| 1 | Taking down cement plaster of any description on PCC/stone surface/brick surfaces including raking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 2 | Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed. |
| 4 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as directed. |
| 5 | Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed. |
| 6 | Dismantling of Asbestos cement Corrugated or semi corrugated sheets etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris tooutside MoD land and depositing where directed complete all as specified and as directed. |
| 7 | Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified and as directed. |
| 8 | Dismantling of fencing wire mesh of any type and any size complete all as specified & as directed. |
| 9 | Dismantling of post or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed. |
| 10 | Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance exceeding 500 m and making good surface in soft/ loose soil complete all as specified & as directed. |
| 11 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 12 | M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified & as directed. |
| 13 | M&L for factory madepre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed. |
| 14 | All as per serial item No. 13 here-in-above, but except PCC block -do-Note : PCC block retrieved serviceable under serial item No. 2 here-in-before shall be reused under this item. |
| 15 | M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed. |
| 16 | M&L for precast cement concrete (1:2:4 type B0 using 12.5mm graded crushed stone aggregate) louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4, complete all as specified & as directed. |
| 17 | S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete, all as specified & as directed. |
| 18 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed. |
| 19 | S&F mild steel round bars 10mm dia and over as in tie bars fixed to fencing posts and other similar works, cut to length, bent to shape required, including cranking, bending, binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips or welding of bar at spots as directed, conforming to Grade E-165 (Fe 290), with & including painting with two coats of aluminium paint over a coat of aluminium red oxide primer after preparation of surfaces, complete all as specified & as directed. |
| 20 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed. |
| 21 | S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed. |
| 22 | S&F mild steel framed work using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. complete all as specified & as directed. |
| 23 | M&L for expanded metal weight not exceeding 4 Kgs per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed. |
| 24 | Fixing only mild steel galvanized chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified & as directed.Note :- Supply only chain link fencing shall be measured and paid for separately. |
| 25 | Supply only mild steel galvanized chain link fencing (Coating 120 to 140 GSM) not more than 4mm dia of mesh wire, 75mm x 75mm mesh size (or as directed by Engineer-in-Charge) including line wire complete all as specified and as directed. |
| 26 | S&F stainless steel (Grade-304) railing and similar works made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size for gate with suitable arrangement as per approval of Engineer-in-Charge. (for payment purpose only weight of stainless steel members shall be considered excluding accessories such as nuts, bolts, faterners etc). |
| 27 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed.Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc |
| 28 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ cladding to walls, ridges, gutters, valleys etc. fixed with self tapping screws complete all as specified & as directed.Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc |
| 29 | S&F 3mm thick Aluminium Composite Panel (ACP) sheets cladding, eaves, etc, vertical or horizontal, with and including fixing in necessary Aluminium frame work flat, angle or T as per best trade practice and filling the joints/grooves with non staining silicone sealant including fixing of angle cleats, screws etc for height upto 12 metre from average ground level complete all as specified and as directed. Make : Viva, Aludecor, Reynobond, Virgo, Alex Panels, Indo Bond, Euro bond, Alstrong, Rinac, Areca Alupanel or equivalent as approved by GE.Notes : (i) Colour of ACP sheets shall be as approved by GE. (ii) Frame work is included in this item. (iii) The decision of GE regarding Frame work as per best trade practice shall be final & binding. (iv) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc. |
| 30 | M&L for 16 to 18 mm thick granite slab (Jet Black) work (table rubbed, polished and rounding of edges where ever necessary as ordered) as in flooring & the like, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 20mm thick screed bed in cement mortar 1:4 complete all directed and specified.Note : Quoted rate shall deemed to be inclusive of rounding of edges and cement screed bed/bedding layer. |
| 31 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm gradedcrushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. |
| 32 | M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE. |
| 33 | M&L for factory made M-40 grade, 80 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE |
| 34 | M&L for machine pressed coloured chequered cement concrete tiles of size 295x295x25 mm thick with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade of tiles and laying over & including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.Notes: (i) Quoted rate shall deemed to be inclusive of cement screed. (ii) Colour & design / pattern of tiles shall be got approved from GE before incorporation in the work. |
| 35 | M&L for outdoor heavy duty vitrified parking coloured (glossy finished) tiles of size 300 x 300 x 15mm thick as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour & design of tiles shall be got approved from GE before incorporation in the work. |
| 36 | M&L for precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Kerb block (Kerb Stone), factory casted, with plain fair faces, size 10cm x 30cm each or as directed, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, fixed in position to the required line, level and curvature including making drainage opening wherever required, complete all as specified & as directed.Note : Shape & size of Kerb blocks shall be as approved by the GE. |
| 37 | Dismantling carefully existing serviceable precast cement concrete Kerb block (Kerb Stone) of any size with plain or interlocking joints and re-setting/re-fixing in & including cement mortar 1:4, complete all as specified & as directed. |
| 38 | M&L for Rendering 20 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer\"s instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as \"Supply only\". |
| 39 | M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and as directed. |
| 40 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed. |
| 41 | M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. |
| 42 | M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing of surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. |
| 43 | M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over & including 1mm thick water proof wall care putty suitable for exterior surfaces exposed to weather as per manufacturer\"s instructions complete all as specified and as directed. |
| 44 | M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and Jet pressure washing and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm applied by mechanicalmeans i.e Airless spray complete all as specified and as directed. |
| 45 | M&L for preparation of new concrete/plastered surfaces of Kerb stones, decorative wall and the like and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) in alternate panels in different shade/tint with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer\"s instructions complete all as specified and as directed.Note : Painting to Kerb stones, decorative wall, etc in alternate shade/tint as approved by Engineer-in-Charge shall be carried out. |
| 46 | M&L for preparation of oldpainted surface of Kerb stones, decorative wall and the like and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm as per manufacturer\"s instructions in alternate panels in different shade/tint complete all as specified and as directed.Note : Painting to Kerb stones, decorative wall, etc in alternate shade/tint as approved by Engineer-in-Charge shall be carried out. |
| 47 | M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed. |
| 48 | M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed. |
| 49 | Supply only Integral Water Proofing Compound (ISI Marked). |
| 50 | M&L for cement concrete (Quality Concrete) work in pavement/hard-standing of flexural strength 40 Kg per square centimeter in field using 400 Kg of cement per cubic metre, thickness of concrete 25 cm or less,including necessary form work for laying in bays between joints & contraction, expansion joints/or between the two contraction joints, finishing surface of concrete roads, pavements, pavings etc by brooming whilst the concrete is green, complete all as specified & as directed.Notes :-(i) The construction, dummy (contraction) & expansion joints shall be measured separately under respective items.(ii) Design mix shall be approved by GE before execution of the work. In case, quantity of cement as per actual design mix works out less than 400 Kg per cum of concrete, then minimum cement as 400 Kg/Cum of concrete shall be used without any extra cost to Govt. In case cement as per actual design mix is more than the 400 Kg/cum of concrete, the actual quantity as per design mix shall be used in the work without any extra cost to Govt. |
| 51 | M&L for forming Construction joints 30mm deep x 10mm wide, filled with sealing compound Grade \"A\" complete all as specified. |