| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.. complete all as specified and directed. |
| 2 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 3 | Disconnect and taking down existing exhaust fan of size 250mm sweep or 300 mm sweep with louverand hand over to MES store yard for safe custody. |
| 4 | Disconnect and taking down carefully electrical geysers of capacity upto 50 ltrs by unscrewing nuts and bolts from clamps, disconnecting electrical connections and PVC cold/hot water connections and keeping serviceable geysers in safe custody for refixing complete all as specified and directed. Note: The cost of transportation and depositing the unsv geysers to the MES stores is deemed to be included in the unit quoted rates. |
| 5 | Fixing only for electric water heater , storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 6 | Labour for taking out the existing energy meters, cleaning and deposit to BSO in good condintionas directed by Engr-in-Charge and stickering the name of the corresponding Qtr No complete all as directed. |
| 7 | Labour only for refixing the serviceableexisting energy meters, cleaning and collected from BSO in good condintion as fixing the stickering Qtr No complete all as directed. |
| 8 | M&L for concealed point wiring with 1.5 Sq mm,FRLS, PVC single core sheaded cable, copper conductor cable of 1100 Volt grade, multi stranded drawn through rigid non metalic medium grade PVC conduit concealed in wall with suitable modular metal boxes flush to wall , controlled by one switch with and includingcontinuous 1.5 Sqmm PVC insulated single core copper conductor cable as earth continuity conductor connected to commonearth dolly etc. complete all as specified and directed. Note :(i)The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.(ii) The cost of cutting chases is deemed to be included in the unit quoted rate. |
| 9 | a) One light/fan/call bell point controlled by one switch |
| 10 | b) One 5 amps 3 Pin socket outlet on independent board |
| 11 | c) One light point controlled by two, two way switches |
| 12 | All as per Item No-8 above but with FRLS PVC insulatedcopper conductor cable of size 2.5 Sqmm 3 pin socket outlet, for independent complete all as specified and directed. |
| 13 | S&F Modular type socket out let 2/3 pin, 6/16 Amps, 2 module all as specified and as directed. |
| 14 | S&F Modular type Socket outlet 6 Amps 2/3 Pin, 2 module complete all as specified and directed. |
| 15 | S&F Modular type switch single pole 16 Amps one way, 1 module all as specified and as directed |
| 16 | S&F Modular type switch single pole 6 Amps, 1 module, one way all as specified and as directed. |
| 17 | S&F Switch modular type switch single pole, 6 Amps,1 module, Two way complete all as specified and directed. |
| 18 | S&F Modular type Bell switch single pole 6 Amps one way, one module all as specified and as directed. |
| 19 | S&F Buzzer, Ding Dong AC, 230 Volts, single pole complete all as specified and directed. |
| 20 | S&F ceiling rose surface mount PVC/Polycarbonate, isolated body with face bakelite two/three terminals complete all as specified and directed. |
| 21 | S&F modular white cover plate with frame, 1 module complete all as specified and directed. |
| 22 | S&F modular white cover plate with frame, 3 module complete all as specified and directed. |
| 23 | S&F modular white cover plate with frame, 4 module complete all as specified and directed. |
| 24 | S&F in repair LEDstreet light /security light luminaries fitting 1X30 watt LED with min 120 lumens/watt output including GI bracket made out of GI pipe light grade 25 mm dia 1.20 m long bent to shape with suitable size mild steel clamps of size 50 X 6mm with nut, bolt, & washers as required at site for fixing of street light on LT poles / wall including making connection with PVC insulated 3 single core of 1.5 sqmm size multistranded copper conductor cable complete all as specified and directed. |
| 25 | Supply and fixing LED lights fitting 1 x 20W, 220V, AC , (4 ft.) High performanceelectronic driver , operating temperature 10 C to 35 °C operating voltage range 140 V -270 V , Average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 Im/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make Havells cat part No LUMILINEPLUSPROBS20WLED865SPCSSIND OUG G |
| 26 | Supply and fixing LED lights fitting 1x 10W, 220V, AC , (2 ft.) High performance electronic driver , operating temperature 10° C to 35 °C operating voltage range 140 V -270 V , Average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 lm/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make Havells cat part No LUMILINEPLUSPROBS10WLED865SPCWHIND or equivelent |
| 27 | S&F decorative wall mountingBrushed nickel finishing fixture luminaire of double arm withOpal glass diffuserwith two LED lamp 9W, B22 with all accessories internally prewired and including connecting up complete all as specified and as directed.Note: The cost of making good and matching to the existing surface is deemed to be included in the unit quoted rates. Havells cat part No gobleto wl 1ls e27 gldor equivlent. Make Havells cat part No floretine wl 2ls b22 ss or equivlent |
| 28 | S&F decorative bulk head edge lit LED luminaire 10Wwith min 120 lumens/watt output IP >= 65,IK>=07, Class I Environment friendly, energy saving, surface mounted, decorative bulk head edge lit LED luminaire 10Wwith min 120 lumens/watt output made of pressure die cast aluminium housing with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.Make Havells cat part No floretine WL 2LS B22 SS or equivalent. |
| 29 | S&F TV coaxial socket,1 modulecomplete all as specified and directed. |
| 30 | M & L for concealed sub-main wiring alongwith earth wire of size (2 x 6.00) sq. mm + (1 x 6.00) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed.Make of cable : Havells/Polycab/Finolex, Make of conduit-Precision/Press-fit/finolex.NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately.2) Cutting chases & making good, includingnecessaryPutty work of the disturbed surfaces is deemed to be included in the unit quoted rates. |
| 31 | S & F SPN DB, 8 Way,Metal double door type 240 volts fitted with 200 Amps rated busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. |
| 32 | Supply and fixing amp rating 240V, 10KA \"C\" Curve Miniature Circuit Breaker (MCB) ofSP 6 to 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and dircted. |
| 33 | Supply and fixing amp rating 240V, 10KA \"C\" Curve Miniature Circuit Breaker (MCB) ofSPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and dircted. |
| 34 | Supply and Fixingexhaust fanPVC 250 mm sweep and connecting up including cleaning andpainting with white enamel paint one coat andprovision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 35 | Supply and Fixingexhaust fanmetal 300 mm sweep and connecting up including cleaning andpainting with white enamel paint one coat andprovision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 36 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. |