| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2 | 1 or 2 Module (75mmX75mm) |
| 3 | 3 Module (100mmX75mm) |
| 4 | 6 Moudle (200mmX75mm) |
| 5 | 8 Module (125mmX125mm) |
| 6 | 12 Module (200mmX150mm) |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 8 | Group A |
| 9 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 10 | Supplying and fixing following modular switch/ socket on the existingmodular plate and switch box including connections but excluding modular plate etc. as required |
| 11 | 5/6 A switch |
| 12 | 2 way 5/6 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 15/16 A switch |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Bell push |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections, painting etc. as required. |
| 19 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 20 | Supplying and fixing brass batten/ angle holder/PVC holder including connection etc. as required. |
| 21 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 22 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 23 | Group A |
| 24 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | 20 mm |
| 26 | 25 mm |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 28 | 2X10 sq. mm +1X 6 sq. mm earth wire |
| 29 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V,on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 31 | 8 way, Double door |
| 32 | 6 way, Double door |
| 33 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Single pole |
| 35 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 36 | 63 A |
| 37 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 38 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 39 | 1x1.5 sq.mm |
| 40 | 2x1.5 sq.mm |
| 41 | 2x2.5 sq.mm |
| 42 | 2x4 sq.mm |
| 43 | Supply and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 44 | 3 X 70 sq mm |
| 45 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 46 | Upto 35 sq. mm |
| 47 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 48 | Providing and laying earth connection from earth electrode with 6 SWG dia G.l. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 49 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 50 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100 lm. |
| 51 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hzcomplete i/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No.Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 52 | Supply, Installation, testing and commissioning of 12 watt, ceiling circular light for domestic grade, surge protection upto 3 kV & wide voltage protection 160-360 V, 50 Hzcomplete i/c all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make philips, Cat No.Full Glow 12W, WW/NW/CDL or equivalent model of Thorn/Trilux |
| 53 | Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C x 16 sqmm etc as required. |
| 54 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |
| 55 | Supply, erection, Testing and comissioning of hot dip galvanized octagonal steel pole of 5 Metre height made out of 3mm thick sheet PCD 200 mm, having bottom 130mm A/F & top 70mm A/F with built in connector box of size 500 mm length, M.S. base plate of size 200mm x 200mm x12mm thickto accommodate the fittingon existing RCC foundation including Supply and fixing of 4 Nos. M-16 x 450mm long J Type (EN-8 grade) G.I. foundation bolts, 12 Nos. of Nut, 4 Nos. ofwasher along with suitable size templates, making connections, interconnections with suitable size of copper wire with timble/lugs in the connection box, earthing, making numbering of pole etc. complete as per drawing & technical specifications attached including following accessories mounted on inbuilt control box having flush cover with 2 Nos mounting strips with tapped holes (a) 6mm thick phjenolic laminated sheet/ bakelite sheet inside the window mounted on the existing mounting strips inside the flush door(b) Supply and fixing of Teriminalblock suitable for 16 sq. mm conductor4 Nos. & shorting links - 5 Nos. on DIN Chneels (c) Terminal suitable for 6 SWG GI Wire/ 1.5 sq. mm wire (d) 6 Amp SPMCB 10 KA \"C\" Series - 1 No. including mounting on DIN Channel This includes making of founation of size 1200 mm x 400 mm x 400 mm made of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) with proision of IN and OUT slot for cable entry including excavation and refilling etc. as required. (Make : Bajaj/ Transrail/Jindal/Tata) |
| 56 | Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No.BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux |
| 57 | Supplying and Fixing of 500 mm longOver hang double arm bracket made of suitable dia G.I. pipe and suitable for 70 mm dia G I Pole including Nut bolts etc. as required. (Make : Bajaj/ Paruthi/ Surya) |
| 58 | Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz , Meter panel, IP 65 (outdoor type) fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having capacity extensible type DMC / SMC FP bus bars of high conductivity,DMC/ SMC bus bar supports , bottom base channel of MS section of suitable size, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size ofbus bars etc.complete in all respect as per CPWD specificationcomplete with necessary accessories, wiring with 2.5 sq. mm. FRLSH insulated copper conductor , cable alleys, cable glandand following incoming and outgoing switchgears with protection andmetering etc.as required at site. All MCCBs above 63A should be provided with Spreader Terminals. Approval shall be taken for each panel before fabrication.Incomer100A FP MCCB (25kA)with thermal magnetic based O/L & S/C protection -1 Nos., Incomer should be Suitable for cable termination. RYB on, off trip indication lamp-1 set., Multi-Function Meter with CT- 100/5A class-1.0 10 VA -03 nos.Busbar 150A TPN Al busbar Extensible typeOutgoing :1. 63A DP MCB (10kA) -6 Nos.2. Space for single phase energy meter with lockable arrangement :- 06 Nos.Connecting terminal (Inside cable alley) of all MCB should be suitable for connection with Aluminium armoured cable upto size 16 sqmm. |