oil 20 W 40 grade Make Indian oil / HP / Tata BP all as specified and as directed. |
| 119 | Supply of electrolite Chemical for Ni Cd batteries all as specified and as directed.. |
| 120 | Supply of distilled water |
| 121 | Material and labour for repair to self starterupto 62.5 KVA DG 12volt DC supplyby repacement ofbearing , solonoid switch rewinding of Armature etc complete all as specified and as directed. |
| 122 | Material and labour for repair to self starter of 250 KVA DG 24 volt DC supplyby repacement of bearing , solonoid switch rewinding of Armature etc complete all as specified and as directed. |
| 123 | Material and labour for repairs to water pump assembly upto 62.5 KVA DG set by replacing water pump repair kit, bearings, water seal etc complete all as specified and as directed. |
| 124 | Material and labour for repairs to water pump assembly upto 250 KVA DG set by replacing water pump repair kit, bearings, water seal etc complete all as specified and as directed. |
| 125 | Taking down Fuel pump upto 250 KVA DG Set from the engine, to carry out necessry servicing , calibrating, incl replacement of unsv spares as required andrefixing on the engine, tesing complete all as specified and as directed. |
| 126 | Material and labour for servicing / cleaning / repairsto radiator 62.5 KVA DG SET by drainig out of water removing radiator hoses removing radiator from engine removing of sludge , flusing with antyscaling agent with high pressure pump, straitning of fins using fins straitning comb, refixing to its original position conecting of hoses refilling of coolent and testing complete all as specified and as directed. |
| 127 | Description all as per Item No 71.00 above but for 250 KVA DG SET complete. |
| 128 | Material and labour for checking of alternator exciting system of the DG Set of make KOEL/ Cummins and checking the complete system including controls and repair /modification / replacement of suitable AVR for existing system complete suitable upto62.5 to 250 KVA alternator old modle all as specified and as directed. |
| 129 | Supply and fix for self startersuitable for250 KVA DG set complete all as specified and as directed. |
| 130 | Supply and fix for self startersuitable for 62.5 KVA DG set complete all as specified and as directed. |
| 131 | Supply and fix water pressure gauge 0-30 PSI (approved make) with suitablevalve & brass connectorcomplete all as specified and as directed. |
| 132 | Supply and fix Oil pressure gauge 0-10Kg/cm sq100 mm dia (approved make) with suitableconnector all as specified and as directed. |
| 133 | Supply and fix temparaturegauge 0-150 degree centigrade as per existing model for DG set engine(approved make) with suitableconnector all as specified and as directed. |
| 134 | Material and labour for spray painting of DG Sets with two coats of anti corrosive paint over a coat of red oxide primer after removing the existing deteriorated paint by scrapping the complete body along with foundation of DG Set/Diesel driven pump sets and filling the cavities with filterand marking of SM/MES No. with black paintupto 250 KVA DG set complete all as specified and as directed. |
| 135 | Supply and fix Battery 12 volt DC 180 AH complete all as specified and as directed. |
| 136 | Material and labour for repair to Fuel injector system of DG Set 62.5/250 KVA with carry out repair of injector at auth service station and replacement of barrel plunger,cup, NRV, bushing, testing for satisefaction of Engr-in-Charge. |
| 137 | Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE cable of size 50 sqmm 3.5 core insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizesand aluminium lugs for connection complete all as specified and directed. |
| 138 | Description all as per Item no 82 but for size of 25 Sqmm 3.5 core |
| 139 | Description all as per Item no 82 but for size of 16 Sqmm 4 core |
| 140 | Material and labour for replacement of battery charging unit for DG set 62.5 to 250 KVAcomplete with necessary connection all as specified and as directed. |
| 141 | Material and labour for cleaning of oil sump, with replacment of oil pump strainer, drain plug, packing complete of DG Set upto capacity 62.5KVA to 250 KVA all as specified and as directed. |
| 142 | Material and labour for taking down unserviceable Automatic voltageRegulator (AVR) from panel board, supply, installation, commissioning and testing of new AVR suitabe for DG set upto 250 KVA , 415 Volts complete all as specified and as directed. |
| 143 | Material and labour for taking down unserviceable Power contactor of350 A ,415 volt 4 pole from panel board, supply, installation and testing of new Power contactor of same capacity forDG setcomplete all as specified and as directed. |
| 144 | Material and labour for taking down unserviceable Digitel Controller Unit from panel board and supply, installation, commissioning and testing of newController Unit suitabe for DG set 62.5 KVA 415 Volts incl showingdesplay of all parameters of DG Set complete all as directed. |
| 145 | Material and labour for taking down unserviceable Digitel Controller Unit from panel board and supply, installation, commissioning and testing of newController Unit suitabe for DG set 250 KVA , 415 Volts incl showingdesplay of all parameters of DG Set complete all as directed. |
| 146 | Material and labour for Cleaning of RCC underground/semi under ground water supply sump, static water tank of capacity 30000 gallons to 50000G gallons by dewatring and taking out all scales, dirt, mud. algae etc from inside the tank and from mouth of circulating pipes includinand taking out sludge with help of disel driven sludge pump of suitable capacity including washing of tank wall with bleaching powder solution and then with water and draining out sludge, water completely all as specified and as directed.NOTE :-(i) Cleaning should be done by scraper and removing dirt with brush and washing with bleaching powder all as directed by Engr-in-Charge.(ii)The inlet and outlet / over flow pipe of sump should be cleaned properly and care should be taken to prevent entry of sludge into pipe line by blocking mouth of pipe.Any blockage of the inlet / outlet / overflow pipe line shall be cleaned by contractor at no extra cost.(iii) Date of cleaning \"CLEANED ON ___________ NEXT due DATE ______________\" should be painted with black and white paint as per Existing size.(iv) Tank / Sump capaciting \"CAPACITY ________ GLNS\" should be painted on tank as per existing size. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail