| 1 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. orfor shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth in any type of soil and getting out,complete all as specified and as directed. |
| 2 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed. |
| 3 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified. |
| 4 | Mild steel work in tubular trusses including pecial shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 or Fe-410-0 or Fe-310-0, complete all as specified & directed. |
| 5 | Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified. |
| 6 | Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified. |
| 7 | 15mm thick plastering in cement mortar1:4 on brick concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified. |
| 8 | 10mm thick plastering in cement mortar1:4 on brick concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified. |
| 9 | Preparation of new plastered surfaces of walland applying three coats of white wash, complete all as specified |
| 10 | Preparation of new plastered or concrete surfaces of walland applying two coats of cement base paint, complete all as specified. |
| 11 | 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.. |
| 12 | Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 ltrs, fixed in repair,complete all as specified. |
| 13 | GI water tubing, medium grade, 15mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, completeall as specified. |
| 14 | Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 20mm, complete all as specified. |
| 15 | Gun-metal, globe or gate valves of 25mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified. |
| 16 | Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed. |
| 17 | Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed. |
| 18 | Hard core of gauge exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified. |
| 19 | Machine cut kota stone slab flooring, 20-22 mm thick , laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 15mm screed layer in cement mortar 1:6, rubbing, grinding and polishing to achieve mirror finish, complete all as specified. |
| 20 | Plain cement concrete 1:4:8 (nominal mix), type D-2, using 40mm graded crushed stone aggregate as infoundations, filling and mass concrete, complete all as specified & directed. |
| 21 | RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., complete all as specified & directed. |
| 22 | RCC M-25, design mix,using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified. |
| 23 | Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed. |
| 24 | Use & waste of form work to sides of pillars, posts, structs, columns etc. for rough finished surfaces of concrete, complete all as specified & directed. |
| 25 | Mild steel TMT bars 6mm to 8mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified& directed. |
| 26 | Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified& directed. |
| 27 | Bib taps, 15mm bore, cast copper alloy,with crutch or butter fly handle, screwed down, screwed for iron pipe, or brass ferrule, fixed in repair, complete all as specifed. |
| 28 | 75mm thick plain cement concrete 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and fair, complete all as specified. |
| 29 | Plain cement concrete 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in surface channel and drains, complete all as specified. |
| 30 | Plain cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 31 | Forming embankments of soils including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc 1.5m high from base, complete all as specified. |
| 32 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified & directed. |
| 33 | 75mm thick plain cement concrete 1:4:8, nominal mix, type D2, using 40mm graded crushed stone aggregate as in flooring/paving, surface finished even and smooth without using extra cement, complete all as specified. |
| 34 | Machine pressed concrete interlocking paver block glossy finish, any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigmentcomplete all as specified & directed |
| 35 | Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified. |
| 36 | Plain cement concrete 1:2:8 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified & directed. |
| 37 | Plain cement concrete 1:3:6, (nominal mix), type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed. |
| 38 | Plain cement concrete 1:2:4, nominal mix, type B-1, using 12.5mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 39 | Supply only integral water proofing compound, complete all as specifed. |
| 40 | Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed. |
| 41 | Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) typeD-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed. |
| 42 | Reinforced concrete pipes, class NP2, laid & jointed complete with collars, bore of pipe 150mm, complete all as specified & directed. |
| 43 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified. |
| 44 | Construction of soakage well of size 1.8m dia x 4.5m depth (Internal dimensions), brick construction, complete all as specified and as shown on drawings. |
| 45 | Construction of Septic tank 50 users, brick construction,complete all as specified and as shown on drawings. |
| 46 | Plain cement concrete 1:3:6, (nominal mix), type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed. |
| 47 | Plain cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 48 | M&L for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade stranded copper conductor cable single core 1.5 Sqmm for one light / fan point/bell point controlled by one way switch, and wire to be drawn in and including concealed conduit of dia not less tham 25mm and half portion surface wiring through ceiling/stress complete with all accessories including MS sheet metal 1.2 mm thick switch board of suitable sizebe fixed flush wall , with 3 mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed by EIC and providing earth continuity wire using PVC insulated, un sheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm. |
| 49 | All as per item No 48 One light Pointcontrolled by one,one wayswitch. |
| 50 | All as per item No 48 One ceiling fan controlled by one way switch. |
| 51 | All as per item No 48 One exhaust fan controlled by one way switch. |
| 52 | All as per item No 48 above but 3 Pin 5 Amp modular Socket on the same board, complete all as specified. |
| 53 | All as per item No 48 above but 3 Pin 5 Amp modular Socket on independent board complete all as specified and directed. |
| 54 | All as per item No 48 above but M & L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and includingPVC conduit size of not less than 25mm concecled in wall / surfaceincluding sutiable new annealed sunken boxes,modular frame and cover plate for fixing of modular switch, socket and regulator along with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and for one 5 pin modular socket outlet two in one 16/6 amps on an independent board including making good, disturb surface as it is complete all as specified and directed. |
| 55 | Switch Piano flush type single pole 5 Amps One way,all as specified and directed . |
| 56 | Socket, flush type, single pole, one way, 5Amps,complete all as specified and as directed. |
| 57 | Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15 Amp flush type, complete all as specified and as directed. |
| 58 | Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically,complete all as specified and as directed |
| 59 | Ceiling rose, surface bakelite 65x 50mm two to three terminals, complete all as specified and directed. |
| 60 | Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVCinsulated 2 core flexible cable with flexible PVC pipefrom ceiling rose to fittings complete all as specified and as directed. |
| 61 | Supply & fixing in replacement of 35 Watt LED security light fitting with ASTRA NEO street lights are made up of pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection and with 0.6 mtr long 20/25 mm (as per manufacturer standard)dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specifiedand directed. |
| 62 | Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar,double door typeincluding cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed.(Note: MCBs will be measurd separately). |
| 63 | MCB, single pole and neutral (SPN), 240 volts,40 amps breaking capacity 10KA, ‘B’ Series. etc , complete all as specified and directed. |
| 64 | MCB, single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘B’ seriescomplete all as specified and directed. |
| 65 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6type C-1 chamber with cover and RCC1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as directed by Engr-in-Charge. |
| 66 | Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep,BLDC,including making connection with and including suitable flexible copper wire, complete all as specified and as directed. |
| 67 | Sub main wiring concealed with tworuns of 4 Sqmm(2x4 sqmm) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire, complete all as specified and directed.Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 68 | Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed |
| 69 | Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 1100 volts grade cross sectional area 16 sq mm, 2 core including taking down of U/S Cable complete all as specified and directed. |
| 70 | Supplyand ererction in vertical position Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 finial taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome primer and two coats of black bitumenous paint internally & portion embedded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation steel clamps, MS Cross arms andbracing of angle iron etc., shall be measured and paid for separetelyunder relevant items. |
| 71 | Supply and fixing LED 70 watt, IP LED Street security light luminaries on existing decorative poles of suitable bracket dia comprising of die cast aluminium housing with whether proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 lumen/watt, lumen maintenance > 70% at 50000 hrs, colour temp 5000-6500k, CRI>70, THD<15%, PF>0.95 and LM 80 test compliance. The driver must be integrated APFC with short circuit protection reverse polarity protection against 4 KV high surges and comly with IEC 61000-3, IEC-61547. The luminaries must have secondary optics with perfectly matched lens for better light control including making electrical connection specified and as directed. |
| 72 | Street light Bracket complete made of GI tubing 40mm bore, light grade of suitable size, 1.5m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction |
| 73 | Supply & fix sintex box of size 280 X 170 X 130 mmCat No GS-JB-2817 Hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor 1Phase and1neutral fixed on polewith the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light. |
| 74 | Supply, install, testing and commissioning in replacement offactory made \" outdoor type \"CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete :- 400 Amps capacity copper bus bar strip - 4 Nos. of suitable length. INCOMING(i) MCCB FP 63 Amps, capacity 16kA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No.(ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) copper bus bar capacity 150 Amps for Phase-R-Y-B- N - 4 Nos.(vi) Timer switch with contactor - 1 No ( for street light)OUTGOING:(i) MCB SPN 40 Amps, capacity 10 kA,- 05 Nos. (spare 1 Nos)(ii) MCB SPN 32 Amps repturing capacity 10 KA - 01 No (Street light) |
| 75 | S & F for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Notes:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge |
| 76 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure , complete all as specified and as directed. |
| 77 | Supply and lay G.I pipe Light grade with all fittings required for protection of under ground cable including cutting of road surface wherever required and making good to match with existing surface of size 50 mm dia all as specified and directed |
| 78 | All as per item No.77 but of size 40mmm bore |
| 79 | Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed. |
| 80 | Sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and as directed. Note:- For payment purpose punned thickness shall be measured. |
| 81 | GI water tubing, medium grade, 50mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, completeall as specified. |
| 82 | GI water tubing, medium grade, 40mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, completeall as specified. |
| 83 | GI water tubing, medium grade, 25mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, completeall as specified. |
| 84 | Gun-metal, globe or gate valves of 50mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified. |
| 85 | Gun-metal, globe or gate valves of 40mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified. |
| 86 | Gun-metal, globe or gate valves of 25mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified. |
| 87 | M&L for construction of brick masonary valve pits of size 900x900x600 mm(internal dimension) with brick work in cement mortar (1:4), 100 mm thick lean concrete i.e. PCC 1:4:8 ( 40 mm graded aggregate ), PCC bedding with PCC 1:2:4 type B-1 using 20 mm graded aggregate, 15 mm thick plastering in cement mortar 1:4 internally & externally complete incl 15 cm below GL externally ( on all sides ) including necessary excavation and earth work, concrete work ,MS sheet cover 3.15 mm thick with locking arrangement, hinges and handle rendering work, painting to all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer incl. preparation of surfaces completeall as specified and as shown on drawings. |
| 88 | Cutting of existing any type of GI/CI/DI water pipe/ water tank connecting to the new water line including all necessary items for 80 mm pipe and making suitable jointing for 80 mm dia pipe including welding, bending and necessary fittings complete all as specified and as directed. |