| 1 | Demolition of brickwork or stone masonry of any description and in any position including all quoins, arches, pillars, etc., built in cement mortar including disposal of debris off the premises complete all as specified and directed. |
| 2 | M&L for Pre-cast cement concrete Type C1, 1:3:6 (20mm graded aggregates) blockmasonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed. |
| 3 | Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls/celingetc.including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed |
| 4 | M&L, 10mm thick rendering in cement mortar (1:6), on other than fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in copings, kerbs etc. complete all as specified and directed. |
| 6 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsionpaint over new surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 7 | Demolition of stone slabs, tiles, cement concrete tiles/paver blocks of of any description and in any position or thickness in floors, laid and bedded in any mortar including disposal of debris off the premises complete all as directed. |
| 8 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in near cement slurry in floors With grey cement and pigments and including 15mm screed bed in CM 1:4 complete all as specified and directed. |
| 9 | Demolition of cement concrete in ground floors and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 10 | M&L for PCC (1:2:4), Type B1, 100 mm thick using 20mm graded stone aggregate, concretesurface furnished even and smooth withoutusing extra cement as in hard standing complete all as specified and directed. |
| 11 | M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in sub bases 100 mm thick complete all as specified and directed. |
| 12 | M&L for 60mm thickness, M-35 Grade rubber moulded precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 with grey cement and pigment, laid over and including 25 mm thick sand cushioning complete all as specified and directed. |
| 13 | Demolition of RCC of any description and any position not otherwise specifically provided for complete all as specified and directed. |
| 14 | M&L, pre cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slabs including necessary form work, placed in position, set in cement mortar (1:4) including dismantling of damaged RCC cover slabs complete all as specified and directed.Note: Reinforcement shall be measured and paid separately. |
| 15 | M&L for formwork fair finished to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 16 | M&L for Formwork fair finished square/ rectangular/ polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 17 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L for M30 concrete as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 20 | M&L for M30 concrete as inColumns, pillars, piers, posts and struts complete all as specified and directed. |
| 21 | Dismantling offencing wire mesh any type complete all as specified and directed. |
| 22 | Supply and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade as required complete all as specified and directed. |
| 23 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 24 | Supply and fix Mild Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 25 | M&L for preparation of new steel surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 26 | Cleaning of blockaged sewage line up to 150mm dia including manholes ofby roding and flushing after cleaning and removing mud/sludge etc to a distance exc 250m but n. exc 500m and spreading in low laying areas and covering with loose soil and complete all as specified and directed. Note: length will be measured through out the manholes for each time of cleaning. |
| 27 | Cleaning of manhole / gully trap / floor trap blockages (including WC, urinal, kitchens and bathrooms) systematically using necessary tools mechanically and/or manually such as by rodding, bamboo fanti and disc of required size (with safety measure gas from both side between two adjacent manhole/gully traps or WC/NT of any size or depth , taking out sludge in semi liquid stage / roots of the tree etc including all water effluents etc.and removing all materials from site of work upto a distance exceeding 50 mtr and depositing in earth pit of suitable size including supply and sprinkling of bleaching powder and covering sludge with earth after removal of blockage etc complete all as specified and directed. |
| 28 | Cleaning of septic tanks completely by emptying liquid, semi solid, solid foul contents including cleaning of inlets, outlets and getting out using suction pumps and filling the foul material into the covered tanks attached to suction pump and removing and disposing the same at a place meant for disposal of foul material outside the navy area complete all as specified and directed. |
| 29 | Dismantlingof cast iron or salt glazed ware or reinforced concrete 150 mm dia pipes set in cement mortar including bedding haunching complete all as specified and directed. |
| 30 | Dismantlingof cast iron or salt glazed ware or reinforced concrete 100 mm dia pipes set in cement mortar including bedding haunching complete all as specified and directed. |
| 31 | M&L 150 mm internal dia cast iron pipes with spigot and socket ends, class ‘A’ laid in trenches/manhole walls with cement joints of any description complete all as specified and directed. |
| 32 | M&L 100 mm internal dia cast iron pipes with spigot and socket ends, class ‘A’ laid in trenches/manhole walls with cement joints of any description complete all as specified and directed. |
| 33 | M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) bed to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 34 | M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) bed to 100 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 35 | S&F in repairs PVC (SWR) pipe, single socketed in any length with rubber ringjoints fixed to walls in clamps, 110 mm bore of pipe complete all as specified and as directed. |
| 36 | S&F in repairs PVC (SWR) pipe, single socketed in any length with rubber ringjoints fixed to walls in clamps, 75 mm bore of pipe complete all as specified and as directed. |
| 37 | S & F in repairs PVC (SWR) vent cowl for 110 mm bore pipe all as specified and directed. |
| 38 | S & F in repairs PVC (SWR) vent cowl for 75 mm bore pipe all as specified and directed. |
| 39 | S&F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal for oval access door of 110 mm bore pipe complete all as specified and directed. |
| 40 | S&F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal for oval access door of 75 mm bore pipe complete all as specified and directed. |
| 41 | S&F in repairs PVC(SWR), bends (any radius) with reducers (diminishing and tapers) (large bore to be measured) with oval access door fitted to 110 mm bore pipes complete all as specified and as directed. |
| 42 | S&F in repairs PVC(SWR), bends (any radius) with oval access door fitted to 75 mm bore pipes, complete all as specified and as directed. |
| 43 | M & L fixed in repairs cast iron nahani trap/ gully trap125/100mmsetting and jointingwithsolvent cement complete all as specified and directed. |
| 44 | S&F fixed in repairs 100 mm bore cast iron floor trap with stainless steel grating including jointing to waste pipe fixed in cement concrete type B 1 (1:2:4) with solvent cement,complete all as specified and directed by Engr-in-charge. |
| 45 | S&F in repairs Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe, complete all as specified and directed. |
| 46 | S&F in repairs, vitreous china squatting pan, ‘Orissa’ pattern of size 580 x 440mm, white, with integral foot rests, including connection to trap, and to flushing pipe, antisyphonage pipe, etc., complete including provision of cement concrete bedding in 1:5:10 and making good to floor complete all as specified and directed. |
| 47 | S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white including connecting to trap and to flushing pipe, anti syphonage pipe etc., complete including fixing to floor with bolts, including provision of plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. |
| 48 | S&F in repairs, 10 litres, PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 49 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises all as specified and directed. |
| 50 | M&L, 7 to 8mm thick coloured, joint free Non skid ceramic tiles of size 400 x 400mm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in cement mortar 1:4 complete all as specified and as directed. Note: Shade, design/pattern of tiles shall be as approved by GE |
| 51 | M&L, coloured glazed ceramic tilesof size 300 x 450mm, 6 to 7mm thick in dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed. |