| 1 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed |
| 2 | M&L brick work with sub class `B\" Brick on straight on curved on plan to any radious in full brick work in cm 1:6 complete all as specified and directed. |
| 3 | Allas per Item No- 02 here in above but except bricks. |
| 4 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 befinished even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for preparation of new plasteredsurfaces of wall and applying three coat of white wash complete all as specified and as directed by Engr- in- Charge. |
| 7 | M&L for preparing of old decorated surfaces and applying onecoat of cement based paint on walls complete all as specified and as directed. |
| 8 | S&F for ornamental and intricate design Framed work such as grills,gratings, etc. with ends of barsshouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and hung as gates including pintel hinge stops hand made sliding bolt etc complete all as specified. |
| 9 | Dismantling floor, hearth or wall tiling, chequered tile and interlocking including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 10 | Demolition of cement concrete (unreinforced) in ground floors and roof and paving /paver block not exceeding 15 cm thickness (below or above ground level) .complete all as specified and directed. |
| 11 | M&L for 75 mm PCC (1:4:8 ) type D2 using 40 mm graded aggregate as in sub base floor . |
| 12 | M&L for 80 mm thk PCC M-35 machine pressed rubber moulded coloured interlocking pavor block any shape and size confirming to IS 15658-2006 using white cement with labour finish complete all as specified and directed. |
| 13 | M&L for sand cushion for paver block completed all as specified and detected. |
| 14 | S&F in repairs galvanised 2 strand , steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolt, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured),complete all as specified and as directed by the Engr-in-charge. |
| 15 | Dismantling of stone slab and tiles laid on dry of anydescription or thickness in floors,aprons etc complete all as specified. |
| 16 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. |
| 17 | Dismantlingposts or struts (wood,steel or RCC) any section including taking out embedded from concrete,brick work,masonary etc portion and making good disturbed ground complete all as specified and directed. |
| 18 | S & FTMT steel bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia complete all as specified. |
| 19 | S & FTMT steel bars 6 to 8mm dia , cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia complete all as specified. |
| 20 | Dismantling wrought iron or Mild Steel work of any description and any position not other wise provided for complete all as specified and as directed by the Engr-in-charge. |
| 21 | Dismantling of fencing wire any type, complete all as specified and as directed by the Engr-in-charge. |
| 22 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 23 | Supply only steel wire chain link wire fencing opening 50X50mm , secured withMS flat, straing bolt complete all as specified and directed. |
| 24 | Fixing only chain link fencing including line wires, and mesh size type to any type of standard, rail straining bolts etc including binding, provission of binding wire complete all as specified and directed. |
| 25 | Excavating in soft/ loose soil post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 26 | M&L PCC (1:2:4) type B2 using (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed . |
| 27 | S&F mild steel screw bolt (machine made) with hexagonal at one ends and screwed the other ends, each screwed ends to be fitted with washer and one hexagonal nuts, size of bolt 10mm dia and length of bolt exc 5cm but nexc 10cm long. (from under side of head to the end in 75mm) |
| 28 | M & L for two coat of synthetic enamel paint over one coat of red oxide primer on new steel surface incl preparation exc. 10 cm width or girth incl complete all as directed. |
| 29 | M&L for Precast concrete U drain of size 450x600mm with cover of M35 Grade and 8 mm Bar @ 100 mm c/c complete all as specified and directed by Engineer-in-Charge. Make Himalaya Spun pipe or equivalent. |
| 30 | M&L for Precast concrete U drain of size 300x400mm with cover of M35 Grade and 8 mm Bar @ 100 mm c/c complete all as specified and directed by Engineer-in-Charge. Make Himalaya Spun pipe or equivalent. |
| 31 | M&L for non skid coloured heavy duty tiles 12 mm thick of sqaure in size 400mmx400mm, laid in floors etc complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying further floor finishes all as directed by Engr-in-Charge. |