| 1 | Schedule-A |
| 2 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 4 core complete all as specified and as directed. |
| 3 | All as per Srl itemNo.1 above butof size 95 Sqmm, 3.5 core -ditto- |
| 4 | All as per Srl itemNo.1 above butof size 185 Sqmm, 3.5 core -ditto- |
| 5 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 6 | Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. |
| 7 | Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. |
| 8 | Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed. |
| 9 | M&L Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 Old size bricks for the protection for underground cable. |
| 10 | M & L for cutting of existing bitumen road/ hard standing for laying of cable/protection pipe after that makeover through PCC 1 : 3: 6 type C1(using 20 mm graded crushed stone aggregate)complete all as specified and directed. |
| 11 | Supply and fixingin replacement of GI tubing, light grade, 40mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and directed. |
| 12 | M&L for galvanised iron steel tubes, ISI marked light grade of50mmfor cable protection under road or drains, complete all as specifiedand directed |
| 13 | All as per Srl item No.11 above butsize 80mm bore complete all as specifiedand directed |
| 14 | Labour and required tools for carrying out horizontal boring below roads/PCC hard standing/Drain suitable up to 80mm dia GI pipe all as specified as directed for inserting GI pipe with a depth upto 1.5 m & length of road up to 12 m complete all as specified and as directed. |
| 15 | Supply and fixingLT panel pillar box cubical type ofcomprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 240 Amp capacity, 4 stripmounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame andlegs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable,foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following(Note: Drawing for LT PANEL shall be got approved from Accepting Officer GE before fabrication):- |
| 16 | Incoming(i) MCCB 160 Amp Adjustable36 KA, FP, single frame - 01 No.Outgoing(i) MCCB 100 Amp Adjustable16 KA, FP, single frame -1 No.(ii) MCCB 63Amp Adjustable 16 KA, FP, single frame - 03 Nos (iii) LED indicating Lamps ( R, Y, B) one set-01(iv) Volt meter 0-500 V digital with selector switch-01Nos(v) Ampere meter 0- 200 amp with selector switch-01Nos |
| 17 | Supply and fixingLT panel pillar box cubical type ofcomprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 525 Amp capacity, 4 stripmounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame andlegs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable,foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following(Note: Drawing for LT PANEL shall be got approved from Accepting Officer GE before fabrication):- |
| 18 | Incoming(i) MCCB 350 Amp Adjustable36 KA, FP, single frame - 01 No.Outgoing(i) MCCB 200 Amp Adjustable25 KA, FP, single frame -1 No.(ii) MCCB 100Amp Adjustable25 KA, FP, single frame - 02 Nos (iii) MCCB 63 Amp Adjustable25 KA, FP, single frame - 02 Nos(iv) LED indicating Lamps ( R, Y, B) one set-01(v) Onload Change Over switch 300 A, FP-01 Nos(vi) Volt meter 0-500 V digital with selector switch-01Nos(vii) Ampere meter 0- 500 amp with selector switch-01Nos |
| 19 | S&F in replacement street light pole box with transparent lid IP 65 weather proof of suitable size fixed to pole / wall with suitable FI clamp 20mmX3mm nuts,bolts and washers incl provision of 01 no miniature circuit breker (MMCBs) SPN \"C\" SERIES, 240 Volts 10KA 06 Amps and incl suitable for 1nos 50/16 sqmm x 3.5/4 core XLPE outgoing cable complete all as specified and directed. |
| 20 | M&L for connecting the street light point from the pole box by using two runs of single core 1.5 sqmm.PVC insulated sheathed FR Copper conductor cable including PVC conduit/ flexible pipe of suitable dia along with one run of 1.5 sqmm FR copper cable for earth continuity conductor as earth lead for street light, complete all as specified and directed. |
| 21 | M&L for earthing to panel / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected toPanel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.Note : GI strip and GI light grade protection pipe40 mm bore up to 7.5 metre is included in unit rate and beyond that the same will be measured separately and complition after earthing testing below 5 ohm. |
| 22 | M&L for cable route indicator with a welded/riveted disc 10cm dia and engraved with cable with cable route markar made out of angle iron 40X40X40mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggtegate at approx distance 30 mtr including necessary earth work complete all as specied and directed |
| 23 | S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 24 | S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes and making good to surfaces in wall/floor for passing in or through conduit. |
| 25 | Material and labour for sub-main wiring with2 runs of10 sqmm FRLS PVC insulated, multi-stranded, copper cable, 1100 V grade, along with one run of 10.0 sqmm copper cable for earth continuity wire connected to common earth dolly (Colour code to be followed) drawn through concealed 20 mm dia, medium grade,Steel conduit, including accessories complete all as specified and directed .Make of Cable : Polycab/ L&T/ Havells |
| 26 | All as per above item no 22 but three runs of 2.5 sqmm complete all as specified and as directed |
| 27 | Supply and fix in factory made epoxy polyster powder coated distribution board SP&N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). |
| 28 | S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, \"C\" series type complete all as specified and as directed. |
| 29 | S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make : Make: Legrand /Siemens/Schneider. |
| 30 | S&F Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed. |
| 31 | Supply and fixnig air cooled inverter type split unit air conditioner electric driven, single phase with cordless remote control unit and with built in ionisser and plasma filter for better indoor air quality of capacity 2 TR 5 star rated and EER 3.2 as specified and directed. |
| 32 | S&F nylon braided PVC pipe of size 20mm dia outer suitabel for split AC drain including fixing accessories such as claps scews rawl plugs etc complete all as specified and directed |
| 33 | S&F pre-fabricated AC stand suitable for wall mounting or floor mounting made with mild painted with synthetic enamel paint with anti vibration rubber pads including grouting in wall applicable for wall mounting type complete all as specified |
| 34 | M&L for suction and discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 2 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre. |
| 35 | All as per item No 31 above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5mm thickness |
| 36 | M&L for insulating the suction and discharge copper tubing from in door unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed |
| 37 | Supply, installation, testing and commissioning voltage stabilizer for automatic operation single phase naturally air cooled indoor type and wall mounting type and designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 vols with accuracy + 2.5% including timedelay relay and LCD display of5 KVA rated capacity complete. |
| 38 | Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size , platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- |
| 39 | INCOMING(a)MCCB, four pole, 320 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting-01 No.(b) 600 Amps rated alluminiumbus bar suitable for 4 pole system- 01 Set.(c)Phase indicating lamp RYB LED type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired. (e) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired.(f) Changeover switch 415 Volts,315 Amps 4 pole- 01 NoOUT GOING(a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos (b) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-05 Nos(c) MCCB four pole125 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-04 Nos (d) Trivectormeter three phase of rating 0 to 60 Amps 415 Volts -03 Nos (e)Space for mounting electric meter -03 Nos(f) Spare box suitable for 250 Amps 25 KA MCCB - 01 No |
| 40 | Supply , Laying , testing and commissioning XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core complete all as specified & directed by Engineer - In - Charge. |
| 41 | Supply and fixing sheet metal enclosure double metal door factory made TPN 415 volt 4 way suitable for fixing MCB as outgoing and MCCB TP 63to 125 Amps 16 KA mechanical type as main incoming duly painted all as specifiedincluding necessary electrical connection and flush in wall with necessary pcc works and make good the distrubed surface with existing surface complete all as specified and directed. |
| 42 | S&F in replacement of MCCB 3 pole mechanical type, capacity 125 Amps with breaking capacity 16 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand |
| 43 | S&F in MCB SP 40 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make: Legrand /Siemens/Schneider. |
| 44 | Supply and fix in replacement of factory made epoxy polyster powder coated distribution board double doorSP&N 8 way 240V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. Make: Legrand /Siemens/Schneider. |
| 45 | Ditto-above item No 40but4 way double doorwith 200 ampsrated bus bar240V complete all as specifed and as directed. |
| 46 | Supply and fixing SPN 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) oftwo pole complete with connection testing and commissioning. |
| 47 | S&F Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed. |
| 48 | Material & Labour for concealed point wiring with single core FRLSH PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge.Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. |
| 49 | For one light point controlled by one single pole switch & socket. |
| 50 | For one fan/exhaust/wall mounted point controlled by one single pole switch. |
| 51 | For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm |
| 52 | For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size |
| 53 | Ditto- above butsocket outlet indepen dent but below the switch board of light points in the same vertical plane, with cables.1.5 sq. mm size |
| 54 | One bell/buzzer point controlled by one bell push switch |
| 55 | One light point controlled by two-way switches with cables 1.5 Sqmm size |
| 56 | Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 57 | Supply and Fixingmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. |
| 58 | Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 59 | Supply and Fixingmodular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. |
| 60 | Supply and fixing in replacement of Modular Bell push 6 amps, 1 module as specified. |
| 61 | Supply and fixing in replacement of switch 2 way 6 Amps, 1 module |
| 62 | S&FGI Modular gang sunk-in pressedterminal boxes of required size not less than 1.2 mm thick factory made for following module complete all specified and directed.Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate. |
| 63 | Metal flush box 3 module |
| 64 | Metal flush box6 module |
| 65 | Metal flush box8 module |
| 66 | Metal flush box12 module |
| 67 | S&F white cover plate with frame of following module complete all specified and directed. |
| 68 | White cover plate with frame 3 module |
| 69 | White cover plate with frame 4 module |
| 70 | White cover plate with frame 8 module |
| 71 | White cover plate with frame 12 module |
| 72 | Supply and fixing of ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge.Note : Ceiling rose will be issue by the department. |
| 73 | Taking down and refixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable after false ceiling work completeincluding connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 74 | M & L for concealedpower point wiring for 5 pin, 15 Amp socket outleton independent boardwith 2.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping to be done wherever wiring to be run on ceilings and concrete surfaces including one run of 2.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly,including sunksheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface ,including laminated hylum sheet cover, ISI marked of Make\" Hylem\" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring Make of Cable : Polycab/ L&T/ Havells |
| 75 | S&F twin socket modular type heavyduty out let 6 pin 6/16 Amps 2 module, |
| 76 | M&Lswitch Modular type 16 Amps , single pole one way 240 volts one module as specified. |
| 77 | S&F for metal flush box for fixing of switches for 3 module |
| 78 | Supply & fix Modular White cover plate with frame for 3 module |
| 79 | S&F Sheet metal enclosureDouble doorSPN 240 Volts 4 way DB with 200 Amps rated busbar complete all as specified and directed. |
| 80 | M&L for chemical earthing complete with copper earth plate 60cmx60cmx3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to copper earth strip 20X3mmby means of bolts nuts check-nuts and washers of galvanized ironor steel as shown in electrical plate No 3 of MES schedule Part-I connecting to earthing test point and testing on completion with including 40 mm bore lightgrade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed. |
| 81 | M&L for copper strip 32 x 6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge. |
| 82 | M&L for copper strip 20 x 3mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge. |
| 83 | M&L for demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 84 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of stay assembly etc including necessary form work , all as specified and directed. |
| 85 | Supply only Candle PVC tape fire retardant insulated electrical in multi colour size 6 mtr x1.7cmx0.125mm thick |
| 86 | S&Fswitch Modular type 16 Amps , single pole one way 240 volts one module as specified. |
| 87 | M&L for metal flush box for fixing of switches for 3 module |
| 88 | Supply & fix Modular White cover plate with frame for 3 module complete all as specified and directed. |
| 89 | S&F Sheet metal enclosureDouble doorSPN 240 Volts 12 way DB with 200 Amps rated busbar complete all as specified and directed. |
| 90 | Ditto-above but three run of 2.5 sq mm complete all as specifed and as directed. |
| 91 | S&F MCB SPN 63 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make: Legrand /Siemens/Schneider. |
| 92 | Supply and fix float cum boost battery charger (Thyristor Controlled) of capacity 24 V(2Vx 12 Batteries) , 100 AH, single phase for 3 feeder BATTERY CHARGER and D.C distribution board in common cubicle .The charger is schedule for 230V+/-10%, AC input and the output is suitable to charge of 24V DC 100Ah batteries and also supply load, The output voltage remains constant within +/-2% for AC input voltage variation 230V +/- 10% and load variation 0-100%, current ratings 100 A, over charging, overvoltage, undervoltage, over load and current limit protection complete all as specified and directed.Note:- (i) Rate of Float cum boost Battery charger are included with battery.(ii) Battery 2V,100AH warranty 36 Months for float cum battery charger complete all as specified and directed.(iii) Cable required 2.5 sqmmx3 core for connection, battery charger to feeder panel area included in this item. |
| 93 | S&F 2.5 Sqmmx 2 Core PVC Cable for Battery charger complete all as specified and directed. |
| 94 | Supply and fix UPS 30 KVA for40 minute minimum back up three phase AC input 3 phase, 4 wire voltage range (VAC) 310 to 480 V, 55 HZ, phase out put 3 phase, 4 wire, battery voltage(VDC) 384 - 600 VDC(as per manufacturer design), battery charging current 15 A, operating temperature (Celsius) 0 to 45 degree C,industrial online system with True inbuilt isolation transformer with out put power of battery 28080 VAH and out put voltage415 V ± 1% of capacity 30 KVAonline UPS with isolation transformer (HPH Series) all as specified and directed by Engr-in-charge. Note:- (1) Following Items from 1.1 to 1.5 are assemble at site for industrial purpose and the rate of UPS & their items are include in this items.1.1 S&FBattery 12V 65 AH, warranty 36 months for invertor/UPS complete all as specified and directed. [MAKE:-EXIDE/Amron/Tata Industries maintenance free battery 12V 65 Ah battery )- 36 Nos 1.2 S&F Battery Rack angle iron with painted for suitable for 36 Nos 12V 65 AH batteries complete all as specified and directed. - 01 Nos 1.3 S&F interlink connector for 30 KVA UPS- 432 VDC all as specified and directed. -01 Nos1.4 S&F DC breaker for 30 KVA industrial online UPSall as specified and directed.- 01 Nos 1.5 S&Fappropriate size of copper conductor recommended by manufacturer for 30 KVA UPS out put and input supply for connection of batteries complete all as specified and directed. |
| 95 | Supply and fixing of voltage stabilizer for automatic operation, single-phase, naturally air-cooled, indoor type, suitable for input voltage variation from 170V to 250V, delivering stabilized output voltage of 230V ±2.5%, of capacity 5 KVA, complete all as specified and as directed |
| 96 | Note:- The amount of Rs 23600 against Schedule of Crediton Srl Page 146 shall be deducted from the total amount quoted against Sch \"A\" |