Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for dismantling and removing the air blower machine upto Cap 200 M3/Hr from the existing position and transporting to repair workshop complete, opening the blower, servicing including cleaning & replacement of worn outparts i.e injection ring, distance bush & ring ,sleeve,O-ring,lock nut & washer, ball bearings etc. and installing back to the original position, testing and commissioning on full load for 4 hrs continous running for the capacity of blower to make air blower functional complete all as specified and directed.Note:- All minor consumables incl T&P and Tpt required shall be deemed as included in the rates quoted. |
| 2 | Supply only Pressure gauge (Air) 60 to 180 M3/Hrs complete all as specified and directed. |
| 3 | Supply oly Lube oil for Air compressor (air blower) Servo 320 complete all as specified and directed. |
| 4 | Supply only V belt for 20 HP air compressor complete all as specified and directed. |
| 5 | M&L for dismantling and removing the motor of the centrifugal/ mono block / coupled Pump set or Air compressor from existing position, Shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor/ stator, re-winding the motor with super enameled copper wire of suitable size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning on full load for 4 Hrs continuous running for the capacity of motor upto 3HP complete all as specified and directed. |
| 6 | All as per Srl item No 5 here-in-before but more than 3 HP upto 5 HP |
| 7 | All as per Srl item No 5 here-in-before but more than 5 HP upto 7.5 HP |
| 8 | All as per Srl item No 5 here-in-before but upto 40 HP |
| 9 | M&L for Dismantling and removing the centrifugal/ mono block/ Coupled pump set from the existing position after disconnecting the inlet/outlet piple connections, disconnecting the electric supply cables and transporting to repair workshop complete, opening the pump side, servicing the pump set including cleaning the shaft including replacement of worn out bearing, bushes, check nut, shaft sleeves,bush,impellers etc. and installing back to the original position, testing and commissioning on full load for 4 hrs continous running for the capacity of pump upto 3 HP complete all as specified and directed. |
| 10 | All as per Srl item No 9 here-in-before but more than 3 HP upto 5 HP |
| 11 | All as per Srl item No 9 here-in-before but more than 5 HP upto 7.5 HP |
| 12 | All as per srl item No 9 here-in-before but upto 40 HP |
| 13 | M&L in repairs for Gland packing of thickness upto 14mm complete all as specified and directed. |
| 14 | M&L in repairs Air Release Valve suitable size for mono block / Coupled pump set, made out of brass, as per site complete all as specifed and directed. |
| 15 | M&L for complete overhauling/ cleaning and recommissioning ofthe STPs including Dewatering the complete well, removing All the deposited sludge, soil and other material from the well including balling/ pumping out muddy water from the well by manually or by providing sutiable pump sets from bottom level of well, scrapping out the scales/ deposits from inner surface of the well throughly, washing with bleaching powder and soda ash, cleaning /balling out settled materials completely by any means and removing sludge to a distance up to 3 Km out side of defence land limit and dispose off in low lying area including dewarting as required including whitewash the inner side of sump, painting with existing color on outside & writing \"Tank cleaned on.......(date) with 10 cm size white letter on black surface by engaging skilled artist using first quality synthetic enamel paint ,dismantling the choked MS pipes, air diffusers in equalisation/MBBR tanks and refixing the same, providing with test report of treated water from govt. approved lab before completion of job. On completion providing training to the operators for operation of STP. |
| 16 | (a) STP of capacity 180 KLD at Anusandhan Vihar (Consists of Equilizer,MBBR,Tube settler,chlorine contact & treated water collection tank) Note : The plant will be taken over after successful completion of trial run for 15 days andthe rates also include complete cement paint and any repair to structures incl leakage to make it upto the mark. |
| 17 | M & L for preparation of old decorated wall surfaces by complete removal of existing treatment and applying two coats of cement base paints, white or tinted (colour and shade as per new colour scheme approved by GE over a coat of primer of same make including scaffolding for two story building complete all as specified and directed. |
| 18 | M & L for praparation by complete removal of existing treatment, washing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and directed. |
| 19 | Material and labour for MBBR media made of poly propylene with virgin plastic UV stabilized milky white specific gravity 0.95 to 0.98complete all as specified. |
| 20 | M&L in replacement for ERW MS Pipe heavy duty of size 150 mm dia including specials as perdulypainted with 2 coasts of Anti Corrossive Synthetic enamel paint over a coat of Zync Chromate complete incl necessary welding works etc. complete all as directed |
| 21 | All as per Srl item No 20.00 here-in-before but 80 mm dia |
| 22 | All as per Srl item No 20.00 here-in-before but 50 mm dia |
| 23 | All as per Srl item No 20.00 here-in-before but 40 mm dia |
| 24 | All as per Srl item No 20.00 here-in-before but 25 mm dia |
| 25 | M&L in replacement of CI butterfly valve with CI Disc and neoprene lining, 150mm dia ISI Marked including necessary heavy duty gasket, G.I. Bolts, G I Nuts, G I Washers etc. complete all as specified and directed. |
| 26 | All as per Srl item No 25 here-in-before but 80 mm dia |
| 27 | All as per Srl item No 25 here-in-before but 50 mm dia |
| 28 | M&L for preparing the surface by scrapping the old painting and removing the grease, oil, dirt, algae etc. Painting of outer surfaces of MS pipes with one coat of black Japanpaint over a coat of Zync Chromate complete incl its MS supports/ clamps / nuts/ bolts and marking / writing flow arrows and name with white paint by skilled painter All as directed of size 150 mm dia complete all as specified and directed. |
| 29 | All as per Srl item No 28 here-in-before but 80mm dia |
| 30 | All as per Srl item No 28 here-in-before upto 50mm dia |
| 31 | All as per Srl item No 28 here-in-before upto 25mm dia |
| 32 | S&F in repair and connect, MCB SP 6 to 32 A, AC, 240V,10KAISI Marked complete all as specified and directed. |
| 33 | S&F in repair and connect, Isolator SPN, 32A, AC, 240V,10KA ISI Marked complete all as specified and directed. |
| 34 | S&F in repair and connect, Isolator TP, 25-63A AC,10KA 415V, ISI Marked complete all as specified and directed. |
| 35 | S&F in repair and connect, Isolator TPN, 16-32A , AC, 415V,10 KAISI Marked complete all as specified and directed. |
| 36 | S&F in repairs and connect, Single Phase Preventer, 415 volts Suitable for motor protection complete all as specified and directed. |
| 37 | S&F in repairs and connect, 3 phase MNX 45 Contactor 45 amp with 230V coil complete all as specified and directed. |
| 38 | S&F in repairs and connect, 3 phase MNX A2 contactor 10 to 30A amp 415V with 230V coil complete all as specified and directed. |
| 39 | S&F in repairs and connect No-NC auxiliary contact block suitable for MNX 45 3 phase contactors complete all as specified and directed. |
| 40 | S&F in repairs and connect No-NC auxiliary contact block suitable for MNX A2 3 phase contactors complete all as specified and directed. |
| 41 | S&F in repairs and connect, over load Relay 3 Phase, 415V, 32 Amp complete all as specified and directed. |
| 42 | S&F in repairs and connect, over load Relay 3 Phase, 415V, 50 Amp complete all as specified and directed. |
| 43 | S&F in repairs and connect, over load Relay 3 Phase, 415V, 125 Amp complete all as specified and directed. |
| 44 | Supply only insulation tape roll 20 mm wide 15 Mtr long ISI mared complete all as specified and directed. |
| 45 | S&F in reapirs, testing multifunction meter ( V+A+F+PF ) 96mm x 96mm, digital type complete all as specified and directed. |
| 46 | S&F in repair Digital ammeter of existing size 100mm (Square type) and connecting up complete all as specified and directed. |
| 47 | S&F in replacementElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 50 HP capacity complete all as specified and directed. |
| 48 | S&F in repairs, Pressusre Gauge, 100mm dia, 0-14 Kg/cm pressure rating complete all as specified and directed. |
| 49 | Supply and Laying in trenches or fixed to wall / pole, PVC insulated, armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade laid in trenches/fixed in wall/ pole of cross esctional area of cable 2.5 Sqmm 3 core incl taking down old unsv cable complete all as directed. |
| 50 | All as per Srl item No 49.00 here-in-before but 6 Sqmm 3 core |
| 51 | Supply and Laying in trenches or fixed to wall / pole, XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade laid in trenches/fixed in wall/ pole of cross esctional area of cable 16 Sqmm 4 core incl taking down old unsv cable complete all as directed. |
| 52 | All as per Srl item No 51.00 here-in-before but 50 Sqmm 3.5 core |
| 53 | All as per Srl item No 51.00 here-in-before but 120 Sqmm 3.5 core |
| 54 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe, electric pole, stay assembly etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 55 | M&L for cutting hard standing/ Road cutting for taking up or laying of LT UG cable/pipe upto a depth of 15cm and after laying of cable, well rammng to the excavated soil and repair the cutting/exvcavated portion of road by providing PCC (1:2:4) type B1 (using 20mm graded stone aggregate) complete all as specified and directed. |
| 56 | Returning, filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm. in soft/loose soil complete all as specified and directed. |
| 57 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soft/losse soil complete all as specified and directed. |
| 58 | Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable / cable duct. (Only punned thickness shall be measured for payment purpose) complete all as specified and directed. |
| 59 | M&L for sub class \"B\" burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed |
| 60 | M&L for Galvanized steel tubing, light grade, with All fittings of size 40mm dia for protection of cable including taking down old, rusted & corroded unsv Galvanized steel tubing complete all as specified and directed. |
| 61 | S&F in replacement, Rotometer/Air flow indicator make as per existing complete all as specified and directed. |
| 62 | S&F in repairs, Hot drawn steel bolts, nuts, & washers, any type or size suitable for the purpose complete all as specified and directed. |
| 63 | M&L for Strucutral Steel Work, made out of Fe 410-W (Gde-E-250) quality A Rolled Mild Steel Channel, Angle or Tee Sections, MS Sheet with hinges & locking arrangements etc. cut to shape/ ordinary length, drilled and countersunk for Screws / Bolts, including bending and welding duly painted with 2 coats of Anti Corrossive synthetic enamel paint over a coat of Zinc Chromate as in framed work with MS Sheet cover complete all as specified and directed. |
| 64 | M&L for Cement concrete for coping/ support / foundation of GI pipes, Pumpsets etc. incl necessary breaking or digging of floor Type B1, 1:2:4, using 20 mm graded stone aggregate incl necessry form work and faci finish to exposed surface complete all as specified and directed. |
| 65 | Supply only DWPE (Dewatering Polyelectrolyte) powder, pack of 10/25Kg in polythene bags /HDPE drums complete all as specified and directed. |
| 66 | Supply only CHLORINE 65%-70% calcium based granular, disinfectant for STP water, pack of 40/45 Kg in HDPE drums complete all as specified and directed. |
| 67 | Supply only Sodium Hypo Chlordie (10%) in Liquid form, as purifier of STP water, packing in 50 Ltr Can complete all as specified and directed. |
| 68 | Supply only Calcium Hydroxide (Lime, 80-85%) in Powder form as pH Booster for STP water, packing in 40 Kg Sacks complete all as specified and directed. |
| 69 | Supply only Ortho Tolidin solution for testing of dissolved chlorine in water complete all as specified and directed. |
| 70 | Supply only Chlorination testing glass test Tube kit complete all as specified and directed. |
| 71 | Supply only Bacteria culture in PVC shells sutiable for MBBR type plant complete all as specified and directed. |
| 72 | M&L for cutting and removing of grass/bushes etc of any height grown inside STP premises and surrounding lift wells to keep the site clean and to carryout day to day maint and operations safely, grass cutting to be done as per site requirements & to the satisfactory level all as directed by Engr-in-Charge. |
| 73 | S&F in repair street / security light fitting of any description, supply, fix and connect 90 watts LED integrated street / security light fitting with all accessories alongwith 32 mm GI bracket with suitable clamps, bolts, nuts, & Washers incl provision of two core 2.5 Sqmm stranded Aluminium conductor cables of suitable length complete all as specified and directed. |
| 74 | Material and labour forcoarse bubble diffuser withHDPE pipe grid with necessary orifices HDPE pipewith removable reflector to provide clog-free oxygen for Equalisation Tank complete all as specified including dismantling and taking out the old damaged diffuser. |
| 75 | Material and labour forfine bubble diffuser along withEPDM membranes, SS 304 clips PVC support pipe to provide clog-free oxygen for MBBR/ Aeration Tanks complete all as specified including dismantling and taking out the old damaged diffuser. |
| 76 | Testing of water samples of STP before and after treated for the parametes of PH, TSS, BOD, COD, O&G done through the certified labs complete all as specified and directed |
| 77 | Supply & fixing in replacementof FRP construction solution (chemical dosing system plunger type solution 0 to 25LPHcomprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor, agitator with ss sweep blade duly FRP coated , FRP tank 150 liters capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with chemical grade PVC NRVall as specified and directed. |
| 78 | M&L Brick work in CM (1:4) with sub class \"B\" bricks above ground level and not exceeeding 1.5mtr in height from ground level including demolition of old unserviceable brick work complete all as specified. |
| 79 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 80 | M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate)foundations, filling and mass concrete complete all as specified and directed. |
| 81 | M&L for rendering 10 mm thick plaster on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement as specified. |
| 82 | S&F in replacement of motor of domestic RO of capacity 100 GPD complete all as specified and directed. |
| 83 | S&F in replacement of SV-SLX- of domestic RO complete all as specified and directed. |
| 84 | S&F in replacement of Membrane ECO of domestic ROcomplete all as specified and directed. |
| 85 | S&F in replacement ofInline filters (Sediment filter,Carbon filter) of domestic ROcomplete all as specified and directed. |
| 86 | S&Fin replacement of UV LED of domestic ROcomplete all as specified and directed. |
| 87 | S&F in replacement of UV barrel of domestic ROcomplete all as specified and directed. |
| 88 | S&F in replacement of SMPS 24 of domesticROcomplete all as specified and directed. |
| 89 | S&F in replacement of CTO 10\"\"/20\"\" of ROas required on site complete all as specified and directed. |
| 90 | S&F in replacement of SPUN Filter of 10\"\"/20\"\" of ROas required on sitecomplete all as specified and directed. |
| 91 | S&F in replacement of Outer Bowl of domestic ROcomplete all as specified and directed. |
| 92 | S&F in replacement of GAC of 10\"\"/20\"\" of ROas required on site complete all as specified and directed. |
| 93 | S&F in replacement of elbow,Tee of domestic ROcomplete all as specified and directed. |
| 94 | S&F in replacement of Pipe (30 mtr) of domestic ROcomplete all as specified and directed. |
| 95 | S&F in replacement of Membrane Houseing of domestic ROcomplete all as specified and directed. |
| 96 | S&F in replacementmembrane of size 80mmx40mm complete all as specified & directed |
| 97 | All as per ser item No. 96.00 above but 20\"X 4.5 \"diafor wound cartriagewater treatment plant complete all as specified & directed |
| 98 | All as per ser item No. 96.00 above but 30\"X 2.5 \"dia for PP filter water treatment plant complete all as specified & directed |
| 99 | Supply only sodium hypochloride (liquid bleach) 10 % (20 ltr each pack) |
| 100 | Supply only CX-002 RO Antiscalant Solution (25 kg each pack) |
| 101 | Opening of nuts, bolts of top and bottam cover of dual filter media and remvingthe 1.5\" = 600 Kgs\", 1\" 600 Kgs\", ½\" = 550 Kgs\" pebbles,4/8 = 700Kgs, 8/16 = 700 Kgs and 16/32 = 700Kgs silca sand from the dual filter. Re-used the 75% 1.5\"\" and 1\"\" pebbles after proper cleaning and washing and supply and re-filling the following:- (a) Re-filling 1.5\"\" pebbles = 450 Kgs.(b) Re-filling 1\"\" pebbles = 450 Kgs. (c) Supply and filling 1.5\"\" pebbles = 150 Kgs (d) Supply and filling 1\"\" pebbles = 150 Kgs. (e) Supply and filling ½\"\" pebbles 500 Kgs. (f)Supply and filling 4/8 silca sand = 700 Kgs. (g)Supply and filling 8/16 silca sand = 700 Kgs. (h)Supply and filling 16/32 silca sand = 700 Kgs. |
| 102 | M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer on old/new steel surface including preparation of surfacecomplete all as specified and directed. |
| 103 | Testing of drinking water being collected from local source (bore wells/sump /shallow wells) of KWC Area House Area underGE(I) R&D Delhi and submission of detailed test report to the office of Engr-in-Charge. (a) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in GOVT Approved laboratory as mentioned in specification.(b )Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) and to this office with specific recommendation regarding suitabiulity of water for drinking purpose.Note:- Rate Quoated shall deemed to be included for :- (i) Cost of sterilized bottle as required.(ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) (iii) Testing should be carried out from Govt approved lab. |
| 104 | Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric Centrifugal/Monoblock/High pressure motor ofcapacities7.5HP to 15 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed . |
| 105 | All as per item No 104above but of capacity more than 15-30 HP |
| 106 | Opening the electric Centrifugal/Monoblock/High pressure/openwell motor ofcapacity 7.5HP to 15 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material & relacement of bearings,repair of shaft to make it functionalcomplete all as specified and as directed . |
| 107 | All as per item No 106 above but of capacity more than 15-30 HP |
| 108 | Disconnecting and De-coupling the Centrifugal/Monoblock/High pressure/openwell pump ofcapacity 7.5HP to 15 HP from foundation after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for repairand back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed. |
| 109 | All as per item No 108 above but of capacity more than 15-30 HP |
| 110 | Opening the Centrifugal/Monoblock/High pressure pump ofcapacity, 7.5HP to 15 HP repairing the same by replacing the unserviceable spare parts (i.e impeller,shaft,bearings,seal etc) including machining work and re-assembling the same in original position complete all as specified and as directed.Note:-All Spare Parts required to make pump fully functional is deemed to be included in above quoted rates. |
| 111 | All as per item No 110.00 above but of capacity more than 15-30 HP |
| 112 | Supply and laying in replacement of Unplasticised PVC pipes of dia 15/16 mm of pressure rating 10 kgf/cm2 fixed complete to trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 113 | Supply and laying in replacement of Unplasticised PVC pipes of dia 20 mm of pressure rating 10 kgf/cm2 fixed complete totrench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 114 | Supply and laying in replacement of Unplasticised PVC pipes of dia 25 mm of pressure rating 10 kgf/cm2 fixed complete totrench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 115 | Supply and laying in replacement of Unplasticised PVC pipes of dia 40 mm of pressure rating 10 kgf/cm2 fixed complete totrench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 116 | Supply and laying in replacement of Unplasticised PVC pipes of dia 50 mm of pressure rating 10 kgf/cm2 fixed complete totrench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 117 | Supply and laying in replacement of Unplasticised PVC pipes of dia 80 mm of pressure rating 10 kgf/cm2 fixed complete toto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 118 | Supply and fixing in replacement of UPVC Ball Valves of size 16 mm (1/2”) dia complete all as specified and directed. |
| 119 | Supply and fixing in replacement of UPVC Ball Valves of size 20 mm (3/4”) dia complete all as specified and directed. |
| 120 | Supply and fixing in replacement of UPVC Ball Valves of size 25 mm (1”) dia complete all as specified and directed. |
| 121 | Supply and fixing in replacement of UPVC Ball Valves of size40 mm (1½”) dia complete all as specified and directed. |
| 122 | Supply and fixing in replacement of UPVC Ball Valves of size50 mm (2”) dia complete all as specified and directed. |
| 123 | Supply and laying in replacement of CPVC pipes of outer dia 16 mm SDR 11 & Plain CPVC SDR 11 fittings to trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 124 | Supply and laying in replacement of CPVC pipes of outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings onto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 125 | Supply and laying in replacement of CPVC pipes of outer dia 25 mm SDR 11 & Plain CPVC SDR 11 fittingsto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 126 | Supply and laying in replacement of CPVC pipes of outer dia 40 mm SDR 11 & Plain CPVC SDR 11 fittingsto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 127 | Supply and laying in replacement of CPVC pipes of outer dia 50 mm SDR 11 & Plain CPVC SDR 11 fittings to trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 128 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 16 mm (1/2”) dia complete all as specified and directed. |
| 129 | Supply and fixingin replacement of CPVC Ball Valves with brass threaded (two sided) , 20 mm (3/4”) dia complete all as specified and directed. |
| 130 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 25 mm (1”) dia complete all as specified and directed. |
| 131 | Supply and fixingin replacement of CPVC Ball Valves with brass threaded (two sided) , 40 mm (3/2”) dia complete all as specified and directed. |
| 132 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 50 mm (2”) dia complete all as specified and directed. |
| 133 | S&F in repair Submersible pump of capacity 7.5HP of outlet size 50mm, electric driven 415 V, 3 phase suitable for 150/200 mm dia bore well of flow rate 510-110 lpm with head range 30-96 mtrs inclusive of 40 metre long submersible flat cable and starter complete all as specified & directed. |
| 134 | S&F in repair MS tubing heavy duty,Class -C, column pipe,size 50 mm bore, 3 meter long, Conforming to IS-1239, coupled with heavy dutysuitable size MS flanges 12mm thick duly welded on both sides with and including necessary nuts, bolts , washers , rubber packing etc and lowered into the bore well after taking down/out old unserviceable column pipe complete all as specified and as directed . Notes: - (i)Length of Eachcolumn pipe shall be 3 Mtrs.(ii) Taking down/out and Lowering of Submersible pump set shall be measured and paid separately. |
| 135 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 150 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 136 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 100 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 137 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 80 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 138 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 50 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 139 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 25 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 140 | Supply and fixing in replacement SS (Stainless Steel) Single head landing valve with 80/100 mm N.B.flangedinlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290.Includingfixing with anchor fastener and flanged tappingfromwet risercomplete all as specified and directed. |
| 141 | Supply and fixing in replacement SS (Stainless Steel) double head landing valve with 80/100 mm N.B.flangedinlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290.Includingfixing with anchor fastener and flanged tappingfromwet riser complete all as specified and directed. |
| 142 | M&Lin replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed. |
| 143 | Supply and Fixingin replacement 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe,20 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete all as specified and directed. |
| 144 | Supply and fixing in replacement ofNon-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and length as described below. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & femalecoupling (IS:903) bound & riveted to hose pipe with aluminum rivets & 1.5 mm GI wire. (For Internal Hydrant & External Hydrant) complete all as specified and directed. |
| 145 | Supply and fixingin replacement of old unserviceable CI Non return Valve of dia 100 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 146 | Supply and fixing in replacement of old unserviceable CI Non return Valve of dia 150 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 147 | Supply and fixingin replacement sluice valve 80 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 148 | Supply and fixingin replacement sluice valve 100 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 149 | Supply and fixingin replacement sluice valve 150 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 150 | Supply and fixing in replacement ofswinging type First Aid hose reel in red color drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate gun metal valve stop cock, (IS:778, class - II) terminating with SS coupling&nozzleof 6 mm outlet with shut off valve confirming to IS 8090 - 1976complete withMS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts complete all as specified and directed. |
| 151 | Supply an fix in replacement Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of 4 way 63 mm dia instantaneous type male coupling with built in check valve and complete with all accessories complete all as specified and directed. |
| 152 | Supply and fixing in replacement of signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12\" x 6\" X 8 mm decorative transparent acralic, including fixing arrangement all as specified and directed. |
| 153 | M&Lin replacement of Pressure gauge 4\"dial 0-14 kgs rating complete all as specified and directed. |
| 154 | Supply and fixing in replacement air cushioning tank 250mm dia x 1000 mm high with dished top, made of minimum 6mm thick MS pipe/plate complete with 20mm dia. Brass air valve (ball type), 20 mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accesories complete all as specified and directed. |
| 155 | Supply and fixingin replacement branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 complete all as specified and directed. |
| 156 | M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer on steel surface all as specified and directed. |
| 157 | Provision of fire point with shade and accessories like as bucket, fire bitter, fire hook, digging tool including earth work, PCC & 02 coat of red paint on all surface & equipment etc complete all as specified and directed. |
| 158 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 0.4 mpa working pressure for 150 mm dia MS pipe complete all as specified and directed. |
| 159 | M&L Yard hydrant Post / Stand Post 80/100mm DiaMS both flanged type including reducer as per site requirement & 1.0 meter height above ground complete all as specified and directed. |
| 160 | Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out completeall as specified and as directed by Engineer-In-Charge. |
| 161 | All as per item No. 160.00 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc complete all as specified and directed. |
| 162 | Returning,filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge. |
| 163 | Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 164 | PCC (1:2:4) type B-1 finished even and smoooth without using extra cement as on brick pillars as specified. |
| 165 | Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric Centrifugal/Monoblock/High pressure motor ofcapacitiesupto 20 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for replacement and back, re-installed after replacement including testing complete all as specified and as directed . |
| 166 | All as per item No 165.00 above but of capacity of 40 HP and upto 75 HP |
| 167 | Opening the electric Centrifugal/Monoblock/High pressure motor ofcapacity upto 20 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weightincluding all other insulating material & relacement of bearings,repair of shaft to make it functionalcomplete all as specified and as directed . |
| 168 | All as per item No 167.00 above but of capacity of 40 HP and upto 75 HP |
| 169 | Disconnecting and De-coupling the Centrifugal/Monoblock/High pressure pump ofcapacity upto 20 HP,after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for replacementand back, re-installed at existing position after replacement and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed. |
| 170 | All as per item No 169.00 above but of capacity of 40HP and upto 75HP |
| 171 | Opening the Centrifugal/Monoblock/High pressure pump ofcapacity, upto 20 HP repairing the same by replacing the unserviceable spare parts (i.e impeller,shaft,bearings,seal etc) including machining work and re-assembling the same in original position complete all as specified and as directed.Note:-All Spare Parts required to make pump fully functional is deemed to be included in above quoted rates. |
| 172 | All as per item No 171.00 above but of capacity of 40HP and upto 75HP |
| 173 | S&F in replacement of Dry Chemical Powder Fire Extinguisher ( ABC Type ) 6 Kgs capacity completewith chromium plated gun metal union(cap), fitted with braided hose and opennozzle with initial charge of DryChemical Powder and gas cartridge (STORED PRESSURE TYPE)The extinguisher is internally coated with Lead Tinby electrolitic Process and externally coated with lead tin with Fire red Paint and cylinder bearing No. (IS:15683:2006) and the gascartridge bearing with ISI certitifcation markcomplete all as specified and directed. |
| 174 | Supply and fixingin replacement 3 pole power contactor type ML-5/6,80-160 Amps,415 Volts, 50 HZ complete all as specified and as directed. |
| 175 | S & F in replacement of Bimetal over load relay typeML 5/6, starter type MN, relay range 80-160 Amps CT operated complete all as specified and as directed. |
| 176 | S&F in replacement of3 Pole MCCB,250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 177 | S&F in replacement of 3 Pole MCCB,400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 178 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25mmx4mm by means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 5 of SSR Part-I & testing on completion :-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel shall be properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 179 | M&L GI strip 25mmx4mm buried in ground including necessary excavation & earth work in soft/loose soil and removal of excavated material to a distance n.exc 50 mtrs and deposited where directed including taking out old unserviceablecomplette all as specified & directed. |
| 180 | S&F in replacementElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 30 HP capacity complete all as specified & directed. |
| 181 | S&F in replacement 3 phase sequence relay suitable for 30 HP motor with supply voltage range of 200-480 VAC, frequency 50 Hz & response time less than 1 sec complete all as specified & directed. |
| 182 | S&F in replacementsingle phase preventor operating volt 280V to 520V VAC, 50Hz response time 200 MS suitable for 3 phase centrifugal motor upto 75HP complete all as specified & directed. |
| 183 | S&F in replacement Digital ammeter of existing size 100mm (Square type) with selector switch & copper thimble and connecting up incl taking down the existing complete all as specified and directed. |
| 184 | S&F in replacementDigital multimeter of existing size 100mm (Square type)with selector switch &copper thimble and connecting up incl taking down the existing complete all as specified and directed. |
| 185 | Supply & fix in repleacement of LED type Indicatinglamp type of voltage AC/DC set of RYB,as per matching to existing complete all as specified and directed.. |
| 186 | Supply & fix in repleacement of pressure switch of range 2-14 bar rating with suitable size & core cable upto 10 mtrs length incl taking down the existing u/s switch complete all as specified and directed.. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail