| 1 | Excavation intrenches not exc 1.5 m wide and not exc 1.5 deep and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | Removing excavated materialn exc. 50m and depositing where directed at a level n exc 1.5mabove the starting point complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick each layer in loose/soft soil complete all as specified and directed. |
| 4 | Approved earth filling under floor spreading, levelling in layer n exc. 25cm thick, incl well raming and watering as required complete all as specified and directed. |
| 5 | M & L PCC (1:2:4) Type B0 (using 12.5 mm graded stone aggregate) as levelling course/mass concrete complete all as specified and directed. |
| 6 | M&L, Cement concrete (1:4:8)type D2 (using 40mm graded stone aggregate) as in fdn, filling and mass concrete complete all as specified and directed. |
| 7 | M&L Hard core of gauge exc 63mm but n.exc.100mm, deposited, spread and levelled in layer n.exc. 15cm thick each layer, watered and rolled/ rammed to a true surface complete all as specified and directed. |
| 8 | Use and waste for formwork to sides of concrete, in foundations, footings,base ofcolumns & plinth beams, etc in flat for rough finshed surfaces of concrete complete all as specified and directed. |
| 9 | Use and waste for Form work to Columns, square/rectangular, rough finish surfaces of concrete complete all as specified and directed. |
| 10 | Use and waste for Formwork to soffits of suspended slab such as roof slab, floor slabs, landing and similar work; not exc 200mm thick complete all as specified and directed. |
| 11 | Use and waste for Formwork to edges of concrete flats, treads, breaks in floors, window cills concrete railings, opening in concrete walls, floor and roofs slab n. exc 20 cm wide and sides of RCC/PCC bands in walls, exc 10cm and n.exc 20cm wide complete all as specified and directed. |
| 12 | Use and waste for formworkto sides and soffits of floor or roof beams, beam haunchings, lintel bands, cantilevers shelves incldng sup-ports, overhangs, etc comlete all as specified and directed. |
| 13 | M&Lfor mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 14 | M&Lfor mild steel TMT bars ,6 mmto 8 mm diaover, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 15 | M&Lfor mild steel TMT bars 5 mmand overuptoand including 10 mm dia, as in stirrups , spacers and binders, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 16 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams , plinth beams , base for coloumnsand mass concreteetc. complete all as specified and directed. |
| 17 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate ) as incoloumns, pillars , piers , posts and struts etc.complete all as specified and directed. |
| 18 | M&L forreinforced cement concrete Design mix M-25 (using 20mm graded stone aggregate) as in Roof beam, lintel band, cantilevers bressummers, lintels over 1.5m spanetc. complete all as specified and directed. |
| 19 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate ) as in slab supported on walls, beams, columns in floor, roof, landing complete all as specified and directed. |
| 20 | M&L for Brick work with sub class `B\" bricks straight or curved on plan exc 6m mean radius, built in CM 1:6. complete all as specified and directed. |
| 21 | M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone surfaces mixed with water proofingcompound finished even and smooth without using extra cementcomplete all as specified and as directed.Note: Water proofing compound shall be measured and paid seperatly under appropiate item of schedule \"A\" |
| 22 | M&L for Rendering 15 mm thick in cement mortar 1: 6 on fair faces of brick work finshed even and smooth without using extra cement complete all as specified and directed. |
| 23 | M&L for Rendering 5 mm thick in cement mortar 1:3 to concrete surface finishedeven and smooth without using extra cement complete all as specified and directed. |
| 24 | Supply onlyliquid water proofing compound complete all as specified and directed. |
| 25 | M&L Machine cut kota stone slab flooring 20-25mm thick over & including 20mm thick cement screed bed in CM 1:6 laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingcomplete all as specified and directed. |
| 26 | M&L for mirror polish to existing kota stone floor complte all as specified and directed. |
| 27 | M&L Machine cut kota stone slab flooring 12-15mm thick on riser of steps, skirting, dado layied and jointed with grey cement slurry mixed with pigment to match the shade of the slab over of including rendering 10mm in CM 1:4 rubbing & polishing complete all as specified and directed. |
| 28 | M&L non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles, over& including screed bed or bedding layer 15 mm thick of cement mortar 1:4 complete all as specified and directed. |
| 29 | M&L forglazed ceramic coloured tiles in vertical surface of size 350mm x 250mm x 7mm/ 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed inwhite or colour cement to match, aid over and including rendering 10 mm thick on fair facesbrick work or concrete surface in cement plaster 1:4 complete all as specified and directed. |
| 30 | S&F 15mm bore tubes medium grade galvanised with all fitting and fixed to walls and ceiling or laid in floor etccomplete all as specified and directed. |
| 31 | S&F20mm bore tubes medium grade galvanised with all fitting and fixed to walls and ceiling or laid in floor etccomplete all as specified and directed. |
| 32 | M&L for Rotational moulded polyethylene water storage tanks 500 ltr capacity(cylindrical vertical with closed top) hoisted and fixed in position with ball walves 20mm PTMT complete (min weight 210 gmscomplete all as specified and directed. |
| 33 | S&F Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe of 20mm bore of brass ferrule complete all as specified and directed |
| 34 | S&F20 mm bore gun metal globe / gate valve withiron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 35 | S&F for viterous china wash down water closet pan (pedestal pattern) or wall mounted white fixing bolts, excluding flushing cistern and flush pipe including Seat cover, connection to drain and to flushing pipe syphonage pipe etc and mild steel chromium plated or aluminised hinges device & CP Jet complete all as specified and directed. |
| 36 | S&F for PVC valveless syphonic action type flushing cistern low level white with inlet ball valve,float end handle handle including bracket complete of capacity 10 litres, complete all as specified and directed. |
| 37 | S&F Vitreous China bowl urinal flat back ofsize 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe(excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed. |
| 38 | S&F Health faucet ( ABS body) mild steel chromium plated suitable for 15mm dia pipe with1.25 metre long flexibleand ABS wall hoock including making connectionand fixing in position complete all as specfied and directed |
| 39 | S&F vitreous china wash hand basin white flat back of size 550mm x 400mm excluding taps waste chain and plug and porcelain stopper but including brackets complete all as specified and directed. |
| 40 | S & F of size 600x450mm bevelled edge mirror of selected quality with alluminium brackets at all sides mounted on 6mm thick commercial ply wood fixed with screws and cup washers. complete all as specified and directed. |
| 41 | S & F in renewal Pillar taps cast copper alloy with capstan head Chromium Plated screwed down, high pressure with lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly nut screwed for iron pipe and fixed complete all as specified and as directed |
| 42 | S&F waste fitting for wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap, 32mm bore complete all as specified and directed. |
| 43 | S&F for Soap dish of CP fixed with PVC rawal plugs and screw, complete all as specified and directed. |
| 44 | S&F Toilet paper holder of brass, chromium plated of stainless steel complete all as specified and directed. |
| 45 | S & F grating doom 100mm dia of Chromium plated (Minimum weight 25gms to Nahani traps ect complete all as specified and as directed. |
| 46 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and directed |
| 47 | S&F PVC connection of 450 mm length dia 15mm complete all as specified and directed. |
| 48 | S & F Bib taps, cast copper alloychromium plated with crutch or butterfly handle (Long body), screwed down, screwed for iron pipe of bore 15mm complete all as specified and directed. |
| 49 | S&F 15mm Angle stop valve of CP brass any colour high pressure screwed for iron pipe or for union fixed complete all as specified and directed. |
| 50 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 51 | S&F 110 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring jointslaid in trenches or in floorscomplete all as specified and directed |
| 52 | S&F 110 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring joints fixed to wall with necessary clampcomplete all as specified and directed |
| 53 | S&F PVC (SWR) bends any radius, 110 mm bore, provided with access doorcomplete all as specified and directed |
| 54 | S&F 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed. |
| 55 | S&F for 110mm dia PVC(SWR) vent cowl, complete all as specified and directed. |
| 56 | S&F 75mm dia out let PVC (SWR) floor trap plain with grating including jointing with solvent cementcomplete all as specified & directed. |
| 57 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed |
| 58 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed |
| 59 | S&F PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed. |
| 60 | S&F pressed steel frame of size 105mmx60mm for doors with one or more rebates including necessary fixing lungs and hinges, lock strike plate,etc complete all as specified and directed |
| 61 | S & F 2nd class hard wood Plain framed, panelled shutter (two panel) with out inter lockingrail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size ofrail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 62 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed. |
| 63 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification complete all as specified and directed. |
| 64 | S&Ffactory made steel ventilatorwith tophung glazed ventilatorincluding projecting type hinges with steel handle and steel peg stay complete witout glazing bar , dovetailed or welded complete all as specified and directed. |
| 65 | S & F Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, 3.00 mm thickcomplete all as specified and directed. |
| 66 | S & F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 67 | S & F Aluminium anodised, barrel tower bolts of extruded section and fixed 200mm size complete all as specified and directed. |
| 68 | S & F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 69 | S & F Butt hinges, medium weight, cold rolled mild steel 100mm fixed toMS frame work and or PVC door frame by welding or screwing as required at site complete all as specified and directed. |
| 70 | S&F Aluminum handles cast type anodised 150mm complete all as specified and directed. |
| 71 | S & F brass CP tubular towel rail20mm dia `D\"type 60cm long between flanges complete all as specified and directed. |
| 72 | S & F floor door stopper aluminium body and tongue, 140 mm size complete all as specified and directed. |
| 73 | Preparation of new steel surfaces over 10cm width or girth and applying 02 coats of synthetic enamel paints over a coat of red oxide complete all as specified and directed. |
| 74 | Preparation of new wood or wood basedsurfaces over 10cm width or girth and applying 02 coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed. |
| 75 | Preparation of new plastered surfaces of walls and applying 03 coats of white wash complete all as specified and directed. |
| 76 | M&L Preparing new surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 77 | Preparation ofnew plastered surfaces of walls and applying two coats of weather proof water based emulsion paint ( Acrylic paint exterior grade) over one coat of primer complete all as specified and directed. |
| 78 | S&F rolled sections as in main and cross beams, hip and jack rafters, purline where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed . |
| 79 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 80 | S&F for flat iron of size 40x6mm thick wind ties fixed to CGI/Galvalume sheets on roof including or necessary drilling, bolting or riveting etc confirming to Fe- 290 grade E-165complete all as specified and directed. |
| 81 | M&L for100 mm thick PCC(1:4:8) type D-2, (using40 mm graded stone aggregate)as in sub base for floor, finished even and rough complete all as specified and directed. |
| 82 | M & L sand filling under floors or in foundations including watering andconsolidation complete all as specified and directed. |
| 83 | S & F Machine pressed precast conctete interlocking paver block any shape and size with grey cement andpigmentconfirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed. |
| 84 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm),including making drainage opening wherever required complete all as specified and directed. |
| 85 | M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) in bed to drain pipe including packing under and hunching against the sides of pipes after they are laid and tested complete for pipe size of 150mm bore complete all as specified and directed. |
| 86 | M&L for 150 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 87 | M&L for providing cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) in surfaces channels drains and benching including form work and finishing fair and smooth using extra cement (forming fair finished channel shall be measured and paid for separately) complete all as specified and directed. |
| 88 | M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone agg) as in cover slabs for man holes and set in CM 1:4 including necessary from work complete all as specified and directed. Note: Reinforcement and form work shall be measured paid separately) |
| 89 | M&L for Cutting into existing manholes for connecting new 150mm diadrains pipe, making good to pipe and rendering, cutting out existing benching for andforming branch channel ( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm graded stone agg) smooth finished, and reforming benching as required complete all as specified and directed. |
| 90 | S&F tube Medium\" grade galvanised with all fitting laid in trenches, of 25 mm dia complete all as specified and directed. |
| 91 | S&F tube Medium\" grade galvanised with all fitting fixed to wall/floor, of 20 mm dia complete all as specified and directed. |
| 92 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes of 25 mm dia complete all as specified and directed. |
| 93 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes of 20 mm dia complete all as specified and directed. |
| 94 | M&L for Cutting of existing GI pipes in position for insertion of new tees, for branch connection of 25 mm dia from bore of pipe existing CI pipe complete all as specified and directed. |
| 95 | Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable(Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 10 Sqmm 2 Core. complete all as specified and directed. |
| 96 | M&L for Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed. |
| 97 | M&L for Bricks old size sub class \"B\" laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed. |
| 98 | S&F tube Light grade galvanised with all fitting laid in trenches,fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed. |
| 99 | M&L, concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxesfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etc complete all as specified and directed. |
| 100 | One light point controlled by one switch. |
| 101 | One Exhaust fan point controlled by one switch. |
| 102 | One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. |
| 103 | One 5 pin multipurpose socket out let 5/6 Amps on the independent board with other switch. |
| 104 | Description all as per item No 99 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire complete all as specified and directed. |
| 105 | S&F switch piano, flush button single pole one way 5 Amp complete all as specified and directed. |
| 106 | S&F socket out let, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed. |
| 107 | S&F switch piano, flush button single pole one way 15 Amp complete all as specified and directed. |
| 108 | S&F socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed. |
| 109 | S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 110 | S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed. |
| 111 | S&F LED \"T\" Type Mirror light fitting09/10 watt , 6500k , luminous efficiency >100lm/watt with provision of fixed in Lamp holder complete all as specified and directed. |
| 112 | S&F LED Lamp 09/10 complete with 5 star rating complete all as specified and directed. |
| 113 | S&F Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500Kfitting ,Efficiency >110 lumen /watt incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion complete all as specified and directed. |
| 114 | M&L, sub main wiringwith four single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade confirming to IS 14930 (Part-I) 2001,(ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSHcopper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. |
| 115 | S&F MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 116 | S&F, MCB SPN 32 Amps, 240 volts \"C\" series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed. |
| 117 | S&F, MCB SP 240 volts, 6to 32 Amps, \"C\" series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. |
| 118 | Supply & fix fresh air fans , 300mm sweep 900 rpm with louvers with plastic body and all other assembly complete all as specified and directed. |
| 119 | S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt with photometric sensor, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqdlength of 1.5 Sqmm PVC multistranded BIS marked, 03/02 core copper conductor for connection from ceiling rose to light fittings incl testing on completion complete all as specified and directed. |