| 1 | Supply and Layingof XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 185 Sqmm 3.5 core in trenches or fixed on wall/floor/ polecomplete all as spd and directed. |
| 2 | Supply and Laying of XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 120 Sqmm 3.5 core in trenches or fixed on wall/floor/ polecomplete all as spd and directed. |
| 3 | Supply and Laying XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 95 Sqmm 3.5 core in trenches or fixed on wall/floor/ polecomplete all as spd and directed. |
| 4 | Supply and Laying XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 50 Sqmm 3.5 core in trenches or fixed on wall/floor/ polecomplete all as spd and directed. |
| 5 | Supply and LayingXLPE LTUG cable PVC insulated,beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sqmm 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 6 | Supply, installing, errecting, testing and commissioning, factory made and tested LT Panel board with all accessories.LT Panel board, OUT DOOR type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminum busbars to be installed on porcelain / SMC insulators PVC insulated red blue and yellow colour and all interconnection between main busbars as well as outgoing feeders shall be carried out with TPN Aluminum busbar of rating not less then 1.5 times rated capacity of individual out going feeders. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA sheet and 50x50x6mm thick angle iron frame work, bottom channel of size: 70x40x5 mmpowder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,front / back opening type, andfixing 2 Nos.danger notice plate of thickness 02 mm with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel etc with voltage and danger indiated in Hindi and English, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys,internal wiring with PVC insulated,stranded copper conductor, FRLSH cables, IS-694marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45cm above the nearest groundlevel. complete all as specified and directed including connections of all out going/in coming existing cables of size 16 to 185sqmm by drawing /digging out cable from loops in trenches/ ductsout side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Alluminium lugs for terminal connections of cables, Platform for the panel with PCC 1:4:8 type D-2 With 40 mm graded crushed stone , 15 cm thick in foundation and 100 mm thick PCC Padding 1:3:6,type C-1 using 20 mm graded crushed stone aggregate on top and grouning bolts etc. All out going feeders shall be connected by cable through suitable size gland plate / glands. |
| 7 | (I) Incoming :- (i) Aluminum busbar, 4 Pole, 400 Amps (ii) MCCB 4P, 250A, 36 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos.(iii)Ammeter Digital type, CT operated 0-300A range,(with selector switch and CT) - 01 Set(iv)Volt Meter Digital type 0-500 V range,(With selector switch) - 01 No.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set. |
| 8 | (II) Outgoing :-(i) MCCB 4P, 100A, 25 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 02 Nos.(ii) MCCB 4P, 63A, 16 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 03 Nos. |
| 9 | All as per Srl item No 6 above,but with followings:- |
| 10 | (I) Incoming :- (i) Aluminum busbar, 4 Pole, 600 Amps (ii) MCCB 4P, 400A, 36 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos.(iii)Ammeter Digital type, CT operated 0-600A range,(with selector switch and CT) - 01 Set(iv)Volt Meter Digital type 0-500 V range, (With selector switch) - 01 No.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set. |
| 11 | (II) Outgoing :-(i) MCCB 4P, 200A, 25 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 02 Nos(ii) MCCB 4P, 125A, 25 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos.(iii) MCCB 4P 63 A , 16 KA with thermal magnetic O/L & S/C Protection ,ICS= 100% ICU= 01 Nos. |
| 12 | Supplying, installing, commissioning, testing of LT switchgear panel board (Kiosk) of size not less than 600mm x 600mm x 500mm, IP-65(outdoor type) 415 Volts, 50 Hz, ACsupply, three phase and neutral (4 wire), 200 Amps coloured horizontal tinned Al busbars, factory made out of 3.15mm thick CRCA MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in Platform for the Panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone ,15 cm thick in foundation and 100 mm thick PCC Padding 1:3:6,type C-1 using 20 mm graded crushed stone aggregate on top and grounting bolts etc. duly epoxy powder coated internally and externally with approved shades, rubber gasketed, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof, complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415 Volts, 36 kA, 50 Hz-01 Nos (incoming), Including indication lamp, Danger Plate of suitable size. suitable size cable al lugs, glands and making connections/wiring with suitable size PVC insulated copper conductor cable. |
| 13 | Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay andpipe line,and getting out complete all as specified and directed |
| 14 | Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified. |
| 15 | Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified. |
| 16 | M&L for fly ash old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
| 17 | M & L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand complete all as directed |
| 18 | Dismantling the existing LT over head line (ACSR conductor) carefully any size from LT pole including disconnecting electric connection) complete all as specified & directed. |
| 19 | Dismantling/taking down carefully insulator any size and any type from existing LT lines complete all as specified and directed. |
| 20 | Dismantling of cross arms of MS channel or angle iron section with clamps etc. complete all as specified and directed. |
| 21 | Dismantling the existing stay assembly complete all as directed. |
| 22 | M&Lfor earthing complete with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) withtop edge of the plate not less than 1.5mtr below ground level connected to galvanised strip 25x4 mm size as earthing lead by means of bolts, nuts, check nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth workin any type of soil , removal of surplus soil to a distancen.exc 50m and connecting , testing on completion all as shown on electricplate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 23 | Material and labour for GI tubing light grade 100 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed . |
| 24 | Material and labour for GI tubing light grade 50 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed . |
| 25 | Material and labour for GI tubing light grade 40 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed . |
| 26 | M & L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100mm bore GI tubing of any description below/under road surface/floorsetc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing after laying pipes complete all as specified and directed |