Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | REPAIR TO DESERT COOLERS1. Disconnecting the electrical and water connection of desert cooler and taking down from its position installed at any floor of the building,opening the side panel and remove the unserviceable /dirty replaced with new Wood wool pad /khas khas pad PVC connection 45 cm long and 15 mm dia with PTMT nuts including Front grill PVC washer,PVC distributor three way,PVC elbow,PVC flexible pipe,Capacitor,Water pump including piano switches,regulators,rotary switches,aluminium fan blade,PVC Float Valve,5 amp plug top,Copper cable etc.Scratching out the old paint from inner and outer surface of cooler with sand emery paper complete and cleaning to make the smooth surface for painting,painting the inner surface of body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammertone paint with spary gun machine includingpainting the air direction change grill and fixing the desert cooler and its parts complete as original and at its original place including making water and electrical connection and testing etc complete all as specified and as directed.Note : (i)Any component/part i.e Wood wool pad /khas khas pad PVC connection 45 cm long and 15 mm dia with PTMT nuts including Front grill PVC washer,PVC distributor three way,PVC elbow,PVC flexible pipe,Capacitor,Water pump including piano switches,regulators,rotary switches,aluminium fan blade,PVC Float Valve,5 amp plug top,Copper cable as mentioned below required for theproper functionality of the equipments shall be measured & paid separetely & cost of fixing of the same is included in the quoted rate.(ii) The cost of nut,bolts,screw etc if required are included in this item and nothing shall be paid extra on this account. |
| 2 | -Ditto- all item as per Ser No 1.00 above butWood wool pads (set of three) weight not less than 500 gms superior quality complete all as specified and directed. |
| 3 | -Ditto- all item as per Ser No 1.00 above but PVC connection 45 cm long and 15 mm dia with PTMT nuts complete all as specified and directed. |
| 4 | -Ditto- all item as per Ser No 1.00 above but PVC/GI/MSfront grill complete suitable for desert cooler any make and nay type and size heavy duty having minimum weight 3 kgs made out of GI sheet including fixing plate/patti complete all as specified and directed. |
| 5 | -Ditto- all item as per Ser No 1.00 above but PVC distributor three way superior quality complete all as specified and directed. |
| 6 | -Ditto- all item as per Ser No 1.00 above but PVC elbow superior quality for desert cooler of any capacitycomplete all as specified and directed. |
| 7 | -Ditto- all item as per Ser No 1.00 above but PVC flexible pipe superior quality heavy duty suitable for desert cooler of any capacitycomplete all as specified and directed. |
| 8 | -Ditto- all item as per Ser No 1.00 above butCapacitor 4 mfd/5mfd complete all as specified and directed. |
| 9 | -Ditto- all item as per Ser No 1.00 above butWater pump of desert cooler 230 volts 50 Hz speed not less than 1300 RPM including repair new of nuts & bolts complete all as specified and directed. |
| 10 | -Ditto- all item as per Ser No 1.00 above butAluminium fan blade 21\" dia suitable for desert cooler of any make and any type complete all as specified and directed. |
| 11 | -Ditto- all item as per Ser No 1.00 above but Piano switch flush type 5 Amp 240 Volts single pole one way complete all as specified and directed. |
| 12 | -Ditto- all item as per Ser No 1.00 above butRotary switch with PVC knob single pole to operate cooler 5 Amp 240 volts single phase including testing & commisssioning complete all as specified and directed. |
| 13 | -Ditto- all item as per Ser No 1.00 above butPVCfloat valves high pressure with polythene float and fly nut (PTMT) complete screwed for iron pipe of brass ferrule suitable for 15 mm bore pipe complete all as specified and directed. |
| 14 | -Ditto- all item as per Ser No 1.00 above but 3 pin 5 amp top plug 240 volts single phase complete all as specified and directed. |
| 15 | -Ditto- all item as per Ser No 1.00 above but Copper cable 3 core round of size 23/0.0076,3.00 mtr long including making connection complete all as specified and directed. |
| 16 | -Ditto- all item as per Ser No 1.00 above but Mild Steel body of 22 gauge suitable for cooler 3000/4000 CFM including taking down unseviceable parts complete all as specified. |
| 17 | -Ditto- all item as per Ser No 1.00 above but Taking out the unserviceable fan motor from the desert cooler of any make and type from the Site locations and carry out to local market,dismantling the fan motor complete removing the copper/aluminium burnt winding,cleaning the stator and then rewinding the stator with super enamelled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing providing all high grade material and class \"B\" varnish for insulation including painting the body of fan motor with two coats of synthetic enamel paint,reassembling the complete fan motorand refixing the desert coooler at6 site location as per the direction of Engineer-in-Charge and testing complete all as specified.Note : (i) The cost of material and labour for super enamelled copper winding wire high grade material class\"B\" varnish included in this item and nothing shall be paid extra on this account.(ii) Ball bearing,shaft,gun metal bush if replaced included in this item and nothing shall be paid extra on this account.(iii) The T & P / Vehicle will be arranged by the contractor at his own cost to carry the fan motor for repairing the motor to local market and back and cost f the same is included in this item and nothing shall be paid extra on this account.(iv) If Fan motor is completely burnt,cage structure is rusted corroded not able to use it again after repair shall be replaced with new fan motor & shall be measured and paid separetely under mentioned below item. |
| 18 | -Ditto- all item as per Ser No 1.00 above but Fan motor1/6 HP single phase 230 Volts three speed variable including fan blade,MS legs (Set of four) and rubber pads complete all as specified and directed. |
| 19 | Servicing of AHUs comprising of cleaning inside & outside by vacuum cleaner and chemical (ISI marked) as recommended by OEM, washing/cleaning of filters, oiling/greasing of moving parts of capacity as under :-Note : Existing AHUs shall be serviced onetime on requirement basis as directed during the contract period and each time servicing shall be measured as one Job. CFM of any capacity - 3 Nos |
| 20 | -Ditto- all item as Per Ser No 2.00 above but Supply & Fixing in replacement of Honey Comb 20 cm Thick Pad any size for AHU Unit of any capacity completely replace and removal of old honey comb pad complete all as specified and directed. |
| 21 | REPAIR TO WATER COOLERS4. Taking out the unserviceable compressor (Sealed Unit) from water Cooler 60/120 Ltrscapacity of make : Voltas and replacement the same with new compressor obtained from factory outlet or authorised dealer make : Copeland/Tecumseh/Whirlpool/LG//Voltas including suitable relay,overloas,starting/running capacitor,flushing out the old burnt condensite from the gas system by vaccumisation,cleaning the system by CTC solution,pressure testing of the system,gas charging with R-134a gas upto the desired pressure,testing & Commissioning the water cooler complete all as directed.Note : (i)Any component/part as mentioned below required for theproper functionality of the equipments shall be measured & paid separetely & cost of fixing of the same is included in the quoted rate. |
| 22 | -Ditto- all item as per Ser No 3.00 above but Blower fan motor suitable for water cooler60/120 Ltrs single phase 230 Volts including mounting ring/washer complete all as directed. |
| 23 | -Ditto- all item as per Ser No 3.00 above butFan blade plastic suitable for water cooler60/120 Ltrs single phase 230 Volts including mounting ring/washer complete all as directed. |
| 24 | -Ditto- all item as per Ser No 3.00 above but Stainless steel taps push button type 15 mm dia for water cooler of any capacity suitable for Voltas water cooler complete all as directed. |
| 25 | -Ditto- all item as per Ser No 3.00 above butRelay & overload set suitable for water cooler complete all as directed. |
| 26 | -Ditto- all item as per Ser No 3.00 above butRunning capacitor ofsuitable capacity for 60/120 Ltrs complete all as directed. |
| 27 | -Ditto- all item as per Ser No 3.00 above butThermostate valve complete all as directed. |
| 28 | -Ditto- all item as per Ser No 3.00 above butCondensor for 60/120 ltrs capacity water cooler complete all as directed. |
| 29 | -Ditto- all item as per Ser No 3.00 above but Drain hose pipe not less than 1.5 m length & 30/40 mm dia with clamping arrangementcomplete all as directed. |
| 30 | -Ditto- all item as per Ser No 3.00 above butMaterial & Labour for cutting the base of water cooler of any capacity and fabrication of new base made out from MS sheet 16 SWG and angle iron as per original size and shape including painting the colours with two coats of synthetic enamelled paint of selected shade and colour over a coat of red oxide primer complete all as directed.Note : The quoted rate shall deemed to be inclusive of the cost of any hardware nedeed to fix the item and shall be provided by the contractor when & whenever required. |
| 31 | REPAIR TO REFRIGERATORS Opening & removing the compressor ,condenser coil of the refrigerator of capacity 300/310Ltrs, of any make,cutting the rusty unserviceable lower portion of the body including supply,fabrication and fixing the lower portion made out of MS sheet as per original size and shape ,reassembling the refrigerator ,scratchingout the old paintwith emery paper and making the surface smooth and applying the two coats of synthetic enamelled paint of original shade/colour on full body of refrigerator by using spray gun and applying anti corrosive black paint with spray machine to compressor & condensor coil complete all as directed.Note : (i)Any component/part as mentioned below required for theproper functionality of the equipments shall be measured & paid separetely & cost of fixing of the same is included in the quoted rate. |
| 32 | -Ditto- all item as per Ser No 4.00 above butThermostat switch with knob for any capacity of refrigerator complete all as directed. |
| 33 | -Ditto- all item as per Ser No 4.00 above but Over load protection complete all as directed. |
| 34 | -Ditto- all item as per Ser No 4.00 above but Freezer door complete including door gasket & bracket suitable for 300/310 Ltrs capacity refrigerator complete all as directed. |
| 35 | -Ditto- all item as per Ser No 4.00 above butAluminium freezer shell suitable for300/310 Ltrscapacity refrigerator complete all as directed. |
| 36 | -Ditto- all item as per Ser No 4.00 above but Plastic vegetable tray heavy duty suitable for300/310Ltrscapacity refrigerator complete all as directed. |
| 37 | -Ditto- all item as per Ser No 4.00 above butCondensor coil suitable for 300/310 Ltrs capacity refrigerator complete all as directed. |
| 38 | -Ditto- all item as per Ser No 4.00 above butPCB module 230 Volts,50 Hz C/S suitable for Single/double door refrigerator of any make complete all as directed. |
| 39 | -Ditto- all item as per Ser No 4.00 above but Bimetal 230 Volts,50 Hz C/S suitable for Single/double door refrigerator of any make complete all as directed. |
| 40 | -Ditto- all item as per Ser No 4.00 above butDefrost timer230 Volts,50 Hz C/S suitable for refrigerator of capacity 300/310 Ltrscomplete all as directed. |
| 41 | -Ditto- all item as per Ser No 4.00 above butCooling fan motor 230 Volts,50 Hz C/S suitablefor Single/double door refrigerator of capacity 300/310 Ltrscomplete all as directed. |
| 42 | -Ditto- all item as per Ser No 4.00 above butCompressor (Sealed unit) of refrigerator of capacity300/310Ltrs AC 230 Volts single phase.compressor procured directly from manufacturer or authorised dealer (with two year warantee) including starting relay assembly with overload protector,commissioning & testing on full load of compressor including supply & charging of refrigerant gas in the system and including of replacement of copper filter single capillarycomplete all as directed. |
| 43 | -Ditto- all item as per Ser No 4.00 above butMaterial & Labour for flusing out the condensate from gas system by creating vaccum,leakage testing of the system,injecting CTC solution for demoisturesing the system and charging R-134a gas upto required pressure complete all as approved and directed. |
| 44 | REPAIR TO DEEP FREEZER Material & labour for removing the existing old aluminium sheet of deep freezer of any capacity,removing the existing condenser tube and cleaning the surface with CTC solution and fitting of new copper tube of suitable sizeincluding PUF insulation and covering with new aluminium sheet and making the surface as original one complete all as directed.Note : (i) Cost of PUF insulation & aluminium sheet if required are included in this item nothing shall be paid extra on this account.(ii) Copper tube and gas charging shall be measured and paid separetely under respective item.(iii) Cost of any fittings/accessories shall be measured and paid separetely under relevent sch item. |
| 45 | -Ditto all item asper Ser No 5.00 above but Compressor (Sealed unit) of deep freezer of capacity 210 Ltrs AC 230 Volts single phase.compressor procured directly from manufacturer or authorised dealer (with two year warantee) including starting relay assembly with overload protector,commissioning & testing on full load of compressor including supply & charging of refrigerant gas in the system and including of replacement of copper filter single capillarycomplete all as directed. |
| 46 | Ditto all item asper Ser No 5.00 above but Cooling fan motor of deep freezer of capcity 210 Ltrscomplete all as directed. |
| 47 | REPAIR TO AIR CONDITIONERSTaking down unserviceable compressor 1.5TR capacity fromthe window /split AC of any make andSupply &fixing new compressor 1.5 Ton capacityincluding bushes, grommets, sleeves , washers , mounting rubbers , nuts , bolts , terminalcovers , brazing and clips from existing AC complete all as specifiedand directed.Make : Emerson/LG/Godrej/Tecumseh/kirlosar. |
| 48 | -Ditto all item asper Ser No 6.00 above but Cleaning of complete existing gassystem with CTC, testing of leakage, charging of refrigerant withR-32, R-22,R407,R-290 ( as Per Site reqirement) after rectification of leakage in existing window type/Split type Air Conditioners of 1.5 TR capacities of make and model as per existing complete all as specified and as directed. |
| 49 | -Ditto all item asper Ser No 6.00 above but Taking down of old unserviceable fan motor of any capacity from the window/split type Air Conditioners 1.5 TR capacity and dismantling old and Providing new fan motor of existing gauge and size completeall as specified and as directed. |
| 50 | -Ditto all item asper Ser No 6.00 above but Supply and fixing running capacitor of any capacity suitable for AC 1.5 TRMake : Tibcon/Sharda / Epcos |
| 51 | -Ditto all item asper Ser No 6.00 above but Supply and fixing in replacement Plug and socket DBwith earth plug and 2 pin suitable for AC including one MCB SP 32A Make: Legrand Ct No 607851/schineider/ABB. |
| 52 | -Ditto all item asper Ser No 6.00 above but S & F PCB (Printed Circuit Board) of window/ split type AC of capacity 1.5tonnes with warranty of 1 year complete all as specified and directed by Engr-in -Charge. |
| 53 | -Ditto all item asper Ser No 6.00 above but Replacement of remote of 1.5 Ton capacity window/split AC of any make / type all as specified and directed by Engr in Charge. |
| 54 | -Ditto all item asper Ser No 6.00 above but Taking down existing AC window/split type any capacity, cleaning, washing complete by water spray carefully and refixing the same in position after replacement of filter compelte all as specified and as directed. |
| 55 | Comprehensive preventive & periodical maintenance of Air Conditioning Plant,comprising of scroll type chiller unit and AHU/humidifires etc capacity 11 TR-03 Nosinstalled atRamgarh(Jaisalmer)including servicing of AC Plant by authorized company representativeto check and inspect all air release valves, Gas pipe line, cleaning and setting of sensors, checking of control panels, checking of cooling and heating system, inspection of all type of filters for smooth & trouble free functioning of AC Plant complete all as specified and as directed.Note :- Servicing & maintenance of AC plant shall be carried out through authorized service agency of manufacturer. The contractor shall submit the inspection Reportin this regard before taking plants under servicing etc. Notes aplicable to serial No : 7.00here-in-before :- (i) Job includes maintenance of AC plant of capacity11 TR-03 Nos unit in summer, winter and monsoon season as per the period of contract including periodical checks i.ethree months maintenance requirement as per manufacturer\"s instructions. The job covers daily upkeep of AC plant comprisingof chiller uniti.econdenser, chiller, etc. complete and cleaning of AHUs with electric motor including pan type humidifiers of different KW ratings, complete ducting, fan coil units, cooling tower, hot water generator and its piping network, chilled water piping, condense piping, pump and motors of chilled water and condenser and cooling towers, water supply piping, instruement starter, connected control cabling/wiring including electrical panels with switchgear (except compressor unit) for smooth & efficient performance of AC plant to achieve desired inside conditions throughout the season all as specified & as directed. (ii)Cleaning of installation inside and out side of the Bldg and the costthereof shall deemed to be included in the unit rate quoted against this item. (iii) Contractor shall provide Techanically qualified person for fault attending within 24 hrs. If the AC plant is off load/break down more than 24 hrs, a penalty at the rate of Rs. 5000/- per day shall be levied and deducted from the contractor\"s payment. (iv) Contractor shall maintain temperature of AC plants at 23 ± 2 degree Celcius and RH 50 ± 5%. (v) During entire contract period any defective components/or any other materials which is not specified in Sch \"A\" but required repair/replacement to make plant/ machinery fully functional, the cost of same shall be deemed included in quoted rates and nothing extra shall be paid to the contractor on this account. The transportation and other necessary equipments shall be arranged/brought by the contractor, hence the bidder is advised to visit the site and assess the q+E30uantum of the work to be carried out in the contract and quote their rate accordingly.(vi)Make and model of part to be replaced shall be same as existing at site (vii) Comprehensive /Periodic maintenance means ensuring optimal functioning of AC plant by synchronising all levels at no extra cost. (viii)All above points mentioned in notes for the period of threemonths shall be considered as one Job. (ix) Periodic maintenance shall take place at every four month or as directed by GE/CWE. (x) Each Job shall be measured and paid in three calendar months. (xi) All installations & surrounding area shall be kept neat and clean all the time by the contractor’s workmen and quoted rate shall deemed to include this provision. |
| 56 | Descaling condenser, chiller and hot water circuit of the following unit by company representative using appropriate chemical as per manufacturer\"s instructions, cleaning the copper tubes with brush, including circulation cleaning chemical by submersible pump and removing all foreign material which are settled inside condenser and chiller unit, with & including replacing the gasket, washers and all materials which are required for descaling, complete all as specified and as directed :-AC Plant 03Unit Complete 11 TR |
| 57 | Supply, installation, testing & commissioning in replacement ofLT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T.Location : (Tubewell No : 06 Rajwai Pump house),(Tubewell No : 10 Rajwai Pump house) & (Tubewell No : 11 Rajwai Pump house)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following) :-INCOMER |
| 58 | (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA. -01 No |
| 59 | (b) Digital Voltmeter 0-500 Volt with inbuilt Selector Switch -01 No |
| 60 | (c) Digital ammeter 0-100 Amp with inbuilt Selector Switch -01 No |
| 61 | (d) Indicating Light RED 220V AC-01 No |
| 62 | (e) Indicating Light Yellow220V AC-01 No |
| 63 | (f) Indicating Light Green 220V AC-01 No |
| 64 | (g) Protection MCB 6 Amp SP-03 Nos |
| 65 | (h) CT 100/5A-03 Nos |
| 66 | OUTGOING |
| 67 | (j) Outgoing Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA. |
| 68 | STAR DELTA STARTER 25/30 HP (SUBMERSIBLE PUMPSET) INCLUDING FOLLOWING ACCESSORIES -01 No |
| 69 | (i) Power Contactor 40A TP (Main & Delta) -02 Nos |
| 70 | (ii) Power Contactor 32 Amp (Star)-01 No |
| 71 | (iii) BI Metal Over load Relay 20-33 amp-01 No |
| 72 | (iv) Star delta timer Micon series -01 No |
| 73 | (v) Aux blocks -03 Nos |
| 74 | (vi) Push Button start/stop 220 V -02 Nos |
| 75 | (vii) Auto manual Selector Switch -01 No |
| 76 | (viii) Indicating Light on 220 V-01 No |
| 77 | (ix) Control MCB 6A SP-01 No |
| 78 | (x) Single phase preventor -01 No |
| 79 | (xi) Digital ammeter (0-100A)-01 No |
| 80 | (xii) Amp Meter Selector Switch-01 No |
| 81 | (k) Automatic Phase Sequence Corrector-01 No |
| 82 | (l) CT 100/5A-03 Nos |
| 83 | (m) Danger Plate-01 No |
| 84 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T.Location : (AFH Pump House Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :-INCOMER |
| 85 | (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No |
| 86 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 87 | (c) Digital ammeter 0-100 Amp incl Amp Meter Selector Switch -01 No |
| 88 | (d) Indicating Light RED 220V AC-01 No |
| 89 | (e) Indicating Light Yellow220V AC-01 No |
| 90 | (f) Indicating Light Green 220V AC-01 No |
| 91 | (g) Protection MCB 6 Amp SP-03 Nos |
| 92 | (h) CT 100/5A-03 Nos OUTGOING |
| 93 | (j) Outgoing Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-02 Nos |
| 94 | STAR DELTA STARTER 20 HP (CENTRIFUGAL PUMPSET)INCLUDING FOLLOWING ACCESSORIES - 02 Nos |
| 95 | (i) Power Contactor 25A TP (Main & Delta)-04 Nos |
| 96 | (ii) Power Contactor 22 Amp (Star)-02 Nos |
| 97 | (iii) BI Metal Over load Relay 14-23 Amp-02 Nos |
| 98 | (iv) Star delta timer Micon series -02 Nos |
| 99 | (v) Aux blocks-06 Nos |
| 100 | (vi) Push Button start/stop 220 V-04 Nos |
| 101 | (vii) Auto manual Selector Switch-02 Nos |
| 102 | (viii) Indicating Light on 220 V-02 Nos |
| 103 | (ix) Control MCB 6A SP-02 Nos |
| 104 | (x) Single phase preventor - 02 Nos |
| 105 | (xi) Digital ammeter (0-60A)-02 Nos |
| 106 | (xii) Amp Meter Selector Switch-02 Nos |
| 107 | (k) Automatic Phase Sequence Corrector -02 Nos |
| 108 | (l) CT 63/5A-06 Nos |
| 109 | (m) Danger Plate-01 No |
| 110 | Supply, installation, testing & commissioning in replacement ofLT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 100 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T.Location : (AFH Tubewell Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :- INCOMER |
| 111 | (a) Supply and fix 4 Pole MCCB 63Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-01 No |
| 112 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 113 | (c) Digital ammeter 0-63 Amp incl Amp Meter Selector Switch -01 No |
| 114 | (d) Indicating Light RED 220V AC-01 No |
| 115 | (e) Indicating Light Yellow220V AC-01 No |
| 116 | (f) Indicating Light Green 220V AC-01 No |
| 117 | (g) Protection MCB 6 Amp SP-03 Nos |
| 118 | (h) CT 63/5A-03 Nos |
| 119 | OUTGOING |
| 120 | (j) Outgoing Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA. |
| 121 | STAR DELTA STARTER 20 HP (CENTRIFUGAL PUMPSET) INCLUDING FOLLOWING ACCESSORIES - 01 No |
| 122 | (i) Power Contactor 25A TP (Main & Delta)-02 Nos |
| 123 | (ii) Power Contactor 22 Amp (Star)-01 No |
| 124 | (iii) BI Metal Over load Relay 14-23 Amp-01 No |
| 125 | (iv) Star delta timer Micon series-01 No |
| 126 | (v) Aux blocks-03 Nos |
| 127 | (vi) Push Button start/stop 220 V-02 Nos |
| 128 | (vii) Auto manual Selector Switch-01 No |
| 129 | (viii) Indicating Light on 220 V-01 No |
| 130 | (ix) Control MCB 6A SP-01 No |
| 131 | (x) Single phase preventor -01 No |
| 132 | (xi) Digital ammeter (0-63A)-01 No |
| 133 | (xii) Amp Meter Selector Switch-01 No |
| 134 | (k) Automatic Phase Sequence Corrector-01 No |
| 135 | (l) CT 63/5A-03 Nos |
| 136 | (m) Danger Plate-01 No |
| 137 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T.Location : (WSA P/H & Borwell Panel & 265 P/H & Borewell Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :-INCOMER |
| 138 | (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-01 No |
| 139 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 140 | (c) Digital ammeter 0-100 Amp incl Amp Meter Selector Switch-01 No |
| 141 | (d) Indicating Light RED 220V AC-01 No |
| 142 | (e) Indicating Light Yellow220V AC-01 No |
| 143 | (f) Indicating Light Green 220V AC-01 No |
| 144 | (g) Protection MCB 6 Amp SP-03 Nos |
| 145 | (h) CT 100/5A-03 Nos |
| 146 | OUTGOING |
| 147 | (l) Outgoing Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA - 01 No |
| 148 | (j) Outgoing Supply and fix 4 Pole MCCB 32 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA - 02 Nos |
| 149 | STAR DELTA STARTER 20 HP INCLUDING FOLLOWING ACCESSORIES - 01 No |
| 150 | (i) Power Contactor 25 Amp TP ( Main & Delta)-02 Nos |
| 151 | (ii) Power Contactor 22 Amp TP (Star)-01 No |
| 152 | (iii) BI Metal Over load relay 14-23 A-01 No |
| 153 | (iv) Satr Delta Timer Micon Series-01 No |
| 154 | (v) Aux Blocks-03 Nos |
| 155 | (vi) Push Button Start/Stop 220 Volt-02 Nos |
| 156 | (vii) Auto manual Selector Switch-01 No |
| 157 | (viii) Indicating Light on 220 Volt-01 No |
| 158 | (ix) Control MCB 6 Amp SP-01 No |
| 159 | (x) Single phase Preventor-01 No |
| 160 | (xi) Digital Ammeter (0-60 Amp) -01 No |
| 161 | (xii) Ammeter Selector Switch -01 No |
| 162 | (k) Automatic Phase Sequence Corrector-01 No |
| 163 | (l) CT 63/5A-03 Nos |
| 164 | STAR DELTA STARTER 10 HP INCLUDING FOLLOWING ACCESSORIES - 02 Nos |
| 165 | (i) Power Contactor 18 Amp TP ( Main & Delta)-04 Nos |
| 166 | (ii) Power Contactor 12 Amp TP (Star)-02 Nos |
| 167 | (iii) BI Metal Over load relay 9-15 A-02 Nos |
| 168 | (iv) Satr Delta Timer Micon Series-02 Nos |
| 169 | (v) Aux Blocks-06 Nos |
| 170 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 171 | (vii) Auto manual Selector Switch-02 Nos |
| 172 | (viii) Indicating Light on 220 Volt-06 Nos |
| 173 | (ix) Control MCB 6 Amp SP-02 Nos |
| 174 | (x) Single phase Preventor-02 Nos |
| 175 | (xi) Digital Ammeter (0-40 Amp) |
| 176 | (xii) Ammeter Selector Switch |
| 177 | (m) Automatic Phase Sequence Corrector-02 Nos |
| 178 | (n) CT 32/5A-06 Nos |
| 179 | (o) Danger Plate-01 No |
| 180 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 60 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T. Location : 757 P/H Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :- INCOMER |
| 181 | (a) Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No |
| 182 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 183 | (c) Digital ammeter 0-60 Amp incl Amp Meter Selector Switch -01 No |
| 184 | (d) Indicating Light RED 220V AC-01 No |
| 185 | (e) Indicating Light Yellow220V AC-01 No |
| 186 | (f) Indicating Light Green 220V AC-01 No |
| 187 | (g) Protection MCB 6 Amp SP-03 Nos |
| 188 | (h) CT 40/5A-03 Nos |
| 189 | OUTGOING |
| 190 | (j) Outgoing Supply and fix 4 Pole MCCB 25 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-02 Nos |
| 191 | DOL STARTER 7.5 HP INCL FOLLOWING ACCESSORIES - 02 Nos |
| 192 | (i) Power Contactor 12 Amp TP(Main & Delta)-02 Nos |
| 193 | (ii) Power Contactor 9 Amp TP (Star)-02 Nos |
| 194 | (iii) BI Metal Over load relay 9-15 A-02 Nos |
| 195 | (iv) Star Delta Timer Micon Series -02 Nos |
| 196 | (v) Aux Blocks-04 Nos |
| 197 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 198 | (vii) Auto manual Selector Switch-02 Nos |
| 199 | (viii) Indicating Light on 220 Volt-02 Nos |
| 200 | (ix) Control MCB 6 Amp SP-02 Nos |
| 201 | (x) Single phase Preventor-02 Nos |
| 202 | (xi) Digital Ammeter (0-25 Amp)-02 Nos |
| 203 | (xii) Ammeter Selector Switch -02 Nos |
| 204 | (k) Automatic Phase Sequence Corrector-02 Nos |
| 205 | (l) CT 25/5A-06 Nos |
| 206 | (m) Danger Plate-01 No |
| 207 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T. Location : 3002 P/H & Borewell Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :- INCOMER |
| 208 | (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No |
| 209 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 210 | (c) Digital ammeter 0-100 Amp incl Amp Meter Selector Switch -01 No |
| 211 | (d) Indicating Light RED 220V AC-01 No |
| 212 | (e) Indicating Light Yellow220V AC-01 No |
| 213 | (f) Indicating Light Green 220V AC-01 No |
| 214 | (g) Protection MCB 6 Amp SP-03 Nos |
| 215 | (h) CT 100/5A-03 Nos |
| 216 | OUTGOING |
| 217 | (j) Outgoing Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-01 No |
| 218 | (k) Outgoing Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-02 Nos |
| 219 | STAR DELTA STARTER 20 HP INCL FOLLOWING ACCESSORIES - 01 Nos |
| 220 | (i) Power Contactor 25 Amp TP ( Main & Delta) -02 Nos |
| 221 | (ii) Power Contactor 22 Amp TP (Star)-01 No |
| 222 | (iii) BI Metal Over load relay 14-23 A-01 No |
| 223 | (iv) Satr Delta Timer Micon Series-01 No |
| 224 | (v) Aux Blocks-03 Nos |
| 225 | (vi) Push Button Start/Stop 220 Volt-02 Nos |
| 226 | (vii) Auto manual Selector Switch-01 No |
| 227 | (viii) Indicating Light on 220 Volt-01 No |
| 228 | (ix) Control MCB 6 Amp SP-01 No |
| 229 | (x) Single phase Preventor-01 No |
| 230 | (xi) Digital Ammeter (0-60 Amp)-01 No |
| 231 | (xii) Ammeter Selector Switch -01 No |
| 232 | (l) Automatic Phase Sequence Corrector |
| 233 | (m) CT 63/5A -03 Nos |
| 234 | STAR DELTASTARTER 12.5 HP INCL FOLLOWING ACCESSORIES - 02 Nos |
| 235 | (i) Power Contactor 18 Amp TP (Main & Delta)-04 Nos |
| 236 | (ii) Power Contactor 12 Amp TP (Star)-02 Nos |
| 237 | (iii) BI Metal Over load relay 9-15 A-02 Nos |
| 238 | (iv) Star delta timer Micon series -02 Nos |
| 239 | (v) Aux Blocks-06 Nos |
| 240 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 241 | (vii) Auto manual Selector Switch-02 Nos |
| 242 | (viii) Indicating Light on 220 Volt-02 Nos |
| 243 | (ix) Control MCB 6 Amp SP-02 Nos |
| 244 | (x) Single phase Preventor-02 Nos |
| 245 | (xi) Digital Ammeter (0-40 Amp) -02 Nos |
| 246 | (xii) Ammeter Selector Switch -02 Nos |
| 247 | (n) Automatic Phase Sequence Corrector-02 Nos |
| 248 | (o) CT 40/5A-06 Nos |
| 249 | (p) Danger Plate-01 No |
| 250 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 60 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T. Location : (Technical Pump House-Armoury)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :- INCOMER |
| 251 | (a) Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No |
| 252 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch -01 No |
| 253 | (c) Digital ammeter 0-40 Amp incl Amp Meter Selector Switch -01 No |
| 254 | (f) Indicating Light RED 220V AC-01 No |
| 255 | (g) Indicating Light Yellow220V AC-01 No |
| 256 | (h) Indicating Light Green 220V AC-01 No |
| 257 | (J) Protection MCB 6 Amp SP-03 Nos |
| 258 | (k) CT 63/5A-03 Nos |
| 259 | OUTGOING |
| 260 | (l) Outgoing Supply and fix 4 Pole MCCB 20/25 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -02 Nos |
| 261 | DOL STARTER 5 HP (CENTRIFUGAL PUMPSET) INCL FOLLOWING ACCESSORIES -02 Nos |
| 262 | (i) Power Contactor 12A TP (Main & Delta)-04 Nos |
| 263 | (ii) BI Metal Over load Relay 9-15 Amp-02 Nos |
| 264 | (iii) Aux blocks-06 Nos |
| 265 | (iv) Push Button start/stop 220 V-04 Nos |
| 266 | (v) Auto manual Selector Switch-02 Nos |
| 267 | (vi) Indicating Light on 220 V-02 Nos |
| 268 | (vii) Control MCB 6A SP-02 Nos |
| 269 | (viii) Single phase preventor -04 Nos |
| 270 | (ix) Digital ammeter (0-25A) |
| 271 | (x) Amp Meter Selector Switch |
| 272 | (m) Automatic Phase Sequence Corrector-02 Nos |
| 273 | (n) CT 20/5A-06 Nos |
| 274 | (o) Danger Plate-01 No |
| 275 | Supply, installation, testing & commissioning in replacement ofLT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T. .Location : Chandan LT Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :-INCOMER |
| 276 | (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA - 01 No |
| 277 | (b) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch-01 No |
| 278 | (c) Digital ammeter 0-100 Amp Amp Meter Selector Switch -01 No |
| 279 | (d) Indicating Light RED 220V AC-03 Nos |
| 280 | (e) Indicating Light Yellow220V AC-03 Nos |
| 281 | (f) Indicating Light Green 220V AC-03 Nos |
| 282 | (g) Protection MCB 6 Amp SP-09 Nos |
| 283 | (h) CT 100/5A-03 Nos |
| 284 | OUTGOING |
| 285 | (j) Outgoing Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No |
| 286 | (k) Outgoing Supply and fix 4 Pole MCCB 32 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA - 02 Nos |
| 287 | STAR DELTA STARTER 12.5 HP INCL FOLLOWING ACCESSORIES 01 No |
| 288 | (i) Power Contactor 18 Amp TP ( Main & Delta)--02 Nos |
| 289 | (ii) Power Contactor 12 Amp TP (Star)-01 No |
| 290 | (iii) BI Metal Over load relay 9-15 A-01 No |
| 291 | (iv) Satr Delta Timer Micon Series-01 No |
| 292 | (v) Aux Blocks-03 Nos |
| 293 | (vi) Push Button Start/Stop 220 Volt-02 Nos |
| 294 | (vii) Auto manual Selector Switch-01 No |
| 295 | (viii) Indicating Light on 220 Volt-01 No |
| 296 | (ix) Control MCB 6 Amp SP-01 No |
| 297 | (x) Single phase Preventor-01 No |
| 298 | (xi) Digital Ammeter (0-40 Amp) -01 No |
| 299 | (xii) Ammeter Selector Switch -01 No |
| 300 | (l) Automatic Phase Sequence Corrector-01 No |
| 301 | (m) CT 40/5A-03 Nos |
| 302 | STAR DELTASTARTER 10 HP INCL FOLLOWING ACCESSORIES -02 Nos |
| 303 | (i) Power Contactor 18 Amp TP (Main & Delta)-04 Nos |
| 304 | (ii) Power Contactor 12 Amp TP (Star)-02 Nos |
| 305 | (iii) BI Metal Over load relay 9-15 A-02 Nos |
| 306 | (iv) Star delta timer Micon series -02 Nos |
| 307 | (v) Aux Blocks-06 Nos |
| 308 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 309 | (vii) Auto manual Selector Switch-02 Nos |
| 310 | (viii) Indicating Light on 220 Volt-02 Nos |
| 311 | (ix) Control MCB 6 Amp SP-02 Nos |
| 312 | (x) Single phase Preventor-02 Nos |
| 313 | (xi) Digital Ammeter (0-32 Amp)-06 Nos |
| 314 | (xii) Ammeter Selector Switch -02 Nos |
| 315 | (n) Automatic Phase Sequence Corrector -02 Nos |
| 316 | (o) CT 32/5A-06 Nos |
| 317 | (p) Danger Plate-01 No |
| 318 | Supply, installation, testing & commissioning in replacement ofLT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.0 mm thick CRCA sheetfactory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 1200 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of suitable size with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as directed :-NOTES:[i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T.Location : (SMQ Main Panel)(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item) and consisting of the following :-INCOMER |
| 319 | (a) Supply and fix 4 Pole MCCB 800 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 36 KA-01 No |
| 320 | (b) On load change over Switch 200 Amp 4 Pole -01 No |
| 321 | (c) Outgoing MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-01 No(For Perimeter Lights & AFH Pump House) |
| 322 | (d) MCCB 80 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -01 No(For RO Plant,Lighting Load,Sewage Pumping station No : 05) |
| 323 | (e) MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA -02 Nos(For Water Transfer from UG Sump 3 to UG Sump 2) SMQ P/H |
| 324 | (f) Outgoing Supply and fix 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 36 KA -02 Nos(For 75 HP C/F Pumpset) |
| 325 | (g) Outgoing Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA-02 Nos(For 40 HP C/F Pumpset) |
| 326 | (h) Digital Voltmeter 0-500 Volt incl Voltmeter Selector Switch |
| 327 | (j) Digital ammeter 0-100 Amp inclAmp Meter Selector Switch |
| 328 | (k) Indicating Light RED 220V AC-01 No |
| 329 | (l) Indicating Light Yellow220V AC-01 No |
| 330 | (m) Indicating Light Green 220V AC-01 No |
| 331 | (n) Protection MCB 6 Amp SP -03 Nos |
| 332 | (o) CT 800/5A-03 Nos |
| 333 | STAR DELTA STARTER 75 HPINCLUDING FOLLOWING ACCESSORIES -02 Nos |
| 334 | (i) Power Contactor 95 Amp TP ( Main & Delta)-04 Nos |
| 335 | (ii) Power Contactor 80 amp TP (Star)-02 Nos |
| 336 | (iii) BI Metal Over load relay 66-100 A-02 Nos |
| 337 | (iv) Satr Delta Timer Micon Series-02 Nos |
| 338 | (v) Aux Blocks-06 Nos |
| 339 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 340 | (vii) Auto manual Selector Switch-02 Nos |
| 341 | (viii) Indicating Light on 220 Volt-02 Nos |
| 342 | (ix) Control MCB 6 Amp SP-02 Nos |
| 343 | (x) Single phase Preventor-02 Nos |
| 344 | (xi) Digital Ammeter (0-250 Amp) -02 Nos |
| 345 | (xii) Ammeter Selector Switch -02 Nos |
| 346 | (p) Automatic Phase Sequence Corrector-02 Nos |
| 347 | (q) CT 250/5A-06 Nos |
| 348 | STAR DELTA STARTER 40 HPINCLUDING FOLLOWING ACCESSORIES - 02 Nos |
| 349 | (i) Power Contactor 50 Amp TP ( Main & Delta) -04 Nos |
| 350 | (ii) Power Contactor 40 Amp TP (Star)-02 Nos |
| 351 | (iii) BI Metal Over load relay 24-40 A-02 Nos |
| 352 | (iv) Satr Delta Timer Micon Series-02 Nos |
| 353 | (v) Aux Blocks-06 Nos |
| 354 | (vi) Push Button Start/Stop 220 Volt-04 Nos |
| 355 | (vii) Auto manual Selector Switch-02 Nos |
| 356 | (viii) Indicating Light on 220 Volt-02 Nos |
| 357 | (ix) Control MCB 6 Amp SP-02 Nos |
| 358 | (x) Single phase Preventor-02 Nos |
| 359 | (xi) Digital Ammeter (0-150 Amp) -02 Nos |
| 360 | (xii) Ammeter Selector Switch -02 Nos |
| 361 | (r) Automatic Phase Sequence Corrector-02 Nos |
| 362 | (s) CT 150/5A-06 Nos |
| 363 | (t) Danger Plate-01 No |
| 364 | Earthing completewith galvanized steel earth electrode of size 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of the plate not less 1.5 metre below normal ground level connecting to galvanized earth lead of size 32x6 mm GI strip by means of bolts, nuts, check nuts and GI washers etc. earth plate shall be surrounded by packed layers of coal dust and common salt 30 cm thick all around bottom and top and watering pipe 20 mm dia light grade including earth chamber of using sub class \"B\" bricks in CM 1:4, 12mm thick cement plaster in CM 1:4 and angle iron frame 40x40x6mm and MS plate cover 6mm thick with locking arrangement all as shown on drg. Earthing strip shall be protected by 40 mm dia GI light grade pipe upto a distance not exc 3m from top of earthing pit . The earth strip shall be tested after carefully completion as per IS specifications and as shown in electric plate No 3 of SSR Part-I of 2009 and testing on completion complete all as specified and as directed. |
| 365 | Supply & Pouring Calcium hypochlorite garnules(65% to 70 %)calcium based disinfection chemical (must contain corrosion inhibitor & anti scaling agent and possess self life of chemical to minimum of one year with minimal loss of chlorine complete all as specified and directed by Engineer-in-charge.Note : Test certificate of each lot shall be submitted by the contractor to AGE E/M (AF) Jaisalmer. |
| 366 | Supply & Pouring Sodium hypochlorite solution (Liquid state) with chlorine content 10-14 % complete all as specified and directed by Engineer-in-charge.Note : Test certificate of each lot shall be submitted by the contractor to AGE E/M (AF) Jaisalmer. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail