| 1 | Single Pole Structure STPSTP Pole 11 Mtr. Long |
| 2 | Stone Pad 300 x 300 x 75 mm |
| 3 | 11 KV V-Type Cross Arm |
| 4 | Holding Clamp For X Arm for STP |
| 5 | 11 KV Polemeric pin insulator. |
| 6 | F Bracket For STP. |
| 7 | Danger Board with Clamp. |
| 8 | Barbed Wire G.I.. |
| 9 | Concreting of Pole. |
| 10 | Earthing Complete. |
| 11 | G.I. Wire 6 SWG For Earth wire. |
| 12 | Number Plate with fitting. |
| 13 | HT Line Road CrossingSTP Pole 11 Mtr. Long |
| 14 | Stone Pad 300 x 300 x 75 mm |
| 15 | G.I. Stay Set Complete 16 x 1800 mm |
| 16 | Stay Wire 7 / 10 SWG |
| 17 | Earthing Complete. |
| 18 | G.I. Wire 6 SWG For Earth wire. |
| 19 | Aluminium Paint |
| 20 | Red Oxside Paint. |
| 21 | Concreting of ST Pole. |
| 22 | Cross Arm V-Type |
| 23 | Cross Arm Holding Clamp. |
| 24 | Number Plate with fitting. |
| 25 | Barbed Wire G.I.. |
| 26 | Danger Board with Clamp. |
| 27 | Gaurding Angle. |
| 28 | Gaurding Angle Holding Clamp. |
| 29 | G.I. Wire 6 SWG For Earth wire. |
| 30 | Section Pole StructureSTP Pole 11 Mtr. Long |
| 31 | Stone Pad 300 x 300 x 75 mm |
| 32 | Concreting of ST Pole. |
| 33 | Top Channel M.S. 100 x 50 x 6 mm (2240 mm) |
| 34 | Dropper Channel 100 x 50 x 6 mm. (2000 mm) |
| 35 | Clamp with bolt & Nut for Top & Droper. |
| 36 | Barbed Wire G.I.. |
| 37 | M.S. Iron Angle 65 x 65 x 6 mm, 2028 mm long Bracing Angle. |
| 38 | Danger Board with Clamp. |
| 39 | Earthing Complete. |
| 40 | G.I. Wire 6 SWG For Earth wire. |
| 41 | 11 KV Polemeric pin insulator. |
| 42 | 11 KV Polemeric disc insulator 45 KN |
| 43 | PG Clamp for weasel. |
| 44 | G.I. Stay Set Complete 16 x 1800 mm |
| 45 | Stay Wire 7 / 10 SWG |
| 46 | Number Plate with fitting. |
| 47 | Aluminium Paint |
| 48 | Red Oxside Paint. |
| 49 | F Bracket For STP. |
| 50 | Double Pole CTPT STP Pole 11 Mtr. Long |
| 51 | Stone Pad 300 x 300 x 75 mm |
| 52 | Concreting of ST Pole. |
| 53 | Top Channel M.S. 100 x 50 x 6 mm (2240 mm) |
| 54 | Clamp with bolt & Nut for Top & Droper. |
| 55 | M.S. Angle 65 x 65 x 6 mm. |
| 56 | Barbed Wire. |
| 57 | Danger Board with Clamp. |
| 58 | Earthing Complete. |
| 59 | G.I. Wire 6 SWG For Earth wire. |
| 60 | 11 KV Polemeric pin insulator. |
| 61 | PG Clamp for weasel. |
| 62 | G.I. Stay Set Complete 16 x 1800 mm |
| 63 | Stay Wire 7 / 10 SWG |
| 64 | Number Plate with fitting. |
| 65 | Aluminium Paint |
| 66 | Red Oxside Paint. |
| 67 | LT Line Road CrossingSTP Pole 11 Mtr. Long |
| 68 | Stone Pad 300 x 300 x 75 mm |
| 69 | Concreting of ST Pole. |
| 70 | ABC Cable 3 x 95 + 1 x 70 + 1 x 16 Sq. mm |
| 71 | Earthing Complete. |
| 72 | G.I. Wire 6 SWG For Earth wire. |
| 73 | G.I. Stay Set Complete 16 x 1800 mm |
| 74 | Stay Wire 7 / 10 SWG |
| 75 | I Hook |
| 76 | LT Clamp for PCC |
| 77 | Suspention Clamp |
| 78 | Bolt & Nut For Washer. |
| 79 | Aluminium Paint |
| 80 | Red Oxside Paint. |
| 81 | LT Line with ABCPCC Pole 8.5 Mtr. Long |
| 82 | Stone Pad 300 x 300 x 75 mm |
| 83 | Concreting of ST Pole. |
| 84 | Earthing Complete. |
| 85 | G.I. Wire 6 SWG For Earth wire. |
| 86 | G.I. Stay Set Complete 16 x 1800 mm |
| 87 | Stay Wire 7 / 10 SWG |
| 88 | Distribution Box (D.G.) |
| 89 | Distribution Clamp |
| 90 | I Hook |
| 91 | LT Clamp for STP |
| 92 | Dead end Clamp. |
| 93 | Suspention Clamp |
| 94 | ABC Cable 3 x 95 + 1 x 70 + 1 x 16 Sq. mm |
| 95 | ABC Cable 3 x 50 + 1 x 35 + 1 x 16 Sq. mm |
| 96 | Bolt & Nut For Washer. |
| 97 | ACSR Weasel Conductor |
| 98 | G.I. Stay Set Complete 16 x 1800 mm |
| 99 | Stay Wire 7 / 10 SWG |
| 100 | 11 KV disc insulator |
| 101 | T-Off Channel |
| 102 | T-Off Clamp |
| 103 | Total |
| 104 | Labour Charge @ 30 % of BOQ Dismantalling of Old Line/Material & Diposite to store including Cartage Errection with T & P Laying Testing & Commisioning etc. Please Enable Macros to View BoQ information |