| Sl. No. | Item Description |
| 1 | Taking down carefully Aluminium/ copper point wiring complete for light, fan, 5A/15A switches socket, 2 way points and bell point etc and also taking down boards with screw, holders, fixture and fittings such as switches, ceiling roses, lamp holder ,bulk head fittings, tube light fittings regulators, sockets, light fitting, brackets, etc. any type of electrical fittings etc complete & making good to disturbed area, complete all as specified and directed by Engineer in Charge. |
| 2 | M&L for Concealed Point wiring complete with 1.5 Sq mm single core multi-stranded cables copper conductor PVC insulated and unsheathed cable 1100 volt grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 25mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings switches, sockets outlets, regulators etc complete including provisioning of 1.5 sqmm PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following, complete all as specified and directed by Engineer in Charge. |
| 3 | (a) All as per described in Item No. 2 but, one light point, ceiling fan/Exhaust fan point controlled by one switch 6Amp, one way, complete all as specified and directed by Engineer in Charge. |
| 4 | (b) All as per described in Item No. 2 but, Bell point controlled by one switch 6Amp one way, complete all as specified and directed by Engineer in Charge. |
| 5 | (c) All as per described in Item No. 2 but, one 3 pin Socket 5/6 Amp on the same board, complete all as specified and directed by Engineer in Charge. |
| 6 | (d) All as per described in Item No. 2 but, one 3 pin Socket 5/6 Amp on the independent board, complete all as specified and directed by Engineer in Charge. |
| 7 | All as per described in Item No.2 but point wiring with 2.5 Sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm PVC insulated & unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 Amp multi purpose socket combination point on independent board, complete all as specified and directed by Engineer in Charge. |
| 8 | Dismantling / Taking down existing unserviceable sub main wiring of size 4/6Sqmm from batten / conduit of any sizeremoving the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location, complete all as specified and directed by Engineer in Charge. |
| 9 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable FRLS of size 6 Sqmm single core through concealed rigid non-metallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note:- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 10 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable FRLS of size 4 Sqmm single core through concealed rigid non-metallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 4 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodof thedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note :- Two run of 4 Sqmm copper cable one run of 4 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 11 | S&F in repairs modular switch piano flush type single pole 1 way 6 Amps 230 volts, AC one way, complete all as specified and directed by Engineer in Charge. |
| 12 | S&F in repair modular switch piano type 16 Amps flush button 230 volts AC one way, complete all as specified and directed by Engineer in Charge. |
| 13 | S&F in repair modular socket outlet 6 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and directed by Engineer in Charge. |
| 14 | S&F in repair modular socket outlet 16 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and directed by Engineer in Charge. |
| 15 | S&F in repair modular bell push flush type 230 volts 6Amps,1 module, complete all as specified and directed by Engineer in Charge. |
| 16 | S&F in repair modular fan regulator electronic step type 2 module suitable for 1200/1400 mm sweep ceiling fan, complete all as specified and directed by Engineer in Charge. |
| 17 | S&F in replacement Celling fan 1200 mm sweep 3 blade energy saving 5 star rating including taking down existing un serviceable ceiling fan from the location and setting asidefor fixing/ depositing to MES E/M store yard, complete all as specified and directed by Engineer in Charge. |
| 18 | S&F in replacement exhaust fan, 300/450 mm sweep,steel body, 230 Volts, single phase, with necessary grouting and fixing arrangements and provision of 3 core flexible copper conductor cable of size 1.5sqmm size from ceiling rose to connector of exhaust fan, complete all as specified and directed by Engineer in Charge. |
| 19 | S&F in repairs ceiling rose surface Bakelite 2/3mm terminal 65x50mm, suitable for 230 volts AC supply, complete all as specified and directed by Engineer in Charge. |
| 20 | S&F in repairs call bell, ding dong, 230 volts AC supply, complete all as specified and directed by Engineer in Charge. |
| 21 | S&F of LED bed side light 2 watts grey/metal synthetic incl connection with suitable size copper wire & fixing the fitting on suitable size PVC/ wooden round block on wall, complete all as specified and directed by Engineer in Charge. |
| 22 | S&F in replacement Tube light fittings LED type 1x20 Watt4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 23 | S&F in replacement Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 24 | S&F in repairs LED bulk head luminaire with opal diffuser 10 watts 6000K IP 65 protection incl suitable size PVC/ sunmica wooden board of suitable size &white twin core flexible wire from celling rose to fitting, complete all as specified and directed by Engineer in Charge. |
| 25 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engineer in Charge. |
| 26 | S&F in repairs 12 watt LED bulb with base cap type, complete all as specified and directed by Engineer in Charge. |
| 27 | S&F of LED street light fitting 60 Watt 230 V AC outdoor type 5700 K with high pressure die cast aluminium hosing along with prismatic polycarbonate modular secondary lens optics with IP 66ingress protection . 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance LED street light shall be of Integral type complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete all as specified and directed by Engineer in Charge.Make :- Bajaj Cat part No. ENXT P54L WH CR PC SD or equivalent all as approved by Engineer-in-ChargeNote :-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 28 | S&F LED street light fitting 150 Watt 230 V AC outdoor type 5700 K with high pressure die cast aluminium hosing along with prismatic polycarbonate modular secondary lens optics with IP 66ingress protection . 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance LED street light shall be of Integral type complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete all as specified and directed by Engineer in Charge.Make :- Bajaj Cat part No. ENXT P54L WH CR PC SD or equivalent all as approved by Engineer-in-ChargeNote :-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder,Tools, Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 29 | S&F of Flood light luminaire 250 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection. Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt. The LED flood light shall have power factor more than 0.95 , 50000 L70,CRI>70,CCT 5665K ± 355K, THD <10%,IP 66,IK 07, Operating Temperature -10 degree Celsius to 50 degree Celsius, Beam Angle 70degree, complete all as specified and directed by Engineer in Charge.Bajaj Cat part No. GLATT MT 480L WH PO PC SD or equivalent all as approved by Engineer-in-Charge Note :-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder, Tools, Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 30 | M&L for down rods for ceiling fan, 0.9 m long, GI pipe of suitable size dulythreaded for check nut and holes drilled for spilt pin including mild steel bolts and nuts, double washers and rubber reel bush suitable for ceiling fans of 1200 mm sweep fixed in repairs, complete all as specified and directed by Engineer in Charge. |
| 31 | M&L for Rewinding of ceiling fan/exhaust fan motor of any size after disconnecting from roof without damage shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding, rewinding the same itemswith suitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding along with 2.5/4 MFD capacitor and baking heatingfor achieving the required insulation resistance, re-assembling the motor and testing complete, incl transporting back to siteand fixing fan/exhaust motor to its original place, reconnecting electric cable etc testing and commissioning, complete all as specified and directed by Engineer in Charge. |
| 32 | S&F in repairs Capacitor 2.5 MFD, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F in repairs Capacitor 4 MFD, complete all as specified and directed by Engineer in Charge. |
| 34 | S&F in repairs Sheet metal enclosure factory made of size 20CMx25CMx12.5CM deep box made out of 2mm thick MS sheet with double door with locking arrangement, epoxy powder coated holes drilled for cable entries suitable for accommodating electric energy meter including brick/cement works as per site requirement including flushing the box in wall and making good the disturbed portion of wall/surface, complete all as specified and directed by Engineer in Charge. |
| 35 | S&F in repairs single pole and neutral enclosure, powder coated, with a two pin earth plug and socket complete, 20 Amps, 240V, including provision of one single pole MCB 20 Amps \"C\" curve type including taking down existing unserviceable enclosures, complete all as specified and directed by Engineer in Charge. |
| 36 | S&F in repairs including flushing in wall MCB DB vertical TPN 4 way, 415 volts AC double door type sheet metal phosphatised powder painted with bus bar neutral earth bar and including provision of MCB TPN, FP 100 Amp conforming to IP 43 as incomer, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F in repairs single pole and neutral (SPN) 8 way MCB distribution box double door powder coated sheet metal enclose 240 volts including 200 Amps rated bus bar, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F in repairs single pole and neutral (SPN) 4 way MCB distribution box double door powder coated sheet metal enclose 240 volts including 200 Amps rated bus bar, complete all as specified and directed by Engineer in Charge. |
| 39 | S&F in repairs or replacement of MCCB 160A, 4 pole, 415 volts with breaking capacity of 16 KA, complete all as specified and directed by Engineer in Charge. |
| 40 | S&F in repairs or replacement of MCB SP 240 volts of capacity 6 to 32 Amps \"C\" series, reputing capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 41 | S&F in repairs or replacement of MCB SPN 240 volts of capacity 32/40 Amps \"C\" series, reputing capacity 10 KA , complete all as specified and directed by Engineer in Charge. |
| 42 | Earthing complete with GI earth plates electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate, using GI earth strip 32x6mm connected to earth plate by means of nut ,bolts and washers as directed GI pipe light grade 50mm bore on water pipe from earth chamber to copper edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cost RCC 1:2:4 type B-1 dully reinforced with MS bars 6mm dia @150 cc both ways with 10mm dia MS bar in lifting handle excavation earth work including laying of GI pipe in walls etcall as directed in electrical plateNo 3 ofSSR pt-I, complete all as specified and directed by Engineer in Charge. |
| 43 | S&F in replacement of storage type electric water heaters (vertical geysers) of 50 litres capacity, 5 star rating, 2000 Wattfixed to wall with suitable bolts and nuts duly grouted including re-connecting the electrical and water supply connection including taking down of Geyser and testing, complete all as specified and directed by Engineer in Charge. |
| 44 | S&F in replacement of heating element,240 volt AC ISI marked of 2000 watts Circular/triangular shape rating as required at site including rubber washers, complete all as specified and directed by Engineer in Charge. |
| 45 | Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed by Engineer in Charge. |
| 46 | S&F in replacement of multifunction safety valve i.e.. Pressure release, non return, drain, expansion, vacuum release valve. of size 15mm dia, for geysers of 25/50 liter, screwed with both ends, complete all as specified and directed by Engineer in Charge. |
| 47 | S&F in repairs indicator lamp square/ round/ rectangular type, green/ red, suitable for geysers, 50/35/25 litres capacity, complete all as specified and directed by Engineer in Charge. |
| 48 | M&L for PVC insulated and sheathedflexible multistranded copper conductor cable, 3 core x 4 sqmm size, 1100 volts grade, fixed in repairs, complete all as specified and directed by Engineer in Charge. |
| 49 | S&F in replacement of unserviceable PVC connection, ISI marked, 15 mm dia 600mm long with brass nuts suitable for hot/ cold water supply, complete all as specified and directed by Engineer in Charge. |
| 50 | S&F in replacement of existing unserviceable PVC connection, ISI marked, 15 mm dia 450mm long with brass nuts suitable for hot/ cold water supply, complete all as specified and directed by Engineer in Charge. |
| 51 | S&F for mild steel fastener bolts, nuts and washers, full threaded, dia of neck 05 to 10mm, length not exceeding 100mm, fixed, complete all as specified and directed by Engineer in Charge. |
| 52 | S&F in repairs stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, 15 mm bore, complete all as specified and directed by Engineer in Charge. |
| 53 | Dismantling/taking down and M&L for servicing and repairs of Window/split AC 1.5/2 Ton capacity for servicing complete, cleaning of evaporator coil, condenser, blower, base tray, drain hole, replacement of polypropylene pad, oiling of fan motor, checking of wiring connections, terminals capacitor, relay selector switches, drainage , rubber bushes bearing bushes etc and re-fixing the same in position and testing complete in full load all as directed. Note : Split AC are installed at various floors in AF stn ie Ground floor to 3rd floor. Contractor shall arrange his own arrangement to access the repairs for split units. No tools and plants shall be supplied to the contractor from the department, complete all as specified and directed by Engineer in Charge. |
| 54 | S&F running capacitor 40/45/50/55/60 MFD suitable for 1.5/2.0 Ton capacity of window type AC fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 55 | S&F in replacement fan blade for window/split AC of 1.5/2.0 Ton, ISI Mark or as per existing make and model, complete all as specified and directed by Engineer in Charge. |
| 56 | S&F in repair of blower motor single phase 230 volts, 50 Hz, 0.5 HP, 900 RPM suitable for window type AC of capacity 1.5/2.0 TR fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 57 | S&F condensing coil (copper coil) assembly complete suitable for window type/spilt type AC of capacity 1.5/2.0 TR etc complete and recharging the refrigerant R-22 and testing fixed in replacement, complete all as specified and directed by Engineer in Charge. BIS/ISI approved make or as per existing model. |
| 58 | M&L for cleaning the gas system with anti corrosive solution and recharging the refrigerant R-22/R-134a/R-410/ R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC/split type AC of capacity 1.5/2.0 Ton including installation at site and testing on full load, complete all as specified and directed by Engineer in Charge.BIS/ISI approved make or as per existing model. |
| 59 | M&L for rewinding of blower motor of window type/split type AC 1.5 Ton capacity single phase 1/5HP, 900 RPM with super enamelled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc, complete all as specified and directed by Engineer in Charge. |
| 60 | Taking down/dismentling of old unserviceable defective Rotary compressor of capacity 2/1.5 TR of split type/window AC and replacement in new rotary compressor of cap 2/1.5 TR by soldering/brazing of copper tube and replacement of foundation pads including nut & bolt and washers as required and charging with refrigerant R-22/R-134A/R-410 to its rated capacity and testing of leakage in the system if any and making good, testing on full load after reinstalling the same, complete all as specified and directed by Engineer in Charge. |
| 61 | Taking down unserviceable & S&F thermostat suitable for split/window AC refrigerator any capacity, complete all as specified and directed by Engineer in Charge. |
| 62 | S&F in replacement Oscillation motor with swing blade strip for indoor unit of split AC 1.5/2. TR capacity same specification/ make as per existing one, complete all as specified and directed by Engineer in Charge. |
| 63 | Supply in replacement of copper pipe line of size 1/4\" to 1/2\" for split/window type AC of any capacity, complete all as specified and directed by Engineer in Charge. |
| 64 | Supply in replacement of copper pipe line of size 3/8\" to 5/8\" for split/window type AC of any capacity, complete all as specified and directed by Engineer in Charge. |
| 65 | Taking down unserviceable brass suction valve & supply & fix new brass discharge valve 3/8\" suitable for cassette/ split type, complete all as specified and directed by Engineer in Charge. |
| 66 | Taking down unserviceable brass discharge valve & supply & fix new brass discharge valve 3/8\" suitable for cassette/ split type, complete all as specified and directed by Engineer in Charge. |
| 67 | S&F in replacement of Brass flair nuts 1/2\" to 1/4\" for split/window type AC of any capacity, complete all as specified and directed by Engineer in Charge.BIS/ISI marked or as per existing make and model. |
| 68 | S&F in repairs fan motor for Outdoor unit of same specification as per existing one suitable for split type AC of capacity 1.5 Ton fixed in replacement, complete all as specified and directed by Engineer in Charge.BIS/ISI marked or as per existing make and model. |
| 69 | S&F in repairs indoor blower motor for split type AC as per existing one suitable for split type AC of capacity 1.5 Ton fixed in replacement, complete all as specified and directed by Engineer in Charge.BIS/ISI marked or as per existing make and model. |
| 70 | S&F in replacement of existing unserviceable/burnt with new PCB of invertor type split/window AC of 1.5/2.0 TR of same make by replacement its unsv parts make it fully functional and refixing the same on existing location, complete all as specified and directed by Engineer in Charge. |
| 71 | Attending day to day complaint of detecting the fault in Refrigerator/water cooler/window AC/split/desert cooler/voltage stabilizer/electric supply in all eqpt like loose nut and bolts, leakage of tube, checking electrical connections, charging of refrigerant, fan motor, compressor, fault etc, complete all as specified and directed by Engineer in Charge.Note:- (a)Any defective part which are required to be replaced to make functional ACs shall be measured and paid separately.(b)The contractor must attend to the complaint and rectify the defect within a maximum of two (2) days. If the contractor fails to meet this deadline, a penalty of ₹500 per day per affected unit (split/window 1.5TR or 2.0TR AC, water cooler, or refrigerator) will be recovered from the contractor\"s Running Account Bill (RAR) |
| 72 | S&F in replacement Blower drum assembly complete for split AC 1.5/2.0TR as per existing, complete all as specified and directed by Engineer in Charge.BIS/ISI marked or as per existing make and model. |
| 73 | M&L for complete maintenance and repairs of refrigerator of capacity 165 to 310 ltrs including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring, veg tray, chiller tray, strainer, freezer door and timer etc and testing, complete all as specified and directed by Engineer in Charge.(i)Rates includes servicing of unit for one time and will be considered as one job. (ii)Rates include all necessary replacement spares mentioned in the servicing agreement; it will not be paid separately(iii)Servicing shall be carried out in the presence of Engr-in-Charge or his representative.Necessary service report(complaint slip) is to be signed by the rep. of AGE E/M.(iv)Old spare parts retrieved after replacement will be the property of the cotractor under schedule of credit and shall be removed by the contractor outside at his own cost. \" |
| 74 | Dismantling of defective compressor sealed unit of refrigerator from existing refrigerator by removing suction/ discharge line and providing new approved factory sealedcompressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134/R22/407A including connection suction/ discharge line complete 165 to 310 Ltrs capacity refrigerator. ISI Mark or as per existing make and model, complete all as specified and directed by Engineer in Charge. |
| 75 | S&F of Thermostat switch with defrosting system suitable for refrigerator of capacity 165 to310 Ltrsfixed in repairs, complete all as specified and directed by Engineer in Charge.ISI Mark or as per existing make and model. |
| 76 | Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 R22 or as existing including connection suction/ discharge line 40/80/60Ltrs capacity water cooler, complete all as specified and directed by Engineer in Charge. |
| 77 | Taking down unserviceable starting relay and supply and fix starting relay for water cooler cap 40/80/60/120/150 ltrs, complete all as specified and directed by Engineer in Charge.ISI Mark or as per existing make and model |
| 78 | Taking down unserviceable push cock & supply and fix new push cock 15mm dia of brass chromium plated suitable for water cooler, complete all as specified and directed by Engineer in Charge. |
| 79 | Taking down carefully desert coolers from various buildings and floors (viz. ground floor, first floor, second floor and third floor) at AF Station, for repair and refixing after completion of necessaryrepairs. Note : Contractor shall make his own arrangements to access various floors and to provide tools and plants for taking down and refixing of desert cooler. The rate quoted shall be deemed to include all these arrangements all as required at site, complete all as specified and directed by Engineer in Charge. |
| 80 | Dismantling of unserviceable wood wool pad and providing not less than 2.5 kg adequate dense newwood wool pad 03 Nos supported with suitable size GI wire & bamboo/wood stick for supporting of wool pad inside complete includingfitted with bolts and nuts suitable for existing desert cooler as per sample, complete all as specified and directed by Engineer in Charge. |
| 81 | M&L for Preparation of old painted surface and applying DUCCO paint by spray gun fully matched with its existing colour outside and two coat of black bituminous paint inside the water cooler base/compressor compartment including removal of all dust and all foreign material with the help of sand paper and rubbing with cleaning compound and polishing on painted surface etc, complete all as specified and directed by Engineer in Charge. |
| 82 | Taking out of unserviceable transparent flexible PVC pipe of 15 mm dia and providing new PVCtransperenctflexible pipe of 15 dia , 03 branch minimum length 0.8 mtr long including clamp and of same quality for water circulation pump to air cooler, complete all as specified and directed by Engineer in Charge. |
| 83 | Dismantling of unserviceable submersible water circulation pump assembly and providing of new submersible electric driven single phase 230 volts, 50 hz 20 watt water circulation pump, nut bolts, clamp, of head minimum1.6 Mtrfor desert cooler, complete all as specified and directed by Engineer in Charge. |
| 84 | M&L for rewinding of exhaust fan motor of desert cooler of size / capacity 4500 CFM Exhaust 1/6 HP1250 rpm including replacement of nut bolts, clamps, complete all as specified and directed by Engineer in Charge.Note The cost shal be included taking down and re-fixing in existing location including clamp nut bolts etc |
| 85 | Dismantling of unserviceable fan bladeand providing of new fan blade made out of aluminium casting suitable for existing desert cooler.make and model, complete all as specified and directed by Engineer in Charge. |
| 86 | Taking down unserviceable capacitor 4 MFD and S & F new capacitor 4 MFD, 220 Volts, complete all as specified and directed by Engineer in Charge. |
| 87 | S&F of control piano switch, flush type, 5 Amps suitable for existing desert cooler including taking down the old unserviceable switch, complete all as specified and directed by Engineer in Charge. |
| 88 | S&F of plug top, 3 pin, 5 Amps including taking down the old unserviceable plug top, complete all as specified and directed by Engineer in Charge. |
| 89 | S&F of plug top, 3 pin, 16 Amps including taking down the old unserviceable plug top, complete all as specified and directed by Engineer in Charge. |
| 90 | S&F of water tray of size 95 cm x 75 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray, complete all as specified and directed by Engineer in Charge. |
| 91 | Taking down U/S desert cooler and supply, installation , testing , commissioning of desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep , 1400 RPM motorand suitablecapacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting woodwool including suitable size top and bottom water tray made of 1.00 mm GIsheet 1000 watts speed control electronic regulator , suitbale size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixingaccessories, complete all as specified and directed by Engineer in Charge.Note:- All electrical equipments shall be of ISI Marks |
| 92 | Supply and fill refrigerant gas R-22/32 or existing gas, complete all as specified and directed by Engineer in Charge. |
| 93 | Supply and fill refrigerant gas R-410, complete all as specified and directed by Engineer in Charge. |
| 94 | Supply and fill refrigerant gas R-134A, complete all as specified and directed by Engineer in Charge. |
| 95 | M&L for block GI pipe upto 25mm from solar water heater (Top roof ) to ground floor bldge and cleaning with anti corrosive solution and pipe block rectification will be done in presence of JE (E/M)/AGE E/M, complete all as specified and directed by Engineer in Charge. |
| 96 | M&L in repair and replacement of voltage stabilizer electronic with digital display suitable for single phase voltage working range 130-270 volts 50Hz AC supply with low voltage high voltage cut off & time delay arrangement of capacity 5 KVA, complete all as specified and directed by Engineer in Charge. |
| 97 | S&F in repair Garden light LED type 8 watt 230 volts AC, outdoor type for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driven and lamp alonwith necessary wiring accessories, complete all as specified and directed by Engineer in Charge. |
| 98 | S&F in repair post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driven and lamp alonwith necessary wiring accessories, complete all as specified and directed by Engineer in Charge. |
| 99 | S&F in repair LED luminaire 600X600mm, 35/36 watt, 220V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driven, holder & LED lamp suitable for roof ceiling including connecting up with driven three core flexible copper conductor 1.5 sqmm size, complete all as specified and directed by Engineer in Charge. |
| 100 | S&F in repair round shape 12 watt 220 volts AC recessed type with high effiency PMMA diffuser soft glare free light complete with driven, holder & LED lamp suitable for roof ceiling including connecting up with driven three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engineer in Charge. |