| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wireinexistingsurface/recessedsteel/PVC conduit including dismantling as required.Group B |
| 2 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 4 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 5/6 A switch |
| 5 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 15/16 A switch |
| 6 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 7 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 8 | Bell push |
| 9 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
| 10 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 11 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 12 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 13 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 14 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 15 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm) |
| 16 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150nnm) |
| 17 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 18 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 20 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socketoutletand 25 A modularSPMCB,\"C\"curveincluding connections, painting etc. as required. |
| 21 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 22 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 23 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 24 | Supply, installation, testing and commissioning of plastic body exhaust fan of 200 mm sweep, suitable for operation on 230 V, 50 Hz, single phase AC supply, 1585 RPM, with air delivery of minium 700 CMH in the existing opening, including making good the damages, connection with suitable size cable, testing and commissioning etc., as required make Crompton Greaves model. Ventitus HS exhause fan or equivalent model of Almonard/Atomberg. |
| 25 | Supply, Installation, testing and comissioning of 12 Inch heavy duty AC, single phase 230 Volt, 50 Hz, 1350 RfPM, steel body exhauset fan in the existing opening, including, making good the damage cable connection etc. as required. |
| 26 | Suuply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover esign, 18 watt, 2100 Im, 50000 burnining hours, sie 1200mm complete i/c all accessories etc. directly on ceiling/wall, i/c connection with 1.5 sqmm FRLS PVC insulated, copper conductor cable and earthing etc. as required fitting equivalent to Philips make, Cat no. TMC 502 1xT LED 22W, Tube equivalent to Philips Make, Cat no. Mas lED Tube 1200mm 18W 865 TBI-2100Im. |
| 27 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with IP66 protection and IK09 impact reststance suitable for surface and wall mounting application, 220-240 V, 50Hz complete i/c all accessories etc. directly on surface i/c connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc. as required make Philips, Model Endurs LED Bulk head Cat No. WT202W LED 105 CW PSU 53 PC or equivalent model of Thorn/Trilux. |
| 28 | Supply, Installation, testing and commissioning of 12 watt, ceiling circular light for domestic grade suge protection upto 3 KV & vide voltage protection 160-360 V 50 Htz complete i/c all accessories etc. directly on furface i/c connection with 1.5 sq mm FRLS PVC insulated copper conductor cabe and earthing etc. as required Make philips Cat no. full glow 12W, WW/NW/CDL or equivalent model of Thorn/Trilux. |
| 29 | Supply, Installation, testing and commissioning of prewired wall mounted fancy white light suitabe forinstallation of LED bulb, 220-240 V, 50 Hz complete i/c all acccessories but without bulb etc. i/c connection etc. complete as required Make Philips, Cat No. Comet wall fancy light 822 or eqquivalent model of Thorn/Trilux. |
| 30 | Dismantling of ceiling fan/exhause fan/Light fitting etc. i/c disconnection of wires/cable and submission of same in department store etc. complete as requiredl. |