| 1 | Supply and fixing of Central Processing Hardware having the following specifications Intel Xeon®Quad core Dual Processor, 32GB RAM, 1TB Hot pluggable x 3 RAID 5 HDD, 256GB SSD Windows 11 as recommended by the SCADA manufacturer complete all as specified and directed. Make: Dell, HP, Lenovo. |
| 2 | Supply, Installation, Testing and Commissioning of 40-inch LED monitor, keyboard, mouse Features: Display Type: LCD, Resolution:1366x768, Table Top Or Wall Mount Screen Size:40\"\" Inches complete all as specified and directed. Make: Dell, Samsung, HP, AOC, LG. |
| 3 | Supply, Installation, Testing and Commissioning of SCADA software runtime with Suitable tags /Screens to be installed and deployed on the stand-alone PC along with report generation software and historian software with licences. Note: Price inclusive of Development of all screens and all necessary communication cables complete all as specified and directed. Make: DIAVIEW, Mitsubishi, Advantech. |
| 4 | Supply, Installation, Testing and Commissioning of A4 size Mono chrome LaserJet PrinterPrint speed black: Up to 14 ppm Print technology: Laser, Processor speed: 234 MHz Connectivity: Included Components LaserJet print cartridge, Getting Started Guide, printer documentation and software on CD-ROM, power cord complete all as specified and directed. Make: Canon, Epson, HP. |
| 5 | Deployment of SCADA operator cum Developer for handling and implementing on site SCADA system in general shift, scope includes flawless running of SCADA and complete automation system, attending all the required changes, events, and generation of reports as directed by engineer-in-charge for (development) for the period of 3 months complete all as specified and directed. Make: TFRS Electronics Pvt. Ltd. /Yuvan Energy /Onkar Enterprises |
| 6 | Deployment of a skilled technician cum operator for handling all site situations in general shift, scope includes troubleshooting of all panel and instruments problems for flawless running of SCADA and complete automation system for the period of 11 months complete all as specified and directed. Make: TFRS Electronics Pvt. Ltd. /Yuvan Energy /Onkar Enterprises |
| 7 | Supply, Installation, Testing and Commissioning of UPS for minimum 30 min of battery backup (with battery bank) for suitable running of SCADA computer complete all as specified and directed.Make: EATON/TOSHIB/GE |
| 8 | Supply, Installation, Testing and Commissioning of Broadband connection by the name GE(MIS) MHOW of any service provider of excellent speed. for the period of 1 year complete all as specified and directed. |
| 9 | Supplyinstalling ,connecting , testing and commissioning of design automation Panel of adequate size having degree of ingress protection IP-69, cubicle type, floor mounted made out of 1.8 mm thick CRCA sheet & MS angle section 50mmx50mmx6 mm frame with sloping roof top type panel cover & compartmentalized for following equipments controls, and door etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 1 phase, 2 wire, 240 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable \"\"U\"\" type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointingmaterial complete all as specified and directed with comprising of the following:-a) Automatic Valve Control (Motorised Operating Valve).b) Magnetic level Sensor for OHT water level control (5 Nos of Sensors)c)Single phase motorised operating valves control (2 Nos of MOV). Make : TFRS Electronics Pvt Ltd. |
| 10 | The panel shall consist of the following equipments :- (a) Selector Switch (Main AUTO/MAN Mode, VALVE Mode, Pump AUTO/MAN Mode). Make:Schneider/ESBEE/SCHINDLER/ C&S (b) Indicator Lamp 230V AC (RED, YELLOW, GREEN, BLUE) Make:Schneider/ESBEE/SCHINDLER/ C&S.(c) Relays / Relay card (24 V DC, 230V AC) MAKE: LEONE/IDEC/SCHNEIDER (d) Hooter/Alarm 230 V AC/24 V DC.MAKE: MINILEC/SCHNEIDER/L&T/C&S/MIMIC (e) Push Buttons & Push Button with LED indicator (24V DC, 240V AC). Make:Schneider/ESBEE/SCHINDLER/ C&S(f) SMPS of suitable current & voltage rating. INPUT 230V AC & OUT 24 VDC, 5 A.MAKE: L&T/ C&S/ MINWELL/SCHNEIDER/NHP (g) Step down Transformerof input 230VAC & output 12VAC, 2A. (h) Programmable Logic Controller (PLC 24V DC). MAKE: ALLEN BRADLEY/ SIEMENS/MITSUBISHI/UNITRONICS(j) 0.5 sqmm internal control wiring.MAKE: POLYCAB/FINOLEX/PRIMECAB/TORRENT.(k) Separate MCB’s for 24VDC & 230 VAC equipment & internal wiring. Supply:240V, 50 Hz Mounting: Floor Mounting type.(l) Water level controller. Make:- S M INSTRUMENTATION/ L&T/SIEMENS/ Universal Switch gear controlm) GPRS MODEM with antenna and Power adaptor Make: Maestro/Sheetal wireless/MCOM Technology/SM INSTRUMENTATION Note: Site Names: AGE (B/R) II, FORT, DHOBI GHAT, ROBERT BARRACK, MCTE-I |
| 11 | M&L for 17 Nos. OHT tank wireless level monitoring and integration with SCADA.5 Nos flow meter wireless monitoring, Daily water consumption flow rate report generation in SCADA complete all as specified and directed .Make: Technofriends /Yuvan Energy /Onkar Enterprises |
| 12 | Supplyinstalling ,connecting , testing and commissioning of design automation Panel of adequate size having degree of ingress protection IP-69, cubicle type, floor mounted made out of 1.8 mm thick CRCA sheet & MS angle section 50mmx50mmx6 mm frame compartmentalized for following equipments controls, andmeter etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable \"\"U\"\" type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointingmaterial complete all as specified and directed with comprising of the following:-a) Automatic Valve Control (16 Operational + 03 Spare Motorised Operating Valve). b) Pump control. (06 Nos of Pumps)c) 1 No. Chlorine dosing Pump. (Spare) (f) Pressure switch/Flow switch control(07 Nos of Pressure switchg) Automatic priming solenoid valves ( 07 Nos )(h) Ultra Sonic Level Sensor (01 No.(i) Water level sensors (05 No. Sensor)Make : TFRS Electronics Pvt Ltd. |
| 13 | The panel shall consist of the following equipments :- (a) Selector Switch (Main AUTO/MAN Mode, VALVE Mode, Pump AUTO/MAN Mode). Make:Schneider/ESBEE/SCHINDLER/ C&S (b) Indicator Lamp 230V AC (RED, YELLOW, GREEN, BLUE)Make:Schneider/ESBEE/SCHINDLER/ C&S.(c) Relays / Relay card (24 V DC, 230V AC) MAKE: LEONE/IDEC/SCHNEIDER (d) Hooter/Alarm 230 V AC/24 V DC.MAKE: MINILEC/SCHNEIDER/L&T/C&S/MIMIC(e) Push Buttons & Push Button with LED indicator (24V DC, 240V AC). Make:Schneider/ESBEE/SCHINDLER/ C&S (f) SMPS of suitable current & voltage rating. INPUT 230V AC & OUT 24 VDC, 5 A.MAKE: L&T/ C&S/ MINWELL/SCHNEIDER/NHP (g) Step down Transformerof input 230VAC & output 12VAC, 2A. (h) Programmable Logic Controller (PLC 24V DC). MAKE: ALLEN BRADLEY/ SIEMENS/MITSUBISHI/UNITRONICS |
| 14 | (j) 0.5 sqmm internal control wiring.MAKE: POLYCAB/FINOLEX/PRIMECAB/TORRENT. (k) Separate MCB’s for 24VDC & 230 VAC equipment & internal wiring. Supply:415V, 50 Hz Mounting: Floor Mounting type. (l) VSP-D2,SPP Make: Minilec(m) Water level controller.Make:- S M INSTRUMENTATION/ L&T/SIEMENS/ Universal Switch gear control n) GPRS MODEM with antenna and Power adaptor Make: Maestro/Sheetal wireless/MCOM Technology/SM INSTRUMENTATION o) Digital water level indicator Make: Minilec, Selectron, SchneiderNote: Site Names: OLD PUMP HOUSE AND KLP |
| 15 | Supply, Installation, Testing and commissioning of Flow/Pressure Switch 1-10KG/sq.cm with Pressure Guage and necessary fittings with proper wiring as directed by Engineer in charge complete all as specified and directed.Make: INDFOSS/DANFOSS/RAPID CONTROL |
| 16 | Supply, Installation, Testing, and commissioning of Air releasing solenoid valve for pumps having 10mm dia, 230 V AC operated coil complete all as specified & directed.Make:- ROTEX/AVCON/JOHNSON CONTROLS |
| 17 | Supply, Installation, Testing and commissioning of Priming solenoid valve/ Actuator having 25mm dia, 230 V AC operated coil complete all as specified & directed.Make: KARTAR/VENUS / KIRLOSKAR |
| 18 | Supply, Installation, Testing, and commissioning of motor actuator for butterfly valve/ Sluice Valve with the following specifications including all accessories (CI fittings required at site) complete allas specified and directed by Engineer-in-Charge(a) Valve size 100mm dia.(b) Operating Angle : 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC. (h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal.(l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible. Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 19 | Supply, Installation, Testing, and commissioning of motor actuator for butterfly valve/ Sluice Valve with the following specifications including all accessories (CI fittings required at site) complete all as specified anddirected by Engineer-in-Charge(a) Valve size 150mm dia.(b) Operating Angle: 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC.(h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal. (l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible.Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 20 | Supply, Installation, Testing, and commissioning of motor actuator for butterfly valve/ Sluice Valve with the following specifications including all accessories (CI fittings required at site) complete all as specified and directed by Engineer-in-Charge.(a) Valve size 200mm dia.(b) Operating Angle : 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC.(h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal.(l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible. Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 21 | Supply, Installation, Testing and commissioning of motor actuator for butterfly valve/ Sluice Valve with the following specifications including all accessories (CI fittings required at site) complete allas specified and directed by Engineer-in-Charge.(a) Valve size 250mm dia(b) Operating Angle : 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC.(h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal.(l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible.Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 22 | Supply, Installation, Testing, and commissioning of motor actuator for butterfly valve/ Sluice Valve with the following specifications including all accessories (CI fittings required at site) complete all as specified and directed by Engineer-in-Charge.(a) Valve size 300mm dia.(b) Operating Angle : 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC.(h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal.(l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible.Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 23 | Supply, Installation, Testing and commissioning of motor actuated butterfly valve with the following specifications including all accessories (CI fittings required at site) complete allas specified anddirected by Engineer-in-Charge.(a) Valve size 400mm dia.(b) Operating Angle : 90 degrees.(c) Degree of protection class: IP67/68.(d) Area of operation: Safe.(e) Manual over ride: Hand wheel provided (Stationary & opposite side of motor)(f) Mechanical Indicator: Provided Dome type for \"Open\" & \"Close\"(g) Optional supply available: 110V AC/24V AC.(h) Mechanical arrangement with Butterfly valves, Sluice Valves: Coupler/Brackets and extended shaft can be provided as per system requirements.(i) Integral starters with light weight metallic body having \"Open/close/stop selector switch & Open closed power indicators.(j) Limit switches: 1NO+ 1NC: 2 Nos. + 1NO+1NC: 2 Nos. extra auxiliary.(k) Motor Tripping signal.(l) Valve position indication with a Digital output.(m) The actuator should be capable of accepting Digital input for regulating purposes.(n) All actuators are PLC/SCADA/DCS compatible. Make : AUMA/ ROTORK / TFRS ELECTRONICS |
| 24 | Supply, Installing, Testing and Commissioning of Ultrasonic Level Transmitter complete all as specified and directed. Range : 0-7 metresAccuracy : 0.5 % minimumSupply Voltage : 24V dcOutput : 4-20 mAUltrasonic Frequency:75 kHz burst, rep. rate 96 msDelay at Power-up: 1.5 secondsTemperature Effect: Uncompensated: 0.2% of distance/°C &Compensated: 0.02% of distance/°CDelay at Power-up: 1.5 secondsResolution: 1.0 mmOutput Response Time: 100 ms to 2300 msMinimum Window Size: 20 mmEnvironmental Rating: Leakproof design is rated IEC IP67; NEMA 6POperating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F)Maximum relative humidity: 100%.Make: Technofriends. / Endress+ Houser/ SIEMENS/ BANNER /KROHNE MARSHALL |
| 25 | Supply & fixing in replacement 6 core, 1.5 sqmm cross sectional area armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed. Make: Polycab/FSC/Torrent/Finolex |
| 26 | Supply & fixing in replacement 4 core, 1.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.Make: Polycab/FSC/Torrent/Finolex |
| 27 | Supply & fixing in replacement 5 Pair, 0.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.Make: Polycab/FSC/Torrent/Finolex |
| 28 | Supply & fixing in replacement 2 core, 1.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls/on poles/in ducts/in GI pipes etc complete all as specified and directed.Make: Polycab/FSC/Torrent/Finolex |
| 29 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 30 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 31 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed. |