| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,at CSIR-IMMT dumping yard.All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in foundation and plinth in: :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour lakha red Area of slab upto 0.50 sqm |
| 5 | Chequerred precast cement concrete tiles 25 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).ordinary cementwithout anypigment(Gicco make) |
| 6 | 12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand) |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 8 | Painting with synthetic enamel paint of approved brand (Apcolite premium,Asian paint)and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 9 | Dismantling tile work in foot pathlaid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 10 | Providing and laying design mix cement concrete of M-30 grade, in roads using cement content as per design mix, using coarsesand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria,laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-charge (Item of joint fillers, sealants, to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer |
| 11 | Providing and filling in position ruberised bitumen hot sealing compound for expansion joints in roads /pavements all complete as per direction of the EIC. |
| 12 | Supplying and filling in plinth with local sand under floors including, watering, rammingconsolidating and dressing complete. |
| 13 | Providing and laying design mix cement concrete of M-10 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria,, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture,curing, complete all as per direction of Engineer-in-charge .Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer .Cement Consumption in M-10 is @250Kg/Cum |
| 14 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 15 | Providing and fixing 25mm x 5mm GI strip in 40 mm dia GI pipe from earth electrode including connection with G.I. nut, bolt, spring, washer exacavation and re-filling etc. as required |
| 16 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required. |
| 17 | Supply & drawing of 3core, 1.5 sq mm size cord wire / PVC insulated, PVC sheathed copper conductor cable (Finolex/ Poly-Cab/KEI make) as approved, in existing steet light pole for steet light connection from junction box to steet light etc as required. |
| 18 | Laying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade armoured cable as approved by dept. Engg. of 4 core x 10 sq mm size in the RCC / Hume / Metal pipe/ DWC pipe etc. as required. |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 10 sq mm size (22 mm) of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | Providing and making steel pole collar with cement concrete (1 cement:3 coarse sand : 6 aggregrate stone 20mm) of specified size and shape including form work,plastering if required,curing etc as required (volume of pole/pipe not to be deducted) |
| 21 | Supply and embedding 32 mm dia G.I pipe (medium class) in pole collar / foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 22 | Providing, fixing and laying of 250 mm dia RCC pipe NP2 class(light duty) in ground complete with RCC collars ,jointing with cement mortar 1:2 (1 cement:2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 23 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required |
| 24 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930 / IS 16205, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench butexcluding sand cushioning and protective covering etc., complete as required. |
| 25 | Supply of 9Mtr long MS painted swaged type steel tubular pole (410 SP-29) with MS base plate 300 x 300 x 6 mm and having pole dimentions :-Bottom:-139.7 OD X 4.50mm x 5 mtr long ,Middle:- 114.3 OD X 4.50MM X 2.0 mtr long.Top :-88.9 OD x 3.65 mm x 2.0 mtr long etc as required |
| 26 | Supplying and fixing of 48mm dia X 1.00 metres long MS painted single Arm bracket for mounting of street light fittingetc. as required. |
| 27 | Supplying and fixing of 48mm dia X 1.00 metres long MS painted Triple Arm bracket for mounting of street light fittingetc. as required. |
| 28 | Supplying and fixing of wheather proof cable end box 140 mm x 140 mm x 95 mm (or as approved) size out door type PVC box on existing tubular pole (Sintex/hensal/ Schininder make ) having one no 6 A rating SP MCB C-Series and connector for cable connection etc as required. |
| 29 | Supply, installation, testing and commissioning of prewired street light LED fitting of 7500 lumen, not more than 75watt (Philips/ Klite as approved ) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc. as required. |
| 30 | Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex/ KEI / RR Kable make or as approved by dept) armoured cable of 4 core x 10 sq mm size etc as required. |