| 1 | Supply, erection, testing, and commissioning of two energy meters with required CTs, surface-mounted PVC meter boxes, and complete wiring for the New CRC and New Electrical Extension Building at VNIT campus. |
| 2 | Supply, installation, testing, and commissioning of an IP65 surface-mounted heavy-duty PVC enclosure box suitable for three-phase static trivector energy meters, featuring a transparent window, weatherproof, shockproof, and splash-proof design. The unit shall be mounted on a painted iron frame fixed to the wall with proper grouting, complete in all respects. |
| 3 | Supplying and erecting static energy Trivector meter 3x240V 50 Hz. 0/20-100A meter AC 3 phase 4 wires LCD/LED display (Measures & displays Trivector, V, I, kW, PF, Hz, last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weatherproof PVC wires duly tested for class 1.0 accuracy by electric supply company. |
| 4 | Supplying, erecting, testing & commisioning metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and painted with one coat of red lead paint and 2 coats of enamel paint or powder coating complete as per specification no. CP/SH/CR |
| 5 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/ Bus bars or any other places as per specification No: WG-MA/BW |
| 6 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 7 | Supplying and erecting crimping type copper lugs for cable upto 16 Sq mm complete as per sepecification No. CB-CL/CU. |
| 8 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 9 | Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit |
| 10 | Supplying and erecting hylam sheet/ ebonite sheet 3 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. |
| 11 | Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burdenerected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates (to be submitted by the vendor). Note: The CT internal aperture shall be suitable for 300 sq. mm cables, and the 300 sq. mm cable terminated with lugs must pass through the CT. |