| 1 | Sch \"A\" |
| 2 | M&L for painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete under satisfaction of Engr-in-Chargecomplete all as specified and specified. |
| 3 | M&L for taking down ceiling fan for repair of any make/modelof sweep 1200/1400 mm by removing burnt/heated winding from stator and rewinding the stator coils with super enameled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer and two core flexiblewire of size 0.50 sqmm with copper conductor of suitableupto 1.50 m lengthfrom fan terminal to ceiling rose including replacement of gun metal bush, bearing setand capacitor &refiixing the same after repair complete all as specified and directed. |
| 4 | M&L for taking out exhaust fan for repair of any make/ modelof sweep 250 mm to 300 mmby removing burnt / heated winding from stator and rewinding the stator coils with super enameled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of shaft and bearing of suitable size (ISI marked), mounting lugs and two core flexiblewire of size 0.50 sqmm with copper conductor of suitableupto 1.50 m length from fan terminal to ceiling rose gun metal bush, bearing set and capacitor & refiixing the same after repair complete under satisfaction of Engr-in-Chargecomplete all as specified and directed. |
| 5 | All as per item No. 3 above but exhaust fan 380 mm to 450 mm sweep size complete all as specified and directed.. |
| 6 | M&L fortaking down ceiling fan of any make and model having sweep 1200mm/1400mm fixed in buildings at various locations for minor repair as opening fan rotor, cleaning with kerosine oil, greasing and re-fixing in existing location including replacement of cotter pin/ split pins, capacitor, canopies,refixing the sameafter repair complete all as specified and directed. |
| 7 | M&L for taking down exhaust fan having sweep 250 mm to 450 mmfixed in buildings at various locations for minor repair as opening fan rotor, cleaning with kerosine oil, greasing and re-fixing in existing location including replacement of mounitng legs, louvring shutter, capacitor,ball bearing, gun metal bush, rubber vibrating pads& refixing the sameafter repair complete all as specified and directed. |
| 8 | Supply and replacement offan capacitor3.15 mfd complete all as specified and directed. |
| 9 | Supply and replacement of fan capacitor 4.0 mfd complete all as specified and directed. |
| 10 | S&F inreplacement of set of blades for ceiling fan 1200/1400mm sweep duly screwed with spring washers of make as per existing one complete all as specified and directed. |
| 11 | S&F in replacement oflight grade down rod for ceiling fan size 60 cm length with connected nut bolt washer complete all as specified and directed. |
| 12 | S&F louvershutter iron body of superior qualityfor exhaust fan any size any typecomplete all as specified and directed. |
| 13 | S&F in replacementof electronicfan regulator 230 volts suitable for ceiling fan of size 1200mm/1400mmsweep complete all as specified and directed. |
| 14 | S&F Exhaust Fanblade made out of metal , sweep size 250-450 mm duly screwed with spring washers of make as per existing including taking down and refixng complete all as specified and directed. |
| 15 | S&F in repalacement of High Air Delivery 490 CMH, Speed:-1350 RPMPVC Exhaust Fan Motor 35 watt , 220 Volt single phase sweep size200 to 300 mm complete all as specified and directed. |
| 16 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep.including remote control with cell Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor ( BLDC) all including connection with three core 1.5 sqmm PVC insulated but unsheathed FRLS cable with multistranded copper conductorsfrom celing rose to fan complete all as specified and directed. |
| 17 | Taking down carefully window / Split Air Conditoner unitcapacity of 1.5/2.0 Ton from the fixtures, disconnecting power cables, drain pipes & accessories and cleaningby removing dust with suitable pressure system, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor & blower motorby greasing incl minor repairs, required welding orbrazing to prevent leakages of gas, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of tharmocol,Brass nut, flair nuts, backelite connector andrefixing the AC unit and connecting up complete after carrying out necessary repair/servicing to the entire satisfaction of the engineer in charge. Note :1. Spare parts will be measured and paid under relevent item ofschedule |
| 18 | M&L for rechargingR-22/R-32/R-410 gas as requiredor as per manufacurer recommendations in air conditioners split or window type 1.5 Ton &2 Ton capacity any make or modelincluding testingand prevention of leakage for satisfactory performance complete all as specified and directed. |
| 19 | M&L for replacement of compressor sealed unit suitable for Air conditioner splittype as per existing make or modelof capacity 1.5/2.0 TR in outdoor unit including taking out to old us compressor and cleaning flushing, vaccumizing the system, recharging of gas in adequate quantity, soldering/ brazing of suction- discharge line complete all as specified.Note : (i) Necessary testing shall be carried out in presence of Engr-in-Charge or rep concern.(ii) Cost of minor spares require to make thefunctional shall deemed to beincluded in quoted rate. |
| 20 | S&Fin replacement blower motor Single Shaft, suitable for Split type AC 1.5 or 2 Ton single ended or double ended shaft as per existing make or model complete all as specified and directed. |
| 21 | S&F in replacement Out door fan motor with aluminium blades suitable forSplit type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing make or model complete all as specified and directed. |
| 22 | M&L for Shifting ofSplittype Air conditionerany make or model capacity of 1.5 /02 Ton with necessary modification including electrification complete all as specified and directed. |
| 23 | Dismantlingand repalcement ofEvoporator coilof 1.5/2 Ton capacity window type/split type Air Conditioner made up of copper tubing and aluminium cooling fins including brazing, welding etc., replacement of copper/aluminum tubing/fins as per existing with new one as per site requirement, refixing in original position and testing etc complete all as specified and directed. |
| 24 | M&L for taking out damgedindoor unit of split type air conditioner capacity of 1.5 ton and fixing in repalcement ofremote control operated unit having maximum air flow 750 cum/hr, noise level 46 dB Max in dimesion of 906 x 235 x 286 mm in duel layer of copper coil & net gross weight 12.5 kg complete all as specified and directed. |
| 25 | Dismantlingand repalcement ofcondensorcoilof 1.5/2 Ton capacity window type/split type Air Conditioner made up of copper tubing and aluminium cooling fins including brazing, welding etc , replacement of copper/aluminum tubing/fins as per existing with new one as per site requirement, refixing in original position and testingetc complete all as specified and directed. |
| 26 | S&F in replacement starting capacitor& running capacitor as per exising rating (ISI marked)for 1.5 Ton/2.0 Ton capacity split or window air conditioner complete all as specified and directed. |
| 27 | S&F in replacement over load protector suitable for 1.5 /2 Ton A/Ccomplete all as specified and directed. |
| 28 | S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity AC complete all as specified and directed. |
| 29 | S&F in replacement of thermostat suitable for Split 1.5 / 2 Ton capacity AC complete all as specified and directed. |
| 30 | Supply and fix in replacement of Electronic Power Control Box \"LED Display\" with portable Remote for Split Type type AC 1.5/2 Ton complete all as specified and directed. |
| 31 | M&L inreplacement of copper tube of size 1/2\", 1/4\",3/8\", 5/8\" with duly nylon insulation including necessary brazing /welding, flair nutbolt etc, complete all as specified and directed. |
| 32 | S&Fin replacement of Voltage stabilizer 4 KVA Copper Wound suitable for Split type AC 1.5 TR including installation complete all as specified and directed. |
| 33 | S&Fin replacement of Voltage stabilizer 5 KVA Copper Wound suitable for Split type AC 1.5 TR including installation complete all as specified and directed. |
| 34 | S&F Drain PVC pipe, 15/20 mm bore as per site requirement3.5 M in length with two Nos mild steel clamps necessary brass screws as in replacement complete all as specified and directed. |
| 35 | Supply and fix exhaust fan made of sturdy Engineering Plasticbody complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including necessary connectionof flexible copper cable from ceiling rose to exhaust fan complete all as specified and directed. |
| 36 | M&L opening of deep freezer of capacity 300 to 420litre from any position for repairs, removing unserviceable compressor and supply and replacement of new compressor as per existing make or model duly charged with compressor oil and charged with gas including brazingin position and testing at required pressure complete all as specified and directed.Note : (i) Necessary testing shall be carried out in presence of Engr-in-Charge or rep concern.(ii) Cost of minor spares require to make thefunctional shall deemed to beincluded in quoted rate. |
| 37 | M&L opening up deep freezer 300 to 420 litre capacity and refrigerator 165 to 420 litres,flushing out and removal of blockage, brazing etc. including replacement of liquid line filter, recharging the deep freezer/ refrigerator with R-134/R22 or as per manufacturer recommendations gas to obtain desired cooling and re-fixing in original position complete all specified and directed. |
| 38 | Taking down unserviceable fan motor of deep freezer/r̥efrigerator and rewinding with super enameled copper winding wire of suitable size including replacement of bushes, rubber, mounting clips etc. including commissioning & testing complete all as specified and directed. |
| 39 | M&L for removing of defective compressor sealed unit from Refrigerator 165 to 300 Ltrs, cutting and supply and fixing new compressor of same capacity as per existing make or model, installing with existing system by brazing etc. Flushing of complete system with nitrogen gas to detect any leakage if any including charging of refrigerent approvedor as per recommendation of manufacturer to its full capacity including connecting and testing complete all as specified and directed.Note - Cost of minor spares require to make thefunctional shall deemed to beincluded in quoted rate. |
| 40 | All as per item No. 38 here-in-before but refrigeratorcapacity 300 to 420litres complete all as specified and directed. |
| 41 | S&F in replacement of freezer door (plastic) forRefrigerator/deep freezercomplete with tension spring as per existing one complete all as specified and directed. |
| 42 | S&F in replacement of starting capacitor& running capacitor of deep freezer/Refrigertor as per Existing rating complete all as specified and directed. |
| 43 | Supply and fix in replacement of Electronic Power Control Boxfor refrigerator/deep freezer or water coolercomplete all as specified and directed. |
| 44 | M&L in replacement of Thermostat switch with knob for Refrigerator/deep freezeras in replacement complete all as specified and directed. |
| 45 | M&L for Starting relay suitable for compressor of Refrigerator/deep freezerof any capacity as in replacement complete all as specified and directed. |
| 46 | M&L for repairs tovoltage stabilizer capacity upto 5 KVA single phaseof any make with input voltage 70-190volts and output voltage 200-240 volt by dismantling and taking out and replacement ofAmeter, voltmeter, voltage thermal relay, time relay alongwith insulation material and re-fixing the same complete all as specified and directed. |
| 47 | S&Fin replacement of Evaporator assembly with screw, jointing of tubes etc and testing of capacity 165 to 410 LtrsRefrigerator/deep freezer complete all as specified and directed. |
| 48 | M&L for checking out of Water coolercapacity of 40/60/150 ltrs of any makeat anylocation and positionincludingnecessary servicing comprising of cleaning storage tank, check electric connection, refxing drain out tray and pipe with nut bolt & clamp, replacement PVC float valve 15 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, greasing offan motor, cleaning of condensor unit by vaccum pressure,checkleakage in the storage water tank of water cooler and making good by soldering/brazing to prevent leakage spots,testing for proper functioning in preset of complete all as specified and directed. |
| 49 | M&L for removing of defective compressor sealed unit for water cooler ofstorage capacity40/80 Ltr per hours, fixing new compressor as per existing make or model, sealed unit complete of same capacity including installing with existing system by brazing etc. Flushing of complete system with CO2 gas to detect any leakage if any, including charging of refrigent approved R22/134A or as per recommendation of manufacturer to its full capacity including connecting and testing complete all as specified and directed.Note-(i) Cost of minor spares required to make the water cooler functional shall deemed to beincluded in quoted rate. (ii) Necessary testing shall be made in presence of Engr-in-Charge as directed. |
| 50 | All as per item No. 48 here-in-before but water coolercapacity 60/120 litres complete all as specified and directed. |
| 51 | M&L fortaking down unserviceable fan motor of water cooler of any capacity and rewinding with super enamelled copper winding wire of suitable size including replacement of bushes, rubber, mounting clips etc. including commissioning & testing complete all as specified and directed. |
| 52 | S&F in replacement of Thermostat switch with knob for water cooler, having cooling capacity 40 ltr to 150 ltr per hour as in replacement complete all as specified and directed. |
| 53 | S&F in replacement of Drain PVC pipe, 25/32 mm bore 1.00 metrein length with two Nos mild steel clamps necessary brass screws as in replacement and complete all as specified and directed. |
| 54 | S&F ofDrain water tray of water cooleras per existing size made out ofstainless Steel sheetwith necessary GI screws andconnect with PVC drain water complete all as specified and directed. |
| 55 | S&F CP push cock ,15 mm bore made outof brass chromium plated self closing horizontal type with CP adaptor and nipple complete as in replacement complete all as specified and directed. |
| 56 | S&F in replacement of starting capacitor & running capacitorfor water cooler as per exisitng rating(ISI marked) complete all as specified and directed. |
| 57 | M&L for Aluminium fan blade for suitable for water cooler having cooling capacity 40 to 150 litre/houras in replacement complete all as specified and directed. |
| 58 | M&L for opening of water cooler of 40/80 ltr/hr, 60/120 ltr/hr, 150/150 ltr/hr capacity, flushing out and removal of blockage through copper filter and capillary tube, tracing out of leakageincluding gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed , replacement of liquid line filter and recharging the water cooler with R-22/ R-134 gas or as per manufacturerto obtain desired cooling complete all as specified and directed. |
| 59 | Taking out and refixingafter repairs includingrewinding of Desert Cooler fan motor of any make & capacity with super enameled copper windingwire of appropriate size including replacement of bush, ball bearing (ISI marked), rotor shaft and repair of body of desert cooler, refixing after testing,complete all as specified and directed. |
| 60 | Material and labour taking down desert cooler fixed in any position, cleaning internally and externally by scraping all scales dirt etc, carrying out repairs to check leakage, replacing screws, nuts and bolts etc. and painting the same with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer using spray gunwriting of \"\"MES Number /MES Ludhiana \"\" etc ,refixing of the desert cooler in existing position after necessary oilling and greasing of fan motor including replacement of high density polythylene pipe 15mm with fittings complete all as specified and directed. |
| 61 | Supply and fixing in replacementof heavy duty copper woundhigh speed desert cooler motor 300 watt, 230 Volt single phase, 1500 rpm incl mounting lugs and clamp as reqd. complete all as specified and directed. |
| 62 | M&L for replacement of bearing for desertcooler fan motor as per existing sample complete all as specified and directed. |
| 63 | M&L in replacement of Front grill ( horizontal and vertical members moveable) of the Desert Cooler made out of 24 gauge PGI sheet complete all as specified and directed. |
| 64 | S&F desert coolerbottom panel made out of Existing gauge PGI Sheet with suitable water level indicator including painting to match with the existing desert cooler body as in replacement complete all as specified and directed. |
| 65 | S&Fthree way rotary switch having 3 speed – Slow Speed, Medium Speed ,Fast Speed and Forth Option to Switch it offfor desert cooler complete all as specified and directed. |
| 66 | S&F Woodwoolpad for Desert Cooler of Sutable size(set of three pads) as per existing, superior quality covering with 3 Iron Meshesincluding binding properly with GI wire with grill as in replacement complete all as specified and directed. Note:- Disposal for the old waste material shall be responsibility to contractor without any extra cost. |
| 67 | Supply and replacement of water lifting pump submersible type, 18 Watts, 230 volt, 50 C/S, single phase suitable for desert coolers including fixing of pvc pipe with bend elbow etc as required complete all as specified and directed. |
| 68 | M&L for taking down wall mounted fan for repair of any make/ modelof sweep upto 450 mm by removing burnt / heated winding and rewinding with super enameled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer, bearing, bush, and two core flexiblewire of size 1.5 sq mm with copper conductor of suitableupto 1.50 m length& refiixing the same after repair complete all as specified and directed. |
| 69 | M&L for fixing of commercial plywood 4mm thick in window for covering of desert cooler with fixing arrangment complete all as specified and directed. |
| 70 | S&F in replacement ofMCB Protected Socket PVC (Plastic) withBase boxfor AC connection withMCB SP 20 Amps complete all as specified and directed. |
| 71 | Supplyand fixing of solar flat platecollector type with heat exchanger of500 ltrs per day capacity and size of collector 2112 X1035 X 101mm including necessary fittings complete all as specified and directed. |
| 72 | S&F for switch pianotype, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed. |
| 73 | S& F inreplacement of 16 Amp, 3 Pin Plug top complete all as specified and directed. |
| 74 | S& F inreplacement of5 Amp, 3 Pin Plug top complete all as specified and directed. |
| 75 | M&L for opening electric geyser of capacity 25/35 litre, taking out the inner tank, glass wool, geyser assembly, heating element and thermostat etc., cleaning, paintingthe complete geyser using iron brush/ iron rod and taking out the dirt & other deposits, re-assembling the geyser after replacing the defective parts and refilling the glass wool etc including taking down existing geyser after disconnecting water supply and electric connection and re-connecting the same after repairs complete all as specified and directed. Note :- Replacement of geyser parts and connected items as required shall be measured and paid for separately under appropriate item of this Schedule. |
| 76 | S&F in replacement of heating element single phase 230 volts with rubber gasket; push type round/triangular shape of capacity 2 KW complete all as specified and directed. |
| 77 | S&F in replacement of thermostat single phase 230 volts with setting range 0° C to 85° C complete all as specified and directed. |
| 78 | S&F in replacement of geyser assembly having copper base and piping with 9/8/6 holescomplete all as specified and directed. |
| 79 | S&F in replacement of worn out/ leaking inner steel body water tank for 25 litre capacity geyser complete all as specified and directed. |
| 80 | S&F in replacement of base platewith indicator lamp(Red and green) in two parts of size complete all as specified and directed. |
| 81 | S&F in replacement of air/pressure release valve complete all as specified and directed. |
| 82 | Supply and filling in glass wool 50 mm thickfor packing between inner & outer geyser assembly complete all as specified and directed. |
| 83 | S&F in replacement of old/ rusted and worn out geyser outer cover for 25 litre capacity geyser complete all as specified and directed. |
| 84 | S&F in replacement ofwired PVC connection pipe heavy quality , ISI markedfor geyser size of 15 mm bore with brass nuts and washer,length of 600 mm complete all as specified and directed. |
| 85 | S&F in replacement stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for unions suitable for size 15mm bore complete all as specified and directed. |
| 86 | S&Ffor HOT Water pipe 20mm diadulyinsulated with glass wool/mineral andaluminium claddingISI markedincluding fixing clamps, screws etc .screwed and socket joints including all fitting such as bends,elbow, tees,short pieces, plug,union, sockets and fixing materialhocks clips etc fixed along wall/roof/OR in trenches etc complete all as specified and directed. |
| 87 | S&Ffor HOT Water pipe 15 mm diadulyinsulated with glass wool/mineral andaluminium claddingISI markedincluding fixing clamps, screws etc .screwed and socket joints including all fitting such as bends,elbow, tees,short pieces, plug,union, sockets and fixing materialhocks clips etc fixed along wall/roof/OR in trenches etc complete all as specified and directed. |
| 88 | M&L in replacementfor galvanised steel tubing 15mm dia medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling/roof etc complete all as specified and directed . |
| 89 | M&L in replacementfor galvanised steel tubing 20 mm dia medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling/roof etc complete all as specified and directed. |
| 90 | S&F for non return valve( NRV)GM alloy screwedof size 15 mm bore complete all as specified and directed. |
| 91 | S& Ffor\" L\"hook fastener size 10 mm dia and 10 cm long with connected washers fixing on wall for hanging of geyser complete all as specified and directed. |
| 92 | Taking down geyser from the existing postion and refixing thereafter alongwith necessary plumbing and electricfitting with fixture complete all as specified and directed.Note:- rates of spare shall be included in quoted rates |
| 93 | Taking down Solar water heater of capacity 100 ltrs/200 ltrs/500 ltrsand repair /maint of unserviceable items and re-fixed in original position (Spare\"s shall be measured and paid separately under respective item of schedule) complete all as specified and directed.Note :- Servicing/Cleaning of steel tank of solar water heater shall be included in quoted rates. |
| 94 | Supply and fixing in replacement of solar evacuated tube of solar water heatersuitable for 100/200/300/ 500 LPD ,complete with washer etc complete all as specified and directed. |
| 95 | Supply and fixingin replacement of heating element INCOLOY type upto 5 KWfor solar water heater as per sample ISI Marked with rubber gasket of suitable Size complete all as specified and directed. |
| 96 | S&F in replacement of thermostat ISI marked suitable for solar heatercomplete all as specified and directed. |
| 97 | Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 500 ltrs pre insulated hot water storage tank with stand (inner tankSS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank ; complete all as specified and directed. |
| 98 | M&L for taking down andreplacement ofgun metal globe valve size 15 mm inlcudingall as specifed and as directed |
| 99 | M&L for taking down andreplacement gun metal globe valve size 20 mm complete all as specified and directed. |
| 100 | S&F in replacement bib tap cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule15mm bore complete all as specified and directed. |
| 101 | S&F for switch pianotype (PT), 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed. |
| 102 | M&L for Socket outlet multi purpose 2 in 1, 6 pin, 5 & 15 Amps, flush type complete all as specified and directed. |
| 103 | S&F forPVC insulatedFRLS multistranded copper wire suitable for1100 volts grade of size 1.5sqmm, 3 core complete all as specified and directed. |
| 104 | S&F forPVC insulated & unsheathed multistranded copper conductor cable suitable for1100 volts grade of size 2.5 sqmm3 core flexible pvc conduitwith holding clip complete all as specified and directed. |
| 105 | Material and Labour for Brazing / welding of innertank at leaking spots up to five leakage of geyser of capacity 25/35/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washerscomplete all as specified and directed. |
| 106 | Supply and fixingin replacement of brass chormium plated angle valve, fancy typeof size 15mm dia screwed down for high pressure complete all as specified and directed. |