| 1 | Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc laid beded and pointed in any mortar complete all as specified and as directed. |
| 2 | Demolition of cement concrete in ground floor n exc 15 cm thick (un reinforced) complete all as specified and directed. |
| 3 | M&L for hardcore(brocken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 4 | Reinforced concrete pipe 450 mm bore class NP3 laid and jointedcomplete with collars complete all as specified and directed. |
| 5 | M&L for Desilting of area drainage of any size and shape and removing the sludge or solid contents from the drainage by manual and mechanical methods or any other suitable means at the discretion of contractor at his own arrangement and make drainage fully functional to the entire satisfaction. complete all as specified and directed. |
| 6 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil. |
| 7 | Excavation in trenches n exc 1.5m wide and n exc 1.5m depth, for foundation, etc. or for shafts, wells, cessipts, manholes, etc. n exc 10 Sqm on plan and n ecx 1.5 m in depth and getting out soft/losse soil. |
| 8 | M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete. |
| 9 | M&L for Brick work with sub class old size \"B\" brick stright or curved on plan exc 6m mean radius built in CM 1:6. |
| 10 | M&L for brick work with sub class \"B\" bricks straight or curved on plan to anyradius built in CM 1 : 4 in half brick thick walls. |
| 11 | M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. |
| 12 | M&L for randering 15 mm thick on other than fair faces of brick work or concrete surface in CM 1:4 and rendering is to be finish. |
| 13 | M&L for 5mm thick rendering on concrete surface of ceiling in CM 1:3and rendering is to be finished even and smooth with out using extra cement |
| 14 | M&L for three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces. |
| 15 | M&L for two coats of cement base paint on newely plaster surfaced of walls including preparation of newly surface. |
| 16 | S&F aluminum anodized glazed ventilators with frame of standard section and grill including provision of glazing with 5 mm thick glass fixed to frame,rubber beading , handles and tower bolts etc all as specified and directed as in repairs including removing of old steel windows |
| 17 | M&L Brickwork with sub-class \"B\" bricks laid on flat, in floors bedded and jointed in CM 1 : 6 and pointed in cement mortar 1:6 complete all as specified and directed. |
| 18 | M & L Bricks, sub class B, laid on edge in drain bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed. |
| 19 | M&Lfor PCCtype B01:2:4 (Using 12.5 mm graded aggregate) as in coping inclluding weathering, slightly rounded or chamfered angles and throating including necessary form workcomplete all as specified and directed. |
| 20 | M&L for PCC type B11:2:4 (20mm graded aggregate) copings, kneelers, apex stones, bed plates, kerbs not provided , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and specified |
| 21 | M&Lfor PCC 1:2:4 type B1 (20mm graded aggregate) cement concrete in surface channels and drains complete all as specified and directed. |
| 22 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc complete all as specified and directed. |
| 23 | M&L for precast reinforced cement concrete 1:2:4, type B1 (using 20mm graded aggregate) as in cover slab of manholes, septic tank etc, set in cement mortar (1:4) including necessary form work, moulds etc and including taking out/removal of existing unserviceable cover slab form manholes/septictank complete all as directed by engineer-in charge (Note :- Reinforcement shall be measured and paid separately). |
| 24 | M&Lfor precast cment concrete type B1 1:2:4 (using 20mm graded aggregate) as in drain covers set in CM 1:6 complete all as specified and directed. |
| 25 | M&Lfor concrete bedtype D2 PCC 1:4:8(using 40mm graded aggregate)to drain pipes 150 mm internal dia including packing under, and haunching against the sides of pipes after they are laid & tested dia complete all as specified and directed. |
| 26 | M&L for 150 mm bore reinforced concrete pipe, class NP2, laid and jointed (in CM 1:1) complete with collars all as specified & as directed |
| 27 | M&L for TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified |
| 28 | All as per Item No.27 here in above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders |
| 29 | M&L for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and includeing mild steel wire (annealed) not less then 0.9mm dia or securing with clips as specified |
| 30 | Use and waste of form work to sides of concrete foundations ,footings , bases of columns ,raft and raft beams , sides and soffits ( if any)of foundation and plinth beams and similar vertical or to a batter flat rough finished surface |
| 31 | Use and waste of form work to sides of pillars , posts , struts , piers , columns and stantions rough finished surface square , rectangular or polygonal |
| 32 | Use and waste of form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc fair finished surfaces of concrete flat all as specified |
| 33 | Use and waste of form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified |
| 34 | Use and waste of form work to edges of concrete flates ,treads break in floors ,window cills ,concrete railings , openings in concrete walls, floor and roofs n exc 20 cm wide and sisides of RCC/PCC bands in walls, horizontal or sloping and ssimilar work exc 10 cm but n exc 20 cm complete all as specified and directed. |
| 35 | M&L for providing RCC (Nominal mix) type B1 (1:2:4) using 20 mm graeded stone aggregate as infoundation ,including rafts,footings foundation beams , plinth beams, bases of columns etc ,basement slab ,underreamed piles and mass concreteall as spec |
| 36 | M&L for providing RCC (Nominal mix) type B1 (1:2:4) using 20 mm graeded stone aggregate as in beam, cantilever,bressumers, lintel over 1.5 mtr span concrete flat all as specified. |
| 37 | M&L for providing RCC (Nominal mix) type B1 (1:2:4) using 20 mm graeded stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. |
| 38 | M&L for hard core of gauge exc 63mm but not exc 100 mm depoted ,spread and levelled in layers not exc 15 cm thick watered and rammed to a true surfacebroken stone or boulders |
| 39 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base |
| 40 | Removing excavated materialn exc 50mand depoting where directed at a level n exc 1.5m above the starting point (soil) complete all as specified and directed. |
| 41 | Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and directed. |
| 42 | S&F rotational moulded polyethylene water storage tank consisting of three laver cylindrical vertical with top closed hoisted and fixed in position all as specified and directed capacity 1000 ltrs. |
| 43 | S&F 20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe |
| 44 | S&F 15 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe |
| 45 | S&F 20 mm dia Ball valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule |
| 46 | S&F 15 mm bore Bip taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferruleand fixed. |
| 47 | Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of 20mm bore GI pipe |
| 48 | Supplying and laying outer diameter of CPVC pipes 20mm bore SDR 11 & Plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified. |
| 49 | Supplying and laying outer diameter of CPVC pipes 25mm bore SDR 11 & Plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified. |
| 50 | Supplying and laying outer diameter of CPVC pipes 32mm bore SDR 11 & Plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified. |
| 51 | Cutting chase, pinning in making good to faceing where required and pointing in cement mortar 1:3 to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making goodcutting exc 10cm but n exc 20cm complete all as specified. |
| 52 | S&F 15 mm bore Stop valves, Chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fancey type chromium plate complete all as specified. |
| 53 | S&F PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified. |
| 54 | S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement complete all as specified. |
| 55 | S&F 75 mm bore PVC (SWR) pipes ofsingle socketed in any length with rubber ring joints laid in trenches or in floors all as specified |
| 56 | S&F 75 mm bore. PVC (SWR) bends complete all as specified. |
| 57 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches |
| 58 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall |
| 59 | S&F 110 mm PVC (SWR) bend any radius complete all as specified. |
| 60 | S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door complete all as specified. |
| 61 | S&Fvitreous china squatting pan \"Orissa\" pattern size 580mmx440mm white with integral foot rests including 10ltrs capacity PVC flushing cistern low levl with inlet, ball valve float chain and pull and brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia for low level cistern all as specified |
| 62 | S&F 10 ltrs PVC valveless syphonic action typeflushing cistern low level white , with inlet ball valve, float and handle including bracketwith 32 mm dia PVC pipe 600 mm long complete all as specified and as directed. |
| 63 | S&FBrass Chromium plated Tubular Towel rail, 20mm dia, D type,60 cm long between flanges fixed to wall complete all as specified and directed. |
| 64 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm (400X400X7mm) in floor, over 20mm thick screed bed in CM 1:4 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. |
| 65 | M&L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. |
| 66 | M&L for glazed ceramic tiles in vertical surface 300x450x7mm thick in dado over 10mm thick screed bed in CM 1:4 on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed |
| 67 | S&F Vitreous China urinals,half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and Union for discharge pipe incl CP 40mm waste coupling and PVC 40mmwaste pipe 900mm long . |
| 68 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 69 | S&F mirrorbevelededge 600x450mm of selectedqualitymoundedon 6mm thickcommercial plywood and fixed towooden plugs with CP brass screws and cup washerall as specified and directed. |
| 70 | S&F Vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets,excludingpillar cock 15 mm bore CP, PVC connection of 450 mm long including PVC(HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc complete all as specified and directed. |
| 71 | S&F pillar tap cost copperalloy withcaptain heads chromium plated screwed down high pressure with or without (Hot or Cold) with long screwed shanks and fly nuts screwed for iron pipe 15mm bore |
| 72 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm, single side prelam PVC sheet used and edges will be painted to match with printed to match with prelam sheet, reinforced with MS square tube & fixing in opening including hold fast. |
| 73 | S&F factory made solid PVC Moulded door shutter 28 to 30mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on front face& 2 mmplain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and directed. |
| 74 | S&F, 200 mm long aluminium anodised barrelbarrel tower bolts of extruded section and fixed as specified and as directed. |
| 75 | S&F, 100 mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed , type C-21 |
| 76 | S&F, 125 mmaluminium handles cast type, anodised complete all as specified and as directed. |
| 77 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate laid in panels surface finish evenand smooth without using extra cement as in plinth protection complete all as specified and as directed. |
| 78 | M&L for forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade \"B\" for 100mm thick slab |
| 79 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below :-(a) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth.(b) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (c) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(d) Preparing & cleaning of fully dried cement plastered surface.(e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384.(f) A layer of APP based polymeric membrane3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:-Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 80 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 10 Sqmm, 2 core stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 81 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 16 Sqmm, 2 core stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 82 | S&F sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed. |
| 83 | M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments. |
| 84 | M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 32mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. |
| 85 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing PVC/modular metal box of suitable size with 3mm thick hylam sheet cover for fixing ofswitches, sockets, fan regulators etcfor one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed. |
| 86 | All as per Item No.85here in above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 87 | All as per Item No.85here in above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm |
| 88 | S&F switch piano, 5 Amp single pole, flush type one way 240 volts bearing ISI marked complete all as specified and as directed. |
| 89 | S&F switch socket combination 2 in 1, 3 pin, 5 Amps,flush type, 240 volts complete all as specified and as directed. |
| 90 | S&F angular/batten holderPVC/Polycarbonate suitable for batten fittings including oneLED Lamp of 9W of complete all as specified and directed. |
| 91 | S&F ceiling rose, 3 phase, PVC polycarbonate, isolated body (with PVC box) bearing ISI marked complete all as specified and as directed. |
| 92 | S&F LED tube light batten (1.2M) made of extruded aluminum housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. |
| 93 | S&F factory made board distribution (DB)double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral,4 way, 240 Volts suitable for housing MCBsincluding complete all as specified and as directed. |
| 94 | S&F MCB SPN 40 Amps \"B\" Series 10 KA 240 volts complete all as specified and directed. |
| 95 | S&F MCB SPN 6-32 Amps \"B\" Series 10 KA 240 volts complete all as specified and directed. |
| 96 | S&F MCB SPN 6-32 Amps \"C\" Series 10 KA 240 volts complete all as specified and directed. |
| 97 | S&F switch socket out let combination multipurpose 3/5 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. |
| 98 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground levelwith the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed. |
| 99 | S&F Exhaust fans AC single phase 230/240V of size 300mm sweep with louver complete all as specified and directed. |
| 100 | M&L for cutting of circular hole at any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, groutig 04 Nos 100 mm long 12mm dia stud bolt including good to distrubed surfaces of wall and colour wash to match as per existing colour complete all as specified and directed. |
| 101 | S&F 35 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed. |
| 102 | S&F building light bracket fabricated out of GI tubing light grade 32 mm bore bend to the shape as directed and of length 1.5mtr complete with mounting MS clamp of flat iron size 40x5mm of suitable length 02 pairs including nut bolts etc of suitable size, complete all as specified and as directed. |
| 103 | Boring of holes horizontal for laying not less than 50mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate. |
| 104 | S&F water heater storage type 230V, AC, electric capacity 25 Litre, BEE 5 star rate with necessary supporting clamping arrangement and complete all as specified and directed. |
| 105 | S&F water heater storage type 230V, AC, electric capacity 50 Litre, BEE 5 star rate with necessary supporting clamping arrangement and complete all as specified and directed. |
| 106 | M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size,fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor(FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. |
| 107 | M&L for pipe galvanized 15mm dia, \"Medium class\" including fittings and fixed complete to walls and ceiling complete all as specified and directed. |
| 108 | S&F 15mm cromium plated bib taps, cast copper alloy with crutch orbutterfly handle, fancy type,screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 109 | S&F 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete all as specified and as directed. |
| 110 | S&F single pointed air termination Aluminium rod, 12mm dia, 300mm long complete all as specified and as directed. |
| 111 | S&F aluminium strip 25mm x 3mm complete with saddles and fixing screws for ftiing the strip omplete all as specified and as directed. |
| 112 | S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and as directed. |
| 113 | S&F GI strip 32mm x 6mm complete with saddles and fixing screws for fitting the strip all as specified and directed. |
| 114 | Supply, install, connect, test and commissioning of Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, within built in airioniser, Plasma filter for better indoor air quality, leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 1.5 TR, inclusive of suction and discharge copper pipe lines of suitable sizeandnecessary brazing and providing nitrile tubing and wraping the ends with PVC insulating tape and mounting on suitable bracket, suitable drain pipe for disposal of wastewater upto ground level and testing,finishing the disturbed surfaces of walls to match with the existing surfaces complete all as specified and as directed. |
| 115 | S&F voltage stablizer for automatic operation , single phase naturally air cooled indoor type and designed for input variation between 170 volts to 280 volts with output voltage stablizer at 230 volt with accuracy of +-2.5% and of capacity 3 KVA complete all as specified and as directed. |
| 116 | S&F sheet metal enclosure with socket plug top two pin and earth plug and double pole 20Amp MCB complete all as specified and directed. |