| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 8 | 50 mm |
| 9 | Supplying and fixing modular blanking plate on the modular plate & switch box but excluding modular plate as required. |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 11 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc as required. |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 13 | Supplying, installation, testing & commissioning of 20/22 watt LED tube light fitting suitable for single phase AC 230 V complete with accessories connection etc as required. (Make- Havells/Crompton/Philips/Bajaj/C&S/Surya) |
| 14 | Supplying,installation ,testing and commissining of 3 phase Under/over voltage Protection Relay with adjustable setting,complete with wiring and interlocking with 100 A,25 KA breaking capacity , thermomagnetic releaseand terminal spreaders,4 pole MCCB with complete enclosure size of 500 x500mmx400mm cubicle panel board for connection and protection of 300 mA X ray machine including Ammetre and voltmeter , complete wiringmaking connections, etc. as required.Legrand make |
| 15 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 16 | 8 way, Double door |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Single pole |
| 19 | Single pole and neutral |
| 20 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 22 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 23 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 24 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 25 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 26 | Jointing copper/GI tape (with another copper/GI tape, base of the finial oe any other metallic object) by riveting/nut bolting/sweating and soldering etc as required. |
| 27 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run) |
| 28 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 29 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 30 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 31 | 3½ X 50 sq. mm (32mm) |
| 32 | Supplying and laying of following sizeDWC HDPE pipe ISImarked along with all accessories like socket, bend, couplersetc.conforming toIS 14930, Part II complete with fitting andcutting, jointing etc.direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. |
| 33 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 34 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 3.5 x 50 Sqmm size in the existing DWC HDPE/METAL PIPE/OPENas required. Make-Havells/Polycab/RR Kabel/Finolex/KEI/Plaza |
| 35 | Supply , Installation, Testing and Comissioning of Air Cooled HiWall split type Air conditioners complete with Indoor unit(IDU),Out door unit (ODU), surface / concealed copper Refrigerantpiping with insulation (closed cell elastomeric nitrile rubbertubular pipe section) upto 3 Mtr (IDU to ODU), copper powercable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable forworking between 180-260V with low & high voltage cutoff and50 hz ,1 phase AC supply capable of performing cooling,dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year OriginalEquipment Manufacturer (OEM)warranty both compressor and Printed Circuit Board (PCB).Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS /InternationalElectrotechnical Commission (IEC) 60730, hermetic compressorIS 10617, heat exchanger IS 11329, capacitor IS 2993 andmotor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 500C (out door ambient temperature) |
| 36 | 0.75 TRwith 5 Star BEE Rating |
| 37 | 2.0 TR with 5 Star BEE Rating |
| 38 | Supplying and fixing of 4 KVA 150 V to 280V rating volatge stabilizer suitable for 1.5 ton split type inverter Air Conditioner incuding connection, testing etc complete as required. Make V-Guard/Bluebird/Voltas or equivalent |
| 39 | Supplying and fixing of 5 KVA 150 V to 280V rating volatge stabilizer suitable for 2 ton split type inverter Air Conditioner incuding connection, testing etc complete as required. Make V-Guard/Bluebird/Voltas or equivalent |
| 40 | Providing, Installation, Testing and Commissioning of out door type totally enclosed weather proof feeder panel with sloping canopy top of suitable size (minimum size 900mm × 600mm × 400mm) having viberation free structure chemically treated with 7 tank process before painting for surface treatment and powder coated with seven tank process to accommodate following switchgears and accessories, fabricated from 14 SWG/2 mm thick CRCA sheet suitable for 415 volts, 50 Hz A.C. supply with gland plate, hinged front openable double leaf doors and locking arrangement, suitable size 4 strip 200 Amp Al. busbar. Including providing and fixing following switchgears and accessories, powder painted with approved shade, including connection / interconnections with FRLS PVC insulated copper conductor single core cable of suitable size and danger notice plate size 150 × 100 mm etc. complete as required.The feeder pillar shall be supplied with suitable pedestal of 50 mm × 50 mm × 6 mm angle iron frame with 600 mm long legs. The feeder pillar shall be mounted on suitable brick / cement concrete foundation 30 cms. below ground level and 30 cms. above ground including finishing etc. complete as required. Fabrication of feeder pillar size – 900 mm(H) × 600 mm(W) × 400 mm(D)made of 2 mm thick CRCA sheet i/c welding, painting, locking arrangement and 50 mm × 50 mm × 6 mm angle iron with 600 mm long legs160 Amp, 4 pole MCCB with thermomagnetic release, 35 KA breaking capacity 01 nos make L&T/Havells/C&S 100Amp, 4 pole MCCB, 25 KA breaking capacity make L&T/Havells/C&S – 01 NosDP MCB ‘C’ series 10 KA 40 Amps – 05 NosVoltmeter (Range : 0–500V) : 01 NosAmmeter (Range : 0–100A) : 01 NosPhase indicating LED lamp : 03 Nos |
| 41 | Providing, Installation, Testing and Commissioning of out door type totally enclosed weather proof Joint BOX with sloping canopy topof suitable size (minimum size 600 mm x 450 mm x 450 mm having viberation free structure chemically treated with 7 tank process before painting for surface treatment and powder coated suitable for 415V, 3Phase, 50Hz, 4 wire system fabricated out of CRCA sheet upto 2mm thick duly compartmentalized for bus section, complete with hinged doors having locking arrangement and providing detachable gland plate at the bottom of the box, complete with 200 Amps 4 Nos insulated aluminium bus bar supplied with suitable pedestal of 50mm x 50mm x 6 mm angle iron with 1000 mm long legs (Minimum size of panel should be 600 mm x 450 mm x 450 mm)The feeder pillar shall be supplied with suitable pedestal of 50 mm × 50 mm × 6 mm angle iron frame with 600 mm long legs. The Joint Boxshall be mounted on suitable brick / cement concrete foundation 30 cms. below ground level and 30 cms. above ground including finishing etc. complete as required. |