| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit(credit for above items shall be made as per condition laid down under schedule of credit seprately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed |
| 2 | Material & Labourfor point wiring using approved colour coding as per IS (Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathedFRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in andincluding medium grade,PVC casing & capping of suitablesizeon walls/roof/flooretc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge for the following :- Make: polycab /Finolex/ RR |
| 3 | One fan/light /bell point controlled by one switch/bell push |
| 4 | One switch socket outlet 5 Amps on independent board |
| 5 | One socket outlet 5 Amps on the same board |
| 6 | All as per Item No 2 here-in-before but with 2.5 SqmmPVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathedcopper conductor FRLS cable 1100Volts grade and 2.5 sqmm asearth continuity conductorfor one switch socket outlet 15 Amps on independent board complete all as specified anddirectedby Engr- in - Charge. |
| 7 | All as per Item No 2 here-in-before but with 4.0 SqmmPVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathedcopper conductor FRLS cable 1100Volts grade and 4 sqmm asearth continuity conductorfor power socketon independent board complete all as specified anddirectedby Engr- in - Charge. |
| 8 | Material & Labourfor point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathedFRLS cable1100 volts grade , ISI-694 (1990)marked with valid CML No in andincluding medium grade,PVC Conduitof suitablesizeon walls/roof/flooretc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge for the following :- Make polycab /Finolex/ RR |
| 9 | One fan/light /bell point controlled by one switch/bell push |
| 10 | One switch socket outlet 5 Amps on independent board |
| 11 | One socket outlet 5 Amps on the same board |
| 12 | All as per Item No 5 here-in-before but with 2.5 SqmmPVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathedcopper conductor FRLS cable 1100Volts grade and 2.5 sqmm asearth continuity conductorfor one switch socket outlet 15 Amps on independent board through medium PVC conduitcomplete all as specified anddirectedby Engr- in - Charge. |
| 13 | All as per Item No 5 here-in-before but with 4.0 SqmmPVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathedcopper conductor FRLS cable 1100Volts grade and 4 sqmm asearth continuity conductorfor power socketon independent board through and including medium PVC conduit complete all as specified anddirectedby Engr- in - Charge. |
| 14 | Material & Labourfor sub main wiring but using two single core multistrandedPVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into and including PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or sizecomplete all as specified and directed by Engr-in-Charge.Note: Two single core cable, earth wire and PVC conduitshall be measured as one length. |
| 15 | Ditto item no 08 above but of 6 Sqmm |
| 16 | Supply and fix in repair ceiling rose surface bakelite with three terminals type in complete all as specified and directed. |
| 17 | Supply and fix in repairs switch piano type one way 6 Amps flush type , 240voltACcomplete all as specified and directed |
| 18 | Supply and fix in repairssocket outlet 2 in1,3 pin 5 Amps complete all as specified and directed |
| 19 | Supply and fix in repairs switch socket combination (SSC)2 in 1, 3 pin, 5Ampsflush type ,240voltACcomplete all as specified and directed |
| 20 | Supply and fix in repairs switch piano type 16 Amps flush type ,240voltACcomplete all as specified and directed |
| 21 | Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin16 Amps flush typecomplete all as specified and directed |
| 22 | Supply and fix in repairs switch socket combination (SSC)2 in 1, 3/5 pin, 16 Ampsflush type ,240voltACcomplete all as specified and directed |
| 23 | Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240voltACcomplete all as specified and directed |
| 24 | Supply and fix in repairsswitch piano type two way 6 Amps flush type ,240voltACcomplete all as specified and directed |
| 25 | Supply and fix in repairs Bell push, Modular type, 6 Amp flush type ,240voltACcomplete all as specified and directed |
| 26 | Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed. |
| 27 | Supply and fix inrepair modular switch 2 way 6A 1module complete all as specified and directed. |
| 28 | Supply and fix inrepair modular socket 6A2/3 pin combined 2 module complete all as specified and directed. |
| 29 | Supply and fix inrepair modular socket 6A /16A2/3 pin combined 2 module complete all as specified and directed. |
| 30 | Supply and fix inrepair modular fan regulator,120 watt - 2 module complete all as specified and directed. |
| 31 | Supply & fix ix in repairstepped type electronic fan regulator 120 watt, 240 voltflush type on the existing phenolic laminated sheetcomplete all as specified and directed |
| 32 | Supply andfix in repairelectric bell Ding Dong,AC 230 volts complete all as specified and directed. |
| 33 | Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed. |
| 34 | 1 module |
| 35 | 2 module |
| 36 | 3 module |
| 37 | 4 module |
| 38 | 6 module |
| 39 | 8 module |
| 40 | Supply and fix in repair of RCCB 63 A, four pole, 30 mA complete all as specified and directed by Engr-in-chrge. Make: Hager/L & T/Standard |
| 41 | Supply and fix industrial wall mounted plug socket suitable for IP 44 degree of protection of 32Amps rating 2P+E complete all as specified and directed. Make: L&T/Indoasian/C&S/Legrand |
| 42 | Supply & fix sheet metal enclosures for double door distribution boardfactory made duly painted of following capacity with 200 amps rated bus bar, suitable for fixing MCB /Isolators complete all as specified and directed.Make : L & T/Legrand/Havells |
| 43 | 12 way SPN , 240V |
| 44 | 8 way SPN 240V |
| 45 | 4 way TPN ,415V |
| 46 | 8 way TPN ,415V |
| 47 | Supply & fixMCCB 125 Amps,4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacitycomplete all as specified and directedMake: L &T /Legrand/Indoasian/standard. |
| 48 | Ditto item no 31 above but of capacity 100 Amps. |
| 49 | Supply and fixminiature circuit breaker (MCB) of following current carrying capacity, in the MCB DB complete with connection testing and commissioningcomplete all as specified and directed.MakeL &T /Legrand/Havells |
| 50 | SP 5/6 to 32 AMP,240V, 10 KA \"B\" curve |
| 51 | SP 40 AMP,240V, 10 KA \"B\" curve |
| 52 | SPN 32 Amps,240V, 10 KA \"B\" curve |
| 53 | SPN 40 Amps ,240V, 10 KA \"B\" curve |
| 54 | TPN 63 Amps,240V, 10 KA \"B\" curve |
| 55 | Supply & fixwall mounted extruded aluminium housing high quality indoor batten of following capacity colour temperature 6500 K (4\" long) lumen 2000 to 3000, PF> 0.9, THD less 15%diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make :Havells/Wipro/Halonix Note:- The rates are inslusive of cost of square box - 02 Nos including suitable size of clamps and screws etc. |
| 56 | LED tubelight fitting of20 watt/22 watt, 4 Ft long |
| 57 | LED tubelight fitting of10watt, 2 Ft long |
| 58 | Supply & fixwall/ceiling mounted Inverter LED tube light fitting 4\" feets long with opal diffuser and having aluminium body. Energy efficient high quality invertor batten should have Lithium ion battery of 3.7V, 19 WH having inbuilt battery backup upto 2Hrs with high power brightness having BIS certification, LED fitting should be LM 80 certified with system efficasy greater than 100 lumens/watt, including LED tube 20/22 watt having colour temperature 6500 K , PF> 0.95, THD less 10%, with IP20 protection having open and short circuit protection, having input voltage range 90V to 300V connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make :Havells/Jaquar/Halonix/Crompton .Note :- The rates are inclusive of cost of square box-02 nos including suitable size of clamps and screws etc. |
| 59 | Supply & fix Recess mounting LED flat panel light fitting of following wattage and size with efficient LEDs lumen 2000 to 3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and make complete all as specified and directed Make :Havells/Wipro/Halonix |
| 60 | 36 watt, 600mm x 600 mm size |
| 61 | 18/20 watt, (1x1 )ft |
| 62 | Circular in size18/20 watt not less then 6\"\" dia |
| 63 | Supply & fixwall mounted high quality indoor wall bracket light cylinderical/oval shapeaesthetically designedfitting with B22D lamp holderand12 Watt bulbtemp range 4000k to 6500 K as per site requirementconnecting with three core flexible copper wirecomplete all as specified and directed by Engr-in-charge.Make :Halonixcat No: HLWB-01-B22 or equivalent in Havells/Wipro |
| 64 | Taking down old unserviceable MHbay light and Supply and Fixing high efficient suspended type 150 watt, 230 V, lumen 2000 to 3000, PF> 0.9, THD less 10% LED bay light of die cast aluminium housing with lens embedded PC cover IP 66with efficasy not less then 120 lm/W, as per IS -10322 , high voltage cut off,open and short circuit protectionincluding constant voltage and current LED driver all as directed. Note: (i) Making arrangement forT & P to fixing of bay light isincluided in quoted rate. Make :Havells/wipro/Halonix |
| 65 | Taking down old unserviceable Bldg security light and Supply & fixhigh efficent LED building security light30 watt, 230 V, lumen 2000 to 3000, PF> 0.9, THD less 10%, made of pressure cast aluminuim housing with high power LEDs, lens and toughned glass IP 66 connecting with three core flexible copper wire from connector to ceiling rose complete all as specified and directedMake Halonix/Bajaj/Havells. |
| 66 | Supply & fixin repair bracket for mounting building security lightmade out of 40 mm dia Light Grade GI pipe bend inanglewith holding MS clampstwo nos each bracket of size 25x3 mm includingscrewetc for fixingcomplete all as specified and directed by Engr-in-charge |
| 67 | Decarbonizing ofindoor MCB DB\"s / Meter box panel and distribution panel of bldgs by dismantling the old MCCB\"s, old Bus bars , cable connections, old Amps meter and old voltmeter and cleaning the panel with ctc solvent, and removing the old/burnt control wiring, replacing the old/burnt bus bar of any size if any and fixing properly thehanging/loose front and rear opening doors of the panels, by welding of hinges including welding of broken MS sheet using extra sheets of required size also replacing burnt thimbles with new existing size thimbles, indicator lamps, including powder coating painting of panel with suitable \"U\" type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directedby Engr -in- charge. |
| 68 | Material & Labourfor earthing complete in repairs with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.0 mm dia galvanised earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 (20mm graded stone aggregate) RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and complete all as specified and directed. Note:(i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. |
| 69 | Material & Labourfor repairs /re-fixing on exiting or new location to storage type electric water heater(geyser) of storage capacity 25 ltrs /35 ltrs /50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning.(c)Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) Supply & fixReplacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs. |
| 70 | Supply & fixin repairs thermal cutout ISI marked temp range 50 to 80/90 degree as required at site for geyser of capacity 25 Ltr /35 Ltr /50 Ltr of any make complete all as specified and directed by Engr-in-charge |
| 71 | Supply & fixin repairs safety valve/high pressure valve ISI marked as per site requirement complete all as specified and directedby Engineer-in-Charge. |
| 72 | Supply & fixin repairs heating element of following rating as required at site including rubber washers complete all as specified and directed by Engr-in-charge. |
| 73 | 1/1.5 KW,240 volt |
| 74 | 02 KW ,240 volt |
| 75 | Supply & fixin repairs PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connectioncomplete all as specified and directed by Engr-in-Charge |
| 76 | Supply & fix in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connectioncomplete all as specified and directed by Engineer-in-charge. |
| 77 | Supply & fix in repairs, non return valve 15 mm dia of brass, ISI markedcomplete all as specified and directed by Engineer-in-charge. |
| 78 | Supply & fix in repair stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore complete all as specified and directed by Engr-in-Charge |
| 79 | Material & Labour for repairing and replacment of unserviceable copper container of capacity 25 Ltrs to 50 Ltrs of solar water heater of any type after completion of work testing the heater for following complete all as specified and directed by Engr-in-Charge |
| 80 | Copper container 50/100 ltr |
| 81 | Copper container capacity 25 Ltrs of water heater (gyeser) |
| 82 | Taking down following old unserviceable Ceiling /Exhaust/Air circulator fans of any type from any height and Material & Labourfor rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire of appropriate gauge including connection, capacitor base and testing for following complete all as specified and directed by Engr-in-Charge. Note: Bearing, fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule. |
| 83 | Ceiling fanof 1200/1400 mm sweep |
| 84 | Exhaust Fan of sweep 275 to 300 mm |
| 85 | Exhaust Fan of sweep 350 to 450 mm |
| 86 | Air circulator of sweep 350 to 450 mm |
| 87 | Supply onlyball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC |
| 88 | Supply only ball bearing suitable for 275 mm to 450 mm exhaust fan complete all as specified and directed Make : SKF/NBC |
| 89 | Supply only fan capacitor of following capacitycomplete all as specified and directed |
| 90 | capacitor 2.5 mfd |
| 91 | capacitor 4 mfd |
| 92 | Supply only , rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge. |
| 93 | Supply onlygunmetal bush of suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge. |
| 94 | supply onlyfan down rod of following length with white enamelled painted with both side hole for hanging fan of sweep 1200/1400mm sweep complete all as specified and directed by Engr-in-charge |
| 95 | 1 ft long |
| 96 | 2 ft long |
| 97 | Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor sizecomplete all as specified and directed |
| 98 | Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator sizecomplete all as specified and directed |
| 99 | Supply onlyfan canopyset off white /white coloured as per colour of ceiling fan of sweep1200/1400mmcomplete all as specified and directed |
| 100 | Material & Labour in repair for following PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge. |
| 101 | 100 mm x 100 mm and 50 mm deep |
| 102 | 200 mm x 150 mm x 50 mmdeep |
| 103 | 250 mm x 200 mm x 50 mm deep |
| 104 | 150 mm x 150 mm x 50 mm deep |