| Sl. No. | Item Description |
| 1 | Disconnecting incoming and outgoing cable/busbar connections, taking out from the cradle and overhauling of manually/electrically operated, draw out type air circuit breaker of any make, 03 or 04 pole, 415 volts, AC, current rating 800 A Make C &S complete all as specified and directed as under - (a) Cleaning of dust, spider web, foreign particles etc. (b) Removal of old grease from various parts. (c) Cleaning of various parts with CRC-2-26. (d) Check the tightness of all hardware. (e) Replacement of damaged parts. (f) Re-greasing and lubricating of all rotating, moving parts. (g) Checking, setting and fault attending of spring charging mechanism operation. (h) Checking, setting and fault attending of closing and tripping mechanism operation. (j) Checking, setting and fault attending of breaker auxiliary switch contact healthiness. (k) Checking of breaker operation in isolating / test and service position. (l) Confirming of Insulation resistance value of each live part w.r.t earth. (m) C & S ACB Spares complete all as specified and directed. |
| 2 | Supply and Fixingin repair Motor Auxiliary isolating contact assembly CS-AIH-2-116(4P) complete all as specified and directed. |
| 3 | Supply and Fixingin repair Motor Compact UVT Coil6D- 16D/06N-2OS, CS-AUH-V-A-NA complete all as specified and directed. |
| 4 | Supply and Fixingin repair Motor Shunt Trip 6D-16D/06N-2OS,CS-AVH-S-116-MA complete all as specified and directed. |
| 5 | Supply and Fixingin repair Motor Closing Coil 6D-16D/06N-2OS,CS-AVH-S-116-MA complete all as specified and directed. |
| 6 | Supply and Fixingin repair Motor Arcing Contact, CS-ARCCONT-O8D complete all as specified and directed. |
| 7 | Supply and Fixingin repair Motor Main isolating Contact(Jaw Contacts) CS-MIC-O8D(50k) complete all as specified and directed. |
| 8 | Supply and Fixingin repair Motor Cradle terminal for drawout AHACB complete all as specified and directed. |
| 9 | Supply and Fixingin repair Motor Arc Chutes complete all as specified and directed. |
| 10 | Supply and Fixingin repair Spring Charging Motors (220Volts AC / DC) complete all as specified and directed. |
| 11 | Supply and Fixingin repair Motor Control relay for charging Motor (220 V AC) complete all as specified and directed. |
| 12 | Supply and Fixingin repair Motor Micro switch for motor cut off 6 D complete all as specified and directed. |
| 13 | Supply and Fixingin repair Motor Drawout Handle complete all as specified and directed. |
| 14 | Supply and Fixingin repair Motor Complete lower mechanism assly of 800 A complete all as specified and directed. |
| 15 | Supply in repair /replacement of U V coil 440 Volts AC complete all as specified and directed. |
| 16 | Supply and Fixingin repairContractor coil 240 Volts AC Make- TC (630/800 Amps Contractor) complete all as specified and directed. |
| 17 | Disconnecting incoming and outgoing cable/busbar connections, taking out from the cradle and overhauling of manually/electrically operated, draw out type following air circuit breaker of any make, 03 or 04 pole, 415 volts, AC, current rating 630 to 2500 A Make : L & T complete all as specified and directed as under - (a) Cleaning of dust, spider web, foreign particles etc. (b) Removal of old grease from various parts. (c) Cleaning of various parts with CRC-2-26. (d) Check the tightness of all hardware. (e) Replacement of damaged parts. (f) Re-greasing and lubricating of all rotating, moving parts. (g) Checking, setting and fault attending of spring charging mechanism operation. (h) Checking, setting and fault attending of closing and tripping mechanism operation. (j) Checking, setting and fault attending of breaker auxiliary switch contact healthiness. (k) Checking of breaker operation in isolating / test and service position. (l) Confirming of Insulation resistance value of each live part w.r.t earth. |
| 18 | (i) 800A S1 EDO 3P SR18G |
| 19 | (i) CN-CS 1000C EDO 3P |
| 20 | (ii) 1600A S1 MDO 3P SR18 |
| 21 | (iii) 1600A S1 EDO 3P SR18G |
| 22 | (iv) 1600A S1 EDO 4P SR18G |
| 23 | (v) 2000A S1 EDO 4P SR18G |
| 24 | (vi) 2500A S1 EDO 3P SR18G |
| 25 | NOTE FOR ITEM NO 1.00 to 17.07:-1. The contractor has to submit detail service report for each breaker over-hauled. 2. All the necessary tools and tackles shall be arranged by contractor for the subject work. 3. The contractor has to replace minor spares like spring washers, washers locking pin, circlip, spring, small nut-bolts etc. free of cost. 4. Contractor has to arrange for necessary cleaning agent (petrol, diesel, CRC 2-26 etc.) and lubricating material like grease, oil and lubricating sprays if any, as required for subject work. 5. The servicing / overhauling of breaker is to be carried out at site. However, if any breaker requires to be taken to contractor’s work-shop, then contractor has to arrange transportation of such breakers from site to Work-shop and back to site without extra cost. 6. Major spares required to be replace during servicing will be measured and paid under relevant item as specified in the schedule hereforth.7. Load break test should done in front of Engineer-in-Charge.8. All required load bank should be carried by Contactor without extra cost.9. Servicing work done with prior permission of Engineer-in-Charge as breaker installed inside the hospital.10. All working executive must performed technical qualification and necessary exprience of work. |
| 26 | Supply and Fixing in repairPole Assy. 400-1250 S1 D/Ocomplete all as specified and directed. |
| 27 | Supply and Fixing in repairPole Assy. 1600 S1 D/O complete all as specified and directed. |
| 28 | Supply and Fixing in repairPole Assy. 2000 S1 D/O complete all as specified and directed. |
| 29 | Supply and Fixing in repairPole Assy.2500 S1 D/O complete all as specified and directed. |
| 30 | Supply and Fixing in repairCTs for SR18 800S1 complete all as specified and directed. |
| 31 | Supply and Fixing in repairCTs for SR18 1600S1 complete all as specified and directed. |
| 32 | Supply and Fixing in repairCTs for SR18 2000S1 complete all as specified and directed. |
| 33 | Supply and Fixing in repairCTs for SR18 2500S1 complete all as specified and directed. |
| 34 | Supply and Fixing in repairJaw contact Assy 400-1250A S1 complete all as specified and directed. |
| 35 | Supply and Fixing in repairJaw contact Assy 1600S1 complete all as specified and directed. |
| 36 | Supply and Fixing in repairJaw contact Assy. 2500 S1 complete all as specified and directed. |
| 37 | Supply and Fixing in repairVertical Terminal Adapter 400-1250 S1 complete all as specified and directed. |
| 38 | Supply and Fixing in repairVertical Terminal Adapter 1600/2000 S1 complete all as specified and directed. |
| 39 | Supply and Fixing in repairVertical Terminal Adapter 2000 C complete all as specified and directed. |
| 40 | Supply and Fixing in repairVertical Terminal Adapter 2500 S1 complete all as specified and directed. |
| 41 | Supply and Fixing in repairArc Chute 630-1250 S1 complete all as specified and directed. |
| 42 | Supply and Fixing in repairArc Chute 1600/2000S1 complete all as specified and directed. |
| 43 | Supply and Fixing in repairArc Chute 2500 C/H/S1 complete all as specified and directed. |
| 44 | Supply and Fixing in repairFixed Arcing Contact 630-1250 S1 complete all as specified and directed. |
| 45 | Supply and Fixing in repairFixed Arcing Contact 1600 S1 complete all as specified and directed. |
| 46 | Supply and Fixing in repairFixed Arcing Contact 2000 S1 complete all as specified and directed. |
| 47 | Supply and Fixing in repairFixed Arcing Contact 2500S1 complete all as specified and directed. |
| 48 | Supply and Fixing in repairMoving Arcing Contact 630-1250 S1 2000S1 complete all as specified and directed. |
| 49 | Supply and Fixing in repairMoving Arcing Contact 2500 Amps complete all as specified and directed. |
| 50 | Supply and Fixing in repairShutter Assy. 400-2000 S1 complete all as specified and directed. |
| 51 | Supply and Fixing in repairShutter Assy. Supply and Fixing in repair 3200 S1 complete all as specified and directed. |
| 52 | Supply and Fixing in repairCradle Terminal Assy. 400-1250 S1 complete all as specified and directed. |
| 53 | Supply and Fixing in repairCradle Terminal Assy. 1600/2000 S1 complete all as specified and directed. |
| 54 | Supply and Fixing in repairCradle Terminal Assy. 2500 S1 complete all as specified and directed. |
| 55 | Supply and Fixing in repairCradle Terminal support 400-1250 S1 complete all as specified and directed. |
| 56 | Supply and Fixing in repairCradle Terminal support 1600/2000A S1 complete all as specified and directed. |
| 57 | Supply and Fixing in repairCradle Terminal support 2500S1 complete all as specified and directed. |
| 58 | Supply and Fixing in repairShunt Release EA 220V DC complete all as specified and directed. |
| 59 | Supply and Fixing in repairUnder-voltage Release 240V AC complete all as specified and directed. |
| 60 | Supply and Fixing in repairClosing Coil 240V AC/ 220V DC complete all as specified and directed. |
| 61 | Supply and Fixing in repairFRCD 400-3200S1 (3P & 4P) complete all as specified and directed. |
| 62 | Supply and Fixing in repairLeft-plate Assy 400-3200 S1 complete all as specified and directed. |
| 63 | Supply and Fixing in repairMotor 240V AC complete all as specified and directed. |
| 64 | Supply and Fixing in repairSpring charge motor gear assembly complete all as specified and directed. |
| 65 | Supply and Fixing in repairSpring charge limit switch complete all as specified and directed. |
| 66 | Supply and Fixing in repairSpring charge motor assembly plunger complete all as specified and directed. |
| 67 | Supply and Fixing in repairPower Contact 800 amps complete all as specified and directed. |
| 68 | Supply and Fixing in repairBezal of L&T BrakerSr.No SL916020000 complete all as specified and directed. |
| 69 | Supply and fix in repair following type MCCBs in various panels complete all as specified and directed. |
| 70 | MCCB 400 Amp four pole, Fixed thermal magnetic type 415 volts, 36 kA, suitable for existing of panel and as per sample |
| 71 | MCCB 300 Amp to 350 Amp four pole, 415 volts, 36 kA suitable for existing of panel and as per sample |
| 72 | MCCB 250 Amp four pole,Fixed thermal magnetic type 415 volts, 36 kA suitable for existing of panel and as per sample |
| 73 | MCCB 200 Amp four pole,Fixed thermal magnetic type 415 volts, 36 kA suitable for existing of panel and as per sample |
| 74 | MCCB 160 Amp four pole,Fixed thermal magnetic type 415 volts, 25 kA suitable for existing of panel and as per sample |
| 75 | MCCB 125 Amp four pole,Fixed thermal magnetic type 415 volts, 25 kA suitable for existing of panel and as per sample |
| 76 | MCCB 100 Amp four pole,Fixed thermal magnetic type 415 volts, 25 kA suitable for existing of panel and as per sample |
| 77 | MCCB 63 Amp four pole,Fixed thermal magnetic type 415 volts, 25 kA suitable for existing of panel and as per sample |
| 78 | Supply and fix in repair 3 Pole 630/800 Amps contractor with 2 NO + 2 NC operation coil voltage 230 Volt AC and having interlocking arrangement as per existing contractor installed at change over panel at MRS MH Kirkee complete all as specified and directed. |
| 79 | Supply and fix in repair 3 Pole 315/400 Amps contractor with 2 NO + 2 NC operation coil voltage 230 Volt AC and having interlocking arrangement as per existing contractor installed at change over panel at MRS MH Kirkee complete all as specified and directed |
| 80 | Material and Labour in repair for Control wiring of ACB Panel with using suitable size PVC tray of required size including all necessary material/hardware as per existing parameter and manutacturers specification complete all as specified and directed |
| 81 | Supply and Fix in repair Rectifier Unit as per exsting panel complete all as specified and directed |
| 82 | Supply and Fix in repair SMPS Units with incoiming 240 VAC and outgoing 24 VAC as per exsting panel complete all as specified and directed |
| 83 | Supply and Fix in repair PLA relay with 5/8/11 pin and base as per exsting panel complete all as specified and directed |
| 84 | Supply and Fixing in repair on delay timer for ACB in distribution panel along with necessary timer setting as per site requirement complete all as specified and directed |
| 85 | Supply and Fixing in repair control break switch as per site requirement complete all as specified and directed |
| 86 | Material and Labour in repair for following APFC panel by replacing old U/S damaged electrical components parts and providing new partscomplete all as specified and directed as under |
| 87 | 50 KVAR APP type capacitor Heavy Duty |
| 88 | 25 KVAR APP type capacitor Heavy Duty |
| 89 | 20 KVAR APP type capacitor Heavy Duty |
| 90 | 12.5 KVAR APP type capacitor Heavy Duty |
| 91 | 10 KVAR APP type capacitor Heavy Duty |
| 92 | Supply and Fixing in repair heavy duty power contactor for capacitor of 50 KVAr complete all as specified and directed |
| 93 | Supply and Fixing in repairheavy duty power contactor for capacitor of 25 KVAr complete all as specified and directed |
| 94 | Supply and Fixingin repair heavy duty power contactor for capacitor of 20 KVAr complete all as specified and directed |
| 95 | Supply and Fixingin repair heavy duty power contactor for capacitor of 12.5 KVAr complete all as specified and directed |
| 96 | Supply and Fixingin repair heavy duty power contactor for capacitor of 10 KVAr complete all as specified and directed |
| 97 | Supply and Fixing in repair 400A FN Type switch with bollet HTC Fuse complete all as specified and directed. Make L & T |
| 98 | Supply and Fixingin repair APFC Relay meter for 08 stage suitable for existing panel of 144 x 144 mm size complete all as specified and directed |
| 99 | Supply and Fixing in repairAPFC Relay meter for 12 stage suitable for existing panel of 144 x 144 mm size complete all as specified and directed |
| 100 | Supply and Fixing in repair 80 A control fuse links top and base complete all as specified and directed |
| 101 | Supply and Fixing in repair 63 A control fuse links top and base complete all as specified and directed |
| 102 | Supply and Fixing in repair 40 A control fuse links top and base complete all as specified and directed |
| 103 | Supply and Fixing in repair 32 A control fuse links top and base complete all as specified and directed |
| 104 | Supply and Fixing in repair Illuminated push buttons red/green complete all as specified and directed |
| 105 | Supply and Fixing in repair LED type RYB indicating lamps (set of three) complete all as specified and directed |
| 106 | Supply and fix in repair Voltage meter as per site requirement sutable incoming braker complete all as specified and directed |
| 107 | Supply and fix in repair Amps meter as per site requirement sutable incoming braker complete all as specified and directed |
| 108 | Supply & Fixin repair selector switch of 3 stage on - off - on suitable for existing panel complete all as specified and directed |
| 109 | Supply & Fix in repairselector switch of 3 stage on - on - on suitable for existing panel for volt / amps meter complete all as specified and directed |
| 110 | Supply and fixin repair any size id any shape of CT for Ammeter of capacity upto 800/5 complete all as specified and directed |
| 111 | Supply and fix including taking down of burnt aluminum bus bar of any size and capacity and fix with all necessary provision cutting, bending, drilling, fixing with nut bolt washers complete all as specified and directed |
| 112 | Servicing of LT indoor/outdoor Panel/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, cleaning of dust with air blower, replacement of unserviceable MCCBs, burnt busbars, burnt thimbles, unserviceable indicator lamps, unserviceable Ammeter,unserviceable Volt meter, reconnections after proper cleaning of contacts with CRC solution and fixing of hanging front and rear openings with new hinges welding etc. including painting of complete panel included stand (after proper scrubbing) with synthetic enamel paint (ordinary tint) one coat as per specified colour code including writing of panel/feedar panel location using black systhetic paint complete all as specified and directed Note : (i) Cost of labour, painting of panel, cotton waste insulator and thimbles and T&P required for upkeeping/maint work is inclusive in quoted rate. (ii) MCCBs, Bus bars, indicator lamps, Ammeter, Volt meter, will be measured & paid separately as supply only . |
| 113 | Supply and Fixing Change over of capacity 100 amps 4 pole including taking down of old change over removing all connected cable and fixing of new change over with all suitable connection complete all as specified and directed |
| 114 | All as per item No92but for 250 Amps complete all as specified and directed. |
| 115 | Supply and fixin repair LT change over Switch with enclosure 800 Amp complete all as specified and directed. Make- L&T |
| 116 | Taking down unserviceable cable of any size upto 300 sq mm carefully from trenches / poles / ducts / LT Panel OH conducts and relay at different locations complete all as specified and directed |
| 117 | Supply and Fix for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 3.5 core including aluminium cable gland, nut bolts washers & lugs, complete all as specified and directed |
| 118 | All as per item No 96 but for 50 sqmm 3.5 core |
| 119 | All as per item No 96 but for 70 sqmm 3.5 core |
| 120 | All as per item No 96 but for 120 sqmm 3.5 core |
| 121 | All as per item No 96 but for 150 sqmm 3.5 core |
| 122 | All as per item No 96 but for 185 sqmm 3.5 core |
| 123 | All as per item No 96 butfor 240 sqmm 3.5 core |
| 124 | All as per item No 96 but for 300 sqmm 3.5 core |
| 125 | Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in soft / loose soil and getting out in soft / loose soil complete all as specified and directed |
| 126 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed |
| 127 | Removing excavated meterial to a distance n.exc50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed |
| 128 | Material and Labour for riddle earth cushioning including spreading, levelling and hand punning to underground cable in trench complete all as specified and directedNote : Punned thickness shall only be measured and paid. |
| 129 | Material and Labour for PCC cable cover class LV, type-I, flat size 250mmx150mmx40mm factory casted ISI marked complete all as specified and directed. |
| 130 | Supply & Fixing Heat shrink straight through joint LT 1100 volts grade 25 sqmm to 50 sqmm, 3.5 core / 4 core complete all as specified and directed.Make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M |
| 131 | Supply & Fixing Heat shrink straight through joint LT 1100 volts grade 70 sqmm to 120 sqmm, 3.5 core / 4 core complete all as specified and directed.Make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M |
| 132 | Supply & Fixing Heat shrink straight through joint LT 1100 volts grade 150 sqmm to 185 sqmm, 3.5 core / 4 core complete all as specified and directedMake-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M |
| 133 | Supply & Fixing Heat shrink straight through joint LT 1100 volts grade 240 sqmm to 300 sqmm, 3.5 core / 4 core complete all as specified and directedMake-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M |
| 134 | Supply & Fixing Heat shrink straight through joint LT 1100 volts grade 400 sqmm to 630 sqmm, 3.5 core / 4 core complete all as specified and directedMake-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M |
| 135 | Supply & Fixing in repair Air Circuit Breaker 4 Pole, 415 V with thermal Magnetic Release (Manual Drowout Type) with microprocessor release of Capacity 2000A with 50 kA breaking capacity, Ics=100%Icu (Utilization Category B) complete all as specified and directedMake- L&T |
| 136 | Supply & Fixing in repair Air Circuit Breaker 3 Pole, 415 V with thermal Magnetic Release (Manual Drowout Type) with microprocessor release of Capacity 800A with 50 kA breaking capacity, Ics=100%Icu (Utilization Category B) complete all as specified and directedMake- L&T/ C&S (as per ground requirement) |
| 137 | Supply, install testing and commissioning in replacement factory madeout door typeLT panel board of size not less than 1mtrX1mtrX0.30 mtr, 440 volts , 3 phase , 4 wire system with powder coating providedto make it dust /vermin proof manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCA sheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 600 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories complete all as specified and directed:- |
| 138 | Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size.(ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size.(iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminumlugs of suitable rating incommensurate with that of switchgear.(iv)Cable glands would be provided for incoming & out going cables in panels.(v)The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item.(vi)The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level. |
| 139 | Aluminium bus bar strips with proper colour code -04 No, 600 A cap, insulator, nuts bolts etc complete. |
| 140 | Indicator Lamp-01 Set (Set of three) |
| 141 | IncommerMCCB 4P315Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No |
| 142 | Outgoing, MCCB 4P250amp, 415V, 36 KAIcs = 100 Icu Adjustable type - 01 No |
| 143 | Outgoing, MCCB 4P63 amp, 415V, 25 KA Ics = 100 Icu Adjustable type- 01 No ( Spare MCCB) |
| 144 | Digital Voltmeter 0-500 Vand Digital Ampmeter0-300A.with selector switch Make-Legrand |
| 145 | Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. |
| 146 | Supply, install testing and commissioning in replacement factory madeout door typeLT panel board of size not less than 1mtrX1mtrX0.450 mtr, 440 volts , 3 phase , 4 wire system with powder coating providedto make it dust /vermin proof manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCAsheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 600 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories complete all as specified and directed:- |
| 147 | Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size.(ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size.(iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminumlugs of suitable rating incommensurate with that of switchgear.(iv)Cable glands would be provided for incoming & out going cables in panels.(v)The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item.(vi)The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level. |
| 148 | Aluminium bus bar strips with proper colour code -04 No, 600 A cap, insulator, nuts bolts etc complete. |
| 149 | Indicator Lamp-01 Set (Set of three) |
| 150 | IncommerMCCB 4P,315Amp, 415V, 50 KA Ics = 100 Icu Adjustable type - 01 No |
| 151 | Outgoing, MCCB 4P, 160 amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 01 No |
| 152 | Outgoing, MCCB 4P, 125 amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 01 No |
| 153 | Outgoing, MCCB 4P, 63 amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 02 No (1No of Spare) |
| 154 | Digital Voltmeter 0-500 Vand Digital Ampmeter0-300A.with selector switich Make-Legrand/Minilac |
| 155 | Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. |
| 156 | Supply, install testing and commissioning in replacement factory madeout door typeLT panel board of size not less than 1mtrX1mtrX0.30 mtr, 440 volts , 3 phase , 4 wire system with powder coating providedto make it dust /vermin proof manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCAsheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 600 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories complete all as specified and directed:- |
| 157 | Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size.(ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size.(iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminumlugs of suitable rating incommensurate with that of switchgear.(iv)Cable glands would be provided for incoming & out going cables in panels.(v)The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item.(vi)The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level. |
| 158 | Aluminium bus bar strips with proper colour code -04 No, 600 A cap, insulator, nuts bolts etc complete. |
| 159 | Indicator Lamp-01 Set (Set of three) |
| 160 | IncommerMCCB 4P250Amp, 415V, 36 KA - 01 NoIcs = 100 Icu Adjustable type - 01 No |
| 161 | Outgoing, MCCB 4P100amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 02 Nos |
| 162 | Outgoing, MCCB 4P63 amp, 415V, 25 KA - 02 NoIcs = 100 Icu Adjustable type (01 No for spare) |
| 163 | Digital Voltmeter 0-500 Vand Digital Ampmeter0-300A.with selector switich Make-Legrand |
| 164 | Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. |
| 165 | Supply, install testing and commissioning factory made indoor type LT panel board wall mounted, self supporting compartmentalised design of suitable size but not less then 1.2 Mtr X 1 Mtr X 0.3 Mtr, 440 V 3 phase 4 wire system powder coating provided with suitable to make it dust/vermin proof Manufactured from CPRI approved Manufacturer. The panel shall be made with 2 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCA sheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs and TPN aluminium bus and extension links. Aluminium bus bar of capacity 200 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be with 2.5 sqmm multi stranded copper conductors and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories complete all as specified and directed:-Location :- (Retreat VIP guest room) |
| 166 | i) Incomer a) MCCB four pole 25 KA rapturing capacity 100 Amps Ics= 100% of Icu thermal magnetic setting including connection with bus bar- 01 Nos(as incomer) |
| 167 | ii) Out going a) MCB SPN 32 Amp 10 KA \"C\" curve-4 Nos (out going )for each Qtrb) MCB SPN 10 Amp 10 KA \"C\" curve-01 Nos (out going )(for staire light and Bldg/S/Light) c) Voltmeter0 to 500voltsof size (square dialed) 96 X 96 sq mm flush mounted, AC 50 Hz three phase energy accuracy class 1.0 including inbuild selector switch - 01 Nosd) Ammeter 0 to 100 amps of size 96 X 96 sq mm flush mounted, AC 50 Hz three phase energy accuracy class 1.0 including inbuild selector switch and suitable ratio of CT\"s complete - 01 Nos e) LED type RYB phase indicator lamp with back up HRC fuse- 01 Set f) Suitable space for fixing 4 No\"s single phase smart energy meter. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail