| 1 | “(i) Renovation of 33/11 kV Depota DSS under Tezpur ESD-II, within the jurisdiction of Tezpur Electrical Circle, APDCL and (ii) Renovation of the 33/11 kV Agomani DSS under Agomani ESD, within the jurisdiction of Kokrajhar E.C., APDCL”. Please Enable Macros to View BoQ information |
| 2 | Supply and Erection of ISOLATOR 33 KV TPGO-DBCR with earth switch and GI Mounting Structure 800 Amps |
| 3 | Supply and Erection of 33 KV 0.5 Class 1ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 400-200/5-5A, 25kA for 3 sec |
| 4 | Supply and Commissioning of 33KV C&R Panel for Transformer with IEC 61850 compliant differential relay (numerical type & with static TVM) |
| 5 | Supply and Erection of 33 KV 0.5 Class 1ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 200-100/5-5-5A, , 25kA for 3 sec |
| 6 | Supply and Commissioning of 33KV VCB 1250A with GI Mounting Structure |
| 7 | Supply and Commissioning of 11 KV C&R Panel for Outdoor VCB (with IEC 61850 compliant numrical relay and static TVM) |
| 8 | Supply and Erection of ISOLATOR 11 KV TPGO-DBCR without earth switch & GI Mounting structure 800Amps |
| 9 | Supply and Erection of 11 KV 0.5 Class 1ph Outdoor CT with marshaling box & GI mounting structure with connector 600-300/5-5-5A, 25kA for 3 sec |
| 10 | Supply and Commissioning of 11KV Outdoor VCB 1250A with GI structure & marshalling box |
| 11 | Supply and Erection of 11KV 0.5 Class 1ph Outdoor CT with marshaling box & GI mounting structure with connector 400-200/5-5A, 25kA for 3sec |
| 12 | Supply and Erection of 11KV/110V 1ph Outdoor PT with marshaling box & GI mounting structure with connector (Set comprising of three units) |
| 13 | Supply and Erection of 11 KV GOAB Switch 630A |
| 14 | Supply, fitting and fixing of Bi metalic 400 Sq mm |
| 15 | Supply and Erection of GI strip 50X6mm for DTR Neutal earthing |
| 16 | Supply and Erection of GI strip 25X4mm for equipment earthing |
| 17 | Chemical Earthing complete with Gel filled 50mm dia 3 mtrs Copper bonded earthing electrode and 40 Kg Backfilling Compound MFCE |
| 18 | Supply, fitting and fixing of GI Nut & Bolts with Washer (Assorted) |
| 19 | 33KV 10KA Lighting Arrestor with Surge Monitor & GI Mounting Structure (Station Type) |
| 20 | Supply and Erection of 11KV 10KA Lightning Arrestor Station Type Class 2 |
| 21 | RCC foundation for VCB |
| 22 | Supply and Erection of CONTROL CABLE, 1.1KV GRADE (COPPER) 4C x 2.5 sqmm |
| 23 | Supply and Erection of CONTROL CABLE, 1.1KV GRADE (COPPER) 7C x 2.5 sqmm |
| 24 | Supply and Erection of CONTROL CABLE, 1.1KV GRADE (COPPER) 10C x 2.5 sqmm |
| 25 | Supply, fitting and fixing of GI Channel (75x40x6)mm |
| 26 | Supply, fitting and fixing of 11 KV Danger Plate |
| 27 | Supply, fitting and fixing of 33KV Danger Plate |
| 28 | Supply and Commissioning of 11KV Indoor VCB Panel - 9 Unit Equipped with IEC 61850 compliant numerical relays, 0.5s accuracy class cat-A, E2, M2, C2 class Vacuum Circuit Breaker of 26.3kA STC, 1200 A busbar & other components as per standard Technical specification of APDCL |
| 29 | Supply and Installation of 150AH 110V Maintenance Free Battery Bank (VRLA Battery Bank) |
| 30 | Supply and Installation of Battery charger 110V suitable for charging 150AH, 110V Battery Bank , Dual mode double circuitry SCR Variac Float & Boost Charger |
| 31 | Supply and Commissioning of 33KV VCB 1250A with GI Mounting Structure |
| 32 | Supply and Commissioning of 33KV C&R Panel for Feeder (with IEC 61850 compliant numerical relay & static TVM) |
| 33 | Supply and Commissioning of 33KV C&R Panel for Transformer with IEC 61850 compliant differential relay (numerical type & with static TVM) |
| 34 | Supply and erection of Control Cable 7C x 2.5 sqmm Armoured |
| 35 | Supply and erection of Control Cable 10C x 2.5 sqmm Armoured |
| 36 | Supply and erection of 11 KV grade XLPE Cable jointing Kit 3C x 300 sq.mm. Outdoor |
| 37 | Supply and erection of 11 KV grade XLPE Cable jointing Kit 3C x 400 sq.mm. Outdoor |
| 38 | Supply and Installation of 3 Ph 4W Combined CT/PT Accuracy Class: 0.2, 400/5A, STC: 25kA for 1 Sec |
| 39 | Supply and Installation of 3 P h 4W Combined CT/PT Accuracy Class: 0.5, 200/5A, STC: 18.1 kA for 1 Sec |
| 40 | Supply and erection of 33KV 10KA Lighting Arrestor with Surge Monitor & GI Mounting Structure (Station Type) |
| 41 | Supply and erection of 11 KV TPGO-DBCR without earth switch & GI Mounting structure 800Amps |
| 42 | Supply and erection of GI earthing Pipe 50mm dia 3m length 3.15 mm thickness with perforated holes of 15mm dia at 30 cm interval along length of the pipe |
| 43 | Supply and erection of GI strip 50x6mm |
| 44 | Supply and erection of Insulated water proof bimetalic lug for transformer connections. (set contain 5 nos. lugs as per cable) as per NFC Std. |
| 45 | Supply, fitting and fixing of GI Nuts & Bolt with GI Washer (Assorted) |
| 46 | Supply and Commissioning of 11KV outdoor VCB 1250A with GI Mounting Structure |
| 47 | Commissioning of 33KV C&R Panel for Feeder (with IEC 61850 compliant numerical relay & static TVM) |
| 48 | Commissioning of 33KV C&R Panel for Transformer with IEC 61850 compliant differential relay (numerical type & with static TVM) |
| 49 | Commissioning of C&R Panel for 11KV Outdoor VCB (with IEC 61850 compliant numrical relay and static TVM) |
| 50 | Installation of 415V AC Distribution Board (O/g feeders 6 Nos.) |
| 51 | Installation of 110V DC Distrbution Board (O/g feeders 4 Nos.) |
| 52 | Construction of Ramp to prevent water Ingress at Control Room of 33/11 kV Agomoni DSS and other ancillary works to control seepage of water (Detail BOQ attached as Annexure) |
| 53 | RCC foundation for 11KV Isolator as per standard drawing and technical specifications |